| Plan Review Stops For Permit 07090747 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-10 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-10 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2008-04-10 15:41:27 | BUILDING PLAN REVIEW | | | PERMIT: 07090747 | | | ADD: 307 EVERNIA STREET #100 | | | CONT: G3 CONST. | | | TEL: (561)393-3939 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4-10-08 | | | REVIEW: REVISION | | | ACTION: DENIED | | | | | | NOTE: THESE NOTES ARRE IN REFERENCE TO THE EXHAUST WALL | | | CAP WITH WMS ON SHEET M1.1 | | | | | | 1)FBC 1403.2 THE EXTERIOR WALL ENVELOPE SHALL BE | | | DESIGNED AND CONSTRUCTED IN SUCH A MANNER AS TO PREVENT | | | THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY | | | PROVIDING A WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR | | | VENEER, AS DESCRIBED IN SECTION 1404.2 AND A MEANS FOR | | | DRAINING WATER THAT ENTERS THE ASSEMBLY TO THE EXTERIOR | | | OF THE VENEER, UNLESS IT IS DETERMINED THAT PENETRATION | | | OF WATER BEHIND THE VENEER SHALL NOT BE DETRIMENTAL TO | | | THE BUILDING PERFORMANCE. | | | | | | 2)FBC 1203. NATURAL VENTILATION OF AN OCCUPIED SPACE | | | SHALL BE THROUGH WINDOWS, DOORS, LOUVERS OR OTHER | | | OPENINGS TO THE OUTDOORS. THE OPERATING MECHANISM FOR | | | SUCH OPENINGS SHALL BE PROVIDED WITH READY ACCESS SO | | | THAT THE OPENINGS ARE READILY CONTROLLABLE BY THE | | | BUILDING OCCUPANTS. | | | | | | 3)1609.1.4 (5.) LOUVERS PROTECTING INTAKE AND EXHAUST | | | VENTILATION DUCTS NOT ASSUMED TO BE OPEN THAT ARE | | | LOCATED WITHIN 30 FEET OF GRADE SHALL MEET REQUIREMENTS | | | OF THE LARGE MISSILE TEST. | | | IMPACT-RESISTANT COVERINGS SHALL BE TESTED AT 1.5 TIMES | | | THE DESIGN PRESSURE (POSITIVE OR NEGATIVE) EXPRESSED IN | | | POUNDS PER SQUARE FEET AS DETERMINED BY THE FLORIDA | | | BUILDING CODE, BUILDING SECTION 1609 FOR WHICH THE | | | SPECIMEN IS TO BE TESTED. | | | | | | 4)PROVIDE PRODUCT APPROVAL FOR THE LOUVER PER DCA | | | RULE 9B-72, WHICH STATES ?THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL. | | | SUBMIT TWO COPIES OF PRODUCT APPROVAL FOR THE LOUVER | | | AND SHOW HOW IT WILL PREVENT WATER INTRUSION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-02-15 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-02-15 |
Time |
06:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-10 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-10 |
Time |
14:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-12-19 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-12-19 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2007-12-21 08:54:40 | BUILDING PLAN REVIEW | | | PERMIT: 07090747 | | | ADD: 307 EVERNIA ST | | | CONT: RIZNICK CONSTRUCTION CORP. | | | TEL: (561) 584-0363 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/2006 AND 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 3RD | | | ACTION: DENIED | | | 12/19/07 | | | | | | 1A) | | | | | | 1B) OK | | | 1D) OK | | | 1E) OK | | | 2)OK | | | 3)OK | | | | | | **NO RESPONSE NOT ADDRESSED** | | | 4)PROVIDE THE WALL DETAIL OF EACH WALL ENCLOSING THE | | | NEW SERVER ROOM AND SUBMIT THE UL LISTING OF THE WALLS | | | AND THE MANUFACTURE SPECS FOR THE FIRE RATED DOOR. A | | | WALL LEGEND WILL BE HELPFUL TO IDENTIFY EACH TYPE OF | | | WALL. THE FLOOR AND UNIT NUMBER OF THE PROJECT SHALL BE | | | INDICATING ON THE APPLICATION AND EACH SHEET OF THE | | | DRAWINGS. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE, AND EXTENT OF | | | THE WORK PROPOSED. WPB AMENDMENTS 106.1.1. **THE DETAIL | | | FOR THE EXTENSION OF THE EXISTING WALL TO THE SLAB | | | ABOVE SHALL BE SHOWN ON THE DRAWINGS. | | | | | | **NEW** | | | THE DRAWINGS SUBMITTED ARE NOT SIGN, DATED OR SEAL BY | | | THE ARCHITECT. ALL FINAL CONSTRUCTION DOCUMENTS, | | | DRAWINGS, PLANS AND SPECIFICATIONS, OR REPORTS PREPARED | | | OR ISSUED BY THE REGISTERED ARCHITECT SHALL BEAR THE | | | SIGNATURE AND SEAL OF THE REGISTERED ARCHITECT WHO | | | PREPARED OR APPROVED THE DOCUMENT AND THE DATE ON WHICH | | | THEY WERE SEALED. THE SIGNATURE, DATE, AND SEAL SHALL | | | BE EVIDENCE OF THE AUTHENTICITY OF THAT TO WHICH THEY | | | ARE AFFIXED. FLORIDA STATUTES 481.221 | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-11-27 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-11-27 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2007-11-28 09:51:12 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07090747 | | | ADD: 307 EVERNIA ST | | | CONT: RIZNICK CONSTRUCTION CORP. | | | TEL: (561) 584-0363 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/2006 AND 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION: DENIED | | | 11/27/07 | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) OK | | | 1D) OK | | | 1E) OK | | | 2)OK | | | | | | **NO RESPONSE NOT ADDRESSED** | | | 3)PROVIDE A DETAIL ELEVATION DRAWING OF THE MOUNTING | | | UNIT RACKS AND SHOW HOW THE RACKS WILL BE ATTACHED TO | | | EXISTING FLOOR. STATE CLEARLY ON THE DETAIL DRAWING | | | WHAT MATERIALS WILL BE USED TO CONSTRUCT THE MOUNTING | | | RACKS.ADDITIONAL DETAILS INFORMATION IS REQUIRED FOR | | | THE NEW SEVER RACKS WHERE THE UNITS WILL BE 18 INCHES | | | OFF THE FLOOR. WPB AMENDMENTS SECTION 106.1.2. | | | **NO RESPONSE NOT ADDRESSED**4)PROVIDE THE WALL | | | DETAIL OF EACH WALL ENCLOSING THE NEW SERVER ROOM AND | | | SUBMIT THE UL LISTING OF THE WALLS AND THEMANUFACTURE | | | SPECS FOR THE FIRE RATED DOOR. A WALL LEGEND WILL BE | | | HELPFUL TO IDENTIFY EACH TYPE OF WALL. THE FLOOR AND | | | UNIT NUMBER OF THE PROJECT SHALL BE INDICATING ON THE | | | APPLICATION AND EACH SHEET OF THE DRAWINGS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE, AND EXTENT OF THE | | | WORK PROPOSED. WPB AMENDMENTS 106.1.1. | | | | | | **NEW** | | | THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS LOW. | | | FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING | | | LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD), | | | MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER | | | 108.3FBC* | | | NOTE: THIS NEW ROOM NEEDS A 1 HOUR FIRE SEPERATION FROM | | | OTHER ROOMS. SEE ELECTRICAL NOTE #4. THE 1HOUR RATED | | | NOTE WAS REMOVED FROM THE NEW SETS OF DRAWINGS. GIVE AN | | | EXPLAINATION WHY. | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-17 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-17 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2007-10-17 16:14:30 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07090747 | | | ADD: 307 EVERNIA ST | | | CONT: RIZNICK CONSTRUCTION CORP. | | | TEL: (561) 584-0363 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/2006 AND 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | 10/17/07 | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 REVISIONS. | | | | | | 2)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 3)PROVIDE A DETAIL ELEVATION DRAWING OF THE MOUNTING | | | UNIT RACKS AND SHOW HOW THE RACKS WILL BE ATTACHED TO | | | EXISTING FLOOR. STATE CLEARLY ON THE DETAIL DRAWING | | | WHAT MATERIALS WILL BE USED TO CONSTRUCT THE MOUNTING | | | RACKS.ADDITIONAL DETAILS INFORMATION IS REQUIRED FOR | | | THE NEW SEVER RACKS WHERE THE UNITS WILL BE 18 INCHES | | | OFF THE FLOOR. WPB AMENDMENTS SECTION 106.1.2. | | | | | | 4)PROVIDE THE WALL DETAIL OF EACH WALL ENCLOSING THE | | | NEW SERVER ROOM AND SUBMIT THE UL LISTING OF THE WALLS | | | AND THE MANUFACTURE SPECS FOR THE FIRE RATED DOOR. A | | | WALL LEGEND WILL BE HELPFUL TO IDENTIFY EACH TYPE OF | | | WALL. THE FLOOR AND UNIT NUMBER OF THE PROJECT SHALL BE | | | INDICATING ON THE APPLICATION AND EACH SHEET OF THE | | | DRAWINGS. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE, AND EXTENT OF | | | THE WORK PROPOSED. WPB AMENDMENTS 106.1.1. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-09 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-09 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2008-04-09 12:27:45 | ** DENIED REVIEW** | | | | | | ** PLANS PLACED ON COMM BOARD ON 4/9 | | | | | | 1) NOTE: SUBMITTED REVISIONS WERE COUNTER TO BE ONLY | | | ONE SHEET HOWEVER THERE WERE FOUR SHEETS IN SETS | | | SUBMITTED SETS. WILL OWE $30.00 ADDITIONAL FEE. | | | | | | 2) NOTE: PLEASE BE SURE TO SUBMIT ANY REVISIONS FOR | | | LAYOUTS AND EQUIPMENT IN ELECTRICAL PLANS DONE BY THE | | | ENGINEER OF RECORD. | | | NO ELECTRICAL PLANS SUBMITTED AT THIS TIME. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-08 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-08 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2008-01-08 12:30:52 | SPECS SUBMITTEDARE NOT THE MTS AS STATED ON PLANS. | | | PLANS PASSED PENDING CONFIRMATION FROM ENGINEER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-07 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-07 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2008-01-07 08:20:51 | ***TEMP FAILED STATUS. | | | | | | 1) NOTE: PLEASE SUBMIT THE MANUFACTURE'S SPECS/CUT | | | SHEETS ON THE MTS. THESE WERE REQUESTED ON ORIGINAL | | | REVIEW AND WERE SUBMITTED PREVIOUSLY HOWEVER ARE NO | | | LONGER IN PACKAGE. | | | THESE CAN BE BROUGHT IN AT ANY TIME WHILE REVIEWS ARE | | | BEING DONE. PLEASE CONTACT THIS REVIEWER IF THERE ARE | | | ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-19 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-19 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2007-12-19 12:21:39 | ** DENIED 3RD REVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE BOTH SETS OF PLANS SUBMITTED | | | CONTAIN REVISED ARCHITECTURAL AND ELECTRICAL SHEETS | | | WHICH ARE NOT SIGNED, DATED OR SEALED BY THE | | | RESPONSIBLE DESIGNERS OF RECORD. | | | PLEASE SEE FAC 61G1-16, 61G15-23.002, FS 471.025 AND | | | 481.221. | | | | | | 2) NOTE: PLEASE SEE PLANS ARE NOW INDICATING ON SOME OF | | | THE ARCHITECTURAL SHEETS THAT NO FIRE RATE WALLS WILL | | | BE PROVIDED AND WIRING METHODS SHALL MEET CHAPTERS 1-4 | | | OF THE ELECTRICAL CODE. | | | PLEASE SEE THAT PLANS SPECIFICALLY STILL STATE DESIGN | | | IS TO MEET NFPA-75 2003 WHEN THIS IS APPARENTLY NOT THE | | | DESIGN SHOWN ON PLANS. | | | PLEASE BE SURE THE ELECTRICAL PLANS STATE THE WIRING | | | METHODS AND REMOVE ANY ?IT? ROOM OR EQUIPMENT | | | DESIGNATIONS. AS THIS IS NOT AN IT ROOM, ALL WIRING | | | METHODS SHALL MEET THE MORE RESTRICTIVE CODES AS NOTED | | | ABOVE. | | | BELOW IS THE COMMENTARY TO 645.4 | | | **USE OF THE REQUIREMENTS IN ARTICLE 645 IS BASED ON | | | THE ASSUMPTION THAT CONSTRUCTION OF THE INFORMATION | | | TECHNOLOGY EQUIPMENT (ITE) ROOM COMPLIES WITH NFPA 75, | | | STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY | | | EQUIPMENT. FOR THOSE ITE ROOMS CONSTRUCTED IN | | | ACCORDANCE WITH NFPA 75, ARTICLE 645 CONTAINS | | | ELECTRICAL INSTALLATION REQUIREMENTS