| Plan Review Stops For Permit 07100103 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-28 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-28 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2008-01-28 16:46:18 | REV OK (ADDED WINDOWS/SHUTTERS TO SCOPE OF WORK) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-15 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-15 |
Time |
17:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-23 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-23 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2007-10-23 09:04:23 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | **FROM PREVIOUS LIST, NOT ADDRESSED** | | | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2.PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE ATTACHED INSTALLATION SCHEDULE. | | | IF THIS JOB FALLS UNDER THE EXCEPTION FBC EB 507.3, | | | PROVIDE CALCULATIONS SHOWING THAT THE AGGREGATE GLAZED | | | AREA BEING REPLACED IS LESS THAN 25% OF THE TOTAL | | | AGGREGATE GLAZED AREA FOR THE DWELLING. | | | | | | THE PRODUCT APPROVALS SUBMITTED ARE FOR NON IMPACT | | | RATED WINDOWS (SEE HIGHLIGHTED PRODUCT APPROVAL).IF | | | YOU ARE REPLACING LESS THAN 25% OF THE AGGREGATE GLAZED | | | AREA IN A 12 MONTH PERIOD, THEN THE JOB IS EXEMPT FROM | | | IMPACT REQUIREMENTS BUT YOU MUST PROVIDE CALCULATIONS | | | (TOTAL AGGREGATE GLAZED AREA, TOTAL OF AREA BEING | | | REPLACED).OTHERWISE, IMPACT PROTECTION (SHUTTERS) | | | WILL BE REQUIRED.IF SHUTTERS ARE REQUIRED, SUBMIT TWO | | | SETS OF PRODUCT APPROVALS AND TWO SETS A COMPLETED | | | INSTALLATION SCHEDULE (SEE ATTACHED). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-10 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-10 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2007-10-10 14:11:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | ***WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED | | | ITEMS APPLY*** | | | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | ____2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES | | | FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED | | | USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2.PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE ATTACHED INSTALLATION SCHEDULE. | | | IF THIS JOB FALLS UNDER THE EXCEPTION FBC EB 507.3, | | | PROVIDE CALCULATIONS SHOWING THAT THE AGGREGATE GLAZED | | | AREA BEING REPLACED IS LESS THAN 25% OF THE TOTAL | | | AGGREGATE GLAZED AREA FOR THE DWELLING. | | | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 505.1. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-15 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-15 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2007-11-15 18:00:30 | HISTORICAL APPROVAL PER JILLIAN PAPA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-28 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-28 |
Time |
10:22 |
Sent To |
B |
|
| Notes |
| 2008-01-28 10:22:39 | TO "SHILL' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-08 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-08 |
Time |
13:42 |
Sent To |
B |
|
| Notes |
| 2007-11-08 13:42:39 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-17 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-17 |
Time |
16:57 |
Sent To |
B |
|
| Notes |
| 2007-10-17 16:57:57 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-10 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-05 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2007-10-05 09:07:43 | TO "MISC" BOX#1 |
|
|