Plan Review Details - Permit 07100039
Plan Review Stops For Permit 07100039
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-12-11 Cont ID  
Sent By jwitmer Date 2007-12-11 Time 09:01 Rev Time 0.77
Received By jwitmer Date 2007-12-11 Time 09:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-11-14 Cont ID  
Sent By jwitmer Date 2007-11-14 Time 15:07 Rev Time 0.00
Received By jwitmer Date 2007-12-11 Time 09:00 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-02 Cont ID  
Sent By jwitmer Date 2007-10-02 Time 21:04 Rev Time 2.00
Received By jwitmer Date 2007-10-02 Time 20:40 Sent To  
Notes
2007-10-02 22:29:33BUILDING PLAN REVIEW
 PERMIT: 07100039
 ADD: 700 S ROSEMARY AVE # 132
 CONT: ANDERSON- MOORE CONSTRUCTION
 TEL: (561)662-1819
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A
 RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD
 BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE
 SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT
 ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTSWEST PALM
 BEACH ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 2)TS SHEET AND ARCHITECTURAL SHEETS, ROSENTHAL
 ASSOCIATES, LLC ARE MISSING THEIR CERTIFICATE OF
 AUTHORIZATION. 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET BEARING
 THE NAME OF AN ARCHITECT PRACTICING UNDER A FICTITIOUS
 NAME, A CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE THE CERTIFICATE
 OF AUTHORIZATION
 NUMBER.TS SHEET AND ARCHITEC) 61G1-16.004FL.
 ADMIN. CODE.PLANS PREPARED BY A REGISTERED ARCHITECT
 SHALL INCLUDE A TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND TELEPHONE
 NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND
 DATED SEAL
 - INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING
 THE PLANS.
  
 3) TS SHEET CODE AND STORE DATA: STATED THEWRONG
 BUILDING TYPE: TYPE BUILDING IS I-B THE 5 STORY PARKING
 GARAGE AND B-BLOCK ARE ONE BUILDING NOT TWO!
  
 4) TS SHEET GOVERNING CODES PLEASE CORRECT, THE 2004
 FBC WITH 2007 CODE REVISIONS WHEN SUBMIITED FOR PERMIT
 AFTER JULY 1, 2007.
  
 5) SHEET S1 COLUMBIA ENGINEERING IS ALSO MISING THEIR
 CERTIFICATE OF AUTHORIZATION,471.023 F.S. CERTIFICATE
 OF AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET
 BEARING THE NAME OF AN ENGINEER PRACTICING UNDER A
 FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP,
 OFFERING ENGINEERING SERVICES, SHALL INCLUDE THE
 CERTIFICATE OF AUTHORIZATION NUMBER.
  
 6) SHEET S-1 INDICATES VARIOUS TIE DOWN STRAPS AS WELL
 AS A3.1 INDICATES THE USE OF BAHAMA STYLE SHUTTERS.
 PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT
 IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT
 HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR
 LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72.
  
 7) FBC 106.3 PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 8) ADDITIONAL INFORMATION REQUIRED, THE BAHAMA STYLE
 STORM SHUTTERS ARE THEY GOING TO BE DROPPED IN A CASE
 OF A HIGH WIND EVENT OR ARE THEY GOING TO BE LEFT IN
 THE OPEN FIXED POSITION?
 IF LEFT IN THE FIXED POSITION, THE PRODUCT APPROVAL
 HAVEN'T BEEN TESTED IN THIS MANNER AND WILL NEED AN
 ENGINEER TO DO A RATIONAL ANYLSIS ON THE LISTED
 FASTENERS AND FATENING SCHEDULE FOR 140 MPH. 106.1.2
 FBC
  
 9) COMMENT # 10 FROM CAPRIS' REVIEW STILL HAS NOT BEEN
 ADDRRESED, THE MIRROR IN THE HANDICAPPED DRESSING ROOM
 HAS NOT BEEN MOVED TO DIRECTLY ACROSS FROM THE BENCH,
 11-4.35.5 MIRROR. WHERE MIRRORS ARE PROVIDED IN
 DRESSING ROOMS OF THE SAME USE, THEN IN AN ACCESSIBLE
 DRESSING ROOM, A FULL-LENGTH MIRROR, MEASURING AT LEAST
 18 INCHES WIDE BY 54 INCHES HIGH (460 MM BY 1370 MM),
 SHALL BE MOUNTED IN A POSITION AFFORDING A VIEW TO A
 PERSON ON THE BENCH AS WELL AS TO A PERSON IN A
 STANDING POSITION.
  