THAT ARE LESS | | | STRINGENT THAN THE REQUIREMENTS IN THE FIRST FOUR | | | CHAPTERS OF THE CODE. APPLICATION OF THESE PROVISIONS | | | IS CONTINGENT ON THE ITE ROOM CONSTRUCTION AND | | | EQUIPMENT MEETING ALL FIVE PROVISIONS SPECIFIED IN | | | 645.4. FOR EXAMPLE, THE PROVISIONS FOR WIRING | | | INSTALLATIONS IN THE SPACE BENEATH THE RAISED FLOOR OF | | | AN ITE ROOM WHERE THAT SPACE IS ALSO USED FOR | | | ENVIRONMENTAL AIR ARE LESS STRINGENT THAN THOSE IN | | | CHAPTERS 1 THROUGH 4 FOR THAT SAME TYPE OF SPACE. THE | | | LESS RESTRICTIVE PROVISIONS IN ARTICLE 645 CANNOT BE | | | TAKEN ADVANTAGE OF IF ANY ONE OF THE CONDITIONS | | | SPECIFIED IN 645.4 IS ABSENT.** | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-26 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-26 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2007-11-26 13:36:31 | ** DENIED 2ND REVIEW ** | | | | | | 1) NOTE: PLEASE SEE THE PERMIT APPLICATION STILL DOES | | | CONTAIN THE SUITE/UNIT # AS PREVIOUSLY REQUESTED. | | | | | | 2) NOTE: PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE OF | | | WORK SHALL INCLUDE ALL LABOR, ALL MATERIALS, EQUIPMENT, | | | DESIGN COST ETC EVEN FOR OTHER WORK WHICH IS DONE UNDER | | | SUB PERMITS. | | | THIS IS ALSO IF ANY OF THE EQUIPMENT IS OWNER SUPPLIED. | | | (IT EQUIPMENT) | | | AS THE SUB-PERMITS ONLY PAY A $50 FEE, THEIR COMPLETE | | | VALUE FOR SCOPE OF WORK ON PLANS SHALL BE INCLUDED. | | | | | | 3) NOTE: PLEASE SEE THAT NO MANUFACTURE SPECS/CUT | | | SHEETS WERE SUBMITTED. | | | PLANS DO MENTION THE IT RACK EQUIPMENT IS NIC. PLEASE | | | KNOW THIS MAY BE ARRANGED SO THAT OTHER EQUIPMENT IS | | | SUBMITTED UNDER SEPARATE PERMIT, PLANS AND FEES AT A | | | LATER DATE AND BEFORE INSTALLATION. | | | FBC 106.1, 106.3.5.1.2, 106.1.2 | | | | | | 4) NOTE: PLEASE EXPLAIN WHY THE RATING OF THE WALLS HAS | | | BEEN DELETED FROM THE A-SHEETS. PLEASE SEE MINIMUM | | | RATINGS FOR WALLS PER NFPA-75 CHAPTER 5 AND NEC 645.7. | | | PLEASE ALSO SEE POSSIBLE BUILDING REVIEW COMMENTS. | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-16 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-16 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2007-10-16 10:37:56 | **** DENIED **** | | | | | | | | | 1) NOTE: ** PERMIT APPLICATION NEEDS TO INDICATE THE | | | FLOOR/SUITE/UNIT # IN WHICH THE WORK IS BEING DONE. | | | THIS WILL NEED TO BE CORRECTED IN OUR SYSTEM AS WELL | | | AND APPLICATION. | | | FBC 110.1.2, FAC 61G1-16.004, 61G15-23.002 | | | | | | 2) NOTE:PLEASE BE SURE ALL OF THE FOLLOWING RELEVANT | | | CODES ARE STATED ON PLANS. | | | 2003 NFPA-75 | | | | | | ** PLEASE BE SURE TO SEE COMMENTS FROM OTHER TRADES FOR | | | CODES. | | | | | | 3) NOTE: PLEASE SEE THE VALUE FOR COMPLETE SCOPE OF | | | WORK IS TO INCLUDE ALL LABOR, ALL MATERIALS, AND ALL | | | EQUIPMENT, DESIGN COST ETC EVEN IF ANY OF THESE ARE | | | OWNER SUPPLIED. | | | THIS INCLUDES IT EQUIPMENT. | | | FBC 108.3 | | | ** PLEASE KNOW AS THE CERTAIN SUB PERMITS (ELECTRICAL) | | | DO NOT PAY FEES BASED ON VALUE, THE COMPLETE SCOPE OF | | | WORK VALUE SHALL BE ON BASE PERMIT. | | | PLEASE SEE COMMENTS FROM OTHER TRADES WHICH ALSO MAY BE | | | NOTED. | | | | | | 4) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR THE MTS. | | | 90.7, 110.3 | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR THE PROPOSED IT EQUIPMENT. 90.7, 110.3 | | | PLEASE BE SURE ALL SPECS/CUT SHEETS CONTAIN LISTINGS | | | FROM A NATIONALLY RECOGNIZED TESTING LABORATORY. | | | (NRTL). | | | PLEASE CLARIFY IF THERE WILL BE ANY UPS EQUIPMENT? | | | 645.11 | | | PLEASE CLARIFY THE PLANS WHICH INDICATE A CONTROL PANEL | | | HOWEVER IT IS NOT CLEAR WHAT THIS CONTROL PANEL DOES. | | | PLEASE SEE 645.10 FOR POSSIBLE DISCONNECTING MEANS OF | | | ELECTRICAL EQUIPMENT IN ROOM WHICH. | | | PLEASE KNOW AT THIS TIME SOME ITEMS CAN NOT BE REVIEWED | | | FOR CODE COMPLIANCE. | | | | | | 6) NOTE: PLEASE COMPLETE LIGHTING POWER DENSITIES FOR | | | NEW LIGHTING IN ROOM. | | | 13-415.2 | | | | | | 7) NOTE: PLEASE SEE THAT ANY NEW LIGHTING CONTROL | | | DEVICES WILL BE REQUIRED TO MEET 13-415.1.ABC.1.1/.1.2. | | | THIS IS ONLY FOR THE NEW ROOM AND LIGHTING CONTROL FOR | | | THAT ROOM. | | | | | | 8) NOTE: PLEASE SEE RISER WHICH SHOWS AN OCTAGONAL NOTE | | | #7 WHICH ON FEEDER SCHEDULE MENTIONS #4 FOR EQUIPMENT | | | GROUND. THE RISER SHOWS #3 WITH THE 500MCM WHICH IS | | | CORRECT PER 250.122 HOWEVER THE #4 AS ON KEY NOTES IS | | | TOO SMALL. | | | PLEASE ADJUST. | | | | | | | | | ** PLEASE KNOW AS THERE ARE SEVERAL ITEMS NOT YET | | | COMPLETED ON PLANS FOR REVIEW, NOT ALL COMMENTS MAY BE | | | PRESENT AT THIS TIME. | | | | | | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES WHICH WILL | | | AFFECT PLANS, SUBMITTED DOCUMENTS AND ELECTRICAL | | | PLANS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
F |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-14 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-12 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2008-04-12 17:15:15 | *****PROVISO***** | | | | | | THE REVISED PLAN SHEETS A1-3, A1-4, FP1.1, AND ANY | | | OTHER SHEETS AFFECTED BY THE REVISIONS WILL BE | | | FIRE-STAMPED WHEN THE OTHER REVIEWERS HAVE BEEN | | | SATISFIED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-02-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-13 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-13 |
Time |
14:40 |
Sent To |
M |
|
| Notes |
| 2008-02-13 15:23:19 | *****REVISION #4, DATED 01/22/2008, APPROVED***** | | | | | | REVISED PLAN SHEETS FP1.1 AND D1-2 WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-01-10 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-01-10 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2008-01-10 13:10:47 | *****APPROVED***** | | | | | | PLAN SHEETS D1.1, A1.3, E2.1, AND FP1.1 WERE | | | RE-STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-20 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-20 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2007-12-20 14:48:59 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADRESSED;PLAN SHEETS D1.1, A1.3, E2.1, AND FP1.1 | | | WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-29 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-29 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2007-11-29 12:52:43 | *****DENIED***** | | | | | | THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEED TO BE ADRESSED: | | | | | | 1.THE COMPLETE ADDRESS OF THE PROJECT SITE, INCLUDING | | | SUITE NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET.ADDRESS MISSING ON SHEETS | | | FP1.1, M1.1 | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. ADD | | | COMMENT TO SHEET D1-1 | | | | | | 3.THE BUILDING AND/OR TENANT SPACE SHALL BE PERMITTED | | | TO BE OCCUPIED DURING THE SCOPE OF WORK ONLY WHERE | | | REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION | | | FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED. ADD | | | COMMENT TO SHEET D1-1 | | | | | | 4.WHERE ALTERATION REQUIRES MODIFICATION OF A PORTION | | | OF THE FIRE PROTECTION SYSTEM, THE REMAINDER OF THE | | | SYSTEM SHALL BE KEPT IN SERVICE AND THE FIRE DEPARTMENT | | | SHALL BE NOTIFIED.ADD COMMENT TO SHEET FP1-1 | | | | | | 7.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | | NEW FM-200 FIRE SUPPRESSION SYSTEM.ADD COMMENT TO | | | SHEET A1-3 | | | | | | 8.THE NEW FIRE DOOR AND WINDOW SHALL BE IN ACCORDANCE | | | WITH NFPA 80.ADD COMMENT TO SHEET A1-3 | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-18 |
Time |
23:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-18 |
Time |
21:26 |
Sent To |
|
|
| Notes |
| 2007-10-18 23:43:00 | *****DENIED***** | | | | | | | | | 1.THE COMPLETE ADDRESS OF THE PROJECT SITE, INCLUDING | | | SUITE NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.THE BUILDING AND/OR TENANT SPACE SHALL BE PERMITTED | | | TO BE OCCUPIED DURING THE SCOPE OF WORK ONLY WHERE | | | REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION | | | FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED. | | | | | | 4.WHERE ALTERATION REQUIRES MODIFICATION OF A PORTION | | | OF THE FIRE PROTECTION SYSTEM, THE REMAINDER OF THE | | | SYSTEM SHALL BE KEPT IN SERVICE AND THE FIRE DEPARTMENT | | | SHALL BE NOTIFIED. | | | | | | 5.NFPA 101, LIFE SAFETY CODE, 2003 EDITION AND THE | | | FLORIDA FIRE PREVENTION CODE 2004 SHALL BE REFERENCED. | | | | | | 6.NFPA 75,PROTECTION OF INFORMATION TECHNOLOGY | | | EQUIPMENT, 2003 EDITION SHALL BE REFERENCED. | | | | | | 7.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | | NEW FM-200 FIRE SUPPRESSION SYSTEM. | | | | | | 8.THE NEW FIRE DOOR AND WINDOW SHALL BE IN ACCORDANCE | | | WITH NFPA 80. | | | | | | 9.SPECIFY THE NEW WALL AND CEILING FINISH MATERIALS | | | IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-09 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-09 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2008-04-09 11:20:50 | PLANS ROUTTED TO "COMM" BD#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-28 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-28 |
Time |
13:26 |
Sent To |
FIRE |
|
| Notes |
| 2008-03-28 13:26:47 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-01 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-01 |
Time |
09:24 |
Sent To |
FIRE |
|
| Notes |
| 2008-02-01 09:24:23 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-04 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-04 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2008-01-04 16:33:07 | TO "BOB"#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-14 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-14 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2007-12-14 10:31:18 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-15 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-15 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2007-11-19 10:01:07 | TO "BOB"#3 | | 2007-11-15 10:04:05 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-22 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-27 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2007-10-15 11:08:20 | TO "BOB"#12 | | 2007-09-27 11:28:38 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-11 |
Time |
13:32 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-11 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2008-04-11 13:34:48 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | ** REVISION TO MECHANICAL PLAN M1.1** | | | *** DENIED *** | | | 1) SEE BUILDING REVIEW NOTES REGARDING THE EXHAUST WALL | | | CAP, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2008-02-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-14 |
Time |
08:35 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-02-14 |
