Plan Review Details - Permit 07090594
Plan Review Stops For Permit 07090594
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-04 Cont ID  
Sent By mperson Date 2007-10-04 Time 11:27 Rev Time 0.00
Received By mperson Date 2007-09-20 Time 16:20 Sent To  
Notes
2007-09-20 16:20:39TO "P" BOX

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-10-04 Cont ID  
Sent By mperson Date 2007-10-04 Time 10:28 Rev Time 0.00
Received By mperson Date 2007-10-04 Time 10:28 Sent To PC
Notes
2007-10-04 11:22:13DENIED
 REFERENCE:
 ** FBC-2004 WITH 05 &06 REVISIONS, PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. NOTE: THE CONTRACTOR LICENSE NUMBER IS INCORRECT ON
 THE PERMIT APPLICATION. PLEASE REFERENCE THE DBPR
 ONLINE SERVICES SEARCH INDICATING THE CORRECT LICENSE
 NUMBER ATTACHED TO THE DENIED COMMENTS. ALSO THE
 CONTRACTOR PHONE NUMBER HAS BEEN CROSSED OUT WHICH IS
 THE CONTACT NUMBER. PLEASE CORRECT THE PERMIT
 APPLICATION ON THE RESUBMITTAL.
  
 2. THE SUBMITTED PROPOSED IRRIGATION DRAWINGS ARE ON
 COPIES OF ORIGINAL SIGNED AND SEALED SHEET NO. L1, BY
 LANDSCAPE ARCHITECT DAVID L CARPENTER & ASSOCIATES,
 INC.
 NOTE: ANY REVISIONS TO SHEET NO. L1 ARE TO BE BY THE
 ORIGINAL DESIGN PROFESSIONAL PER THE FOLLOWING, IF THE
 DESIGN PROFESSIONAL IS A
 LANDSCAPE ARCHITECT REGESTERED UNDER THE
 LAWS OF THIS STATE REGULATING THE
 PRACTICE OF LANDSCAPE ARCHITECTURE AS
 PROVIDED FOR IN CHAPTER 481, FLORIDA
 STATUTES, PART LL, THEN HE OR SHE SHALL
 AFFIX HIS OR HER SEAL, SIGNATURE AND
 DATE TO SAID DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA AS DEFINED IN
 SECTION 481.303(6)(A)(B)(C)(D),FS.
  
 **CONTRACTOR CAN SUBMIT HIS/HER ORIGINAL DESIGN PLANS
 AS LONG AS PER FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 3. PROVIDE A LEGEND WITH SYMBOLS INDICATING ALL
 EQUIPMENT (PIPE MATERIAL, SPRINKLER HEADS, BACKFLOW
 PREVENTER, CONTROL BOX W/RAIN SENSOR). SIZE ALL PIPING
 AND INDICATE SPRINKLER HEAD LOCATIONS PER 106.1.1
 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 4. INDICATE PIPE SLEEVE LOCATIONS WHERE IRRIGATION
 PIPING IS CROSSING PAVED PARKING AREAS PER FBC-2004
 W/05 & 06 REV. SEC. 305.3 STRESS AND STRAIN.
  
 5. PLEASE INDICATE IF THE BACKFLOW PREVENTER FOR THE
 PROPOSED IRRIGATION SYSTEM IS NEW OR EXISTING ON THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved