Plan Review Details - Permit 07090406
| Plan Review Stops For Permit 07090406 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-13 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-13 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-18 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-18 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2007-12-18 13:22:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.PROVIDE TWO COMPLETE SETS OF PERMIT DOCUMENTS FOR | | | PERMIT ISSUANCE (ONLY ONE INSTALLATION SCHEDULE | | | PROVIDED). | | | | | | 2. SPECIFY SHUTTER TYPE FOR OPENING 5. | | | | | | 3.OPENING 5, ANCHOR SPACING IS 2".ANCHORS WHICH ARE | | | TOO CLOSE CAN COMPROMISE THE SUBSTRATE.EITHER REVISE | | | OR PROVIDE ENGINEERING TO SHOW THAT 2" SPACING IS | | | ACCEPTABLE.NOTE THAT THE CLOSEST ANCHOR SPACING ON | | | THE ANCHOR CHART IS 3". | | | | | | 4.OPENING 7 SHOWS 7W FOR THE BOTTOM, 6.5" ANCHOR | | | SPACING.7W IS A CEILING TRUSS CONNECTION, 24" | | | SPACING.HOW CAN YOU USE THIS AS THE BOTTOM | | | CONNECTION?PLEASE CLARIFY. | | | | | | 5.OPENINGS 8-13, CONNECTION 5 IS FOR A WALL TOP | | | CONNECTION, SEE SHEET 13. | | | | | | 6.PLEASE CHECK ALL OTHER OPENINGS FOR ERRORS. | | | | | | 7.THERE IS ANOTHER APPLICATION PENDING FOR THE SAME | | | SCOPE OF WORK, 07060867.PLEASE ADDRESS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-14 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-14 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2007-09-14 16:21:31 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT, FBC*106. | | | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | _XX_5.SHOW THE EMERGENCY MEANS OF ESCAPE, BOTH | | | BUILDINGS, FBC R310. | | | | | | _XX_6.PLEASE COORDINATE THE INSTALLATION SCHEDULE | | | WITH THE FLOOR PLAN. | | | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | | R301.2.1.4. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-06 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-06 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
| 2008-06-06 16:13:46 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-10 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-10 |
Time |
08:44 |
Sent To |
B |
|
| Notes |
| 2007-12-10 08:44:25 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-14 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-14 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2007-09-14 09:13:06 | TO "MISC" BOX#1 |
|
|
|