| Plan Review Stops For Permit 07090628 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-08 |
Time |
09:07 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2009-04-08 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-16 |
Time |
13:26 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-06-16 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-16 |
Time |
16:43 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2007-10-16 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2007-10-16 16:50:15 | BUILDING PLAN REVIEW | | | PERMIT: 07090628 | | | ADD: 2800 N FLAGLER DR | | | CONT: SCHEHR CONSTRUCTION | | | TEL: (954)415-5705 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. | | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE2007 REVISIONS. | | | | | | 2) SHEET 7 OF 8 GENERAL NOTES WIND THE IMPORTANCE | | | FACTOR IS PROVIDED AS 1.0 PLEASE SEE ASCE 7-02 TABLE | | | 1-1DESIGNATED EMERGENCY PREPAREDNESS, COMMUNICATIONS | | | THIS SITE AND ALL CELLULAR TOWERS ARE REQUIRED BY STATE | | | STATUTE TO HAVE THE GENERATOR BACKUP AS PART OF THE | | | DESIGNATED EMERGENCY COMMUNICATIONS SYSTEMS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-07 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-07 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2009-04-07 15:15:56 | 8 HRS REQUIRED BACK UP PROVIDED BY BATTERIES. | | | SIGNAGE FOR FUEL SHUT OFF. | | | FIRE COMMAND RM ANNUNCIATOR | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-06-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-13 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-13 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2008-06-13 14:36:20 | ** DENIED ** | | | | | | 1) NOTE: PLEASE SHOW LOCATION OF PROPOSED FUEL SHUT OFF | | | IN THE PROXIMITY OF THE MAIN ELECTRICAL SWITCH GEAR. | | | PLEASE PROVIDE NOTES AND ACTUAL WORDING FOR PROPOSED | | | SIGNAGE AT THE MAIN ELECTRICAL EQUIPMENT LOCATION AS | | | WELL AS ANY FIRE COMMAND ROOM, ACTUAL FUEL SHUT OFF | | | LOCATION AND FIRE ENUNCIATOR LOCATION. ANY SIGNAGE IN | | | BUILDING WHICH DIRECT EMERGENCY PERSONNEL TO THE | | | LOCATIONS TO SHUT DOWN POWER ETC IN AN EMERGENCY SHALL | | | BE STATED ON PLANS AND WILL BE VERIFIED IN FIELD. | | | | | | AS STATED IN PART 12 OF TITLE 47 THE TIME FOR BACK UP | | | ARE REQUIRED TO BE A MINIMUM OF 8HRS. PLEASE SHOW THE | | | EXISTING BATTERY BACK UP UNITS. | | | | | | AS PLANS ARE COMING BACK FOR COMMENTS PLEASE SUPPLY AT | | | THIS TIME. | | | | | | ** AS STATED ON PREVIOUS AS NOT ALL ITEMS ARE SHOWN AS | | | OF YET THERE MAY BE NEW COMMENTS ON THE FOLLOWING | | | REVIEW WHICH CAN NOT BE MADE AT THIS TIME. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-14 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-14 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2007-10-14 14:23:15 | | | | ** DENIED** | | | | | | 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS | | | WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES | | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-110 ( FBC CHAPTER 27 REFERENCED. | | | | | | 2) NOTE: PLEASE SEE THIS APPEARS BY ALL INFORMATION TO | | | THIS REVIEWER TO BE A LEGALLY REQUIRED SYSTEM PER FS | | | 365.172 AND TITLE 47 OF FEDERAL REGULATION CODES WHICH | | | WOULD REQUIRED A ON-SITE FUEL FOR BACK UP OF THE | | | GENERATOR PER 701.11B3 AND NFPA-1221 | | | PLEASE SEE REQUIREMENTS FROM THE FIRE MARSHAL AS A | | | *ROOF-TOP* LP MAY NOT BE PERMITTED. | | | | | | 3) NOTE: PLEASE CLARIFY HOW THE DISCONNECTING MEANS FOR | | | POWER TO BUILDING IS GROUPED OR IN CLOSE PROXIMITY. | | | 230.72. | | | THE *SHUNT-TRIP* KILL SWITCH AS SHOWN DOES NOT MEET THE | | | REQUIREMENTS OF 230.76, 230.79. | | | ** A COMPLETE SHUT DOWN OF FUEL SUPPLY WOULD BE | | | REQUIRED AT A MINIMUM. LOCATION ETC WOULD NEED TO BE | | | GONE OVER ONCE ALL REVIEWS ARE DONE FROM ALL TRADES. | | | | | | 4) NOTE: PLEASE SUBMIT MANUFACTURES SPECS/CUT SHEET | | | WHICH CORRELATE WITH PLANS AND PERMIT APPLICATION FOR | | | GENERATOR. SPECS/CUT SHEETS INDICATE 25 AND 27KW UNIT, | | | NOT 30. | | | 90.7, 110.3 | | | | | | 5) NOTE: PLEASE PROVIDE LOAD ON THE GENERATOR AND TIME | | | ON ON-SITE FUEL TO BE DETERMINED.701.5 | | | | | | 6) NOTE: PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE OF | | | WORK INCLUDING ALL LABOR, MATERIALS AND EQUIPMENT EVEN | | | IF ANY OF THESE ITEMS ARE SUPPLIED BY THE OWNER. AS GAS | | | IS APPLIED FOR AT THIS TIME, THIS VALUE SHALL ALSO BE | | | INCLUDED. | | | PLEASE KEEP IN MIND AS SCOPE OF MAY CHANGE DUE TO | | | COMMENTS, THE VALUE MAY ALSO NEED TO BE ADJUSTED. THIS | | | ALSO INCLUDES VALUE FOR DESIGN FEES (PLANS). FBC 108.3 | | | | | | ** PLEASE KNOW AS NOT ALL INFORMATION WAS SUBMITTED FOR | | | REVIEW AND DUE TO COMMENTS ABOVE, THERE MAY VERY WELL | | | BE NEW COMMENTS ON THE FOLLOWING REVIEW. | | | NOTES CAN ONLY BE GIVEN BASED ON PLANS/DOCUMENTS | | | SUBMITTED. