Plan Review Details - Permit 07090305
Plan Review Stops For Permit 07090305
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-11-08 Cont ID  
Sent By amorse Date 2007-11-08 Time 16:16 Rev Time 0.00
Received By amorse Date 2007-11-08 Time 16:16 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-30 Cont ID  
Sent By amorse Date 2007-10-30 Time 17:16 Rev Time 0.00
Received By amorse Date 2007-10-30 Time 17:16 Sent To PC
Notes
2007-10-30 17:19:37 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED,
 IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE
 ACTUAL PERMIT SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
 THE DRAWINGS ARE REQUIRED TO BE STAMPED EVEN IF IMPACT
 FEES ARE NOT ASSESSED.
  
 2)APPLICATION OF SIMPSON TIE RTA (2) FOR TRUSS TO
 LEDGER ATTACHMENT DOES NOT APPEAR TO WORK, CONNECTOR IS
 FOR USE WHERE TWO 2X MEMBERS ARE CONNECTED AT 90
 DEGREES TO EACH OTHER. CONFIRM USE OF THIS CONNECTOR
  
 3)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-10-02 Cont ID  
Sent By amorse Date 2007-10-02 Time 15:17 Rev Time 0.00
Received By amorse Date 2007-10-02 Time 15:17 Sent To PC
Notes
2007-10-02 16:07:38 
  
 DENIED
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*
  
 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING
 MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF
 ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND
 STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE
 DRAWINGS
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $311.63 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 5)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED. PLEASE SEE
 EXAMPLE ATTACHED FOR THE HORIZONTAL SLIDING GLASS
 WINDOWS
  
 8)NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOFING
 SHINGLES, LINTELS,AND CONNECTORS AND STRAPS. PLEASE
 NOTE THE CONNECTORS MAY BE PROVIDED IN A SCHEDULE WITH
 THE UPLIFTS AND STATEWIDE PRODUCT APPROVAL NUMBERS
 INSTEAD OF PRODUCT APPROVALS. ALSO PRODUCT APPROVAL WAS
 SUBMITTED FOR SINGLE HUNG WINDOWS AND NONE ARE PRESENT
 ON DRAWINGS OR SCHEDULE.
  
 9)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD
  
 10)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 11)PROVIDE THE FOLLOWING INFORMATION ON THE
 DRAWINGS:
  
 A) PROVIDE SCHEDULE FOR PRE CAST LINTEL THAT WILL BE
 USED AND OPENING SIZES TO COMPLY WITH 2104.1.5 FBC
  
 B) DRAWINGS SHALL SHOW THE MINIMUM DEPTH OF FOUNDATION
 ON THE WALL SECTIONS PER R403.1.4 FBC RES.
  
 C) PROVIDE MIN ROOF SHEATHING ATTACHMENT PER R803.2.3.1
 FBC RES. NOTE USE OF 8D RING SHANK
  
 D) PROVIDE BEAM ELEVATIONS,ROOF PITCH AND MEAN ROOF
 HEIGHT ON ELEVATIONS
  
 E) PROVIDE DIMENSIONS OF THE ADDITIONAT THE REAR ON
 THE FLOOR OR FOUNDATION PLAN
  
 F) NO DETAIL WAS PROVIDED FOR THE INFILL AREAS OF
 EXISTING WALLS
  
 G) PROVIDE ATTACHMENT METHOD FOR THE TRUSS LEDGER ON
 HIGH SIDE WALL
  
 H) DESIGN PRESSURES IN THE DOOR AND WINDOW SCHEDULE ARE
 ALL POSITIVE PSF"S
  
 12)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-10-29 Cont ID  
Sent By btrobaug Date 2007-10-29 Time 07:13 Rev Time 0.00
Received By btrobaug Date 2007-10-29 Time 06:55 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-09-17 Cont ID  
Sent By btrobaug Date 2007-09-17 Time 16:13 Rev Time 0.00
Received By btrobaug Date 2007-09-17 Time 16:08 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-11-06 Cont ID  
Sent By adarroug Date 2007-11-06 Time 09:20 Rev Time 0.00
Received By adarroug Date 2007-11-06 Time 09:20 Sent To Z
Notes
2007-11-06 09:21:11TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-25 Cont ID  
Sent By adarroug Date 2007-10-25 Time 09:22 Rev Time 0.00
Received By adarroug Date 2007-10-25 Time 09:22 Sent To Z
Notes
2007-10-25 09:22:25TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-10-02 Time   Rev Time 0.00
Received By adarroug Date 2007-09-12 Time 09:02 Sent To  
Notes
2007-09-12 09:02:45TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-10-29 Cont ID  
Sent By tgordon Date 2007-10-29 Time 11:34 Rev Time 0.30
Received By tgordon Date 2007-10-29 Time 11:34 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-09-18 Cont ID  
Sent By tgordon Date 2007-09-18 Time 08:33 Rev Time 0.25
Received By tgordon Date 2007-09-18 Time 08:33 Sent To B
Notes
2007-09-18 08:40:19PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, SEE FBC
 13-101.2.2. AND ENERGY CALCULATIONS WILL NEED TO BE
 SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2.
  
 2) PROVIDE FOR RETURN AIR TO THE NEW OFFICE, SEE RES.
 M1602.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2007-11-08 Cont ID  
Sent By choops Date 2007-11-08 Time 08:28 Rev Time 0.00
Received By choops Date 2007-11-08 Time 08:28 Sent To B
Notes
2007-11-08 08:28:43***APPROVED - RESUB #2***
  
  
  
  
 SENT TO "B" - AM

Review Stop Z ZONING
Rev No 2 Status F Date 2007-10-26 Cont ID  
Sent By choops Date 2007-10-26 Time 14:18 Rev Time 0.00
Received By choops Date 2007-10-26 Time 14:18 Sent To E
Notes
2007-10-26 14:21:21***FAILED - RESUB #1***
  
  
 REPEAT COMMENTS:
  
 1)SHOW THE SETBACK DIMENSIONS FROM PROPOSED ADDITION
 TO ALL PROPERTY LINES.NOTE: MUST BE A MINIMUM OF 10'
 TO REAR AND 10' TO NONZERO SIDE.
  
 NEW COMMENTS:
  
 2)AS THE REAR SITE WALL IS NOW SHOWN ON PLANS, AND
 EASEMENT CONSENT FORM SHALL BE APPROVED BY THE CITY'S
 DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY HALL)
 AND SUBMITTED WITH PERMIT APPLICATION.
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-09-13 Cont ID  
Sent By choops Date 2007-09-13 Time 14:22 Rev Time 0.00
Received By choops Date 2007-09-13 Time 14:22 Sent To E
Notes
2007-09-13 14:25:29***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK WITH DIMENSIONS AND SETBACK
 DIMENSIONS FROM PROPOSED TO ALL PROPERTY LINES.
  
 2)INDICATE HEIGHTS ON ELEVATIONS FROM GRADE.
  
 3)PROVIDE ALL OVERHANG DIMENSIONS.
  
 4)SHOW ALL PROPOSED OR RELOCATED (IF ANY) A/C
 EQUIPMENT WITH SETBACK DIMENSIONS TO THE PROPERTY
 LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720