| Plan Review Stops For Permit 07100123 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-12-20 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-12-20 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-10-26 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-10-23 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2007-10-26 12:00:59 | PLEASE SEE THE BUILDING REVIEWER COMMENTS REGARDING THE | | | TWO BUILDINGS 5 & 6 RIGHT ACROSS FROM EACH OTHER. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | 2007-10-04 11:28:43 | PCN ON APPL WAS CLOSED OUT & TEMPORARY PCN HAS | | | DIFFERENT INFO FORWARDED COPY OF APPL TO S PALMER & | | | LILI URSU ALSO THERE ARE NO UNITS CREATED FOR DIFFERENT | | | BLDGS ON THIS PARCEL AT THIS TIME |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-20 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-20 |
Time |
18:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-18 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-18 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2007-12-18 11:48:31 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | | | | 2.PROVIDE REMOVAL INSTRUCTIONS TO SHOW COMPLIANCE | | | WITH FBC3105.4.2.1.THE INSTRUCTIONS SHOULD CONSIST OF | | | A SERIES OF PHOTOGRAPHS.THIS IS TO BE APPROVED BY THE | | | BUILDING OFFICIAL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-23 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2007-10-23 16:39:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.THE WIND DESIGN CRITERIA IS NOT READABLE DUE TO THE | | | WAY THAT THE PLANS WERE STAPLED.PLEASE MAKE SURE THAT | | | ALL REQUIRED INFORMATION IS AVAILABLE FOR REVIEW. | | | | | | 2.PROVIDE REMOVAL INSTRUCTIONS TO SHOW COMPLIANCE | | | WITH FBC3105.4.2.1.THE INSTRUCTIONS SHOULD CONSIST OF | | | A SERIES OF PHOTOGRAPHS.THIS IS TO BE APPROVED BY THE | | | BUILDING OFFICIAL. | | | | | | 3.CALCULATIONS ARE TO SIGNED, SEALED, AND DATED ON | | | EACH SHEET, WITH ALL INFORMATION REQUIRED FOR THE | | | ENGINEER ON EACH SHEET, OR AN INDEX SHEET USED, | | | FAC61G15-23.002. | | | | | | 4.ON THE ELEVATIONS AND SITE PLAN, SHOW THE AWNING | | | LOCATIONS. | | | | | | 5.SEPARATE PERMITS REQUIRED FOR THE TWO BUILDINGS. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-03 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-03 |
Time |
15:32 |
Sent To |
Z |
|
| Notes |
| 2007-12-03 15:32:24 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-05 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2007-10-05 10:25:44 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-12-11 |
Time |
20:55 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-12-11 |
Time |
20:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-10-16 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-10-16 |
Time |
18:00 |
Sent To |
B |
|
| Notes |
| 2007-10-16 18:44:51 | ***FAILED*** | | | | | | 1) PLEASE INDICATE THE LOCATION, DIMENSIONS, ETC. OF | | | THE AWNINGS ON THE ELEVATIONS AND SITE PLAN. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|