Time |
08:35 |
Sent To |
B |
|
| Notes |
| 2008-02-14 08:50:03 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | ** MECHANICAL REVISION PAGE M1.1 ** | | | | | | *** DENIED *** | | | 1) THE A/C CONDENSATE LINE MAY NOT CONNECT INTO THE | | | STORM RISER AT THAT POINT, IT MUST GO TEN FEET FROM THE | | | BUILDING THEN TIE-IN TO THE STORM RISER WITH A RELIEF | | | VENT. ALSO A CHECK VALVE WOULD STOP THE CONDENSATE | | | WATER FROM GETTING PAST AS IT IS NOT UNDER PRESSURE. | | | THERE ARE ALSO OTHER OPTIONS TO DISPOSE OF THE | | | CONDENSATE WATER. PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-08 |
Time |
09:51 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-01-08 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2008-01-08 09:53:04 | PASSED REVIEW ON 12-17-07. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-17 |
Time |
16:04 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-12-17 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-27 |
Time |
16:05 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-11-27 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2007-11-27 16:06:06 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 10-18-07.THE JOB ADDRESS | | | NEED TO BE IN THE TITLE BLOCK OF EACH PAGE OF THE | | | PLANS, SEE W.P.B. 106.1.3. SEE MECHANICAL PLAN PAGE | | | M1.1 MISSING ADDRESS. | | | | | | 2) PLAN A1-3STATES,NEW CONDENSING UNIT FOR NEW | | | LIEBERT A/C SYSTEM, ETC. ETC. AND ENDS WITH "VERIFY | | | WITH ENGINEER". NO ENGINEERING WITH WIND LOAD | | | CALCULATIONS SHOWING THAT THE TRELLIS WITH THE | | | CONDENSER UNIT ON TOP WILL WITHSTAND 140 MPH WINDS WAS | | | SUBMITTED. PLEASE COMPLY WITH 2004 FBC 1609 AS | | | REQUESTED IN LAST REVIEW 10-18-07. | | | | | | 3)SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING | | | FOUR TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-18 |
Time |
07:56 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-10-18 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2007-10-18 08:04:43 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE JOB ADDRESS NEED TO BE IN THE TITLE BLOCK OF | | | EACH PAGE OF THE PLANS, SEE W.P.B. 106.1.3. | | | | | | 2) NEED A ENGINEERING DETAIL SHOWING HOW THE A/C | | | CONDENSER METAL BRACKET IS TO BE CONSTRUCTED AND | | | SECURED TO THE WALL, ALSO HOW THE A/C CONDENSER UNIT IS | | | TO BE SECURED TO THE METAL BRACKET ALL TO WITHSTAND 140 | | | MPH WINDS, PER 2004 FBC 1609. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-22 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-22 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2007-10-22 09:30:53 | NO PLUMBING SHOWN ON PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-01-09 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-01-09 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-12-19 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-12-19 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2007-12-19 11:17:31 | ZONING REVIEW: PASSED | | | | | | * INTERIOR RENOVATION AND EXTERIOR MOD AT REAR | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-12-02 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-12-02 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-12-02 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-10-22 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-10-22 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2007-10-22 08:32:55 | ZONING REVIEW: FAILED | | | | | | * PLEASE CONFIRM EQUIPMENT PLACEMENT WILL NOT IMPACT | | | ABILITY TO ACCESS DUMPSTER/COMPACTOR | | | | | | MATT FLIS - 822-1445 |
|
|