Plan Review Details - Permit 07100196
| Plan Review Stops For Permit 07100196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-20 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-20 |
Time |
17:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-08 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-08 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2007-11-08 07:08:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | FROM PREVIOUS LIST: | | | | | | 4.PROVIDE THE DCA APPROVED PLANS FOR THE MANUFACTURED | | | BUILDING.THE REQUIRED STAMPS WERE NOT INCLUDED ON THE | | | PLANS PROVIDED. | | | | | | 5.PROVIDE THE DCA APPROVAL FOR THE MANUFACTURED | | | BUILDING.WWW.FLORIDABUILDING.ORG | | | | | | 2ND REVIEW - | | | | | | AS PER OUR CONVERSATION, ORIGINAL SIGNED, SEALED, DATED | | | PLANS ARE NOT REQUIRED FOR THE DCA APPROVED SHED, BUT | | | YOU MUST PROVIDE PLANS WITH THE FLORIDA STATE PLAN | | | REVIEW STAMPS ON THEM.THE STATE APPROVED PLANS, ALONG | | | WITH THE DCA APPROVAL, CAN BE FOUND BY SEARCHING | | | WWW.FLORIDABUILDING.ORG, MANUFACTURED BUILDINGS. PLEASE | | | PRINT ALL REQUIRED PAPERWORK, TWO SETS.FS553.80. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-23 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2007-10-23 16:33:53 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.SHOW THE DISTANCE BETWEEN THE SHED AND THE PROPERTY | | | LINES. | | | | | | 2.THE ENGINEERING FIRM HANEY & ASSOCIATES, INC. IS TO | | | HAVE A CERTIFICATE OF AUTHORIZATION TO PRACTICE | | | ENGINEERING IN FLORIDA, FS471.023.THE PLANS HAVE BEEN | | | RETAINED. | | | | | | 3.THE ENGINEER'S SIGNATURE IS TO BE AN ORIGINAL PER | | | FBPE, FAC61G15-23.002.A STAMP WAS USED FOR THE | | | ENGINEER'S SIGNATURE. | | | | | | 4.PROVIDE THE DCA APPROVED PLANS FOR THE MANUFACTURED | | | BUILDING.THE REQUIRED STAMPS WERE NOT INCLUDED ON THE | | | PLANS PROVIDED. | | | | | | 5.PROVIDE THE DCA APPROVAL FOR THE MANUFACTURED | | | BUILDING.WWW.FLORIDABUILDING.ORG | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
15:01 |
Sent To |
B |
|
| Notes |
| 2007-11-16 15:01:29 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-02 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-02 |
Time |
11:04 |
Sent To |
Z |
|
| Notes |
| 2007-11-02 11:04:45 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-05 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2007-10-05 15:02:02 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-07 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-07 |
Time |
14:32 |
Sent To |
B |
|
| Notes |
| 2007-11-07 14:32:40 | ***APPROVED - RESUB #1*** | | | | | | SENT TO "B" - SH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-11 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-11 |
Time |
11:13 |
Sent To |
B |
|
| Notes |
| 2007-10-11 11:14:46 | ***FAILED*** | | | | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED SHED | | | TO THE PROPERTY LINES.NOTE: MUST BE A MINIMUM OF 5'. | | | | | | 2)INDICATE SEPARATION DISTANCE FROM PRINCIPAL | | | STRUCTURE TO THE PROPOSED SHED. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 | | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |