Plan Review Details - Permit 07100207
| Plan Review Stops For Permit 07100207 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-26 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-26 |
Time |
18:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-19 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-19 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2007-11-19 13:45:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE | | | ARCHITECTURE THROUGH A COMPANY, FS481.219(2).A SET | | | HAS BEEN RETAINED. | | | | | | 2ND REVIEW, ENGINEER WROTE IN HIS RESPONSE LETTER THAT | | | THE PAPERWORK FOR INTER-AMERICAN DESIGN/BUILD IS IN | | | PROCESS.I WAS UNABLE TO FIND EVIDENCE THAT A | | | CERTIFICATE OF AUTHORIZATION HAS BEEN APPLIED FOR. THIS | | | COMPANY HAS BEEN IN BUSINESS SINCE 2005.PLEASE | | | PROVIDE EVIDENCE OF AN ACTIVE APPLICATION AS AGREED | | | PREVIOUSLY (TELEPHONE CONVERSATION BETWEEN ME AND THE | | | ENGINEER).OTHERWISE, THE PERMIT CAN BE ISSUED BUT A | | | COMPLAINT WILL BE FILED WITH FBPE. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-29 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-29 |
Time |
11:09 |
Sent To |
Z |
|
| Notes |
| 2007-10-29 11:17:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)CERTIFICATE OF AUTHORIZATION REQUIRED TO PRACTICE | | | ARCHITECTURE THROUGH A COMPANY, FS481.219(2).A SET | | | HAS BEEN RETAINED. | | | | | | 2.)ALL INFORMATION REQUIRED BY FAC61G15-23.002 IS | | | REQUIRED TO BE ON EACH SHEET (ENGINEER). | | | | | | 3.)THE TOP OF RAIL IS SHOWN AS DISCONTINUOUS, BUT | | | HANDRAIL AND GUARDRAIL ARE SHOWN AT 3'6".CLARIFY. | | | | | | 4.)HANDRAIL CANNOT BE DISCONTINUOUS AS SHOWN; | | | EXTENSIONS REQUIRED FBC1009.11.4. | | | | | | 5.)DECLARE OCCUPANCY FBC CHAPTER 3.COMPLIANCE WITH | | | FBC1009.11.1 IS TO BE SHOWN ON THE PLAN. | | | | | | 6.)ON THE STAIR PLAN, SHOW REQUIRED HANDRAIL | | | EXTENSIONS AT THE TOP AND BOTTOM OF THE STAIRS, | | | FBC1009.11.5. | | | | | | 7.)SHOW EXTENSIONS ON THE PLAN AND PROVIDE AN | | | ELEVATION FOR EITHER THE W OR E SIDE, FBC1009.11.5. | | | | | | 8.)THE SITE PLAN IS NOT CONSISTENT WITH THE PLAN. | | | THE PLAN SHOWS AN L SHAPED STAIR, SITE PLAN SHOWS A | | | STRAIGHT RUN WITH A LANDING. | | | | | | 9.)DECLARE GOVERNING CODE. | | | | | | 10.)DECLARE WIND DESIGN CRITERIA FBC1603.1.4. | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2007-10-05 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2007-10-05 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2007-10-05 16:55:17 | HISTORIC APPROVED BYGJUDGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-14 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-14 |
Time |
12:39 |
Sent To |
Z |
|
| Notes |
| 2007-11-14 12:39:59 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-29 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-09 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2007-10-09 10:45:20 | TO "MISC" BOX#1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-16 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-16 |
Time |
08:49 |
Sent To |
B |
|
| Notes |
| 2007-11-16 08:50:05 | ***APPROVED - RESUB #1*** | | | | | | | | | SENT TO "B" - SH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-29 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-29 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2007-10-29 13:19:32 | ***FAILED*** | | | | | | | | | 1)INDICATE ON SITE PLAN THE SETBACK DIMENSIONS FROM | | | THE PROPOSED TO THE PROPERTY LINES.INDICATE THE | | | SEPARATION DISTANCE FROM THE PROPOSED STAIRWAY TO THE | | | OTHER EXISTING STRUCTURES. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |