| Plan Review Stops For Permit 07100054 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-03 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-03 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2008-10-03 08:43:06 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | | | | 1. DESIGN PRESSURE SPECIFIED BY ENGINEER IS -67.9, BUT | | | THE CHART FOR -40 TO -60PSF WAS USED (SHEETS 10 AND | | | 16). THE CHART FOR DESIGN PRESSURES -60 TO -90 ON | | | SHEETS 10 AND 17 SHOULD BE USED. PLEASE REVISE | | | INSTALLATION SCHEDULE. | | | | | | 2. SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE | | | WITH THE ANCHOR SCHEDULES. IN THIS CASE, IT APPEARS | | | THAT YOU ARE USING 8 TOP, ALT 8 BOTTOM. PLEASE NOTE | | | THAT THIS REVIEW WOULD NOT HAVE FAILED FOR THIS REASON | | | ONLY, BUT SPECIFYING THE INFORMATION CORRECTLY ASSISTS | | | THE PLAN REVIEWER. AS THE INSTALLATION SCHEDULE MUST BE | | | REVISED DUE TO OTHER COMMENTS, PLEASE REVISE THIS | | | COLUMN. | | | | | | 3. A 2" EDGE DISTANCE FOR BLOCK REQUIRES A FACTOR OF | | | .5, SEE SHEET 10. PLEASE REVISE INSTALLATION SCHEDULE. | | | | | | DUE TO THE NUMBER OF TIMES THIS REVISION HAS FAILED, IT | | | IS SUGGESTED THAT THE QUALIFIER CONTACT ME PRIOR TO | | | RESUBMITTAL. IF THE QUALIFIER CONTACTS ME, I WOULD | | | SCHEDULE AN APPOINTMENT TO DO A PRELIMINARY REVIEW | | | PRIOR TO RESUBMITTAL. THIS IS OPTIONAL, SUBJECT TO THE | | | QUALIFIER'S DISCRETION. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-11 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-11 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2008-07-11 13:45:47 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.TWO COMPLETE COLLATED SETS REQUIRED FOR PERMIT | | | ISSUANCE.A PHOTOCOPY MACHINE HAS BEEN PROVIDED IN THE | | | LOBBY FOR THIS PURPOSE. | | | | | | 2ND REVISION REVIEW, ONLY ONE SET OF FLOOR PLAN AND | | | INSTALLATION SCHEDULE PROVIDED.THIS CANNOT BE ISSUED | | | UNLESS TWO COMPLETE SETS PROVIDED. | | | | | | 2.ON THE PRODUCT APPROVAL, YOU'VE HIGHLIGHTED THE | | | MOUNTING DETAILS ALTERNATIVE 1, 3A (OPTION 2), 3, AND | | | 8.ON SHEETS 16 AND 17, WALL MOUNT 5, 2, 3A, AND 9 | | | HAVE BEEN HIGHLIGHTED.THE INSTALLATION SCHEDULE | | | SPECIFIES "WALL MOUNTING INSTALL A", WHICH IS NOT ONE | | | OF THE CHOICES ON THIS PRODUCT APPROVAL.PLEASE | | | CORRELATE. THE ANCHOR SPACING REQUIRED CANNOT BE | | | REVIEWED WITHOUT THIS INFORMATION. | | | | | | ALSO PLEASE NOTE THAT MARKING THE PRODUCT APPROVAL IS | | | HELPFUL AS IT ASSISTS WITH PLAN REVIEW AND INSPECTIONS, | | | BUT IF YOU DO THIS, IT MUST BE CODE COMPLIANT AND | | | CORRELATE WITH THE JOB.HIGHLIGHTER CANNOT BE USED TO | | | SHOW CODE COMPLIANCE AS IT DOES NOT APPEAR WHEN | | | SCANNED.THE INFORMATION ON THE INSTALLATION SCHEDULE | | | IS REQUIRED BY BUILDING OFFICIAL'S POLICY. | | | | | | 2ND REVISION REVIEW, VARIOUS DETAILS AND ANCHOR SPACING | | | WERE HIGHLIGHTED THROUGHOUT THE PRODUCT APPROVAL, | | | INCLUDING 9" ANCHOR SPAC ING.INSTALLATION SCHEDULE | | | SPECIFIES "WALL MOUNT A" WHICH I CANNOT LOCATE IN THE | | | PRODUCT APPROVAL, WITH 11" SPACING.REVISE THE SHUTTER | | | CONNECTION MOUNTING TYPE TO CORRELATE WITH THE | | | CONNECTION TYPE YOU PROPOSE TO USE. | | | | | | 3.ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-11 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2008-03-11 14:35:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.TWO COMPLETE COLLATED SETS REQUIRED FOR PERMIT | | | ISSUANCE.A PHOTOCOPY MACHINE HAS BEEN PROVIDED IN THE | | | LOBBY FOR THIS PURPOSE. | | | | | | 2.ON THE PRODUCT APPROVAL, YOU'VE HIGHLIGHTED THE | | | MOUNTING DETAILS ALTERNATIVE 1, 3A (OPTION 2), 3, AND | | | 8.ON SHEETS 16 AND 17, WALL MOUNT 5, 2, 3A, AND 9 | | | HAVE BEEN HIGHLIGHTED.THE INSTALLATION SCHEDULE | | | SPECIFIES "WALL MOUNTING INSTALL A", WHICH IS NOT ONE | | | OF THE CHOICES ON THIS PRODUCT APPROVAL.PLEASE | | | CORRELATE. THE ANCHOR SPACING REQUIRED CANNOT BE | | | REVIEWED WITHOUT THIS INFORMATION. | | | | | | ALSO PLEASE NOTE THAT MARKING THE PRODUCT APPROVAL IS | | | HELPFUL AS IT ASSISTS WITH PLAN REVIEW AND INSPECTIONS, | | | BUT IF YOU DO THIS, IT MUST BE CODE COMPLIANT AND | | | CORRELATE WITH THE JOB.HIGHLIGHTER CANNOT BE USED TO | | | SHOW CODE COMPLIANCE AS IT DOES NOT APPEAR WHEN | | | SCANNED.THE INFORMATION ON THE INSTALLATION SCHEDULE | | | IS REQUIRED BY BUILDING OFFICIAL'S POLICY. | | | | | | 3.THIS WAS BROUGHT IN AS A SUBMITTAL, BUT IS A | | | REVISION.ALL CHANGES TO AN ISSUED PERMIT WOULD BE | | | CONSIDERED A REVISION WITH ASSOCIATED FEES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-03 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-03 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-05 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-05 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2007-11-05 14:54:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | | | | | NEW COMMENT: | | | | | | ALL INFORMATION REQUIRED BY FAC61G15-23.002 IS TO BE ON | | | EACH SHEET (CERTIFICATE OF AUTHORIZATION FOR | | | ENGINEER). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-10 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-10 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2007-10-10 15:43:03 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | | R310. | | | | | | ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | | ABOVE. | | | | | | _XX_8.PLEASE CLARIFY, IS THIS THREE STORY BUILDING | | | A RESIDENCE? | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-30 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-30 |
Time |
13:01 |
Sent To |
B |
|
| Notes |
| 2008-09-30 13:01:47 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-30 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-30 |
Time |
16:11 |
Sent To |
B |
|
| Notes |
| 2008-06-30 16:11:28 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-07 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-07 |
Time |
09:59 |
Sent To |
B |
|
| Notes |
| 2008-03-07 09:59:41 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-27 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2007-11-27 14:14:28 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-26 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-26 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
| 2007-10-26 10:44:42 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-10 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-03 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2007-10-03 12:44:00 | TO "MISC "BOX#1 |
|
|