Plan Review Details - Permit 07100207
Plan Review Stops For Permit 07100207
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-11-26 Cont ID  
Sent By shill Date 2007-11-26 Time 18:35 Rev Time 0.00
Received By shill Date 2007-11-26 Time 18:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-11-19 Cont ID  
Sent By shill Date 2007-11-19 Time 13:42 Rev Time 0.00
Received By shill Date 2007-11-19 Time 13:42 Sent To  
Notes
2007-11-19 13:45:20****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1.)CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE
 ARCHITECTURE THROUGH A COMPANY, FS481.219(2).A SET
 HAS BEEN RETAINED.
  
 2ND REVIEW, ENGINEER WROTE IN HIS RESPONSE LETTER THAT
 THE PAPERWORK FOR INTER-AMERICAN DESIGN/BUILD IS IN
 PROCESS.I WAS UNABLE TO FIND EVIDENCE THAT A
 CERTIFICATE OF AUTHORIZATION HAS BEEN APPLIED FOR. THIS
 COMPANY HAS BEEN IN BUSINESS SINCE 2005.PLEASE
 PROVIDE EVIDENCE OF AN ACTIVE APPLICATION AS AGREED
 PREVIOUSLY (TELEPHONE CONVERSATION BETWEEN ME AND THE
 ENGINEER).OTHERWISE, THE PERMIT CAN BE ISSUED BUT A
 COMPLAINT WILL BE FILED WITH FBPE.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-29 Cont ID  
Sent By shill Date 2007-10-29 Time 11:09 Rev Time 0.00
Received By shill Date 2007-10-29 Time 11:09 Sent To Z
Notes
2007-10-29 11:17:28****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE
 ARCHITECTURE THROUGH A COMPANY, FS481.219(2).A SET
 HAS BEEN RETAINED.
  
 2.)ALL INFORMATION REQUIRED BY FAC61G15-23.002 IS
 REQUIRED TO BE ON EACH SHEET (ENGINEER).
  
 3.)THE TOP OF RAIL IS SHOWN AS DISCONTINUOUS, BUT
 HANDRAIL AND GUARDRAIL ARE SHOWN AT 3'6".CLARIFY.
  
 4.)HANDRAIL CANNOT BE DISCONTINUOUS AS SHOWN;
 EXTENSIONS REQUIRED FBC1009.11.4.
  
 5.)DECLARE OCCUPANCY FBC CHAPTER 3.COMPLIANCE WITH
 FBC1009.11.1 IS TO BE SHOWN ON THE PLAN.
  
 6.)ON THE STAIR PLAN, SHOW REQUIRED HANDRAIL
 EXTENSIONS AT THE TOP AND BOTTOM OF THE STAIRS,
 FBC1009.11.5.
  
 7.)SHOW EXTENSIONS ON THE PLAN AND PROVIDE AN
 ELEVATION FOR EITHER THE W OR E SIDE, FBC1009.11.5.
  
 8.)THE SITE PLAN IS NOT CONSISTENT WITH THE PLAN.
 THE PLAN SHOWS AN L SHAPED STAIR, SITE PLAN SHOWS A
 STRAIGHT RUN WITH A LANDING.
  
 9.)DECLARE GOVERNING CODE.
  
 10.)DECLARE WIND DESIGN CRITERIA FBC1603.1.4.
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-10-05 Cont ID  
Sent By swurafti Date 2007-10-05 Time 16:54 Rev Time 0.00
Received By swurafti Date 2007-10-05 Time 16:54 Sent To  
Notes
2007-10-05 16:55:17HISTORIC APPROVED BYGJUDGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-14 Cont ID  
Sent By adarroug Date 2007-11-14 Time 12:39 Rev Time 0.00
Received By adarroug Date 2007-11-14 Time 12:39 Sent To Z
Notes
2007-11-14 12:39:59TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-29 Cont ID  
Sent By shill Date 2007-10-29 Time 11:17 Rev Time 0.00
Received By shill Date 2007-10-09 Time 10:45 Sent To  
Notes
2007-10-09 10:45:20TO "MISC" BOX#1

Review Stop Z ZONING
Rev No 2 Status P Date 2007-11-16 Cont ID  
Sent By choops Date 2007-11-16 Time 08:49 Rev Time 0.00
Received By choops Date 2007-11-16 Time 08:49 Sent To B
Notes
2007-11-16 08:50:05***APPROVED - RESUB #1***
  
  
 SENT TO "B" - SH

Review Stop Z ZONING
Rev No 1 Status F Date 2007-10-29 Cont ID  
Sent By choops Date 2007-10-29 Time 13:17 Rev Time 0.00
Received By choops Date 2007-10-29 Time 13:17 Sent To  
Notes
2007-10-29 13:19:32***FAILED***
  
  
 1)INDICATE ON SITE PLAN THE SETBACK DIMENSIONS FROM
 THE PROPOSED TO THE PROPERTY LINES.INDICATE THE
 SEPARATION DISTANCE FROM THE PROPOSED STAIRWAY TO THE
 OTHER EXISTING STRUCTURES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720