Plan Review Details - Permit 07100221
| Plan Review Stops For Permit 07100221 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-11-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-11 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-11 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-23 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2007-10-23 16:18:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.THIS APPEARS TO BE A FLAT ROOF, BUT THE ENGINEER | | | SPECIFIES SHINGLES (PARTIAL SECTION).A MINIMUM OF | | | 2/12 PITCH REQUIRED, FBC 1507.2.2. | | | | | | 2.SPECIFY SLOPE, PARTIAL SECTION. FBC1507.2.2, | | | FBC*106. | | | | | | 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | | FOR COMPONENTS AND CLADDING, FAC9B72. | | | WWW.FLORIDABUILDING.ORG.PROVIDE PRODUCT APPROVAL FOR | | | THE ROOF. | | | | | | 4.PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER OF | | | RECORD (SHOP DRAWING REVIEW STAMP OR LETTER), | | | FBC*106.3.3. | | | | | | 5.PROVIDE A SITE PLAN SHOWING PROPOSED IMPROVEMENT. | | | | | | 6.DECLARE GOVERNING CODE INCLUDING 2007 AMENDMENTS. | | | | | | 7.DECLARE WIND DESIGN CRITERIA FBC1603.1.4. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-06 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-06 |
Time |
08:12 |
Sent To |
Z |
|
| Notes |
| 2007-11-06 08:12:48 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-09 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2007-10-09 13:50:55 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-06 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-06 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2007-11-06 10:21:57 | ***APPROVED - RESUB #1*** | | | | | | PROVISO:MINIMUM FRONT SETBACK REQUIREMENT OF 25' | | | | | | | | | | | | | | | SENT TO "B" - SH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-12 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-12 |
Time |
08:30 |
Sent To |
B |
|
| Notes |
| 2007-10-12 08:32:34 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | | SHOWING THE SCOPE OF WORK, WITH DIMENSIONS, AND SETBACK | | | DIMENSIONS TO THE PROPERTY LINES FROM THE PROPOSED | | | WORK. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
|