| Plan Review Stops For Permit 07090359 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-04-01 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-04-01 |
Time |
17:45 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-03-22 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-03-22 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-03-22 |
Time |
11:20 |
Sent To |
PC |
|
| Notes |
| 2008-03-22 11:28:18 | | | | | | | DENIED | | | | | | THE FOLLOWING REVIEW COMMENTS WERE NOT FULLY ADDRESSED | | | FROM 1ST AND 2ND BUILDING REVIEWS: | | | | | | 2)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THATIS RELEVANT PER 9B-72. | | | THESE SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS THE SYSTEM | | | COMPONENTS/ FASTENER LIST PAGES. ALL CAN BE FOUND ON | | | WWW.FLORIDABUILDING.ORG*******MISSING APPROVALS FOR | | | SIMPSON TIES HETA 20 TRUSS ANCHOR******** | | | | | | 9)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. ********DRAWINGS MUST BE STAMPED BY COUNTY | | | AND FEE RECIEPT PROVIDED********** | | | | | | 10)SHOW THAT NEW ROOF/CEILING THAT HAS BECOME PART OF | | | CONDITIONED SPACE WILL RECEIVE INSULATION, NOTE SUBMIT | | | TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 FBC. BE SURE | | | THAT THEY ARE SIGNED AND DATED BY PREPARER AND | | | OWNER/AGENT PRIOR TO SUBMITTAL. | | | ********NOT SIGNED AND DATED BY OWNER/AGENT********** | | | | | | NEW COMMENT | | | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 & | | | 2007AMENDMENTS PER 106.1.1 FBC* | | | | | | | | | ****PLEASE NOTE FLORIDA STATEWIDE PRODUCT APPROVAL | | | SHEETS WERE ADDED BY REVIEWER, THE CITY OF WEST PALM | | | BEACH REQUIRES THE FLORIDA STATE PRODUCT APPROVAL | | | SHEETS AND APPLICABLE CERTIFYING INFORMATION/DRAWINGS | | | WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | | SUBMITTED APPLICATIONS WILL BE DENIED. PLEASE KEEP IN | | | MIND FOR FUTURE PERMIT APPLICATIONS**** | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-01-15 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-01-15 |
Time |
17:40 |
Sent To |
PC |
|
| Notes |
| 2008-01-15 18:15:35 | | | | | | | | | | DENIED | | | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESS FROM THE 1ST | | | REVIEW: | | | | | | 1)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE | | | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS | | | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN | | | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 | | | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND | | | PRESSURES ACCORDINGLY.*** BE SURE TO CHECK PRODUCT | | | APPROVALS FOR COMPLIANCE WITH INCREASED DESIGN | | | PRESSURE*** | | | *********NOTE THIS IS AN EXPOSURE C PLEASE ADJUST WIND | | | INFORMATION AND OPENING DESIGN PRESSURES********* | | | | | | 2)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THATIS RELEVANT PER 9B-72. | | | THESE SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS THE SYSTEM | | | COMPONENTS/ FASTENER LIST PAGES. ALL CAN BE FOUND ON | | | WWW.FLORIDABUILDING.ORG ****PROVIDE PRODUCT | | | APPROVALS FOR THE CASTCRETE LINTELS, CONNECTOR | | | STRAPS/TIES, ETC.**** | | | ***********NOTE PROVIDE LINTEL AND CONNECTOR PRODUCT | | | APPROVAL SHEETS, ALSO NOTE THAT SEVERAL DIFFERENT | | | PRODUCT APPROVALS WERE SUBMITTED IN PACKAGE FOR WINDOWS | | | AND DOORS . PLEASE SUBMIT ONLY 2 COPIES OF EACH PRODUCT | | | THAT WILL BE USED MAKING SURE THAT THEY ARE LEDGIBLE | | | AND EACH IS REVIEWED AND APPROVED FOR USE BY THE | | | DESIGNER OF RECORD*********** | | | | | | 3)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 9)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10)SHOW THAT NEW ROOF/CEILING THAT HAS BECOME PART