 10A) THE HANDICAPPED DRESSING ROOM DOOR SWINGS INTO THE
 REQUIRED T-SHAPED SPACEPLEASE SEE 11-4.35.2 NO DOOR
 SHALL SWING INTO ANY PART OF THE REQUIRED TURNING
 SPACE.
  
 10B) NOTE THE E1.1 SHEET HAS THE HANDICAPPED BENCH ON A
 DIFFERENT WALL THAN THE A SHEETS, PLEASE CORRALATE,
 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 10C) E1.1 THE WATER FOUNTAINS ALSO HAD NOT BEEN MOVED
 ON THIS SHEET, PLEASE CORRALATE, 106.1.2.
  
 11) SHEET A1.1 REAR EXIT DOOR, THE PLANS INDICATES
 HASHED LINES AND STORAGE AREA WALLS IN FRONT OF THE
 REAR EXIT, IS THE INTENT TO BLOCK OFF THE REAR EXIT?
 COMMON PATH OF TRAVEL FOR FIRE SPRINKLED BUILDINGS IS
 100' , THIS TENANT SPACE WOULD REQUIRE 2 EXITS.1013.3
 EXCEPTION(5).
  
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
  
  
  
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-12-03 Cont ID  
Sent By dpalmer Date 2007-12-03 Time 12:54 Rev Time 0.00
Received By dpalmer Date 2007-12-03 Time 12:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-11-09 Cont ID  
Sent By dpalmer Date 2007-11-08 Time 09:38 Rev Time 0.00
Received By dpalmer Date 2007-11-08 Time 09:38 Sent To  
Notes
2007-11-09 16:16:24** DENIED ***
  
  
 1) NOTE: ELECTRICAL REVIEW STATUS HAS CHANGED TO
 FAILED.
 REVIEW CONDUCTED BY THE MECHANICAL REVIEWER INDICATES
 THE AIR CONDITIONING SYSTEMS AS CHILLED WATER, HOWEVER
 ELECTRICAL PLANS INDICATE A SPLIT SYSTEM.
 THESE PLANS WILL BE BECOME VOID AND STAMPED AS SUCH
 UNTIL COORDINATION OF ELECTRICAL PLANS AND MECHANICAL
 PLANS IS DONE.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-10-02 Cont ID  
Sent By dpalmer Date 2007-10-02 Time 16:58 Rev Time 0.00
Received By dpalmer Date 2007-10-02 Time 16:56 Sent To  
Notes
2007-10-02 16:58:51** DENIED ***
  
 FRESH PRODUCE CLOTHING STORE:
  
 1) NOTE: PLEASE BE SURE TO COORDINATE ACTUAL SUITE
 NUMBER ONTO TITLE BLOCKS OF PLANS INCLUDING TITLE COVER
 SHEET.
 SHOWS SUITE B-13, WHEN THE SUITE/UNIT # IS 132. PLEASE
 ADJUST.
 FAC 61G1-16.004, 61G15-23.002, FBC 110.1.2, 106.1.2
  
 2) NOTE: PLEASE SEE MISSING LICENSE INFORMATION FOR
 ARCHITECTURAL FIRM AS REQUIRED UNDER FLORIDA
 ADMINISTRATIVE CODE 61G1-16.004 AND AS REQUIRED PER
 FLORIDA STATUTES 481.219.
 THIS IS REQUIRED FOR ALL TRADES AND FOR ALL SHEETS
 WHICH CONTAINS REFERENCE TO THIS FIRM.
 THIS IS KNOWN AS THE CERTIFICATE OF AUTHORIZATION
 NUMBER OBTAINED THROUGH THE DEPARTMENT OF BUSINESS AND
 PROFESSIONAL REGULATION.
  
 3) NOTE: PLEASE SEE THE ENGINEERING FIRM AS LISTED ON
 THE TITLE SHEET (TS) IS NOT THAT OF THE SAME
 ENGINEERING FIRM LISTED ON ELECTRICAL SHEETS. PLEASE
 CLARIFY WHICH FIRM IS BEING THE RESPONSIBLE DESIGNER OF
 RECORD.
 PLEASE SEE THIS FIRM AS LISTED ON SHEET TS IS MISSING
 RELEVANT LICENSE INFORMATION PER FAC 61G15-23.002 AND
 FS 471.023.
 THIS IS REQUIRED FOR ALL TRADES AND FOR ALL SHEETS
 WHICH CONTAINS REFERENCE TO THIS FIRM.
 THIS IS KNOWN AS THE CERTIFICATE OF AUTHORIZATION
 NUMBER OBTAINED THROUGH THE DEPARTMENT OF BUSINESS AND
 PROFESSIONAL REGULATION.
  
