 |
Plan Review Details - Permit 07090466
| Plan Review Stops For Permit 07090466 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-03-28 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-03-28 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-10 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-03-10 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2008-03-10 15:33:02 | | | | 1041 45TH ST 2ND REV.DOC | | | BUILDING PLAN REVIEW | | | PERMIT: 07090466 | | | ADD: 1041 45TH STREET | | | CONT: NEUTRON ELECTRIC | | | TEL: (561)201-5005 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 3RD 3-10-08 | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS, PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A | | | RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD | | | BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE | | | SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT | | | ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS WEST PALM | | | BEACH ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT APPLICATION (FIRST TIME | | | REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE | | | 2004 FBC BUILDING WITH THE 2007 REVISIONS. | | | | | | 2) 3RDREQUEST, MISSING INFORMATION ON PLAN IN REGARDS | | | TO WIND: 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE SHOWN ON THE | | | CONSTRUCTION DRAWINGS, 1)- BASIC WIND SPEED, MPH 2)- | | | WIND IMPORTANCE FACTOR, & BUILDING CATEGORY3)- WIND | | | EXPOSURE | | | | | | 3) 3RDREQUEST,2004 FBC 1609.1.3 PLEASE PROVIDE | | | INFORMATION ON THE ANCHORAGE THE GENERATOR TO RESIST | | | THE MOMENT OF OVERTURNING, UPLIFT AND SLIDING. | | | GENERATOR SLAB & ANCHOR REQUIREMENT PLEASE PROVIDE SIZE | | | OF GENERATOR(WXL),PLUS PROVIDE PLANS WITH THE | | | INFORMATION DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE THE DEVICE | | | REQUIRES WITHOUT LOAD REDUCTION. | | | | | | THE NEW SLAB AND HOLD DOWN DETAILS: 104.2.1* ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. PLEASE SEE ELECTRICAL | | | COMMENTS FOR ADDITIONAL INFORMATION REQUIRED FOR THE | | | DESIGNER. FL.S .S 481.229 (ARCHITECT) OR FL.S.S 471.003 | | | (ENGINEER). THIS AREA IS IN A FLOOD ZONE AH; THEREFORE | | | THE ELEVATION OF THE CONCRETE SHALL BE A MINIMUM OF | | | 17'6", WHICH SHALL BE STATED OF THE ENGINEERED PLANS. | | | ALL DIMENSIONS FOR THE CONCRETE SLAB SHALL BE INDICATED | | | ON THE DRAWINGS INCLUDING THE THICKNESS. INDICATE THE | | | CLEARANCE AROUND THE GENERATOR FOR MAINTENANCE AND | | | REPAIR WORK. | | | | | | **NOTE** IN ORDER TO PROVIDE CONFORMITY TO OUR RECORD | | | RETENTION PROGRAM 'NO WHITE-OUT OR HANDWRITING IN PEN | | | OR PENCIL' ON THE DRAWINGS OR REPORTS WILL BE | | | ACCEPTABLE. CLEARLY STATE IF THE GENERATOR IS USED FOR | | | LIFE SAFETY ISSUES. | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)805-6676 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-17 |
Time |