OF | | | CONDITIONED SPACE WILL RECEIVE INSULATION | | | **********NOTE SUBMIT TWO COPIES OF ENERGY CALC'S PER | | | 13-101.2.2 FBC. BE SURE THAT THEY ARE SIGNED AND DATED | | | BY PREPARER AND OWNER/AGENT PRIOR TO SUBMITTAL. SMALL | | | ADDITIONS UNDER 600 SQ. FT CAN USE SHORT FORM 600C-04R | | | BUT PLEASE NOTE THAT R30 MUST BE INSTALLED IN CEILING | | | ATTIC AND BLOCK WALL REQUIRE A MINIMUM R7*********** | | | | | | 11)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | | | | NEW COMMENTS: | | | | | | 1)IF WINDOWS AND DOORS THAT ARE BEING INSTALLED IN | | | THE NEW ADDITION ARE NOT IMPACT RESISTANT PLEASE SUBMIT | | | PRODUCT APPROVALS AND INSTALLATION SCHEDULE FOR | | | PROTECTIVE DEVICES. SEE ATTACHED CITY MEMO AND | | | SCHEDULE | | | | | | 2)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS | | | OF NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF | | | THE OLD PAGES ONLY FOR REFERENCE. PLEASE ASSEMBLE ALL | | | SIGNED AN SEALED DRAWINGS THAT PERTAIN TO WORK BEING | | | PERFORMED, TOGETHER IN COMPLETE SETS AND SUBMIT WITH | | | ONLY 1 SET OF REFERENCE DRAWINGS. PLEASE SUBMIT | | | REQUIRED DOCUMENTS FOR ALL OTHER REVIEWERS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-19 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-10-06 |
Time |
14:15 |
Sent To |
PC |
|
| Notes |
| 2007-10-06 15:30:03 | | | | | | | DENIED | | | | | | 1)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE | | | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS | | | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN | | | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 | | | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND | | | PRESSURES ACCORDINGLY.*** BE SURE TO CHECK PRODUCT | | | APPROVALS FOR COMPLIANCE WITH INCREASED DESIGN | | | PRESSURE*** | | | | | | 2)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THATIS RELEVANT PER 9B-72. | | | THESE SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS THE SYSTEM | | | COMPONENTS/ FASTENER LIST PAGES. ALL CAN BE FOUND ON | | | WWW.FLORIDABUILDING.ORG ****PROVIDE PRODUCT | | | APPROVALS FOR THE CASTCRETE LINTELS, CONNECTOR | | | STRAPS/TIES, ETC.**** | | | | | | 3)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | | | | 4)LABEL THE ORIGINAL PHOTOCOPIED DRAWINGS AS | | | "REFERENCE ONLY" | | | | | | 5)PROVIDE THE DESIGN PRESSURES FOR THE NEW OPENINGS | | | | | | 6)PROVIDE ENGINEERED SUBSTRATE ATTACHMENT FOR THE | | | DOOR AND WINDOW WOOD BUCKS PER 1714.5.4.1 FBC | | | | | | 7)PROVIDE CONNECTION DETAIL FOR NEW BLOCK WALL TO THE | | | EXISTING WOOD BEAM | | | | | | 8)THE EXISTING PATIO HAS A 3 1/2" STEP DOWN AT | | | LIVINGROOM DOOR AND SLOPES 1/8" PER FOOT TO THE EDGE OF | | | SLAB 29 FEET AWAY THIS WILL CREATE APPROXIMATELY 7 1/8" | | | DROP IN FLOOR LEVEL FROM THE EXISTING FAMILY ROOM AREA. | | | PLEASE SHOW A CLEAR DETAIL OF THE NEW FOUNDATION AND | | | SLAB TIE INS, SECTIONS A-1 AND A-2 ARE NOT SHOWN OR NOT | | | LABELED. IS THE EXT. WALL AT PATIO DETAIL EXISTING OR | | | NEW AND THE WILL THE FOUNDATION FOR NEW WALL AT SGD BE | | | CUT INTO EXISTING SLAB AND TIED BACK IN WITH DOWELS, | | | PLEASE CLARIFY | | | | | | 9)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, AND A | | | COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10)SHOW THAT NEW ROOF/CEILING THAT HAS BECOME PART OF | | | CONDITIONED SPACE WILL RECEIVE INSULATION | | | | | | 11)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-21 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-21 |
Time |
09:59 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-07 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-07 |
Time |
06:55 |
Sent To |
B |
|
| Notes |
