| Plan Review Stops For Permit 07090490 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-20 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-20 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-13 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-13 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-02 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-02 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2008-04-02 17:47:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.SHEET 1216F-SC-001, DESIGN CRITERIA, NOTE THE | | | FOLLOWING: | | | | | | A.THE CORRECT ASCE REFERENCE IS 7-02, FBC CHAPTER 35 | | | (ASCE7-05 SHOWN ON THE PLAN). | | | | | | B.FROM THE SURVEY, THIS APPEARS TO BE EXPOSURE C. | | | EITHER REVISE THE EXPOSURE CLASSIFICATION AND ANCHORING | | | IF REQUIRED OR CLARIFY EXPOSURE B CLASSIFICATION. | | | PLEASE NOTE THAT THE DEFINITION FOR EXPOSURE C HAS | | | CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-16 |
Time |
13:29 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-10-16 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2007-10-16 13:32:08 | BUILDING PLAN REVIEW | | | PERMIT: 07090490 | | | ADD: 7501 N JOG RD | | | CONT: DALE ROSSMAN | | | TEL: (561)262-9566 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. | | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE2007 REVISIONS. | | | | | | 2) 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING INFORMATION | | | RELATED TO WIND SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-30 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-30 |
Time |
16:39 |
Sent To |
FUEL |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-29 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-29 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2008-07-29 13:05:28 | ** TEMPORARY DENIEDREVIEW ** | | | | | | | | | 1) NOTE:PLANS WERE PLACED INTO TWO COMPLETE SETS WITH | | | SHEETS ATTACHED AS REQUESTED ON PREVIOUS REVIEW BY THIS | | | REVIEWER. | | | PLEASE KNOW THE SPEC/CUT SHEETS FOR THE GENERATOR WERE | | | NOT IN PACKAGE RESUBMITTED ONLY THE BILLING SHEET. | | | PLEASE SUBMIT. | | | THIS CAN BE COORDINATED TO BE BROUGHT IN AS SOON AS | | | POSSIBLE. CALLED AND SPOKE TO JOHN BELL. WILL CALL | | | BACK. | | | | | | ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-06-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-13 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-13 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2008-06-13 16:16:52 | ** DENIED ** | | | | | | 1) NOTE: PLEASE SEE COMMENT WITH RESPECT TO GROUND | | | FAULT ON ELECTRICAL SERVICE ALONG WITH GROUND FAULT | | | SENSING IS STILL A COMMENT. AS STATED ON PREVIOUS | | | REVIEWS ALL MANUFACTURES WHITE PAPERS AND DOCUMENTS | | | READ BY THIS REVIEWER INDICATE A COORDINATION LOSS | | | BETWEEN THE MAIN, ATS AND SYSTEM WHEN A FOUR POLE UNIT | | | IS NOT INSTALLED. | | | PLEASE PROVIDE DOCUMENTATION FROM THE PROPOSED | | | MANUFACTURE ASCO WHICH SHOWS AND STATES THIS IS NO | | | LONGER AN ISSUE OR IS NOT AN ISSUE FOR THE GROUND FAULT | | | PROTECTION ON PRIMARY AND GROUND FAULT SENSING ON THE | | | GENERATOR AND SECONDARY SIDE OF EQUIPMENT. | | | 110.3, 90.7, 240.13, 230.95, 700.26, 700.7D, 701.17, | | | NFPA-110 6.2.15. | | | THE RESPONSE LETTER MENTIONS THIS SYSTEM DOES NOT | | | AFFECT OTHER EMERGENCY POWER IN THE BUILDING. WHAT ARE | | | THE OTHER EMERGENCY POWER SOURCES FOR BACK UP OF | | | EMERGENCY AND LEGALLY REQUIRED SYSTEM? | | | THE RESPONSE MENTIONS THAT THE NEUTRAL AND GROUND BOND | | | TO BE REMOVED AT THE GENERATOR AS WELL AS THIS WAS | | | NOTED ON PLANS. | | | THIS WAS NOT MY PREVIOUS COMMENT. IF A FOUR POLE | | | TRANSFER SWITCH IS REQUIRED TO PROVIDE COORDINATION, | | | THEN THE GENERATOR WOULD BE REQUIRED TO BE SEPARATELY | | | DERIVED. | | | | | | 2) NOTE: PLEASE BE SURE TO PLACE ALL PLANS INTO AN | | | ATTACHED ORDERLY FASHION. NEW SHEETS SHOULD BE SEPARATE | | | INTO TWO SETS WITH OLD SHEETS ATTACHED TO EACH OTHER | | | SEPARATELY. | | | | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-05 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-05 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2008-03-05 12:54:17 | ** DENIED2ND REVIEW ** | | | | | | ** IMPORTANT: AS NOTED ON PREVIOUS REVIEW THERE WERE | | | SEVERAL ITEMS NOT SUBMITTED FOR INITIAL REVIEW AND THAT | | | THAT MANY OF THESE ITEMS ARE ONLY NOW BEING SUBMITTED | | | FOR THE FIRST TIME THERE ARE SEVERAL NEW COMMENTS. | | | ** PLEASE ALSO BE AWARE AS THERE ARE STILL SOME ITEMS | | | NOT SUBMITTED OR WILL BE CHANGING BASED ON COMMENTS | | | BELOW A FULL REVIEW FOR CODE COMPLIANCE MAY NOT BE DONE | | | AT THIS TIME. | | | | | | 1) NOTE: PLEASE SEE FBC CHAPTER 27 WHICH STATES ALL | | | BACK POWER GENERATOR POWER TO BE DONE PER NFPA-110. | | | THIS DOES NOT STATE WITH THE EXCEPTION TO OPTIONAL | | | STAND-BY SYSTEMS. | | | | | | 2) NOTE: PLEASE SEE THE RISER NOW SHOWS GROUND FAULT | | | PROTECTION ON THE GENERATOR. PLEASE SEE THE PREVIOUS | | | REVIEW COMMENT WAS WITH RESPECT TO THE REQUIRED GFP ON | | | THE PRIMARY SIDE THE SERVICE. PLEASE SEE 230.95 AND | | | 240.13 WHICH DOES NOT REQUIRE THIS GFP ON THE SECONDARY | | | EMERGENCY SIDE. PLEASE SEE 700 AND 701 DOES REFLECT THE | | | DESIRE FOR GROUND FAULT SENSING. PLEASE SEE WHITE | | | PAPERS FOR SEVERAL MANUFACTURES WITH RESPECT TO | | | COORDINATION OF THE GFP OF SYSTEMS. THIS OFFICE HAS | | | FOUND FROM ALL MANUFACTURES REVIEWED TO DATE SPEAK OF | | | COORDINATION LOSS WHEN THE USE OF A 4-POLEIS NOT | | | INSTALLED. | | | ** PLEASE BE AWARE USING THE 4-POLE UNIT WOULD REQUIRE | | | A SEPARATELY DERIVED GENERATOR SYSTEM. | | | | | | A) PLEASE SEE THE PLANS CLEARLY SHOW THE NEW PROPOSED | | | ATS LOCATED OUTSIDE YET THE BILLING AND ORDER FORMS | | | CLEARLY SHOW THE ATS AS NEMA 1 RATED WHICH IS ONLY FOR | | | INDOOR INSTALLATIONS.110.9, 90.7 | | | PLEASE SEE THAT NO INFORMATION COULD BE LOCATED TO SHOW | | | THE ATS IS *SERVICE ENTRANCE RATED*. RATING OF SERVICE | | | EQUIPMENT AND WHETHER OR NOT IT CONTAINS A *MANUAL | | | MEANS OF DISCONNECT, RATED FOR THE LOAD SERVED* | | | (230.76, 230.79). | | | | | | B) PLEASE SEE THE PLANS INDICATE THE ATS AS 1600AMPS | | | AND RISER INDICATES THE ATS AS 2000AMPS, AND YET THE | | | BILLING ORDER SHEETS INDICATE 1200AMPS? | | | PLEASE COORDINATE. | | | | | | 110.3, 90.7 ETC | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 2) NOTE: PLEASE SEE THE CONDUIT DUCT BANK DETAILS WHICH | | | DOES NOT INDICATE ALL CONDUITS IN FACT THE DETAIL | | | MENTIONS TYPICAL OF THREE YETBASED ON THE RISER THE | | | THERE ARE DUCK BANKS WITH 6 AND 4 SETS. | | | PLEASE COORDINATE AND CLARIFY THESE. | | | FBC 106.1.2 FOR COORDINATION. | | | | | | 3) NOTE: PLEASE CLARIFY WHAT THE 1/C IS IN EACH OF THE | | | CONDUIT/CONDUCTORS NOTES. | | | FBC 106.1.2 ADDITIONAL INFORMATION. | | | | | | 4) NOTE: PLEASE SUBMIT LOAD CALCULATIONS AND INTENDED | | | LOADS FOR THE SERVICE. PLEASE SEE 702.5 AS THE | | | EQUIPMENT NEEDS TO BE RATED FOR THE LOADS TO BE SERVED. | | | AS THE SERVICE IS 2000AMPS AND THE BREAKER ON THE | | | GENERATOR IS ONLY 1000AMPS. | | | PLEASE SUBMIT LOADS. | | | 220.87 | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-14 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-14 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2007-10-14 13:49:27 | ** DENIED** | | | | | | 1) NOTE: PLEASE SUBMIT TWO SETS OF PLANS. PLEASE DO NOT | | | SUBMIT INDIVIDUAL LOOSE SHEETS NOT IN SETS FOR REVIEW. | | | ONE SET WAS MADE FOR REVIEW OF PLANS BY THIS REVIEWER. | | | PLEASE BE SURE TO DO THIS UPON THE NEXT RE-SUBMITTAL OF | | | PLANS. | | | FBC ADMIN SECTION 106.1 | | | | | | 2) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS | | | WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES | | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-110 ( FBC CHAPTER 27 REFERENCED. | | | | | | 3) NOTE: PLEASE SEE COLOR CODING IS REQUIRED TO BE | | | BROWN, PURPLE AND YELLOW. | | | THE NEC DOES NOT PROVIDE COLOR CODING AND *ORANGE* IS | | | BASED ON A HIGH-LEG SYSTEM WHICH THIS IS NOT. THE | | | CURRENT COLOR CODING IN THIS JURISDICTION FOR THE PAST | | | 20+ YEARS IS THAT AS BR/PURP/YELL. | | | 90.4 | | | | | | 4) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR BOTH THE GENERATOR AND ATS BEING PROPOSED. | | | PLEASE SEE COMMENTS BELOW AS THERE ARE SEVERAL ITEMS TO | | | BE REVIEWED FOR CODE COMPLIANCE WHICH CAN NOT BE DONE | | | AT THIS TIME. | | | PLEASE BE SURE THE SPECS/CUT SHEETS FOR ANY FUEL TANK | | | FOR PRIME-MOVER ARE SUBMITTED ALSO. THIS WILL BE | | | REVIEWED BY OTHER TRADES SUCH AS MECHANICAL, FIRE | | | MARSHAL ETC. | | | NEC 90.7, 110.3 ETC | | | | | | 5) NOTE: PLEASE SEE 240.13 AND 230.95 AS GF PROTECTION | | | COULD NOT BE LOCATED. | | | PLEASE ALSO SEE SPECIFICATIONS FROM MANUFACTURES AS | | | THIS MAY REQUIRE THIS TO BE A 4-POLE DEVICE WHICH THE | | | GENERATOR WOULD THEN BECOME AND SEPARATELY DERIVED | | | SYSTEM. | | | PLEASE SUBMIT. | | | | | | 6) NOTE: PLEASE SEE MISSING DISCONNECT FOR FEEDERS FROM | | | THE GENERATOR TO MEET 225.31-225.39. | | | PLEASE KNOW AS ZONING WILL REQUIRE AN ENCLOSURE AROUND | | | THE UNIT AND THE GENERATOR BREAKER MAY NOT BE USED TO | | | MEET 702.11AS THIS WILL BE ENCLOSED, ETC, PLEASE | | | PROVIDE DISCONNECT. | | | PLEASE SEE COMMENT ABOVE WITH RESPECT TO THE TYPE OF | | | ATS. THIS NEED ONLY BE A DISCONNECTING MEANS AND DOES | | | NOT REQUIRE OVER CURRENT PROTECTION. | | | | | | 7) NOTE: PLEASE SEE NOTE ON SHEET EE-001WHICH MENTIONS | | | OWNER MAY CHOOSE LOADS MANUALLY PER 702.5, HOWEVER THE | | | SYSTEM AS SUBMITTED IS AN AUTOMATED SYSTEM. | | | PLEASE CLARIFY. | | | | | | THE LIFE SAFETY CODE ALONG WITH STATUTES ETC REQUIRED | | | EMERGENCY AND LEGALLY REQUIRED SYSTEMS. IT IS WITH | | | RESPECT TO SECTION 702 FOR OPTIONAL STAND-BY SYSTEMS, | | | THE CODES ETC DO NOT REQUIRE ANY SUCH SPECIFIC LOADS | | | AND THE LOADS FOR AN OSS MAY BE CHOSEN BY OWNER. AS THE | | | PLANS SHOW A COMPLETE AUTOMATED SYSTEM, THIS UNIT SHALL | | | MEET ALL LOADS AS DETERMINED BY LOAD CALCULATIONS OR | | | BUILDING READINGS AS STATED. NO MANUAL SYSTEM WAS SHOWN | | | ON PLANS. | | | PLEASE PROVIDE MORE DETAILS ON LOADS WHICH WERE | | | GENERATED BY READINGS. | | | | | | 8) NOTE: PLEASE CLARIFY THE 60AMP CIRCUIT WHICH IS | | | SHOWN ON RISER BEING FED FROM A *OWNER APPROVED | | | PANEL*??? | | | THIS FEED ON THE SHEET E4-002 APPEARS THIS IS COMING | | | FROM ANOTHER SERVICE/LOCATION. | | | AS SYSTEM TO SINGLE UNIT EQUIPMENT MAY NOT BE MIXED | | | FROM DIFFERENT SERVICES, UNTIL CLARIFICATION IS MADE NO | | | REVIEW FOR THIS ITEM CAN BE CONFIRMED. | | | PLEASE ALSO INDICATE WHAT THIS CIRCUIT IS FOR? | | | PLEASE PROVIDE LOADS, ETC. | | | FBC 106.1.2 | | | | | | ** PLEASE KNOW AS NOT ALL INFORMATION WAS SUBMITTED FOR | | | REVIEW AND DUE TO COMMENTS ABOVE, THERE MAY VERY WELL | | | BE NEW COMMENTS ON THE FOLLOWING REVIEW. | | | NOTES CAN ONLY BE GIVEN BASED ON PLANS/DOCUMENTS | | | SUBMITTED. | | | | | | | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-14 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-14 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2008-08-14 14:48:29 | *****APPROVED***** | | | | | | PLAN SHEET 1216F-E4-002 (PREVIOUSLY APPROVED ON | | | 6/16/08) WAS STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-16 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-16 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2008-06-16 14:01:55 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;PLAN SHEET 1216F-E4-002 STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-04 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-04 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2008-04-04 12:14:23 | *****DENIED***** | | | | | | THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 1. OK | | | | | | 2.OK | | | | | | 3.WHAT SIZE AND WHAT LISTINGS ARE PRESENT FOR THE | | | DIESEL TANK? | | | | | | 4.PLEASE INDICATE WHAT EQUIPMENT THE NEW GENERATOR | | | WILL SUPPLY.IS ANY EMERGENCY EQUIPMENTBEING | | | SUPPLIED POWER FROM THIS EQUIPMENT. | | | | | | 5.OK | | | | | | 6.NO INFORMATION PROVIDED REGARDING ANY WARNING | | | LABELS OR SIGNAGE RELATING TO THE DIESEL TANK | | | INSTALLATION. | | | | | | 7.NO INFORMATION PROVIDED WITH REGARDS TO THE VENTING | | | OF THE DIESEL TANK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2007-10-22 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2007-10-22 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2007-10-22 10:21:25 | 1. THE ENTIRE INSTALLATION TO COMPLY WITH NFPA 70, THE | | | NATIONAL ELECTRICAL CODE. | | | | | | 2. NO CUT SHEETS OR PRODUCT APPROVALS PROVIDED WITH | | | PERMIT APPLICATION. | | | | | | 3. SEVERAL PLANS DECLARES THAT A DIESEL TANK IS | | | PROPOSED. WHAT SIZE AND WHAT LISTINGS ARE PRESENT FOR | | | THE TANK. | | | | | | 4. PLEASE INDICATE WHAT EQUIPMENT THE NEW GENERATOR | | | WILL SUPPLY. IS ANY EMERGENCY EQUIPMENT BEING SUPPLIED | | | POWER FROM THIS EQUIPMENT. | | | | | | 5. IS ANY DEVICES PLANNED TO PREVENT THE GENERATOR FROM | | | RECEIVING ANY MECHANICAL DAMAGE FROM PASSING VEHICLES. | | | | | | 6. NO INFORMATION PROVIDED REGARDING ANY WARNING LABELS | | | OR SIGNAGE RELATING TO THE DIESEL TANK INSTALLATION. | | | | | | 7. NO INFORMATION PROVIDED WITH REGARDS TO THE VENTING | | | OF THE DEIESEL TANK. | | | | | | 8. MORE DETAILS NEEDED TO PROVIDE A COMPLETE FIRE PLAN | | | REVIEW. | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
2 |
Status |
P |
Date |
2008-10-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-18 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-18 |
Time |
11:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
F |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-05 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-05 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2007-11-05 13:22:54 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | NO INFORMATION WAS PROVIDED FOR THE PROPOSED GENERATOR | | | OR MEANS OF FUEL STORAGE. PROVIDE MANUFACTURER'S SPECS | | | AND CUT SHEETS FOR THE GENERATOR AND THE FUEL TANK. | | | THIS APPLICATION CAN NOT BE REVIEWED AT THIS TIME. | | | | | | NOTE: UNDERGROUND FUEL TANKS >110 GALLONS AND ABOVE | | | GROUND FUEL TANKS >550 GALLONS REQUIRE PRIOR APPROVAL | | | BY PALM BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL | | | RESOURCE MANAGEMENT. FOR ADDITIONAL INFORMATION PLEASE | | | CONTACT PBC DERM AT 561-233-2400 OR VISIT THEM AT: | | | HTTP://WWW.CO.PALM-BEACH.FL.US/ERM/INDEX.ASP | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-26 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-26 |
Time |
10:46 |
Sent To |
E |
|
| Notes |
| 2008-09-26 10:47:15 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-18 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-18 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2008-07-18 11:24:04 | TO "COMM" BD#46 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-20 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-20 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2008-05-22 13:25:07 | TO "COMM" BD#63 | | 2008-05-20 14:57:56 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-29 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-29 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2008-02-29 08:29:49 | TO "COMM" BD#42 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-05 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2007-10-09 15:20:08 | TO "COMM" BD#27 | | 2007-09-17 14:56:14 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-10-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-18 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-18 |