10:46 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-12-17 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2007-12-17 10:48:17 | BUILDING PLAN REVIEW | | | PERMIT: 07090466 | | | ADD: 1041 45TH STREET | | | CONT: NEUTRON ELECTRIC | | | TEL: (561)201-5005 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. | | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT APPLICATION (FIRST TIME | | | REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE | | | 2004 FBC BUILDING WITH THE2007 REVISIONS. | | | | | | 2) 2ND REQUEST, MISSING INFORMATION ON PLAN IN REGARDS | | | TO WIND: 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE SHOWN ON THE | | | CONSTRUCTION DRAWINGS, 1)- BASIC WIND SPEED, MPH 2)- | | | WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | | | | 3) 2ND REQUEST,2004 FBC 1609.1.3 PLEASE PROVIDE | | | INFORMATION ON THE ANCHORAGE THE GENERATOR TO RESIST | | | THE MOMENT OF OVERTURNING, UPLIFT AND SLIDING. | | | GENERATOR SLAB & ANCHOR REQUIREMENT PLEASE PROVIDE | | | SIZE OF GENERATOR(WXL),PLUS PROVIDE PLANS WITH THE | | | INFORMATION DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE THE DEVICE | | | REQUIRES WITHOUT LOAD REDUCTION. | | | | | | THE NEW SLAB AND HOLD DOWN DETAILS: 104.2.1* ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. PLEASE SEE ELECTRICAL | | | COMMENTS FOR ADDITIONAL INFORMATION REQUIRED FOR THE | | | DESIGNER. FL S S 481.229 (ARCHITECT)OR FL S S 471.003 | | | (ENGINEER). | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-20 |
Time |
09:21 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2007-10-20 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2007-10-20 09:47:03 | BUILDING PLAN REVIEW | | | PERMIT: 07090466 | | | ADD: 1041 45TH STREET | | | CONT: NEUTRON ELECTRIC | | | TEL: (561)201-5005 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. | | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1E) PLANS SUBMITTED FOR PERMIT APPLICATION (FIRST TIME | | | REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE | | | 2004 FBC BUILDING WITH THE2007 REVISIONS. | | | | | | 2) MISSING INFORMATION ON PLAN IN REGARDS TO WIND: 2004 | | | FL. BLD CODE 1603.1.4 THE FOLLOWING INFORMATION RELATED | | | TO WIND SHALL BE SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | | | | 3) 2004 FBC 1609.1.3 PLEASE PROVIDE INFORMATION ON THE | | | ANCHORAGE THE GENERATOR TO RESIST THE MOMENT OF | | | OVERTURNING, UPLIFT AND SLIDING. | | | GENERATOR SLAB & ANCHOR REQUIREMENT PLEASE PROVIDE | | | SIZE OF GENERATOR(WXL),PLUS PROVIDE PLANS WITH THE | | | INFORMATION DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE THE DEVICE | | | REQUIRES WITHOUT LOAD REDUCTION. | | | | | | THE NEW SLAB AND HOLD DOWN DETAILS: 104.2.1* ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. PLEASE SEE ELECTRICAL | | | COMMENTS FOR ADDITIONAL INFORMATION REQUIRED FOR THE | | | DESIGNER. FL S S 481.229 (ARCHITECT)OR FL S S 471.003 | | | (ENGINEER). | | | | | | | | | 4) PLEASE PROVIDE A SITE PLAN INDICA PROVIDE PLANS | | | ENOUGH TO VERIFY LOCATION OF GENERATOR VERSES BUILDING | | | OPENINGS WINDOWS, DOORS OR SOFFIT TYPE VENTS, ETC. | | | | | | MECHANICAL CODE | | | 804.3.4 HORIZONTAL TERMINATIONS. HORIZONTAL | | | TERMINATIONS SHALL COMPLY WITH THE FOLLOWING | | | REQUIREMENTS: | | | 1.WHERE LOCATED ADJACENT TO WALKWAYS, THE | | | TERMINATION OF MECHANICAL DRAFT SYSTEMS SHALL BE NOT | | | LESS THAN 7 FEET (2134 MM) ABOVE THE LEVEL OF THE | | | WALKWAY. | | | 2.VENTS SHALL TERMINATE AT LEAST 3 FEET (914 MM) | | | ABOVE ANY FORCED AIR INLET LOCATED WITHIN 10 FEET (3048 | | | MM). | | | 3.THE VENT SYSTEM SHALL TERMINATE AT LEAST 4 FEET | | | (1219 MM) BELOW, 4 FEET (1219 MM) HORIZONTALLY FROM OR | | | 1 FOOT | | | (305 MM) ABOVE ANY DOOR, WINDOW OR GRAVITY AIR INLET | | | INTO THE BUILDING. | | | 4.THE VENT TERMINATION POINT SHALL NOT BE LOCATED | | | CLOSER THAN 3 FEET (914 MM) TO AN INTERIOR CORNER | | | FORMED BY TWO | | | WALLS PERPENDICULAR TO EACH OTHER. | | | 5.THE VENT TERMINATION SHALL NOT BE MOUNTED | | | DIRECTLY ABOVE OR WITHIN 3 FEET (914 MM) HORIZONTALLY | | | FROM AN OIL TANK | | | VENT OR GAS METER. | | | 6.THE BOTTOM OF THE VENT TERMINATION SHALL BE | | | LOCATED AT LEAST 12 INCHES (305 MM) ABOVE FINISHED | | | GRADE. | | | | | | 804.3.5 VERTICAL TERMINATIONS. VERTICAL TERMINATIONS | | | SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: | | | 1.WHERE LOCATED ADJACENT TO WALKWAYS, THE | | | TERMINATION OF MECHANICAL DRAFT SYSTEMS SHALL BE NOT | | | LESS THAN 7 | | | FEET (2134 MM) ABOVE THE LEVEL OF THE WALKWAY. | | | 2.VENTS SHALL TERMINATE AT LEAST 3 FEET (914 MM) | | | ABOVE ANY FORCED AIR INLET LOCATED WITHIN 10 FEET (3048 | | | MM). | | | 3.WHERE THE VENT TERMINATION IS LOCATED BELOW AN | | | ADJACENT ROOF STRUCTURE, THE TERMINATION POINT SHALL BE | | | LOCATED AT LEAST 3 FEET (914 MM) FROM | | | SUCH STRUCTURE. | | | 4.THE VENT SHALL TERMINATE AT LEAST 4 FEET (1219 | | | MM) BELOW, 4 FEET (1219 MM) HORIZONTALLY FROM, OR 1 | | | FOOT (305 MM) ABOVE ANY DOOR, WINDOW OR GRAVITY AIR | | | INLET FOR THE BUILDING. 5.A VENT CAP SHALL BE | | | INSTALLED TO PREVENT RAIN FROM ENTERING THE VENT | | | SYSTEM. | | | 6.THE VENT TERMINATION SHALL BE LOCATED AT LEAST 3 | | | FEET (914 MM) HORIZONTALLY FROM ANY PORTION OF THE ROOF | | | STRUCTURE. | | | | | | 501.2 OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY | | | MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED OUTDOORS | | | AT A POINT WHERE IT WILL NOT CAUSE A NUISANCE AND FROM | | | WHICH IT CANNOT AGAIN BE READILY DRAWN IN BY A | | | VENTILATING SYSTEM. AIR SHALL NOT BE EXHAUSTED INTO AN | | | ATTIC OR CRAWL SPACE | | | | | | 401.5 OPENING LOCATION. | | | OUTDOOR AIR EXHAUST AND INTAKE OPENINGS SHALL BE | | | LOCATED A MINIMUM OF 10 FEET (3048 MM) FROM LOT LINES | | | OR BUILDINGS ON | | | THE SAME LOT. WHERE OPENINGS FRONT ON A STREET OR | | | PUBLIC WAY, THE DISTANCE SHALL BE MEASURED TO THE | | | CENTERLINE OF THE | | | STREET OR PUBLIC WAY. TING THE LOCATION OF THE | | | GENERATOR IN RELATIONSHIP TO OTHER STRUCTURES, PLEASE | | | NOTE IF THERE ARE STRUCTURES WITHIN 10'-0" OF THE | | | GENERATOR OPENINGS SUCH AS WINDOWS AND DOORS. | | | ADDITIONAL INFORMATION REQUIRED. POSSIBLE MECHANICAL | | | ISSUES. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-03-28 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-03-28 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2008-03-28 14:24:42 | ELEVATION CERTIFICATE PROVIDED , SITE MEETS AND EXCEEDS | | | FEMA REQUIREMENTS , OK TO APPROVE PER DEWEY.LM |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-04 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-04 |
Time |
18:37 |
Sent To |
PC |
|
| Notes |
| 2008-03-04 18:37:28 | | | | NO REVIEW TO BE DONE, CONTRACTOR IS BRINGING IN NEW | | | PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-03 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-03 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2007-12-03 13:57:03 | | | | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE MOST COMMENTS FROM PREVIOUS REVIEW | | | REMAIN. | | | | | | 1) NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS AND | | | DOCUMENTS ALL ATTACHED INTO EACH SET RESPECTIVELY. | | | PLEASE SEE ALL DOCUMENTS FOR EACH TRADE ARE DIVIDED AND | | | NOT IN SETS. | | | FBC 106.3.1, 106.1.2 | | | | | | 2) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW WHICH | | | MOST STILL REMAIN. | | | NEED TO KNOW THE OCCUPANCY OF PROJECT. | | | NEED PLANS SHOWING LOCATION(S) FOR ALL EQUIPMENT, | | | SERVICE EQUIPMENT ETC. | | | NEED TO SHOW ALL RELEVANT CODES. | | | NEED TO HAVE THE DESIGNER OF RECORD. | | | ETC. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE COPIED FROM PREVIOUS | | | REVIEW. | | | | | | ** DENIED** | | | | | | 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS | | | WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES | | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-110 ( FBC CHAPTER 27 REFERENCED. | | | | | | 2) NOTE: PLEASE SUBMIT LOADS ON THIS EXISTING/NEW | | | GENERATOR TO BE INSTALLED. | | | PLEASE PROVIDE INFORMATION IF THIS UNIT FEEDS ANY | | | EMERGENCY LIFE SAFETY SYSTEMS OR LEGALLY REQUIRED | | | SYSTEMS.700, 701, | | | PLEASE SEE 700.12B3, 701.11B3 AS ANY LIFE SAFETY, OR | | | LEGALLY REQUIRED SYSTEMS FED BY THIS UNIT WILL REQUIRE | | | *ON-SITE* FUEL MEETING THE MINIMUM LOADS FOR THE | | | MINIMUM SPECIFIED TIMES DEPENDING ON INSTALLATION. WHAT | | | ARE THE INTENDED LOADS? 701.5, 700.5, 702.5 | | | | | | 3) NOTE: PLEASE SEE AS OCCUPATION FOR THE DESIGNATED | | | GENERATOR IS NOT KNOWN, PLEASE BE AWARE OF HOUSE BILL | | | 7121 FOR STAND-BY SYSTEMS AND REQUIRED ON-SITE FUEL. | | | | | | 4) NOTE: OK | | | | | | 5) NOTE: PLEASE SEE FS 481.229 AND 471.003, EVEN WHEN | | | THE SCOPE OF WORK IS NOT REQUIRED TO BE DONE BY AN | | | ARCHITECT OR ENGINEER, THE SCOPE OF WORK STILL REQUIRES | | | THE DESIGN TO CONTAIN THE PRINTED NAME AND SIGNATURE OF | | | THE PERSON TAKING RESPONSIBILITY OF SAID PLANS. | | | 106.3.5, 106.1.2 | | | | | | 6) NOTE: PLEASE SEE POSSIBLE BUILDING COMMENTS WITH | | | RESPECT TO ANY FLOOD ZONE WHICH WOULD REQUIRE THE | | | GENERATOR TO BE MOUNTED 6INCHES ABOVE BFE> (IF IN FLOOD | | | ZONE). | | | | | | 7) NOTE: PLEASE SUBMIT TWO COPIES OF ALL DOCUMENTS | | | SPECS/CUT SHEETS. | | | FBC 106.1 | | | | | | 8) NOTE: PLEASE PROVIDE SITE/OVERVIEW OF THE LOCATION | | | OF THIS UNIT AND ALL RELEVANT EQUIPMENT. | | | PLEASE SEE 225.31-225.39 FOR REQUIRED DISCONNECTING | | | MEANS FOR FEEDERS FROM THE GENERATOR. | | | AS NO SITE PLANS AND OTHER NEEDED INFORMATION WAS | | | SUBMITTED NO REVIEW OF THIS FOR CODE COMPLIANCE CAN BE | | | DONE. | | | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES WHICH WILL | | | AFFECT PLANS, SUBMITTED DOCUMENTS AND ELECTRICAL | | | PLANS. | | | | | | ** PLEASE KNOW AS NOT ALL INFORMATION WAS SUBMITTED FOR | | | REVIEW AND DUE TO COMMENTS ABOVE, THERE MAY VERY WELL | | | BE NEW COMMENTS ON THE FOLLOWING REVIEW. | | | NOTES CAN ONLY BE GIVEN BASED ON PLANS/DOCUMENTS | | | SUBMITTED. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-14 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-14 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2007-10-14 14:43:40 | | | | | | | ** DENIED** | | | | | | 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS | | | WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES | | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-110 ( FBC CHAPTER 27 REFERENCED. | | | | | | 2) NOTE: PLEASE SUBMIT LOADS ON THIS EXISTING/NEW | | | GENERATOR TO BE INSTALLED. | | | PLEASE PROVIDE INFORMATION IF THIS UNIT FEEDS ANY | | | EMERGENCY LIFE SAFETY SYSTEMS OR LEGALLY REQUIRED | | | SYSTEMS.700, 701, | | | PLEASE SEE 700.12B3, 701.11B3 AS ANY LIFE SAFETY, OR | | | LEGALLY REQUIRED SYSTEMS FED BY THIS UNIT WILL REQUIRE | | | *ON-SITE* FUEL MEETING THE MINIMUM LOADS FOR THE | | | MINIMUM SPECIFIED TIMES DEPENDING ON INSTALLATION. WHAT | | | ARE THE INTENDED LOADS? 701.5, 700.5, 702.5 | | | | | | 3) NOTE: PLEASE SEE AS OCCUPATION FOR THE DESIGNATED | | | GENERATOR IS NOT KNOWN, PLEASE BE AWARE OF HOUSE BILL | | | 7121 FOR STAND-BY SYSTEMS AND REQUIRED ON-SITE FUEL. | | | | | | 4) NOTE: PLEASE SEE RISER IS MISSING *EQUIPMENT | | | GROUNDING CONDUCTOR* FROM GENERATOR TO ATS. | | | PLEASE SEE 250.110, 250.122 | | | | | | 5) NOTE: PLEASE SEE FS 481.229 AND 471.003, EVEN WHEN | | | THE SCOPE OF WORK IS NOT REQUIRED TO BE DONE BY AN | | | ARCHITECT OR ENGINEER, THE SCOPE OF WORK STILL REQUIRES | | | THE DESIGN TO CONTAIN THE PRINTED NAME AND SIGNATURE OF | | | THE PERSON TAKING RESPONSIBILITY OF SAID PLANS. | | | 106.3.5, 106.1.2 | | | | | | 6) NOTE: PLEASE SEE POSSIBLE BUILDING COMMENTS WITH | | | RESPECT TO ANY FLOOD ZONE WHICH WOULD REQUIRE THE | | | GENERATOR TO BE MOUNTED 6? ABOVE BFE> (IF IN FLOOD | | | ZONE). | | | | | | 7) NOTE: PLEASE SUBMIT TWO COPIES OF ALL DOCUMENTS | | | SPECS/CUT SHEETS. | | | FBC 106.1 | | | | | | 8) NOTE: PLEASE PROVIDE SITE/OVERVIEW OF THE LOCATION | | | OF THIS UNIT AND ALL RELEVANT EQUIPMENT. | | | PLEASE SEE 225.31-225.39 FOR REQUIRED DISCONNECTING | | | MEANS FOR FEEDERS FROM THE GENERATOR. | | | AS NO SITE PLANS AND OTHER NEEDED INFORMATION WAS | | | SUBMITTED NO REVIEW OF THIS FOR CODE COMPLIANCE CAN BE | | | DONE. | | | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES WHICH WILL | | | AFFECT PLANS, SUBMITTED DOCUMENTS AND ELECTRICAL | | | PLANS. | | | | | | ** PLEASE KNOW AS NOT ALL INFORMATION WAS SUBMITTED FOR | | | REVIEW AND DUE TO COMMENTS ABOVE, THERE MAY VERY WELL | | | BE NEW COMMENTS ON THE FOLLOWING REVIEW. | | | NOTES CAN ONLY BE GIVEN BASED ON PLANS/DOCUMENTS | | | SUBMITTED. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-11 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-11 |
Time |
10:20 |
Sent To |
B |
|
| Notes |
| 2008-03-11 10:34:48 | *****PROVISO***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS APPEAR | | | TO HAVE BEEN ADDRESSED, HOWEVER THE APPROPIATE PLAN | | | SHEET(S) TO BE FIRE-STAMPED WHEN THE OTHER REVIEWERS | | | HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-12-19 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-12-19 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2007-12-19 14:18:35 | ***DENIED*** | | | PLEASE NOTE THAT MOST COMMENTS HAVE NOT BEEN | | | ADDRESSED. | | | | | | 1) MINIMUM OF TWO (2) SETS OF MANUFACTURER | | | SPECIFICATION SHEETS ARE REQUIRED. PLEASE INCLUDE ALL | | | DOCUMENTS TO MAKE COMPLETE SUBMITTALS. | | | | | | 2) OK | | | | | | 3) WORK TO COMPLY WITH NFPA 110, STANDARD FOR EMERGENCY | | | AND STANDBY POWER SYSTEMS. PLEASE ADD NOTE TO | | | DRAWINGS. | | | | | | 4) ALTHOUGH ORIGINAL GENERATOR WAS EXISTING, PROTECTION | | | AROUND THE GENERATOR MAY BE REQUIRED IF THE POSSIBILITY | | | OF EXPOSURE TO MECHANICAL DAMAGE EXISTS. | | | | | | 5)WHAT BUILDING FIRE PROTECTION EQUIPMENT IS TIED TO | | | AND POWERED BY THE GENERATOR DURING EMERGENCY | | | OPERATIONS? | | | | | | NEW COMMENT: | | | | | | PLEASE CLEARLY ILLUSTRATE THE LOCATION OF THE GENERATOR | | | AND ASSOCIATED CLEARANCES. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-10-26 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-10-26 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2007-10-26 13:32:41 | ***DENIED*** | | | | | | 1) MINIMUM OF TWO (2) SETS OF MANUFACTURER | | | SPECIFICATION SHEETS ARE REQUIRED. | | | | | | 2) PLEASE CLARIFY IF THE FUEL SOURCE IS PROPANE, | | | NATURAL GAS OR DUEL PHASE. IS THERE AN ON SITE FUEL | | | SOURCE? | | | | | | 3) WORK TO COMPLY WITH NFPA 110, STANDARD FOR EMERGENCY | | | AND STANDBY POWER SYSTEMS. PLEASE ADD NOTE TO | | | DRAWINGS. | | | | | | 4) ALTHOUGH ORIGINAL GENERATOR WAS EXISTING, PROTECTION | | | AROUND THE GENERATOR MAY BE REQUIRED IF THE POSSIBILITY | | | OF EXPOSURE TO MECHANICAL DAMAGE EXISTS. | | | | | | 5)WHAT BUILDING FIRE PROTECTION EQUIPMENT IS TIED TO | | | AND POWERED BY THE GENERATOR DURING EMERGENCY | | | OPERATIONS? | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-11 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2008-03-11 11:22:04 | ****************PROVISO**************** | | | THIS IS A GENERATOR CHANGE-OUT USING EXISTING PIPING, | | | VALVES, REGULATORS ECT.... | | | NOTE: TWO COPIES OF MANUFACTURER'S SPECIFICATIONS FOR | | | THE EXISTING LP/GAS 1ST AND 2ND STAGE REGULATORS WITH | | | THE MAKE, MODEL NUMBER, LOAD CAPACITY, AND A LISTING | | | FROM A THIRD PARTY TESTING AGENCY, REQUIRED. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-05 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-05 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2007-12-05 16:15:04 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | GAS PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | **PLEASE SEE THAT MOST COMMENTS FROM THE PREVIOUS GAS | | | PLAN REVIEW REMAIN. | | | | | | 1. NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS AND | | | DOCUMENTS ALL ATTACHED INTO EACH SET RESPECTIVELY. | | | PLEASE SEE ALL DOCUMENTS FOR EACH TRADE ARE DIVIDED AND | | | NOT IN SETS. PER *106.3.1, APPROVAL OF CONSTRUCTION | | | DOCUMENTS AND *106.1.2 ADDITIONAL DATA. | | | | | | 2. PROVIDE TWO (2) COPIES OF A SITE PLAN OR SURVEY | | | THAT CLEARLY INDICATES THE PROPOSED LOCATION OF THE | | | GENERATOR INDICATING ALL DIMENSIONS FROM PROPERTY LINES | | | AND ADJACENT DWELLING STRUCTURES. | | | **NOTE: COMMENT NOT ADDRESSED. | | | | | | 3. OK, COMMENT ADDRESSED. | | | | | | 4. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | **NOTE: COMMENT NOT ADDRESSED. | | | | | | 5. WHAT TYPE OF GAS GAS IS BEING USED. (LP OR | | | NATURAL) | | | **NOTE: COMMENT IS ADDRESSED IN THE SUBMITTED | | | MANUFACTURE SPECIFICATIONS BY INDICATING GENERATOR IS A | | | DUEL FUEL GENERATOR. HOWEVER THERE ARE NO ISOMETRIC GAS | | | RISER DIAGRAMS SUBMITTED TO INDICATE GENERATOR IS DUEL | | | FUEL. | | | | | | 6. OK, COMMENT ADDRESSED. | | | | | | 7. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | **NOTE: COMMENT NOT ADDRESSED. THERE WERE NO GAS | | | ISOMETRIC RISER DIAGRAMS IN THE RESUBMITTAL. | | | | | | 8. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | **NOTE: COMMENT NOT ADDRESSED. | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | IF GAS DELIVERY PRESSURE IS GREATER THAN 2 PSI PLEASE | | | SUBMIT TWO (2) COPIES OF THE MP REGULATORS BEING USED | | | WITH THE MAKE, MODEL NUMBER, BTU LOAD CAPACITY, AND A | | | LISTING FROM A NATIONALLY RECOGNIZED TESTING | | | LABORATORY. | | | **NOTE: COMMENT NOT ADDRESSED. | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | NOTE: COMMENT NOT ADDRESSED. THE SUBMITTED | | | MANUFACTURER'S SPECIFICATION SHEETS ARE INDICATING | | | GENERATOR IS DUEL FUEL. PLEASE PROVIDE THE REQUESTED LP | | | TANK INFORMATION AND CLEARLY INDICATE IF LP TANK IS NEW | | | OR EXISTING ON THE RESUBMITTAL. | | | | | | 11. 11. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 6.6.1. | | | NOTE: COMMENT NOT ADDRESSED. THE SUBMITTED | | | MANUFACTURER'S SPECIFICATION SHEETS ARE INDICATING | | | GENERATOR IS DUEL FUEL. PLEASE PROVIDE THE REQUESTED LP | | | TANK INFORMATION AND CLEARLY INDICATE IF LP TANK IS NEW | | | OR EXISTING ON THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-26 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-26 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2007-10-26 14:53:54 | DENIED | | | REFERENCE: | | | ** FBC-2004 WITH 05 & 06 REVISIONS, FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | | ** FLORIDA STATUTES (FS). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/COM INSPECTION. | | | | | | ******IMPORTANT INFORMATION****** | | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | | MATION AND GAS (OR DIESEL) INFORMATION | | | IS ALL SUBMITTED AT THE SAME TIME. THE | | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | | FORMATION WILL BE ROUTED TOGETHER. THIS | | | WILL ENSURE THAT ALL OF THE INFORMATION (PARTICULARLY | | | THE MANUFACTURER'S SPECI- | | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | | | 1. PER FBC-2004 CHAPTER 1, SECTION 106.1: SUBMITTAL | | | DOCUMENTS. CONSTRUCTION | | | DOCUMENTS, SPECIAL INSPECTION AND | | | STRUCTURAL OBSERVATION PROGRAMS, AND | | | OTHER DATA SHALL BE SUBMITTED IN TWO OR | | | MORE SETS WITH EACH APPLICATION FOR A | | | PERMIT. | | | | | | 2. PROVIDE TWO (2) COPIES OF A SITE PLAN OR SURVEY | | | THAT CLEARLY INDICATES THE PROPOSED LOCATION OF THE | | | GENERATOR INDICATING ALL DIMENSIONS FROM PROPERTY LINES | | | AND ADJACENT DWELLING STRUCTURES. | | | | | | 3. PROVIDE MANUFACTURER'S SPECFICATIONS FOR THE | | | PROPOSED GENERATOR INDICATING RECOMMENDED SET BACKS | | | FROM STRUCTURES. | | | | | | 4. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE, CORRESPONDING | | | LENGTHS, AND THE TYPE OF PIPE MATERIAL BEING USED ON | | | THE EXISTING SYSTEM PER FBC-2004 FUEL GAS CODE. | | | | | | 5. WHAT IS THE TYPE OF GAS BEING USED? (LP OR | | | NATURAL) | | | | | | 6. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | **NOTE: WHAT IS THE BTU LOAD OF THE EXISTING | | | GENERATOR? | | | | | | 7. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | **NOTE: WHAT IS THE LONGEST LENGTH OF THE EXISTING GAS | | | SYSTEM? | | | | | | 8. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | **NOTE:WHAT IS THE DELIVERY PRESSURE OF THE EXISTING | | | GAS SYSTEM? | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | **NOTE: IF GAS DELIVERY PRESSURE IS GREATER THAN 2 PSI | | | PLEASE SUBMIT TWO (2) COPIES OF THE MP REGULATORS BEING | | | USED WITH THE MAKE, MODEL NUMBER, BTU LOAD CAPACITY, | | | AND A LISTING FROM A NATIONALLY RECOGNIZED TESTING | | | LABORATORY. | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 6.6.1. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-21 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-21 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2008-02-21 14:57:54 | TO "COMM" BD#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2007-11-30 13:32:21 | TO "COMM" BD#28 | | 2007-11-16 15:23:19 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-26 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-17 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2007-10-09 15:23:04 | TO "COMM" BD#41 | | 2007-09-17 10:48:27 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-03 |
