Plan Review Details - Permit 07090768
Plan Review Stops For Permit 07090768
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-01-03 Cont ID  
Sent By rmcdouga Date 2008-01-03 Time 07:45 Rev Time 0.00
Received By rmcdouga Date 2008-01-03 Time 07:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-12-11 Cont ID  
Sent By rmcdouga Date 2007-12-11 Time 10:15 Rev Time 0.00
Received By rmcdouga Date 2007-12-11 Time 10:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-24 Cont ID  
Sent By rmcdouga Date 2007-10-24 Time 14:04 Rev Time 0.00
Received By rmcdouga Date 2007-10-24 Time 07:15 Sent To  
Notes
2007-10-24 16:42:112004 FBC W/2007 REVISIONS
 LEVEL 2 ADDITION
  
 DENIED BY BUILDING
  
 1)SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY
 IMPACT FEES.
  
 2) SHOW COMPLIANCE WITH R302.1, WHICH REQUIRES EXTERIOR
 WALLS TO BE SEPARATED BY 6 FEET OR HAVE WALLS THAT ARE
 ONE HOUR FIRE RATED WITH NO OPENINGS. THE SURVEY SHOWS
 5.1' TO THE PROPERTY LINE ON ONE SIDE OF THE ADDITION.
 PROVIDE A SITE PLAN THAT SPECIFIES THAT THE DISTANCE TO
 ANY STRUCTURES ON THE ADJACENT LOT IS 6 FEET OR MORE.
  
 3) THE EXISTING BEDROOM THAT IS HAVING THE WINDOW
 ENCLOSED FOR THE ADDITION IS REQUIRED TO MAINTAIN THE
 EXISTING LEVEL OF EMERGENCY EGRESS. FBC R 310 AND
 EXISTING BUILDING 901.2.
  
 4)THE ATTIC ACCESS REQUIRED BY R 807.1, IS SHOWN ON
 SHEET A-4 AND THE MECHANICAL PLANS IN THE WRONG
 ORIENTATION IN REGARD TO THE ROOF TRUSSES. PLEASE
 CORRECT.
  
 5) SHOW COMPLIANCE WITH R 320.1. SPECIFY THE TERMITE
 TREATMENT THAT WILL BE USED ON THE PLANS.
  
 6) SHOW COMPLIANCE WITH R 408.1 AND R 408.3 FOR CRAWL
 SPACE VENTILATION AND ACCESS TO UNDER-FLOOR SPACE.
  
 7) THE OVERHANG AT THE EAVES IS NOT SPECIFIED ON
 SECTION A ON A-3 BUT APPEARS TO BE LESS THAN 6 INCHES.
 SHOW COMPLIANCE WITH R320.7, WHICH REQUIRES GUTTERS
 WITH DOWNSPOUTS THAT DISCHARGE AT LEAST ONE FOOT AWAY
 FROM THE STRUCTURE SIDEWALL.
  
 8)SPECIFY ON THE PLANS HOW FBC R806.1 ROOF
 VENTILATION IS BEING COMPLIED WITH.
  
 9) THE MASONRY AND STEEL NOTES ON A-2 REFERENCE OLDER
 EDITIONS OF ACI 530, TMS 402 AND ASCE 5. PLEASE UPDATE
 TO THE EDITIONS THAT ARE REFERENCED IN CHAPTER 24 OF
 THE 2004 FBC RESIDENTIAL CODE, WHICH ARE ACI 530-05,
 TMS 402-02 AND ASCE5-02.
  
 10) ON SECTION A 0N SHEET A-3 THE MINIMUM EMBED DEPTH
 FOR THE 10" WEDGE ANCHORS USED TO ATTACH THE WALL
 LEDGER FOR THE FLOOR SYSTEM IS PRINTED OVER AND
 ILLEGIBLE. PLEASE CORRECT.
  
 11) SPECIFY THE REQUIRED TRUSS DESIGN LOADS ON THE
 PLANS. SEE R802.1.6.1.
  
 12) THE TRUSS LAYOUT DRAWING IS REQUIRED TO BE SIGNED,
 SEALED AND DATED BY THE TRUSS ENGINEER. SEE R 802.1.6.2
 AND FS 471.
  
 13) THE TRUSS LAYOUT DRAWING SHOULD BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 CONFORMANCE TO THE STRUCTURES DESIGN.
  
