| Plan Review Stops For Permit 07090360 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-18 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-18 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-23 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-23 |
Time |
13:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-03 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-03 |
Time |
06:35 |
Sent To |
G |
|
| Notes |
| 2007-12-03 06:49:17 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1}THE LOAD BEING SERVED BY THE GENERATOR, (86.33 | | | AMPS) IS LARGER THAN THE GENERATOR OUTPUT (75 AMPS). | | | SEE 702.5 CAPACITY AND RATING | | | AN OPTIONAL STANDBY SYSTEM SHALL HAVE ADEQUATE CAPACITY | | | AND RATING FOR THE SUPPLY OF ALL EQUIPMENT INTENDED TO | | | BE OPERATED AT ONE TIME. OPTIONAL STANDBY SYSTEM | | | EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM AVAILABLE | | | FAULT CURRENT AT ITS TERMINALS. THE USER OF THE | | | OPTIONAL STANDBY SYSTEM SHALL BE PERMITTED TO SELECT | | | THE LOAD CONNECTED TO THE SYSTEM. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-27 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-27 |
Time |
06:42 |
Sent To |
P |
|
| Notes |
| 2007-09-27 07:44:33 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} PROVIDE A RISER DIAGRAM PER 215.5 | | | INCLUDING GENERATOR AND RELATED | | | EQUIPMENT. | | | | | | 2} PROVIDE A LOAD CALCULATION FOR THE | | | LOAD INTENDED TO BE SERVED. 215.5. 702.5, 2005NEC | | | | | | 3} PROVIDE A PANEL SCHEDULE FOR THE | | | GENERATOR PANEL. 106.3.5.4 FBC AS | | | AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-07 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-07 |
Time |
09:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-01 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-01 |
Time |
15:17 |
Sent To |
B |
|
| Notes |
| 2007-10-01 16:38:52 | DENIED | | | REFERENCE: | | | ** FBC-2004 WITH 05 &O6 REVISONS, FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTION/INFORMATION IS REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PER FBC-2004 W/O5 & 06 REV, TABLE 402.4(2) THE | | | ABOVE GROUND SCH 40 METALLIC PIPING NEEDS TO BE 1 INCH | | | (1"). PLEASE PROVIDE MANUFACTURER'S SPECIFICATIONS OF A | | | 1 INCH SCH 40 METALLIC TO 3/4 INCH PE TRANSITION OR | | | CHANGE ALL PIPE SIZES TO BE 1 INCH ON THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-20 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-20 |
Time |
11:58 |
Sent To |
E |
|
| Notes |
| 2008-05-20 11:58:49 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-27 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-27 |
Time |
14:22 |
Sent To |
E |
|
| Notes |
| 2007-11-27 14:22:40 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-18 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-13 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2007-09-13 10:21:36 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-21 |
Time |
08:27 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-09-21 |
Time |
08:27 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-18 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-18 |
Time |
09:25 |
Sent To |
E |
|
| Notes |
| 2007-09-18 09:26:07 | APPROVED GENERATOR LOCATION |
|
|