Time |
11:19 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-12-03 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-24 |
Time |
09:41 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-10-24 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2007-10-24 09:47:00 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) SEE ZONING REVIEW NOTES, PLEASE CORRECT. | | | | | | 2) PLEASE INDICATE IF GENERATOR IS NATURAL GAS OR | | | PROPANE. | | | | | | 3) PLEASE SUBMIT TWO COPIES OF THE MANUFACTURER'S | | | SPECIFICATION'S AND INSTALLATION INSTRUCTIONS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-29 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-29 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2008-02-29 15:37:30 | ***APPROVED - RESUB #2 - CONTR. CAME IN AND CORRECTED | | | REQUESTED INFORMATION*** | | | | | | PROVISO:GENERATOR SHALL BE SCREENED AND LANDSCAPED IN | | | ACCORDANCE WITH SECTION 94-444(B) OF THE CITY'S ZONING | | | AND LAND DEVELOPMENT REGULATIONS: OUTDOOR STORAGE FOR | | | NONRESIDENTIAL AND MULTIFAMILY USES; STORAGE AND | | | DISPOSAL FACILITIES.OUTDOOR INCINERATORS, GARBAGE OR | | | TRASH RECEPTACLES, FUEL OIL OR PROPANE TANKS, AND | | | STORAGE RACKS SHALL NOT BE PERMITTED UNLESS APPROPRIATE | | | SCREENING IS PROVIDED. SCREENING SHALL BE CONSTRUCTED | | | OF BRICK, DECORATIVE CONCRETE, OTHER DECORATIVE | | | MASONRY, OR COMPARABLY DURABLE WOOD AND STEEL. WALLS | | | SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT | | | TWO-FOOT INTERVALS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-22 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-22 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2008-02-22 08:36:29 | ***FAILED - RESUB #2*** | | | | | | | | | REPEAT COMMENT: | | | | | | 1)INDICATE ON SURVEYS THE PROPOSED GENERATOR SHOWING | | | THE SETBACK DIMENSIONS TO ALL PROPERTY LINES. | | | | | | NOTE:AS THIS IS THE THIRD TIME THIS COMMENT HAS BEEN | | | ISSUED, IF YOU HAVE QUESTIONS REGARDING WHAT I AM | | | ASKING FOR, PLEASE DON'T HESITATE TO CALL THE NUMBER | | | PROVIDED BELOW. | | | | | | NOTE:THE GENERATOR SHALL BE SCREENED AND LANDSCAPED | | | IN ACCORDANCE WITH SECTION 94-444(B) OF THE CITY'S | | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-05 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-05 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2007-12-05 11:17:33 | ***FAILED - RESUB #1*** | | | | | | | | | REPEAT COMMENT: | | | | | | 1)INDICATE ON SURVEYS THE PROPOSED GENERATOR (WITH A | | | PERMANENT UTENSIL) SHOWING THE SETBACK DIMENSIONS TO | | | ALL PROPERTY LINES. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-15 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-15 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2007-10-15 09:19:04 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | | SHOWING THE LOCATION OF THE PROPOSED GENERATOR WITH | | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |