Review Stop G GAS REVIEW
Rev No 2 Status P Date 2007-10-15 Cont ID  
Sent By mperson Date 2007-10-15 Time 13:47 Rev Time 0.00
Received By mperson Date 2007-10-15 Time 13:47 Sent To PC
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-09-28 Cont ID  
Sent By mperson Date 2007-09-28 Time 08:17 Rev Time 0.00
Received By mperson Date 2007-09-28 Time 08:17 Sent To PC
Notes
2007-09-28 08:39:22DENIED
 REFERENCE:
 ** FBC-2004 WITH 05 & 06 REVISIONS, FUEL GAS.
 ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION
 REQUIREMENTS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATIONREQUIRED FOR GAS
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 NOTE: NOT ALL CORRESPONDING LENGTHS OF THE CUT SECTIONS
 ARE GIVEN FOR THE PROPOSED POOL HEATER. THE ONLY
 CORRESPONDING LENGTH FOR THE PROPOSED POOL HEATER IS
 FOR THE UNDERGROUND PE PIPE. WHAT ARE THE CORRESPONDING
 LENGTHS OF THE ABOVE GROUN PIPING.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 NOTE: NOT ALL MATERIAL TYPES OR PIPE SIZES ARE BEING
 INDICATED FOR THE PROPOSED POOL HEATER AND NEW TEE FOR
 THE POOL HEATER. WHAT IS THE ABOVE GROND PIPING
 MATERIAL AND PIPE SIZE FOR THE PROPOSED POOL HEATER AND
 THE NEW TEE FOR THE POOL HEATER?
  
 3. THE EXISTING 3/4" RISER FEEDING THE WATER HEATER
 AND RANGE NEEDS TO INCREASE TO 1" PER TABLE 402.4(2).
  
 4. CLEARLY INDICATE THE MODEL NUMBER OF THE POOL
 HEATER BEING USED ON THE RESUBMITTED MANUFACTURER
 SHEETS.
  
 5. A NOTICE OF COMMENCEMENT IS REQUIRED-PALM BEACH
 COUNTY COURTHOUSE-4TH FLOOR RECORDING DEPT. BEFORE THE
 PERMIT IS ISSUED.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-02 Cont ID  
Sent By adarroug Date 2007-10-02 Time 11:08 Rev Time 0.00
Received By adarroug Date 2007-10-02 Time 11:08 Sent To G
Notes
2007-10-02 11:08:35TO "G" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-28 Cont ID  
Sent By mperson Date 2007-09-28 Time 08:39 Rev Time 0.00
Received By mperson Date 2007-09-13 Time 13:30 Sent To  
Notes
2007-09-13 13:30:42TO "G" BOX


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved