| Plan Review Stops For Permit 07090768 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-01-03 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-01-03 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-12-11 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-12-11 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-24 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-10-24 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2007-10-24 16:42:11 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1)SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY | | | IMPACT FEES. | | | | | | 2) SHOW COMPLIANCE WITH R302.1, WHICH REQUIRES EXTERIOR | | | WALLS TO BE SEPARATED BY 6 FEET OR HAVE WALLS THAT ARE | | | ONE HOUR FIRE RATED WITH NO OPENINGS. THE SURVEY SHOWS | | | 5.1' TO THE PROPERTY LINE ON ONE SIDE OF THE ADDITION. | | | PROVIDE A SITE PLAN THAT SPECIFIES THAT THE DISTANCE TO | | | ANY STRUCTURES ON THE ADJACENT LOT IS 6 FEET OR MORE. | | | | | | 3) THE EXISTING BEDROOM THAT IS HAVING THE WINDOW | | | ENCLOSED FOR THE ADDITION IS REQUIRED TO MAINTAIN THE | | | EXISTING LEVEL OF EMERGENCY EGRESS. FBC R 310 AND | | | EXISTING BUILDING 901.2. | | | | | | 4)THE ATTIC ACCESS REQUIRED BY R 807.1, IS SHOWN ON | | | SHEET A-4 AND THE MECHANICAL PLANS IN THE WRONG | | | ORIENTATION IN REGARD TO THE ROOF TRUSSES. PLEASE | | | CORRECT. | | | | | | 5) SHOW COMPLIANCE WITH R 320.1. SPECIFY THE TERMITE | | | TREATMENT THAT WILL BE USED ON THE PLANS. | | | | | | 6) SHOW COMPLIANCE WITH R 408.1 AND R 408.3 FOR CRAWL | | | SPACE VENTILATION AND ACCESS TO UNDER-FLOOR SPACE. | | | | | | 7) THE OVERHANG AT THE EAVES IS NOT SPECIFIED ON | | | SECTION A ON A-3 BUT APPEARS TO BE LESS THAN 6 INCHES. | | | SHOW COMPLIANCE WITH R320.7, WHICH REQUIRES GUTTERS | | | WITH DOWNSPOUTS THAT DISCHARGE AT LEAST ONE FOOT AWAY | | | FROM THE STRUCTURE SIDEWALL. | | | | | | 8)SPECIFY ON THE PLANS HOW FBC R806.1 ROOF | | | VENTILATION IS BEING COMPLIED WITH. | | | | | | 9) THE MASONRY AND STEEL NOTES ON A-2 REFERENCE OLDER | | | EDITIONS OF ACI 530, TMS 402 AND ASCE 5. PLEASE UPDATE | | | TO THE EDITIONS THAT ARE REFERENCED IN CHAPTER 24 OF | | | THE 2004 FBC RESIDENTIAL CODE, WHICH ARE ACI 530-05, | | | TMS 402-02 AND ASCE5-02. | | | | | | 10) ON SECTION A 0N SHEET A-3 THE MINIMUM EMBED DEPTH | | | FOR THE 10" WEDGE ANCHORS USED TO ATTACH THE WALL | | | LEDGER FOR THE FLOOR SYSTEM IS PRINTED OVER AND | | | ILLEGIBLE. PLEASE CORRECT. | | | | | | 11) SPECIFY THE REQUIRED TRUSS DESIGN LOADS ON THE | | | PLANS. SEE R802.1.6.1. | | | | | | 12) THE TRUSS LAYOUT DRAWING IS REQUIRED TO BE SIGNED, | | | SEALED AND DATED BY THE TRUSS ENGINEER. SEE R 802.1.6.2 | | | AND FS 471. | | | | | | 13) THE TRUSS LAYOUT DRAWING SHOULD BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | CONFORMANCE TO THE STRUCTURES DESIGN. | | | | | | 14) THE MINIMUM LIVE LOAD REQUIRED FOR THE ROOF TRUSS | | | BOTTOM CORD IS 10 PSF PER TABLE R 301.5. PLEASE CORRECT | | | TRUSS DRAWING AND LAYOUT DESIGN DATA. | | | | | | 15) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | CALCULATIONS PER FBC CHAPTER 13. | | | | | | 16) THE MINIMUM INSULATION REQUIRED ON CONCRETE BLOCK | | | WALLS BY THE PRESCRIPTIVE REQUIREMENTS OF ENERGY CALC. | | | FORM 600C-04R IS R-5. ON SECTION A ON A-3, R4-2 | | | INSULATION IS SPECIFIED ON SECTION A ON A-3. | | | | | | 17) THE GEOTECHNICAL SOIL REPORT FROM THE ENGINEER IS | | | REQUIRED TO BE SIGNED, SEALED AND DATED. FS 471 | | | | | | 18) FBC 106.3* CITY AMENDMENTS PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 19) THE NOA FOR THE STORM PANELS HAS BEEN REVISED BY | | | NOA NO. 05-0926.02 AND THE WRONG STATE COVERSHEET WAS | | | SUBMITTED. THE CORRECT ONE IS FL # 7226. PLEASE | | | CORRECT. | | | | | | 20) PLEASE SUBMIT AN INSTALLATION SCHEDULE INDICATING | | | THE TYPE OF MOUNT, ANCHOR TYPE, ANCHOR SPACING, EDGE | | | DISTANCE, GLASS SEPARATION, SPANS, ETC. THE APPROPRIATE | | | INFORMATION CAN BE CIRCLED ON THE PRODUCT APPROVAL. FBC | | | 106.1.2 | | | | | | 21) THE WRONG COVERSHEET WAS SUBMITTED FOR THE RIDGE | | | VENT. FL# 243 IS THE ONE THAT CORRESPONDS WITH NOA NO | | | 07-0125.01 | | | | | | 22) PLEASE DO NOT STAPLE THE PRODUCT APPROVALS TO THE | | | PLANS. SUBMITTING A RESPONSE LETTER STATINGHOW THE | | | COMMENTS WERE ADDRESSED WILL HELP CUT DOWN PLAN REVIEW | | | TIME. THANKS. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-12-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-26 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-26 |
Time |
07:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-16 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-16 |
Time |
06:41 |
Sent To |
M |
|
| Notes |
| 2007-11-16 08:41:34 | | | | | | | | | | APPLICATION #07090768 | | | ELECTRICAL PLAN REVIEW | | | 416 55TH STREET | | | 11/16/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | 1} THE DISCONNECT SHOWN ON THE RISER(S) DOES NOT | | | INDICATE A RATING. LABEL THE DISCONNECT WITH THE | | | AMPERAGE RATING INTENDED. 215.5 | | | | | | 2} PROVIDE THE AIC RATING FOR THE SERVICE EQUIPMENT | | | PER110.9-110.10. | | | | | | 3} CIRCUIT #6 IN THE ?NEW? PANEL MUST BE ARC FAULT | | | PROTECTED PER 210.12. INDICATE THE SAME ON THE | | | SCHEDULE. THE NUMBERING/NOTE SYSTEM IS SUFFICIENT. | | | | | | 4} NOTE #4 IN THE ?GENERAL ELECTRICAL NOTES? SHOULD | | | INCLUDE A REFERENCE TO 250.52(A)(3), FOOTER STEEL. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-02 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-02 |
Time |
12:52 |
Sent To |
M |
|
| Notes |
| 2007-10-02 13:25:25 | | | | | | | APPLICATION #07090768 | | | ELECTRICAL PLAN REVIEW | | | 416 55TH STREET | | | | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN | | | IS NEW OR EXISTING. IF NEW INCLUDE, AN AIC RATING. | | | | | | 2} LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, METER | | | ENCLOSURE, DISCONNECTS AND PANELS, SO THAT COMPLIANCE | | | WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | | | 3} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. SEE | | | 220.83(B) SINCE A/C IS BEING ADDED. | | | | | | 4} SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | | 440.14, RECEPTACLE PER 210.63, LIGHT PER | | | 210.70(A) (3), FOR THE AHU IN THE ATTIC. | | | | | | 5} THE GROUNDING ELECTRODE CONDUCTOR MUST COMPLY WITH | | | 250.66, #2 FOR 4/0 SERVICE CONDUCTORS. | | | | | | 6} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | | FS, RESPECTIVELY. THE CONTRACTOR OF RECORD MAY BE THE | | | DESIGN PROFESSIONAL IF EXEMPTIONS UNDER CHAPTER | | | 471.003, FLORIDA STATUTES, IF EXEMPTIONS APPLY. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-07 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-07 |
Time |
15:40 |
Sent To |
Z |
|
| Notes |
| 2008-01-07 15:40:57 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-20 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2007-12-20 17:28:25 | SENT TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-08 |
Time |
15:31 |
Sent To |
Z |
|
| Notes |
| 2007-11-08 15:31:33 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-24 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-09-28 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2007-09-28 08:28:23 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-26 |
Time |
09:54 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-12-26 |
Time |
09:54 |
Sent To |
P |
|
| Notes |
| 2007-12-26 09:55:45 | REVIEWED AND STAMPED ON 11-16-07. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-16 |
Time |
09:17 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-11-16 |
Time |
09:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-15 |
Time |
08:26 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-10-15 |
Time |
08:26 |
Sent To |
P |
|
| Notes |
| 2007-10-15 08:27:37 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-31 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-31 |
Time |
08:56 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-05 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-05 |
Time |
14:48 |
Sent To |
B |
|
| Notes |
| 2007-12-05 15:02:07 | DENIED; | | | 1. SANITARY RISER DIAGRAM DOES NOT MATCH FLOOR PLAN . | | | FLOOR PLAN SHOWS 1 LAVATORY AND A TUB. SANITARY RISER | | | DIAGRAM SHOW 2-LAVATORYS AND A SHOWER. | | | 2. TRAP SIZES ARE NOT CORRECT. SEE FBC PLUMBINGTABLE | | | 709.1. BATHTUB TRAP TO BE 1 1/2" AND THE AUTOMATIC | | | CLOTHES WASHER TRAP TO BE 2". | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-22 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-22 |
Time |
09:46 |
Sent To |
B |
|
| Notes |
| 2007-10-22 10:00:31 | DENIED; | | | 1. THE PERSON TAKING RESPONSIBITY FOR THE DRAWING MUST | | | SIGNEACH PAGE. | | | 2. SEE PLUMBING RISER DIAGRAM PAGE A-4; | | | A) AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO | | | BE 3" SEE FBC PLUMBING SECTION 406.3. | | | B) THE L-SINK SHALL DISCHARGE ABOVE THE W/M | | | BRANCH. SECTION 706.3 | | | 3. THE ADDRESS OF JOB SHOULD BE ON EACH PAGE OF THE | | | PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-09 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-09 |
Time |
08:52 |
Sent To |
PC |
|
| Notes |
| 2008-01-09 08:52:56 | ***APPROVED - RESUB #3*** | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-24 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-24 |
Time |
13:54 |
Sent To |
E |
|
| Notes |
| 2007-12-24 14:03:44 | ***FAILED - RESUB #2*** | | | | | | | | | REPEAT COMMENTS: | | | | | | 1)THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE | | | VALUE OF THE HOME.PURSUANT TO ARTICLE XIV OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), A | | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION 94-442 | | | OF THE ZLDR'S SHALL BE SUBMITTED.THE PLAN SUBMITTED | | | IS INSUFFICIENT.MUST MEET MINIMUM REQUIREMENTS FOUND | | | IN SECTION 94-442 AND 94-445 OF THE ZLDRS.FOR | | | SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHADE, | | | FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 | | | SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. FOR | | | SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHRUB SHALL | | | BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN SPACE OR | | | PORTION THEREOF.NOTE: PALM TREES DO NOT COUNT AS | | | SHADE/FLOWERING TREES.ALL TREES AND SHRUBS MUST MEET | | | MINIMUM HEIGHT REQUIREMENTS FOUND IN SECTION 94-442. | | | MY CALCULATIONS SHOW AN OPEN SPACE OF APPROX. 2550 | | | SQ.FT. WHICH WOULD REQUIRE THREE (3) TREES, THE | | | SUBMITTED LANDSCAPE PLAN SHOWS ONLY ONE (1) TREE WITHIN | | | THE PROPERTY LINES. | | | | | | 2)THE A/C UNIT LOCATION IS INCONSISTENT BETWEEN | | | PLANS.ALL PLANS TO BE CONSISTENT AND SHALL INDICATE | | | SETBACK DIMENSIONS FROM PROPOSED A/C EQUIPMENT TO THE | | | PROPERTY LINES.AS PER SECTION 94-305(B)(4) OF THE | | | ZLDRS: MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN | | | 4' INTO A REQUIRED SETBACK. | | | | | | PLEASE DO NOT HESITATE TO CALL WITH QUESTIONS. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-14 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-14 |
Time |
12:53 |
Sent To |
E |
|
| Notes |
| 2007-11-14 12:53:00 | ***FAILED - RESUB #1*** | | | | | | | | | REPEAT COMMENTS: | | | | | | 1)THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE | | | VALUE OF THE HOME.PURSUANT TO ARTICLE XIV OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS(ZLDRS), A | | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION 94-442 | | | OF THE ZLDR'S SHALL BE SUBMITTED.PLAN SUBMITTED IS | | | INSUFFICIENT.MUST MEET MINIMUM REQUIREMENTS FOUND IN | | | AFOREMENTIONED SECTION.FOR SINGLE-FAMILY DWELLING | | | UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT TREE | | | SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN | | | SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY DWELLING | | | UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 | | | SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.NOTE: | | | PALM TREES DO NOT COUNT AS SHADE/FLOWERING TREES.ALL | | | TREES AND SHRUBS MUST MEET MINIMUM HEIGHT REQUIREMENTS | | | FOUND IN SECTION 94-442. | | | | | | 2)INDICATE LEGIBLE HEIGHT DIMENSIONS OF THE PROPOSED | | | ADDITION FROM GRADE TO THE MIDPOINT OF THE ROOFS PITCH. | | | (DIMENSION IS CUTOFF ON PLANS) | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-28 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-28 |
Time |
14:01 |
Sent To |
E |
|
| Notes |
| 2007-09-28 14:04:42 | ***FAILED*** | | | | | | | | | 1)VALUE OF PROPOSED WORK EXCEEDS 50% OF THE VALUE OF | | | THE HOME.PURSUANT TO ARTICLE XIV OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS(ZLDRS), A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTION 94-442 OF THE ZLDR'S | | | SHALL BE SUBMITTED. | | | | | | 2)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED A/C | | | EQUIPMENT TO THE PROPERTY LINES. | | | | | | 3)INDICATE LEGIBLE HEIGHT DIMENSIONS OF THE | | | PROPOSED. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|