Time |
11:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-11 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-11 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2008-08-11 09:40:00 | SAME AS PREVIOUS REVIEW. PLANS WILL BE STAMPED AND FUEL | | | STOP WILL BE PASSED ONCE PLANS ARE STAMPED BY | | | ELECTRICAL REVIEWER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-16 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-16 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2008-06-16 11:04:29 | SAME AS PREVIOUS REVIEW. PLANS WILL BE STAMPED FOR CODE | | | COMPLIANCE ONCE ELECTRICAL REVIEW IS PASSED SINCE THE | | | SAME PAGES ARE AFFECTED FOR BOTH REVIEWS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-03-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-17 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-17 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2008-03-17 16:42:19 | REVIEW #: 2ND | | | ACTION: FAILED PENDING. | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | MECHANICAL REVIEW PASSED. PLANS WILL NOT BE STAMPED AT | | | THIS TIME PENDING SUCCESSFUL ELECTRICAL REVIEW AS | | | SEVERAL PAGES ARE LIKELY TO BE REPLACED DURING THIS | | | PROCESS. REVIEW WILL REMIAN IN FAIL STATUS UNTIL THAT | | | PART OF THE REVIEW PROCESS IS COMPLETE. NEW SHEETS MAY | | | REQUIRE AN ADDITIONAL MECHANICAL REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-05 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-05 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2007-11-05 13:22:03 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | NO INFORMATION WAS PROVIDED FOR THE PROPOSED GENERATOR | | | OR MEANS OF FUEL STORAGE. PROVIDE MANUFACTURER'S SPECS | | | AND CUT SHEETS FOR THE GENERATOR AND THE FUEL TANK. | | | THIS APPLICATION CAN NOT BE REVIEWED AT THIS TIME. | | | | | | NOTE: UNDERGROUND FUEL TANKS >110 GALLONS AND ABOVE | | | GROUND FUEL TANKS >550 GALLONS REQUIRE PRIOR APPROVAL | | | BY PALM BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL | | | RESOURCE MANAGEMENT. FOR ADDITIONAL INFORMATION PLEASE | | | CONTACT PBC DERM AT 561-233-2400 OR VISIT THEM AT: | | | HTTP://WWW.CO.PALM-BEACH.FL.US/ERM/INDEX.ASP | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-07-28 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-07-28 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2008-07-28 16:07:21 | PASSED W/PROVISO | | | | | | LANDSCAPE SHALL BE INSTALLED PER THE ATTACHED DIAGRAM. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-06-02 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-06-02 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2008-06-02 15:13:04 | PASSED W/PROVISO | | | | | | NEW LANDSCAPE SHALL BE INSTALLED PER THE DIAGRAM | | | ATTACHED TOTHE PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-03-03 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-03-03 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2008-03-03 16:35:28 | PASSED W/PROVISO | | | | | | REFER TO THE ATTACHED PLANTING DIAGRAM FOR LANDSCAPE | | | INSTALLATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-10-12 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-10-12 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2007-10-12 15:26:38 | FAILED | | | | | | 1) PROVIDE PHOTOS OF THE PROPOSED LOCATION. | | | | | | 2) PROVIDE THE HEIGHT OF THE PROPOSED GENERATOR. | | | | | | 3) AN OPAQUE FENCE/WALL AND LANDSCAPE HEDGE SHALL BE | | | PROVIDED AROUND THE GENERATOR PAD AS SCREENING.A | | | SEPARATE PERMIT WILL BE REQUIRED FOR THE FENCE/WALL. | | | LANDSCAPE MAY BE SHOWN WITH THESE PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|