 4) NOTE: PLEASE SEE BUILDING REVIEW NOTES FOR SHEET S-1
 AND MISSING CERTIFICATE OF AUTHORIZATION NUMBER PER FAC
 61G15-23.002, FS 471.023.
 ** THIS IS BEING NOTED FOR INFORMATION ONLY AND TO SEE
 BUILDING REVIEW NOTES*
  
 5) NOTE: PLEASE SEE THE FIXTURE LEGEND AS SUBMITTED AND
 SHOWN ON SHEET A1.2 AND E1.1 DO NOT CORRELATE. PLEASE
 COORDINATE THE TWO AND ADJUST ANY LIGHTING PERFORMANCE
 CALCULATIONS ETC WHICH MAY CHANGE BASED ON THE
 FIXTURES.
 FBC 13-415.2
 FBC 106.1.2 ADMIN SECTION FOR COORDINATION.
  
 6) NOTE: PLEASE PROVIDE INFORMATION ON THE OVER RIDE
 SWITCH DEVICES BEING NOTED FOR EACH CONTACTED AT THE
 CASH-WRAP DESK LOCATIONS. PLEASE SEE FBC
 13-415.1.ABC.1.1, .1.2.
 PLEASE KNOW ANY OVER RIDES DEPENDING ON TYPE OF DEVICE
 ARE LIMITED TO THE TIMES OF OVER RIDES.
 PLEASE KNOW AS THE LIGHTING IN THE REAR OF SPACE IS
 SHOWN AS EXISTING,IF THE SWITCHES AS SHOWN ARE GOING
 TO BE NEW, THESE WOULD ALSO NEED TO COMPLY TO THE
 SECTIONS AS NOTED ABOVE PER CHAPTER 13 FOR LIGHTING
 CONTROLS. (ONLY IF NEW) 13-101. THE EXISTING RESTROOMS
 DO INDICATE *E* FOR THE EXISTING CONTROLS FOR LIGHTING.
 PLEASE SEE REAR ENTRANCE INTO SPACE.
 PLEASE CLARIFY AND STATE/ADJUST ACCORDINGLY.
  
 7) NOTE: PLEASE SEE LIGHTING CONTACTOR CIRCUITS SHOWN
 ON C-1 WHICH SEEMS TO LIST 2-2 TWICE. AS PER PLANS AND
 THE LOCATION AND IDENTIFICATION OF CIRCUITS AT FRONT
 DOOR LOCATION THIS SEEMS THIS SHOULD BE 2-2, 2-4 AND
 2-6? PLEASE CLARIFY AND CORRELATE.
  
 8) NOTE: PLEASE SEE TRACK LIGHTING LOADS AS SHOWN ON
 FIXTURE LEGEND AND PER 220.43B DO NOT SEEM TO MATCH THE
 ACTUAL AMPERAGE LOAD FOR ALL CIRCUITS AS SHOWN ON PANEL
 SCHEDULE 2. PLEASE SEE CIRCUIT 2-16 FOR EXAMPLE AS THIS
 ONLY INDICATES 7.5AMPS FOR LOAD.
 PLEASE SEE OTHER CIRCUITS WITH THE SAME LENGTH OF TRACK
 AND FIXTURES INDICATE 12.5AMPS FOR THE SAME? PLEASE
 CORRELATE AND ADJUST AS NEEDED.
 FBC 106.1.2, 106.3.5.1.2
 NEC 408.4, 215.5, 220 ETC.
  
 8) NOTE: PLEASE SEE E0.2 AS THE COLOR CODING IS NOTED
 FOR 277/480V AS (A) YELLOW, (B) BROWN, (C) ORANGE.
 PLEASE KNOW THE COLOR CODING FOR 277/480V SYSTEMS IN
 THE CITY OF WEST PALM BEACH SHALL BE BROWN (A), PURPLE
 (B) AND YELLOW (C).
 PLEASE SEE THE NEC ONLY INDICATES COLOR CODING OF
 ORANGE FOR A HIGH-LEG.
 PLEASE KNOW AS THE EXISTING BUILDINGS LOCATED IN THE
 CITY OF WEST PALM BEACH AND THIS LOCATION ALREADY
 CONTAINS CONDUCTORS FOR FEEDERS AND SERVICE AS BROWN,
 PURPLE, YELLOW, ANY NEW WOULD NEED TO MATCH.
 THE PLANS MENTIONS ALL EXISTS FOR THESE CONDUCTORS AND
 THIS NOTE ON E0.2 SHOULD NOT AFFECT THIS PROJECT.
 PLEASE KNOW THAT ANY CHANGES WOULD REQUIRE THESE COLOR
 CODING.
 NEC 90.4.
  
 ** PLEASE BE SURE TO SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL PLANS.
 IF THERE ARE ANY QUESTIONS, PLEASE CONTACT THIS
 OFFICE/REVIEWER.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-12-11 Cont ID  
Sent By mawillia Date 2007-12-11 Time 17:26 Rev Time 0.00
Received By mawillia Date 2007-12-11 Time 16:38 Sent To  
Notes
2007-12-11 17:26:01*****APPROVED*****
  
 ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ADDRESSED;PLAN SHEETS A1.3, A3.1, AND E1.1 WERE
 STAMPED, INITIALED, AND DATED.
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-11-13 Cont ID  
Sent By mawillia Date 2007-11-13 Time 11:38 Rev Time 0.00
Received By mawillia Date 2007-11-13 Time 10:42 Sent To  
Notes
2007-11-13 11:37:56*****UNSAT*****
  
  
 *THE FOLLOWING COMMENT TAKEN FROM THE PREVIOUS FIRE
 PLAN REVIEW STILL NEED TO BE ADDRESSED:
  
 4.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS
 TO COMPLY WITH NFPA 241.ADD NFPA 241 TO CODE DATA,
 SHEET TS1
  
 *NEW COMMENT
  
 A.ON VARIOUS PLAN SHEETS ( I.E. A1.2) AN EXIT LIGHT
 IS SHOWN ON BOTH SIDES OF DOOR #105.REMOVE EXIT SIGN
 ON STORAGE SIDE, AS EGRESS FROM THIS AREA SHOULD BE AT
 THE REAR EXIT (DOOR #106).
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-10-04 Cont ID  
Sent By mwennerg Date 2007-10-04 Time 10:54 Rev Time 0.00
Received By mwennerg Date 2007-10-04 Time 10:54 Sent To  
Notes
2007-10-04 11:25:57***DENIED***
  
 1) MORE INFORMATION IS REQUIRED REGARDING THE REAR
 EXIT. MEANS OF EGRESS WOULD SUGGEST PERSONS PASSING
 THROUGH TWO (2) STORAGE ROOMS WITH THE POSSIBILITY OF
 BATHROOM DOORS CAUSING AN OBSTRUCTION. PLEASE SHOW
 COMPLIANCE WITH NFPA 101, SEC. 7.5.1.6.
  
 2) ILLUSTRATE AN ADDRESS ON THE BUILDING NEW OR
 EXISTING THAT COMPLIES WITH CITY OF WEST PALM BEACH
 REQUIREMENTS FOR COMMERCIAL BUILDINGS. CHARACTERS TO BE
 MINIMUM OF 6"IN HEIGHT AND CONTRASTING TO THE
 BACKGROUND. SUITE NUMBERS TO BE AT LEAST 3" IN HEIGHT.
 SHEET A3.1
  
 3) DUCT SMOKE DETECTORS TO BE LOCATED IN SUPPLY DUCT
 AND SHALL INITIATE A GENERAL FIRE ALARM IN ACCORDANCE
 WITH LOCAL REQUIREMENTS.
  
 4) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
 5) PLEASE INDICATE MINIMUM INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILING IN TERMS OF CLASS
 A,B OR C.
  
 6) BUILDING FIRE PROTECTION EQUIPMENT SHALL BE
 MAINTAINED DURING WORK.
  
 7) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE
 SPRINKLER AND FIRE ALARM REMODEL. PLANS MENTION FIRE
 ALARM EQUIPMENT BUT THIS IS NOT SHOWN ON DRAWINGS.
 SHEET E1.1
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-02-19 Cont ID  
Sent By adarroug Date 2008-02-19 Time 08:21 Rev Time 0.00
Received By adarroug Date 2008-02-19 Time 08:21 Sent To M
Notes
2008-02-19 08:21:30TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-03 Cont ID  
Sent By adarroug Date 2007-12-03 Time 10:08 Rev Time 0.00
Received By adarroug Date 2007-12-03 Time 10:08 Sent To  
Notes
2007-12-03 10:09:10TO "COMM" BD#9--PRIVATE PROVIDER--NEW SHEETS FOR ALL
 TRADES

