| 2007-10-11 15:55:09 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: |
| | |
| | |
| | 1 PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR |
| | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP |
| | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FROM |
| | 1000, 45 STREET FOR ALL THESE CITY STANDARDS NOTES. |
| | PHONE# 494-1040 |
| | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE |
| | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 3. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED |
| | FLOOD ZONE AREA, & WORST ONE, 100 YEAR FLOOD CRITERIA |
| | TO DETERMINE THE FIRST FLOOR ELEVATION, PARKING LOT |
| | ELEVATION, CROWN OF THE ROAD ELEVATION, SIDEWALK ETC. |
| | 4. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, |
| | GREEN , LAKE, PARKING AREA, IMPERVIOUS,PERVIOUS AREA |
| | YOU ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE |
| | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH |
| | AND USED IN STORM WATER QUALITY CALCULATIONS. |
| | 5. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE |
| | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM |
| | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE |
| | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR |
| | EXFILTRATION TRENCHES IF YOU HAVE IT,, PLEASE SHOW DRY |
| | DETENTION/WET DETENTION AREAS IN STORM WATER CALS. |
| | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND |
| | YOUR SITE FOR STORM WATER DRAIN. |
| | 7. PLEASE PROVIDE A COPY OF SFWMD OR NORTH IMPROVEMENT |
| | DISTRICT PERMIT, BECAUSE IT IS MORE THAN 2 ACRES, & |
| | RESUBMIT STORM WATER QUALITY CALCULATIONS. STORM WATER |
| | CALS MUST BE APPROVED FROM 100045TH STREET |
| | ENGINEERING SERVICES BEFORE WE APPROVE. |
| | 8. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT |
| | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE |
| | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & |
| | PARTICLES. |
| | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.),OR EMERY F.,, UTILITY DEPT BEFORE WE |
| | APPROVED. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |