| Plan Review Stops For Permit 07090338 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-16 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-10-16 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2007-10-16 07:55:32 | 2004 FBC W/2007 REVISIONS | | | INSTALL POOL WITH GAS HEATER | | | | | | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-18 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-18 |
Time |
16:51 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-30 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-30 |
Time |
14:31 |
Sent To |
PC |
|
| Notes |
| 2007-10-30 14:33:16 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-27 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-27 |
Time |
14:15 |
Sent To |
B |
|
| Notes |
| 2007-09-27 14:18:54 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-18 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-18 |
Time |
10:17 |
Sent To |
P |
|
| Notes |
| 2007-10-18 10:17:23 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-16 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-09-12 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2007-09-12 16:33:43 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-30 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-30 |
Time |
14:30 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-27 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-27 |
Time |
13:49 |
Sent To |
G |
|
| Notes |
| 2007-09-27 14:14:52 | DENIED | | | REFERENCE: | | | ** FBC-2004 WITH 05 & 06 REVISIONS SECTIONS 424.2 AND | | | R4101 SWIMMING POOLS. | | | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET 1 POOL DATA & EQUIPMENT INDICATES THE | | | FOLLOWING "HEATER: EXISTING GAS HEATER". PLEASE CLARIFY | | | ON THE RESUBMITTAL HOW A NEW POOL AND SPA HAS AN | | | EXISTING GAS HEATER. | | | | | | 2. FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | | | | 3. FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | | | | 4. FBC-2004 SEC. 424.2.14, OR FBCR-2004 | | | SEC. R4101.15 GAS PIPING SHALL COMPLY | | | WITH FBC FUEL GAS. SEPARATE PLANS AND | | | PERMIT REQUIRED. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-17 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-17 |
Time |
13:38 |
Sent To |
E |
|
| Notes |
| 2007-09-17 13:39:11 | PROVISO:POOL EQUIPMENT SHALL NOT BE CLOSER THAN 3.5' | | | TO THE EAST SIDE PROPERTY LINE. |
|
|