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-04-14 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-04-14 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2009-04-14 12:34:37 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED; PLAN SHEETS 3 & 7 (OF 7) AND ELECTRICAL | | | SITE PLAN (1 OF 1) WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-30 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-30 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2008-06-30 14:32:45 | ***DENIED*** | | | | | | PLEASE SEE ATTACHED COMMENTS FROM FIRST FIRE PLAN | | | REVIEW. ALTHOUGH A RESPONSE LETTER IS NOT MANDATORY, IT | | | WOULD BE HELPFUL AS THIS WRITER DID NOT CONDUCT THE | | | FIRST PLAN REVIEW. PLEASE NOTE THAT RESPONSES WERE | | | SUBMITTED FOR OTHER TRADES. SOME OF THE PREVIOUS | | | COMMENTS WOULD REQUIRE AN EXPLANATION OR | | | CLARIFICATION. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2007-10-22 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2007-10-22 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2007-10-22 15:25:52 | 1. WRONG INSPECTIONS DEPARTMENT LISTED ON PAGE 1. LISTS | | | PALM BEACH COUNTY INSTEAD OF WEST PALM BEACH. | | | | | | 2. ANY INSTALLATION OF EQUIPMENT SHALL NOT INTERFERE | | | WITH ANY EXISTING FIRE SAFETY EQUIPMENT LOCATED ON THE | | | ROOF OR WITHIN THE BUILDING. | | | | | | 3. NO ROUTING OF ELECTRICAL CONDUITS OR PIPING SHALL | | | OCCUR WITHIN ANY REQUIRED STAIRWELL FOR THE BUILDING. | | | | | | 4. WHAT SYSTEMS WILL THE GENERATOR BE PROVIDING STANDBY | | | POWER FOR. IF ONLY USED FOR COMMUNICATION PURPOSES, IS | | | IT LEGALLY REQUIRED TO HAVE STANDBY FUEL SUPPLIES. | | | PLEASE PROVIDE MORE DETAILS. | | | | | | 5. PLEASE EXPLAIN INSTALLATION OF FUEL LINE THROUGH | | | EXISTING BALCONIES. | | | | | | 6. PLEASE PROVIDE ALL APPLICABLE LISTINGS FOR THE | | | GENERATOR. | | | | | | 7. NO PROPANE STORAGE TANKS ARE ALLOWED TO BE INSTALLED | | | ON THE ROOF. IF A SECONDARY FUEL SUPPLY IS NECESSARY IT | | | WILL NOT BE ALLOWED TO BE STORED ON THE ROOF. | | | | | | 8. A RISER DIAGRAM OF GAS PIPING SHOULD BE PROVIDED | | | ILLUSTRATING THE RUN OF PIPING IN RELATION TO BUILDING | | | ELEMENTS TO INCLUDE DOORS, WINDOWS, AND OTHER FEATURES | | | OF THE BUILDING. | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
N |
Date |
2007-11-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-11 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-11 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2007-11-11 10:09:57 | REVIEW #: 1ST | | | ACTION: NOT REQUIRED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | AT THIS TIME THE SCOPE OF WORK DOES NOT INDICATE | | | ON-SITE FUEL STORAGE. IF THIS SHOULD CHANGE WITH FUTURE | | | RESUBMITTAL, PLANS WILL BE REVIEWED FOR COMPLIANCE AT | | | THAT TIME. | | | NOTE: FUEL STORAGE, PIPING AND REFUELING SYSTEMS FOR | | | STATIONARY COMBUSTION ENGINES SHALL COMPLY WITH NFPA | | | 37-02 AND NFPA 30-00 IN ACCORDANCE WITH FBC,M SECTION | | | 915. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-17 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-17 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-06-05 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-06-05 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2008-06-05 09:36:15 | DENIED; | | | | | | (ONE COPY OF OLD PLANS WAS NOT SUBMITED) | | | OLD COMMENTS 1 AND 2, OK | | | NEW COMMENTS; | | | 1.TYPE OF GAS PIPE USED? I.E. BLACK IRON, GALV. ETC. | | | PLEASE LIST ON PLAN. | | | 2.SIZE ALL PIPE. | | | 3. PAGE 3 OF 3 " DESIGN PARAMETER" SHOWS INLET PRESSURE | | | AT 14 "WC, USING FBC FUEL GAS CODE TABLE 402.4(5) PIPE | | | WOULD BE 2 1/2". | | | 4. A REGULATOR IS CALLED FOR AT GENERATOR, AT 1/2 LB | | | REGULATOR IS NOT REQUIRED. IF PRESSURE IS CHANGED | | | SUBMIT MANUFACTURE AND MOLEL NUMBER OF REGULATOR TO BE | | | USED. THE SHUTOFF VALVE SHOWN ON ISOMETRIC AT GENERATOR | | | SHOULD BE UP STREAM OF REGULATOR AND A UNION IS | | | REQUIRED BEFORE GENERATOR. | | | 5. TYPE OF GAS USED NATURAL OR L.P. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-21 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-21 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2007-11-21 09:17:53 | DENIED; | | | 1.SHOW THE PIPE SUPPORT SPACING PERFBC FUELGAS | | | TABLE 415. | | | 2. ADD NOTE TO GAS PIPING PAGES, " METALLIC PIPING AND | | | FITTINGS COATED WITH A CORROSION-RESISTANT MATERIAL | | | SHALL BE USED ". SEE SECTION 403.8. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-12 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-12 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2009-03-12 11:47:27 | TO "COMM" BD#24 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-19 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-19 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2008-05-19 14:56:18 | TO "COMM" BD#39 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-21 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-24 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2007-10-12 16:52:23 | TO "COMM" BD#7 | | 2007-09-24 08:22:38 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-30 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-30 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2009-03-30 15:11:11 | GAS GENERATOR. NO FURTHER MECHANICAL REVIEW REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-16 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-16 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2008-06-16 10:50:16 | PREVIOUS COMMENTS ADDRESSED. PLANS WILL NOT BE STAMPED | | | FOR MECHANICAL COMPLIANCE AS THIS IS A GAS APPLIANCE | | | AND SUBJECT TO GAS REVIEW BY THE PLUMBING PLAN | | | REVIEWER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-11-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-11 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-11 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2007-11-11 11:32:12 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PLEASE SHOW THE LOCATION OF ALL OUTSIDE AIR INTAKES, | | | GRAVITY VENTS AND OPENINGS INTO THE BUILDING AND THEIR | | | RELATED DISTANCE TO THE GENERATOR EXHAUST TO SHOW | | | COMPLIANCE WITH FBC,M 401.5.1 AND FBC,M 501.2. | | | | | | 2. THE AIR SUPPLY FOR THE ENGINE SHALL BE DESIGNED TO | | | MEET AT LEAST THE MINIMUM REQUIREMENTS FOR COMBUSTION, | | | COOLING, AND VENTILATION, AND TO PREVENT FLUE GAS | | | PRODUCTS FROM BEING DRAWN FROM STACKS OR FLUES OF | | | BOILERS OR OTHER COMBUSTION DEVICES. SHOW THE LOCATION | | | OF ANY VENTS OR STACKS ON THE ROOF AND THEIR DISTANCES | | | FROM THE COMBUSTION/VENTILATION AIR INTAKES FOR THE | | | GENERATOR IN ACCORDANCE WITH NFPA 37-02 SEC 4.1.1.2. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-21 |
Time |
09:19 |
Rev Time |
|
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
X |
PERMIT EXTENSION |
| Rev No |
1 |
Status |
N |
Date |
2009-02-12 |
|
|
Cont ID |
|
| Sent By |
dfulcher |
Date |
2009-02-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
dfulcher |
Date |
2009-02-12 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2009-02-12 14:13:30 | EXTEND PERMIT APP TO 3/30/09 PER RREGUEIRO - DRF |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-03-17 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-03-17 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2009-03-17 11:11:59 | PROPOSED GENERATOR DOES NOT EXCEED HEIGHT OF EXISTING | | | ROOFTOP EQUIPMENT NOR IS IT VISIBLE FROM THE GROUND. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-05-21 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-05-21 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2008-05-21 14:11:54 | ***APPROVED - RESUB #1*** | | | | | | *THE PROPOSED EQUIPMENT IS NOT HIGHER THAN THE EXISTING | | | EQUIPMENT ON THE ROOF AND CANNOT BE SEEN FROM GROUND. | | | | | | | | | | | | | | | | | | SENT TO COMM. BOARD #39 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-18 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-18 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2007-10-18 13:14:48 | ***FAILED*** | | | | | | | | | 1)PURSUANT TO SECTION 94-216(D)(9) OF THE CITY OF | | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS:MECHANICAL SYSTEMS, BACKFLOW PREVENTERS, | | | TELEVISION ANTENNAS, SATELLITE DISHES AND COMMUNICATION | | | DEVICES SHALL BE SCREENED FROM VIEW BY LANDSCAPING OR | | | BUILT ELEMENTS DESIGNED AS AN INTEGRAL PART OF THE | | | BUILDING ARCHITECTURE. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|