| 2008-01-07 07:57:59 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THIS COMMENT FROM THE PREVIOUS REVIEW. | | | | | | PER R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | | INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS | | | SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE | | | LOCATION OF SMOKE ALARMS ON THE PLANS.* THIS COMMENT | | | WAS MADE TO DETERMINE COMPLIANCE WITH THE ARTICLE, A | | | SMOKE ALARM IS NOT REQUIRED IN THE ADDITION. | | | | | | THE ELECTRICLE PLANS SUBMITTED ARE ON SHEET A-1.0, THE | | | ARCHITECTURAL PLANS ARE ON A SHEET MARKED A-1.0. FOR | | | RECORD RETENTION SEPERATLY NUMBER THE SHEETS, AND | | | ASSEMLE THE SHEETS INTO TWO SETS. 106.1.6 FBC AS | | | AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-19 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-19 |
Time |
14:52 |
Sent To |
M |
|
| Notes |
| 2007-09-19 15:20:56 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | NO ELECTRICAL PLANS WERE SUBMITTED, AND NO ELECTRICAL | | | CONTRACTOR IS SIGNED ON, HOWEVER RECEPTACLES ARE | | | REQUIRED PER 210.52 ANSD LIGHTING PER 210.70. AN | | | ELECTRICAL PERMIT IS REQUIRED. | | | | | | PER R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | | INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS | | | SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE | | | LOCATION OF SMOKE ALARMS ON THE PLANS | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-31 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-31 |
Time |
14:07 |
Sent To |
Z |
|
| Notes |
| 2008-03-31 14:08:17 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-18 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-18 |
Time |
09:45 |
Sent To |
Z |
|
| Notes |
| 2008-03-18 09:45:40 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-31 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-31 |
Time |
09:40 |
Sent To |
Z |
|
| Notes |
| 2007-12-31 09:41:12 | TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-10-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-13 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2007-09-13 15:25:34 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-20 |
Time |
08:06 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-09-20 |
Time |
08:06 |
Sent To |
B |
|
| Notes |
| 2007-09-20 08:09:41 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-01 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-01 |
Time |
09:19 |
Sent To |
B |
|
| Notes |
| 2008-04-01 09:20:20 | ***APPROVED - RESUB #3*** | | | | | | | | | | | | | | | SENT TO "B" - AM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-19 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-19 |
Time |
08:59 |
Sent To |
E |
|
| Notes |
| 2008-03-19 09:00:17 | ***FAILED - RESUB #2*** | | | | | | | | | REPEAT COMMENTS: | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING | | | THE SCOPE OF WORK BEING PROPOSED WITH DIMENSIONS AND | | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-01-04 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-04 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-04 |
Time |
15:08 |
Sent To |
E |
|
| Notes |
| 2008-01-04 15:09:18 | ***FAILED - RESUB #1*** | | | | | | | | | REPEAT COMMENTS: | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING | | | THE SCOPE OF WORK BEING PROPOSED WITH DIMENSIONS AND | | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-14 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-14 |
Time |
17:28 |
Sent To |
E |
|
| Notes |
| 2007-09-14 17:30:16 | ***FAILED*** | | | | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY SHOWING | | | THE SCOPE OF WORK BEING PROPOSED WITH DIMENSIONS AND | | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|