 14) THE MINIMUM LIVE LOAD REQUIRED FOR THE ROOF TRUSS
 BOTTOM CORD IS 10 PSF PER TABLE R 301.5. PLEASE CORRECT
 TRUSS DRAWING AND LAYOUT DESIGN DATA.
  
 15) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATIONS PER FBC CHAPTER 13.
  
 16) THE MINIMUM INSULATION REQUIRED ON CONCRETE BLOCK
 WALLS BY THE PRESCRIPTIVE REQUIREMENTS OF ENERGY CALC.
 FORM 600C-04R IS R-5. ON SECTION A ON A-3, R4-2
 INSULATION IS SPECIFIED ON SECTION A ON A-3.
  
 17) THE GEOTECHNICAL SOIL REPORT FROM THE ENGINEER IS
 REQUIRED TO BE SIGNED, SEALED AND DATED. FS 471
  
 18) FBC 106.3* CITY AMENDMENTS PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 19) THE NOA FOR THE STORM PANELS HAS BEEN REVISED BY
 NOA NO. 05-0926.02 AND THE WRONG STATE COVERSHEET WAS
 SUBMITTED. THE CORRECT ONE IS FL # 7226. PLEASE
 CORRECT.
  
 20) PLEASE SUBMIT AN INSTALLATION SCHEDULE INDICATING
 THE TYPE OF MOUNT, ANCHOR TYPE, ANCHOR SPACING, EDGE
 DISTANCE, GLASS SEPARATION, SPANS, ETC. THE APPROPRIATE
 INFORMATION CAN BE CIRCLED ON THE PRODUCT APPROVAL. FBC
 106.1.2
  
 21) THE WRONG COVERSHEET WAS SUBMITTED FOR THE RIDGE
 VENT. FL# 243 IS THE ONE THAT CORRESPONDS WITH NOA NO
 07-0125.01
  
 22) PLEASE DO NOT STAPLE THE PRODUCT APPROVALS TO THE
 PLANS. SUBMITTING A RESPONSE LETTER STATINGHOW THE
 COMMENTS WERE ADDRESSED WILL HELP CUT DOWN PLAN REVIEW
 TIME. THANKS.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-12-26 Cont ID  
Sent By btrobaug Date 2007-12-26 Time 09:27 Rev Time 0.00
Received By btrobaug Date 2007-12-26 Time 07:56 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-11-16 Cont ID  
Sent By btrobaug Date 2007-11-16 Time 08:41 Rev Time 0.00
Received By btrobaug Date 2007-11-16 Time 06:41 Sent To M
Notes
2007-11-16 08:41:34 
  
  
 APPLICATION #07090768
 ELECTRICAL PLAN REVIEW
 416 55TH STREET
 11/16/07
 WEST PALM BEACH, FL.
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
 ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE
 NOTED.
  
 1} THE DISCONNECT SHOWN ON THE RISER(S) DOES NOT
 INDICATE A RATING. LABEL THE DISCONNECT WITH THE
 AMPERAGE RATING INTENDED. 215.5
  
 2} PROVIDE THE AIC RATING FOR THE SERVICE EQUIPMENT
 PER110.9-110.10.
  
 3} CIRCUIT #6 IN THE ?NEW? PANEL MUST BE ARC FAULT
 PROTECTED PER 210.12. INDICATE THE SAME ON THE
 SCHEDULE. THE NUMBERING/NOTE SYSTEM IS SUFFICIENT.
  
 4} NOTE #4 IN THE ?GENERAL ELECTRICAL NOTES? SHOULD
 INCLUDE A REFERENCE TO 250.52(A)(3), FOOTER STEEL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-10-02 Cont ID  
Sent By btrobaug Date 2007-10-02 Time 13:30 Rev Time 0.00
Received By btrobaug Date 2007-10-02 Time 12:52 Sent To M
Notes
2007-10-02 13:25:25 
  
 APPLICATION #07090768
 ELECTRICAL PLAN REVIEW
 416 55TH STREET
  
 WEST PALM BEACH, FL.
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN
 IS NEW OR EXISTING. IF NEW INCLUDE, AN AIC RATING.
  
 2} LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, METER
 ENCLOSURE, DISCONNECTS AND PANELS, SO THAT COMPLIANCE
 WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 3} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III,
 STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. SEE
 220.83(B) SINCE A/C IS BEING ADDED.
  
 4} SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER
 440.14, RECEPTACLE PER 210.63, LIGHT PER
 210.70(A) (3), FOR THE AHU IN THE ATTIC.
  
 5} THE GROUNDING ELECTRODE CONDUCTOR MUST COMPLY WITH
 250.66, #2 FOR 4/0 SERVICE CONDUCTORS.
  
 6} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417
 FS, RESPECTIVELY. THE CONTRACTOR OF RECORD MAY BE THE
 DESIGN PROFESSIONAL IF EXEMPTIONS UNDER CHAPTER
 471.003, FLORIDA STATUTES, IF EXEMPTIONS APPLY.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-01-07 Cont ID  
Sent By shill Date 2008-01-07 Time 15:40 Rev Time 0.00
Received By shill Date 2008-01-07 Time 15:40 Sent To Z
Notes
2008-01-07 15:40:57TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-20 Cont ID  
Sent By mmiller Date 2007-12-20 Time 17:28 Rev Time 0.00
Received By mmiller Date 2007-12-20 Time 17:28 Sent To  
Notes
2007-12-20 17:28:25SENT TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-08 Cont ID  
Sent By adarroug Date 2007-11-08 Time 15:31 Rev Time 0.00
Received By adarroug Date 2007-11-08 Time 15:31 Sent To Z
Notes
2007-11-08 15:31:33TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-24 Cont ID  
Sent By rmcdouga Date 2007-10-24 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2007-09-28 Time 08:26 Sent To  
Notes
2007-09-28 08:28:23TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-12-26 Cont ID  
Sent By tgordon Date 2007-12-26 Time 09:54 Rev Time 0.25
Received By tgordon Date 2007-12-26 Time 09:54 Sent To P
Notes
2007-12-26 09:55:45REVIEWED AND STAMPED ON 11-16-07.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-11-16 Cont ID  
Sent By tgordon Date 2007-11-16 Time 09:17 Rev Time 0.20
Received By tgordon Date 2007-11-16 Time 09:17 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-10-15 Cont ID  
Sent By tgordon Date 2007-10-15 Time 08:26 Rev Time 0.25
Received By tgordon Date 2007-10-15 Time 08:26 Sent To P
Notes
2007-10-15 08:27:37PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-12-31 Cont ID  
Sent By jleech Date 2007-12-31 Time 09:02 Rev Time 0.00
Received By jleech Date 2007-12-31 Time 08:56 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-12-05 Cont ID  
Sent By jleech Date 2007-12-05 Time 14:53 Rev Time 0.00
Received By jleech Date 2007-12-05 Time 14:48 Sent To B
Notes
2007-12-05 15:02:07DENIED;
 1. SANITARY RISER DIAGRAM DOES NOT MATCH FLOOR PLAN .
 FLOOR PLAN SHOWS 1 LAVATORY AND A TUB. SANITARY RISER
 DIAGRAM SHOW 2-LAVATORYS AND A SHOWER.
 2. TRAP SIZES ARE NOT CORRECT. SEE FBC PLUMBINGTABLE
 709.1. BATHTUB TRAP TO BE 1 1/2" AND THE AUTOMATIC
 CLOTHES WASHER TRAP TO BE 2".
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-10-22 Cont ID  
Sent By jleech Date 2007-10-22 Time 09:46 Rev Time 0.00
Received By jleech Date 2007-10-22 Time 09:46 Sent To B
Notes
2007-10-22 10:00:31DENIED;
 1. THE PERSON TAKING RESPONSIBITY FOR THE DRAWING MUST
 SIGNEACH PAGE.
 2. SEE PLUMBING RISER DIAGRAM PAGE A-4;
 A) AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO
 BE 3" SEE FBC PLUMBING SECTION 406.3.
 B) THE L-SINK SHALL DISCHARGE ABOVE THE W/M
 BRANCH. SECTION 706.3
 3. THE ADDRESS OF JOB SHOULD BE ON EACH PAGE OF THE
 PLANS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 4 Status P Date 2008-01-09 Cont ID  
Sent By choops Date 2008-01-09 Time 08:52 Rev Time 0.00
Received By choops Date 2008-01-09 Time 08:52 Sent To PC
Notes
2008-01-09 08:52:56***APPROVED - RESUB #3***
  
  

Review Stop Z ZONING
Rev No 3 Status F Date 2007-12-24 Cont ID  
Sent By choops Date 2007-12-24 Time 13:54 Rev Time 0.00
Received By choops Date 2007-12-24 Time 13:54 Sent To E
Notes
2007-12-24 14:03:44***FAILED - RESUB #2***
  
  
 REPEAT COMMENTS:
  
 1)THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE
 VALUE OF THE HOME.PURSUANT TO ARTICLE XIV OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), A
 LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION 94-442
 OF THE ZLDR'S SHALL BE SUBMITTED.THE PLAN SUBMITTED
 IS INSUFFICIENT.MUST MEET MINIMUM REQUIREMENTS FOUND
 IN SECTION 94-442 AND 94-445 OF THE ZLDRS.FOR
 SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHADE,
 FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200
 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. FOR
 SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHRUB SHALL
 BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN SPACE OR
 PORTION THEREOF.NOTE: PALM TREES DO NOT COUNT AS
 SHADE/FLOWERING TREES.ALL TREES AND SHRUBS MUST MEET
 MINIMUM HEIGHT REQUIREMENTS FOUND IN SECTION 94-442.
 MY CALCULATIONS SHOW AN OPEN SPACE OF APPROX. 2550
 SQ.FT. WHICH WOULD REQUIRE THREE (3) TREES, THE
 SUBMITTED LANDSCAPE PLAN SHOWS ONLY ONE (1) TREE WITHIN
 THE PROPERTY LINES.
  
 2)THE A/C UNIT LOCATION IS INCONSISTENT BETWEEN
 PLANS.ALL PLANS TO BE CONSISTENT AND SHALL INDICATE
 SETBACK DIMENSIONS FROM PROPOSED A/C EQUIPMENT TO THE
 PROPERTY LINES.AS PER SECTION 94-305(B)(4) OF THE
 ZLDRS: MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN
 4' INTO A REQUIRED SETBACK.
  
 PLEASE DO NOT HESITATE TO CALL WITH QUESTIONS.
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2007-11-14 Cont ID  
Sent By choops Date 2007-11-14 Time 12:53 Rev Time 0.00
Received By choops Date 2007-11-14 Time 12:53 Sent To E
Notes
2007-11-14 12:53:00***FAILED - RESUB #1***
  
  
 REPEAT COMMENTS:
  
 1)THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE
 VALUE OF THE HOME.PURSUANT TO ARTICLE XIV OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS(ZLDRS), A
 LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION 94-442
 OF THE ZLDR'S SHALL BE SUBMITTED.PLAN SUBMITTED IS
 INSUFFICIENT.MUST MEET MINIMUM REQUIREMENTS FOUND IN
 AFOREMENTIONED SECTION.FOR SINGLE-FAMILY DWELLING
 UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT TREE
 SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN
 SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY DWELLING
 UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500
 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.NOTE:
 PALM TREES DO NOT COUNT AS SHADE/FLOWERING TREES.ALL
 TREES AND SHRUBS MUST MEET MINIMUM HEIGHT REQUIREMENTS
 FOUND IN SECTION 94-442.
  
 2)INDICATE LEGIBLE HEIGHT DIMENSIONS OF THE PROPOSED
 ADDITION FROM GRADE TO THE MIDPOINT OF THE ROOFS PITCH.
 (DIMENSION IS CUTOFF ON PLANS)
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-09-28 Cont ID  
Sent By choops Date 2007-09-28 Time 14:01 Rev Time 0.00
Received By choops Date 2007-09-28 Time 14:01 Sent To E
Notes
2007-09-28 14:04:42***FAILED***
  
  
 1)VALUE OF PROPOSED WORK EXCEEDS 50% OF THE VALUE OF
 THE HOME.PURSUANT TO ARTICLE XIV OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS(ZLDRS), A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTION 94-442 OF THE ZLDR'S
 SHALL BE SUBMITTED.
  
 2)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED A/C
 EQUIPMENT TO THE PROPERTY LINES.
  
 3)INDICATE LEGIBLE HEIGHT DIMENSIONS OF THE
 PROPOSED.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720