Plan Review Details - Permit 07090828
Plan Review Stops For Permit 07090828
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-01-10 Cont ID  
Sent By amorse Date 2008-01-10 Time 18:48 Rev Time 0.00
Received By amorse Date 2008-01-10 Time 18:48 Sent To PC
Notes
2008-01-10 18:52:56 
 PASSED
  
 PLEASE NOTE THAT FEES FOR RADON IN THE AMOUNT OF $3.44
 ARE OUTSTANDING AND MUST BE PAID BEFORE A PERMIT IS
 ISSUED, ALSO A NOTICE OF COMMENCEMENT IS REQUIRED.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-30 Cont ID  
Sent By amorse Date 2007-10-30 Time 14:34 Rev Time 0.00
Received By amorse Date 2007-10-30 Time 14:34 Sent To PC
Notes
2007-10-30 14:37:11 
  
 DENIED
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*
  
 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE
 DRAWINGS
  
 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $ 3.44 FOR STATE
 RADON FEES THIS AMOUNT IS REQUIRED TO BE PAID PRIOR TO
 FURTHER PLAN REVIEW
  
 4) SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 5)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG ******NOTE
 THAT ONLY ONE COPY OF PRODUCT APPROVAL WAS SUBMITTED
 FOR DOORS, WINDOWS AND SEVERAL OF THE SIMPSON TIE
 CONNECTORS******
  
 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
 ******NOTE THE DOOR AND WINDOW PRODUCT APPROVALS WERE
 NOT REVIEWED AND APPROVED******
  
 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE.
 THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.
 WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
 ******NOTE THE DOOR AND WINDOW PRODUCT APPROVALS DO NOT
 CONTAIN THE STATE APPROVAL SHEETS, PLEASE SEE THAT THE
 CORRECT FL# IS WRITTEN AT THE TOP OF THE NOA******
  
 8)PRODUCT APPROVALS THAT WERE SUBMITTED FOR LINTELS
 ARE FROM THE 2001 CODE CYCLE AND THE MIAMI-DADE
 EVALUATION REPORT(NOA) HAS EXPIRED. ALSO THE SHINGLES,
 USING THE STATE APPROVAL ARE VALIDATED BY UL AND ARE
 APPROVED ONLY TO 110 MPH. IF THESE SHINGLES ARE TO BE
 USED PROVIDE 2 COPIES OF THE UPDATED MIAMI-DADE REPORT
 FOR USE AS A LOCALLY APPROVED PRODUCT. PLEASE NOTE THAT
 MIAMI-DADE THAT WAS SUBMITTED HAS EXPIRED.
  
 THE FOLLOWING COMMENTS PERTAIN TO THE TRUSS
 ENGINEERING:
  
 9)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF THE FLORIDA
 STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND
 DATE TO SAID DRAWINGS AND SPECIFICATIONS PER 106.1 FBC
 2004.
  
 10)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME,
 ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS
 THEIR SEAL PER
 61G15-23.002(2) FAC
  
 ******PLEASE NOTE THAT THE GENERIC NOTES AND DRAWINGS
 WILL BE ACCEPTABLE IF TWO COPIES OF AN INDEX SHEET THAT
 MEETS THE REQUIREMENTS OF NOTES 9 & 10 ARE MET******
  
 11)REMOVE ALL EXPIRED AND INVALID PRODUCT APPROVALS
 FROM FURTHER RESUBMITTALS AND REMOVE ALL OLD PAGES AND
 RESUBMIT 2 COMPLETE SETS OF NEW DRAWINGS AND INCLUDE 1
 COPY OF THE OLD PAGES ONLY FOR REFERENCE
  
 12)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-01-02 Cont ID  
Sent By btrobaug Date 2008-01-02 Time 07:32 Rev Time 0.00
Received By btrobaug Date 2008-01-02 Time 06:52 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-10-05 Cont ID  
Sent By btrobaug Date 2007-10-05 Time 15:50 Rev Time 0.00
Received By btrobaug Date 2007-10-05 Time 15:14 Sent To M
Notes
2007-10-05 16:11:29 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
 ALL COMMENTS RELATE TO SHEET 3/3, UNLESS OTHERWISE
 NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS
 OTHERWISE NOTED.
  
 1} THERE IS A SMALL APPLIANCE CIRCUIT ADDED TO THE
 PANEL SCHEDULE, BUT NO WORK SHOWN IN AREAS THIS WOULD
 SERVE, PLEASE CLARIFY.
  
 2} THERE ARE REFERENCES IN THE ELECRICAL NOTES TO BOTH
 10000 AND 22000K AIC RATINGS. SPECIFY THE CORRECCT ONE
 TO BE USED PER 110.9 AND 110.10.
  
 3} THE 2005 NEC WAS ADOPTED BY THE FLORIDA LEGISLATURE
 EFFECTIVE 8 DECEMBER 2006. THE APPLICATION FOR THIS
 PROJECT WAS AFTER THAT DATE AND THE PLANS ARE SUBJECT
 TO THAT CODE. PLEASE CHANGE ALL NOTES TO REFLECT THIS
 CHANGE. THERE ARE REFERENCES TO THE 1996 AND 2002 NEC
 ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
 FAX/:561/805-6676

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-04-04 Cont ID  
Sent By choops Date 2008-04-04 Time 10:02 Rev Time 0.00
Received By choops Date 2008-04-04 Time 10:02 Sent To Z
Notes
2008-04-04 10:07:49REV. SENT TO Z

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-01-25 Cont ID  
Sent By shill Date 2008-01-25 Time 11:02 Rev Time 0.00
Received By shill Date 2008-01-25 Time 11:02 Sent To M
Notes
2008-01-25 11:02:59TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-12-27 Cont ID  
Sent By spalmer Date 2007-12-27 Time 15:55 Rev Time 0.00
Received By spalmer Date 2007-12-27 Time 15:55 Sent To Z
Notes
2007-12-27 15:56:12TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-10-30 Time   Rev Time 0.00
Received By adarroug Date 2007-10-02 Time 09:29 Sent To  
Notes
2007-10-02 09:30:31TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-01-25 Cont ID  
Sent By tgordon Date 2008-01-25 Time 14:01 Rev Time 0.45
Received By tgordon Date 2008-01-25 Time 14:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-01-02 Cont ID  
Sent By tgordon Date 2008-01-02 Time 08:29 Rev Time 0.40
Received By tgordon Date 2008-01-02 Time 08:29 Sent To B
Notes
2008-01-02 08:50:38PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS LINE 9 A-1 IS CALLING FOR R4.1
 WALL INSULATION, TABLE 6C-1 ON BACK OF ENERGY
 CALCULATIONS STATES THE MINIMUM INSULATION FOR BLOCK
 WALLS IS R-5, YOU MAY NOT PICK AND CHOSE. SEE 2004 FBC
 13-602.1.A.1, PLEASE CORRECT.
  
 2) ENERGY CALCULATIONS LINE 10A IS CALLING FOR R-19
 ATTIC INSULATION, TABLE 6C-1 ON BACK OF ENERGY
 CALCULATIONS STATES THE MINIMUM INSULATION FOR ATTICS
 IS R-30, YOU MAY NOT PICK AND CHOSE. SEE 2004 FBC
 13-604.1.C.1, PLEASE CORRECT.
  
 3) COOLING LOAD CALCULATIONS ARE CALLING FOR 43,978
 TOTAL COOLING BTU'S, MECHANICAL PLAN PAGE 3/3 IS
 SHOWING 58,200 TOTAL COOLING BTU'S, THE PLANS CAN ONLY
 CALL FOR 15% MORE THAN THE COOLING LOAD CALCULATIONS (A
 5 TO SYSTEM IS TO LARGE) SEE 2004 FBC 13-607.1.ABC.1.1,
 PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-10-16 Cont ID  
Sent By tgordon Date 2007-10-16 Time 10:24 Rev Time 0.30
Received By tgordon Date 2007-10-16 Time 10:24 Sent To P
Notes
2007-10-16 10:33:03PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600C-04R, SEE
 2004 FBC 13-600.3.C.
  
 2) COOLING LOAD CALCULATIONS ARE SHOWING THE UNDER AIR
 AREA AS 1,916 SQUARE FEET, PLANS SHOW THE UNDER AIR
 SQUARE FEET AS 1,701,PLEASE CORRECT COOLING LOAD
 CAL'S.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-10-24 Cont ID  
Sent By jleech Date 2007-10-24 Time 07:14 Rev Time 0.00
Received By jleech Date 2007-10-24 Time 07:14 Sent To B
Notes
2007-10-24 07:15:14NO PLUMBING SHOWN ON DRAWINGS

Review Stop Z ZONING
Rev No 3 Status P Date 2008-04-04 Cont ID  
Sent By choops Date 2008-04-04 Time 10:12 Rev Time 0.00
Received By choops Date 2008-04-04 Time 10:12 Sent To PC
Notes
2008-04-04 10:13:32***APPROVED - REVISION - ADDING CONCRETE WALKWAYS AT
 SIDE AND REAR OF HOME***
  
 PROVISO:WALKWAYS MUST BE SETBACK A MINIMUM OF 6
 INCHES FROM SIDE PROPERTY LINE TO ALLOW FOR ADEQUATE
 DRAINAGE.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-12-28 Cont ID  
Sent By choops Date 2007-12-28 Time 10:34 Rev Time 0.00
Received By choops Date 2007-12-28 Time 10:34 Sent To E
Notes
2007-12-28 10:35:42***APPROVED - RESUB #1 - RESTAMPED PLANS***
  
 PROVISO:A/C UNIT SHALL NOT BE CLOSER THAN 1' TO WEST
 SIDE PROPERTY LINE AND NOT CLOSER THAN 6.7' TO THE REAR
 PROPERTY LINE.
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status P Date 2007-10-03 Cont ID  
Sent By choops Date 2007-10-03 Time 09:46 Rev Time 0.00
Received By choops Date 2007-10-03 Time 09:46 Sent To E
Notes
2007-10-03 09:47:00PROVISO:A/C UNIT SHALL NOT BE CLOSER THAN 1' TO WEST
 SIDE PROPERTY LINE AND NOT CLOSER THAN 6.7' TO THE REAR
 PROPERTY LINE.