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-06 Cont ID  
Sent By adarroug Date 2007-11-06 Time 08:53 Rev Time 0.00
Received By adarroug Date 2007-11-06 Time 08:53 Sent To  
Notes
2007-11-06 08:54:31TO "COMM" BD#27--PRIVATE PROVIDER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-05 Cont ID  
Sent By lmartine Date 2007-10-05 Time 17:40 Rev Time 0.00
Received By lmartine Date 2007-10-02 Time 12:42 Sent To  
Notes
2007-10-02 12:43:34TO "COMM" BD#41 ***PRIVATE PROVIDER***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2008-03-11 Cont ID  
Sent By rregueir Date 2008-03-11 Time 13:38 Rev Time 0.00
Received By rregueir Date 2008-03-11 Time 13:38 Sent To  
Notes
2008-03-11 13:39:03MECH REV #5 ADDED FIRE DAMPERS AT STORAGE ROOM.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2008-02-26 Cont ID  
Sent By rregueir Date 2008-02-26 Time 11:04 Rev Time 0.00
Received By rregueir Date 2008-02-26 Time 10:31 Sent To PC
Notes
2008-02-26 11:04:45REVIEW #: REV.4
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. FIRE/SMOKE DAMPERS ARE SHOWN WHERE DUCTS PENETRATE A
 1-HOUR RATED WALL ASSEMBLY. IT IS NOT CLEAR WHY
 FIRE/SMOKE DAMPERS ARE SHOWN AT THIS LOCATON AS THIS IS
 NOT A SMOKE BARRIER. IN FACT, IT IS NOT CLEAR WHY THIS
 WALL IS RATED AT ALL. THE STORAGE ROOMS MEET THE
 CRITERIA FOR ACCESSORY USE AREAS IN ACCORDANCE WITH
 FBCB 302.2 AND THEREFORE NO RATED SEPARATION IS
 REQUIRED. THE DESIGNER CAN DESIGN ABOVE WHAT THE CODE
 REQUIRES. HOWEVER, FIRE/SMOKE DAMPERS, WHETHER REQUIRED
 OR NOT SHALL BE INSTALLED PER THEIR LISTING,
 MANUFACTURER'S INSTALLATION INSTRUCTIONS AND FBCM
 SECTION 607 IN ACCORDANCE WITH FBCM 607.2.
  
 2. PLANS DO NOT INDICATE HOW THE SMOKE DAMPERS ARE TO
 BE CONTROLLED. SMOKE DAMPERS SHALL BE CONTROLLED BY ONE
 OR A COMBINATION OF METHODS IN ACCORDANCE WITH FBCM
 607.3.2.1. IF SMOKE DAMPERS ARE TO REMAIN, SHOW
 COMPLIANCE WITH THIS SECTION.
  
 NOTE: ANY CHANGES TO THE MECHANICAL PLANS RELATED TO
 THE LOCATION OF OR THE NEED FOR DAMPERS AT DUCT
 PENETRATIONS OF THE STORAGE ROOM WALLS SHOULD BE
 COORDINATED WITH ARCHITECTURAL PLANS. ANY CHANGES TO
 ARCHITECTURAL PLANS SHALL BE SUBMITTED FOR BUILDING
 PLAN REVIEW IN CONJUNCTION WITH RESUBMITTED MECHANICAL
 PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-12-03 Cont ID  
Sent By rregueir Date 2007-12-03 Time 11:28 Rev Time 0.00
Received By rregueir Date 2007-12-03 Time 11:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-11-09 Cont ID  
Sent By rregueir Date 2007-11-09 Time 16:41 Rev Time 0.00
Received By rregueir Date 2007-11-09 Time 15:28 Sent To  
Notes
2007-11-09 16:41:13REVIEW #: 2ND
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN
 RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. OK
  
 2. OK
  
 3. OK
  
 4. AH-1 IS STILL LISTED, BASED ON MODEL NUMBER, AS A
 CHILLED WATER AHU. PLAN STILL INDICATES THAT THERE IS
 AN EXISTING CONDENSING UNIT ON THE ROOF. ELECTRICAL
 PLANS STILL SHOW THERE IS ELECTRICAL SERVICE FOR A
 CONDENSING UNIT ON THE ELECTRICAL PANEL. AT LEAST ONE
 PIECE OF THIS INFORMATION IS INCORRECT. AS STATED IN
 PREVIOUS REVIEW COMMENT, THIS IS EITHER A CHILLED WATER
 SYSEM WITH NO CONDENSER (AS INDICATED BY AHU MODEL
 NUMBER) OR A SPLIT SYSTEM WITH THE WRONG AHU LISTED ON
 PLANS. PLEASE COORDINATE INFORMATION ON MECHANICAL
 PLANS REGARDING THE TYPE OF EQUIPMENT BEING USED. ALSO,
 IF IT IS DETERMINED THAT THERE IS NO CONDENSING UNIT,
 PLEASE COORDINATE WITH ELECTRICAL PLANS. SEE ATTACHED
 MANUFACTURER'S DATS FOR THE CARRIER 40RMS012 AIR
 HANDLER.
  
 5. OK
  
 6. DO THE AIR HANDLER AND EXHAUST FANS RUN CONTINUOUS?
 IF NOT, HOW WILL AIR BE PROVIDED WHENEVER THE RESTROOMS
 ARE OCCUPIED? SHOW COMPLIANCE WITH FBC,M 401.3 WHICH
 REQUIRES VENTILATION TO BE PROVIDED WHENEVER THE SPAE
 IS OCCUPIED. ALSO, OUTSIDE AIR CALCULATIONS STATE THAT
 OUTSIDE AIR FOR THE RESTROOOMS IS BEING PROVIDED VIA
 TRANSFER AIR. FLOOR PLAN SHOWS BATHROOMS PROVIDED WITH
 MECHANICAL SUPPLY AIR. WHICH IS CORRECT? SHOW
 COMPLIANCE WITH FBC,M 403.1.
  
 7. OK
  
 8. NOT FOR OUTSIDE AIR DAMPER STATES THE DAMPER IS TO
 BE CLOSED WHEN THE UNIT IS HOT IN USE. PLEASE CLARIFY.
 THIS DAMPER SHOULD REMAIN OPEN WHENEVER THE SPACE IS
 OCCUPIED AND BE CLOSED DURING UNOCCUPIED HOURS. IF THE
 AHU HAS A NIGHT MODE WHERE IT MAY BE RUNNING DURING
 UNOCCUPIED HOURS, THE DAMPER SHOULD BE CLOSED DURING
 THAT TIME IN ACCORDANCE WITH FBC 13-409.1.ABC.3.3.
  
 9. OK
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-10-05 Cont ID  
Sent By rregueir Date 2007-10-05 Time 14:13 Rev Time 0.00
Received By rregueir Date 2007-10-05 Time 09:17 Sent To  
Notes
2007-10-05 14:12:58REVIEW #: 1
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. PG TS: PROJECT INFORMATION, ITEM 4 INDICATES
 AIR-ZONA SYSTEMS AS THE MEP ENGINEER. HOWEVER, PG MP1.1
 IS SIGNED AND SEALED BY YV KULKARNI, PE. PLEASE CORRECT
 INFORMATION ON FRONT PAGE. AIR-ZONA SYSTEMS
 ENGINEERING, INC'S CERTIFICATE OF AUTHORIZATION IS
 LISTED AS NULL AND VOID BY THE STATE OF FLORIDA DBPR.
  
 2. MP1.1: UOTSIDE AIR CALCULATIONS REFERENCE THE 2003
 IMC. PLEASE CORRECTLY REFERENCE 2004 FBC,M IN
 ACCORDANCE WITH FS 553.73.
  
 3. MP1.1: OUTSIDE AIR CALCULATIONS REFERENCE AN EXHAUST
 SCHEDULE. NO SUCH SCHEDULE COULD BE FOUND ON PLANS.
 PROVIDE MISSING INFORMATION AS COMPLIANCE WITH FBC,M
 TABLE 403.3 IS REQUIRED BY FBC,EB 609.1.
  
 4. MP1.1: EXISTING HVAC EQUIPMENT SCHEDULE LISTS A
 "CHILLED WATER SPLIT SYSTEM." THE EQUIPMENT SHOWN ON
 PLANS IS EITHER A SPLIT SYSTEM OR PART OF A CHILLED
 WATER SYSTEM. IT IS NOT BOTH. THE MODEL NUMBER LISTED
 ON PLAN FOR AH-1 INDICATES THIS IS A CHILLED WATER
 SYSTEM. THAT WOULD MEAN THAT THERE IS NO EXISTING ROOF
 MOUNTED CONDENSING UNIT INVOLVED IN THE SCOPE OF THIS
 WORK. ALSO, THERE IS NO AH-2 SHOWN ON PLANS. IT SHOULD
 NOT BE ON THE EXISTING EQUIPMENT SCHEDULE. PLEASE MAKE
 CORRECTIONS AND CLARIFY AS NEEDED TO ACCURATELY REFLECT
 THE SCOPE OF WORK AND EXISTING CONDITIONS. FBC
 106.1.1.
 NOTE: EXISTING CU-1 IS ALSO SHOWN OP PG E1.1.
 COORDINATE ANY CORRECTIONS ON THIS PAGE WITH ELECTRICAL
 PLANS.
  
 5. MP1.1: PLAN SHOWS DUCT SMOKE DETECTOR IN RETURN DUCT
 FOR UNIT SHUT DOWN. DUCT SMOKE DETECTORS SHALL BE
 INSTALLED IN SUPPLY AIR SYSTEMS IN ACCORDANCE WITH
 FBC,M 606.2.1. ALSO, DUCT DETECTOR(S) SHALL BE
 CONNECTED TO THE BUILDING FIRE ALARM SYSTEM IN
 ACCORDANCE WITH FBC,M 606.4.1. CONSULT LANDLORD
 REGARDING CONNECTION TO EXISTING FIRE ALARM SYSTEM.
  
 6. MP1.1: TOILET ROOM EXHAUST FANS SHALL BE
 INTERCONNECTED WITH AH-1 TO ENSURE ALL AIR SUPPLIED TO
 THESE SPACES IS EXHAUSTED IN ACCORDANCE WITH FBC,M
 403.2.1(3). PROVISIONS SHALL ALSO BE MADE TO ENSURE
 THAT VENTILATION IS PROVIDED WHENEVER THESE SPACES ARE
 OCCUPIED IN ACCORDANCE WITH FBC,M 401.3.
  
 7. MP1.1: PROVIDE AIR BALANCE SCHEDULE SHOWING SUPPLY,
 RETURN AND EXHAUST TOTALS. THE SPACE SHALL BE
 PRESSURIZED WITH RESPECT TO THE OUTDOORS IN ACCORDANCE
 WITH FBC 13-409.1.ABC.2.
  
 8. MP1.1: PROVIDE SHUTOFF DAMPER CONTROLS FOR OUTSIDE
 AIR INTAKE DUCT IN ACCORDANCE WITH FBC
 13-409.1.ABC.3.3.
  
 9. MP1.1: CONDENSATE IS SHOWN DISCHARGING INTO A MOP
 SINK. CONDENSATE DRAINS SHALL DISCHARGE TO AN APPROVED
 PLACE OF DISPOSAL IN ACCORDANCE WITH FBC,M 307.2.1. A/C
 CONDENSATE SHALL NOT DISCHARGE INTO THE SANITARY SEWER
 SYSTEM IN ACCORDANCE WITH WPB MUNICIPAL CODE SECTION
 90-125(5).
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-12-03 Cont ID  
Sent By kstevens Date 2007-12-03 Time 18:26 Rev Time 0.00
Received By kstevens Date 2007-12-03 Time 18:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-11-06 Cont ID  
Sent By kstevens Date 2007-11-06 Time 10:22 Rev Time 0.00
Received By kstevens Date 2007-11-06 Time 10:22 Sent To  
Notes
2007-11-06 10:26:43DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 CITY WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 ****FROM PREVIOUS REVIEW:
  
 1. OK
  
 2. ALL ARCHITECTURAL TITLE BLOCKS. THE FIRM LICENSE
 NUMBER, (CERTIFICATE OF AUTHORIZATION),IS REQUIRED IN
 THE TITLE BLOCK ON ALL SHEETS WITH THE TITLE BLOCK ON
 IT. FAC 61G1-16.004(2) & FS 481.219, 481.2055. PLEASE
 INDICATE FIRM LICENSE NUMBER IN TITLE BLOCKS.
 ****RESPONSE NOTED, BUT THE LICENSE NUMBER FOR THE
 ARCHITECT IS NOW REQUIRED IN THE TITLE BLOCK OF EACH
 SHEET AS THE ARCHITECTURAL FIRM IS ROBERT ROSENTHAL
 ARCHITECT.
  
 3. ALL SHEETS SIGNED BY THE ARCHITECT. THE SIGNATURE OF
 THE ARCHITECT SHALL BE AFFIXED ON THE SEAL. IT APPEARS
 THAT INITIALS HAVE BEEN USED. IF THIS IS INDEED THE
 LEGAL SIGNATURE OF THE ARCHITECT, THEN A SIGNED,
 SEALED, NOTORIZED LETTER INDICATING THE LEGAL SIGNATURE
 OF THE ARCHITECT SHALL BE SUBMITTED FOR OUR FILES. FAC
 61G1-16.003, 61G1-16.004(6) & FS 481.2055.
 ****RESPONSE NOTED, BUT THE LETTER HAS NOT BEEN SIGNED
 & SEALED.PLEASE PROVIDE A SIGNED, SEALED, NOTORIZED
 LETTER.
  
 4. OK
 5. OK
  
 6. SHT MP1.1 PLUMBING SPECIFICATIONS. CONDENSATE DRAIN
 CALLS FOR A/C CONDENSATETO BE DRAINED TO A FLOOR SINK,
 MOP SINK ETC. THIS IS NOT APPROVED. PLEASE CORRECT
 REFERENCE. (SEE COMMENT #5).
 ****RESPONSE NOTED, BUT THE NOTE HAS NOT CHANGED.
 PLEASE CHANGE NOTE TO CORRELATE WITH FLOOR PLAN.
  
 7. OK
 8. OK
 9. OK
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID
 SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY
 ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-10-04 Cont ID  
Sent By kstevens Date 2007-10-04 Time 07:02 Rev Time 0.00
Received By kstevens Date 2007-10-03 Time 06:32 Sent To  
Notes
2007-10-04 07:29:18DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 CITY WPB MUNICIPAL CODE
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. SEE ELECTRICAL COMMENT #1 CONCERNING THE SUITE
 NUMBER & TITLE BLOCKS. SECTIONS 106.1.2, 110.1.2(2), &
 FAC 61G1-16.004, 61G15-23.002.
  
 2. ALL ARCHITECTURAL TITLE BLOCKS. THE FIRM LICENSE
 NUMBER, (CERTIFICATE OF AUTHORIZATION),IS REQUIRED IN
 THE TITLE BLOCK ON ALL SHEETS WITH THE TITLE BLOCK ON
 IT. FAC 61G1-16.004(2) & FS 481.219, 481.2055. PLEASE
 INDICATE FIRM LICENSE NUMBER IN TITLE BLOCKS.
  
 3. ALL SHEETS SIGNED BY THE ARCHITECT. THE SIGNATURE OF
 THE ARCHITECT SHALL BE AFFIXED ON THE SEAL. IT APPEARS
 THAT INITIALS HAVE BEEN USED. IF THIS IS INDEED THE
 LEGAL SIGNATURE OF THE ARCHITECT, THEN A SIGNED,
 SEALED, NOTORIZED LETTER INDICATING THE LEGAL SIGNATURE
 OF THE ARCHITECT SHALL BE SUBMITTED FOR OUR FILES. FAC
 61G1-16.003, 61G1-16.004(6) & FS 481.2055.
  
 4. SEE ELECTRICAL COMMENT #3 CONCERNING THE ENGINEER OF
 RECORD INFORMATION ON SHT TS. PLEASE RESPOND.
  
 5. SHT MP1.1 CONDENSATE FROM AH1 SHALL NOT DRAIN INTO
 THE SANITARY SYSTEM. ARTICLE III SECTION 90-125(5).
 DRAINING INTO THE MOP SINK IS NOT APPROVED. THE
 CONDENSATE SHALL DRAIN SEPARATELY FROM THE BUILDING BY
 CONNECTING TO A DEDICATED CONDENSATE SYSTEM, CONNECTING
 TO A STORM LINE, CATCH BASIN, DRYWELL, OR PLANTED AREA
 OUTSIDE THE BUILDING. IF CONNECTING TO A STORM LINE
 OUTSIDE THE BUILDING A RELEIF VENT, (GOOSENECK), SHALL
 BE INSTALLED AS THE CONDENSATE EXITS THE BUILDING.
  
 6. SHT MP1.1 PLUMBING SPECIFICATIONS. CONDENSATE DRAIN
 CALLS FOR A/C CONDENSATETO BE DRAINED TO A FLOOR SINK,
 MOP SINK ETC. THIS IS NOT APPROVED. PLEASE CORRECT
 REFERENCE. (SEE COMMENT #5).
  
 7. SHT A1.1 INDICATES THE RELOCATION OF THE DRINKING
 FOUNTAIN. THIS IS NOT SHOWN ON SHT MP1.1. PLEASE SHOW
 THE NEW LOCATION OF THE DRINKING FOUNTAIN AND SUBMIT A
 SANITARY ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE
 SIZES, VENTS, TRAPS ECT. ALSO SUBMIT A WATER ISOMETRIC
 RISER DIAGRAM SHOWING ALL PIPE SIZES, VALVES, ETC.
 SECTION 106.3.5.1.3(3)(4)(6)(10)(13).
  
 8. SUBMIT A DETAIL AND ELEVATION SHOWING COMPLIANCE
 WITH SECTION 11-4.15 AND ALL SUBSECTIONS. ALSO SHOW
 COMPLIANCE WITH SECTION 11-4.1.3(10)(A) REQUIREMENTS
 FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING.
  
 9. PER SECTION 607.1 HOT WATER IS REQUIRED FOR BUILDING
 MAINTENANCE. HOT WATER IS REQUIRED TO THE MOP SINK.
 PLEASE SHOW COMPLIANCE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID
 SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY
 ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2007-12-03 Cont ID  
Sent By eschneid Date 2007-12-03 Time 18:43 Rev Time 0.00
Received By eschneid Date 2007-12-03 Time 18:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-11-08 Cont ID  
Sent By eschneid Date 2007-11-08 Time 18:41 Rev Time 0.00
Received By eschneid Date 2007-11-08 Time 18:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2007-10-05 Cont ID  
Sent By lmartine Date 2007-10-05 Time 17:38 Rev Time 0.00
Received By lmartine Date 2007-10-05 Time 17:38 Sent To  
Notes
2007-10-05 17:40:12SIGNAGE WILL REQUIRE SEPARATE PERMIT.PER ERIC
 SCHNEIDER