| Plan Review Stops For Permit 07090501 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-11-21 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-11-21 |
Time |
17:31 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-08 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-10-08 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-10-08 |
Time |
17:43 |
Sent To |
PC |
|
| Notes |
| 2007-10-08 17:44:27 | | | | | | | DENIED | | | | | | 1)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. | | | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. | | | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE | | | DENIED. ****PLEASE SEE ONE COPY OF ATTACHED COVER | | | SHEETS FOR STORM PANELS AND SINGLE HUNG WINDOWS**** | | | | | | 2)PRODUCT APPROVALS ARE REQUIRED FOR PGT MULLIONS | | | (FL# 261-R3) WHERE TWO OR MORE WINDOW UNITS ARE | | | ATTACHED TOGETHER | | | | | | 3)THE NOA FOR THE EXTERIOR DOORS WAS SUBMITTED WITH | | | THE INCORRECT DRAWINGS THAT BELONG TO IT PLEASE NOTE | | | THAT THE MIAMI-DADE REPORT IS FOR GLAZED DOORS AND THEY | | | HAVE NO IMPACT RATING AND WOULD THEREFORE REQUIRE | | | SHUTTERS. THE FLORIDA STATEWIDE PRODUCT APPROVAL # FOR | | | JELD WEN O/S STEEL DOORS WITH WOOD EDGES IS (FL# | | | 539-R3) AND THE MIAMI-DADE REPORT # 02-0712.06 | | | | | | 4)THE MIAMI-DADE REPORT FOR THE STORM PANELS HAS ALSO | | | BEEN REVISED SEE THE ATTACHED UPDATED REPORT, PLEASE | | | NOTE THAT THE ANCHOR SPACINGS ARE THE SAME. | | | | | | 5)SHUTTER SPANS ON THE INSTALLATION SCHEDULE ARE | | | INCORRECT SPAN = OPENING HEIGHT (IF APPLIED VERTICALLY) | | | PLUS 2 X E.D. (7") EG. OPENING # 1 | | | 4'-0' + 7" SPAN = 4'-7" OR 55" | | | | | | 6)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | PLEASE MAKE CORRECTIONS TO PRODUCT APPROVALS AND | | | SHUTTER INSTALLATION SCHEDULE AND RESUBMIT | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-02 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-02 |
Time |
12:54 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-26 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-26 |
Time |
13:47 |
Sent To |
M |
|
| Notes |
| 2007-09-26 15:36:17 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING | | | CODE, 2005 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC | | | AS | | | AMENDED, CHAPTER 1, AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | | FS, RESPECTIVELY. | | | THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL | | | IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES, | | | IF EXEMPTIONS APPLY. | | | | | | 2} 301.5 FBC EXISTING BUILDING CODE. THE DESIGN | | | PROFESSIONAL OR OWNER MUST ELECT THE LEVEL OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF THE | | | EXISTING BUILDING CODE. DECLARE SAME ON THE PLAN. | | | | | | 3} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. | | | | | | 4} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1 | | | RESIDENTIAL FLORIDA BUILDING CODE. LOCATE ON THE PLAN | | | TO INDICATE COMPLIANCE. | | | | | | 5} REGARDING THE AHU IN THE BATHROOM PER 240.24(E) IN | | | DWELLING UNITS AND GUEST ROOMS OR GUEST SUITES OF | | | HOTELS AND MOTELS, OVERCURRENT DEVICES, OTHER THAN | | | SUPPLEMENTARY OVERCURRENT PROTECTION, SHALL NOT BE | | | LOCATED IN BATHROOMS. | | | | | | 6} LOCATE THE CONDENSING UNIT ON THE PLAN. ALSO SHOW | | | COMPLIANCE WITH THE REQUIRED DISCONNECT PER 440.14, | | | RECEPTACLE PER 210.63. ALSO NOTE ZONING WILL NEED TO | | | SEE THE LOCATION FOR SETBACK REQUIREMENTS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-21 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-21 |
Time |
16:48 |
Sent To |
M |
|
| Notes |
| 2008-03-21 16:48:23 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-21 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-21 |
Time |
16:31 |
Sent To |
M |
|
| Notes |
| 2007-12-21 16:31:48 | SENT TO TOM GORDON'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-06 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-06 |
Time |
11:21 |
Sent To |
Z |
|
| Notes |
| 2007-12-06 11:21:52 | TO "CHOOPS" DESK/RESUB--EXPEDITED-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-29 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-29 |
Time |
16:52 |
Sent To |
E |
|
| Notes |
| 2007-11-28 11:22:02 | | | | ***EXPEDITED REVIEW. WPB HCD HOUSING*** | | | ***REHAB PROGRAM. 11/28/07. RB *** | | 2007-10-29 16:53:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-10-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-19 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2007-09-19 09:28:40 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-24 |
Time |
11:46 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-24 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2008-03-24 11:47:00 | REVISION TO MECH. PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-28 |
Time |
13:35 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-12-28 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-07 |
Time |
08:26 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-12-07 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2007-12-07 08:32:21 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE THREE TON A/C SYSTEM IS TO LARGE. COOLING LOAD | | | CALCULATIONS ARE CALLING FOR 25,086 TOTAL COOLING | | | BTU'S. MECHANICAL PLANS ARE SHOWING 33,600 TOTAL | | | COOLING BTU'S. THE PLANS CAN ONLY CALL FOR 15% MORE | | | BTU'S. THAN THE COOLING LOAD CAL'S., SEE 2004 FBC | | | 13-607.1.ABC.1.1. A 2.5 TON SYSTEM MAY MEET YOUR NEEDS, | | | SEE ATTACHED ARI CERTIFICATE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-02 |
Time |
15:37 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-02 |
Time |
15:37 |
Sent To |
P |
|
| Notes |
| 2007-11-02 15:48:09 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) COOLING LOAD CALCULATION ARE SHOWING THE UNDER AIR | | | AREA AS 918 SQUARE FEET AND THE CEILING HEIGHT AS 10 | | | FEET, THE BUILDING PLANS STATE THE UNDER AIR AREA AS | | | 828 SQUARE FEET AND THE CEILING HEIGHT AS 8 FOOT 4 | | | INCHES. PLEASE CORRECT THE COOLING LOAD CALCULATIONS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-27 |
Time |
11:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-09-27 |
Time |
11:15 |
Sent To |
P |
|
| Notes |
| 2007-09-27 11:30:10 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, SEE | | | FBC 13-600.3.A. OR YOU MAY SUBMIT FORM 600C-04R, SEE | | | 2004 FBC 13-101.2.3. | | | | | | 2) ENERGY CALCULATIONS LINE #1 SHOWS CONSTRUCTION AS | | | ADDITION, PLEASE CORRECT TO EXISTING OR RENOVATION, SEE | | | FBC 13-600.3.ABC.2. | | | | | | 3) ENERGY CALCULATIONS LINE 11A SHOWS THE SUPPLY AIR | | | DUCTS ARE IN A CONDITIONED SPACE, MECHANICAL PLANS SHOW | | | THE SUPPLY AIR DUCTS TO BE IN ATTIC, PLEASE CORRECT | | | ENERGY CAL'S. | | | | | | 4) COOLING LOAD CALCULATIONS (MANUAL J) ARE CALLING FOR | | | 25,559 TOTAL BTU'S, THE A/C SYSTEM BEING INSTALLED ON | | | THE MECHANICAL PLAN IS 33,600 TOTAL BTU'S. THE PLANS | | | CAN ONLY CALL FOR 15% MORE TOTAL BTU'S THAN THE COOLING | | | LOAD CAL'S, SEE FBC 13-607.1.ABC.1.1. (SEE ATTACHED ARI | | | LISTING, PERHAPS A 2.5 TON SYSTEM WOULD MEET THE | | | REQUIREMENTS). PLEASE CORRECT. | | | | | | 5) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN, AND | | | CONTRACTOR INFORMATION IF APPLICABLE ON THEM, SEE | | | W.P.B. AMEND. 106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-17 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-17 |
Time |
13:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-03 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-03 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
| 2007-10-03 10:49:27 | DENIED; | | | ALL INFORMATION/DRAWINGS/SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPON- | | | SIBLE FOR THE DESIGN. SECTION 104.2.1 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-12-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-06 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-06 |
Time |
12:11 |
Sent To |
M |
|
| Notes |
| 2007-12-06 12:12:05 | ***APPROVED - RESUB #2 - (ZONING 2ND REVIEW)*** | | | | | | | | | | | | SENT TO "M" - TG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-02 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-02 |
Time |
14:05 |
Sent To |
M |
|
| Notes |
| 2007-11-02 14:08:03 | ***FAILED - RESUB #1 (ZONING 1ST REVIEW)*** | | | | | | | | | 1)PLEASE PROVIDE TWO COPIES OF A CURRENT SURVEY | | | SHOWING THE LOCATION OF THE PROPOSED A/C UNIT WITH | | | SETBACK DIMENSIONS TO ALL PROPERTY LINES.NOTE: | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4' INTO | | | A REQUIRED SETBACK. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|