| Plan Review Stops For Permit 07090045 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-16 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-16 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-25 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-25 |
Time |
08:35 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-01-08 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-01-07 |
Time |
13:11 |
Sent To |
PC |
|
| Notes |
| 2008-01-07 15:57:49 | REVIEW IN PROGRESS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-12-14 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-12-13 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2007-12-14 05:45:56 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07090045 | | | ADD: 114 S. NARCISSUS AVE | | | CONT: YOUCHAK & YOUCHAK, INC. | | | TEL: (561)832-3800 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006/2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | **= NEW COMMENT** | | | REVIEW: 3RD 12/13/07 | | | ACTION: DENIED | | | | | | 1) OK | | | 2)FBC 3202.2DOORS AND WINDOWS SHALL NOT OPEN OR | | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. THE DOOR ON THE | | | SOUTH ELEVATION CANNOT SWING OVER THE PROPERTY LINE. | | | **THE DOORS SHALL BE RECESS, TO PREVENT THEM FROM | | | SWINGING INTO THE PUBLIC RIGHT-RIGHT- WAY. ** SHOW THE | | | ENTRANCE DOOR CHANGE ON ALL PAGES REFLECTING THE | | | ENTRANCE. ** | | | SHEET C6A WHICH SHOWS THE PROPOSED NEW MAIN ENTRANCE | | | INDICATES THE NEW DOOR AS A 3? X 7?. THE PRODUCT | | | APPORVAL SUBMITTED IS FOR A 4-0 X 7-0 DOOR. WILL THE | | | EXISTING GLASS REMAIN OR WILL IT BE REMOVED TO CREATE A | | | LARGER OPENING? CLARIFY. | | | | | | 3)PER FBC TABLE 704.8 NO OPENINGS ARE PERMITTED IN | | | WALLS 3 FEET OR LESS FROM THE PROPERTY LINE. FOR MORE | | | INFORMATION SEE TABLE 602. INDICATE THE DISTANCE | | | BETWEEN EACH PROPERTY LINE AT THE NORTH ELEVATION. | | | **THE LOCATION OF THE PREVIOUS DOOR ON NARCISSUS WAS | | | CONSTRUCTED TO PREVENT IT FROM SWINGING OVER THE PUBLIC | | | RIGHT-OF WAY. THE NEW DOOR LOCATION SHALL MEET THE | | | REQUIREMENT OF FBC 3202.2. WHEN THE OCCUPANT LOAD IS | | | MORE THAN 50 THE DOOR SHALL SWING IN THE DIRECTION OF | | | EGRESS TRAVEL FBC 1008.1.2. ** THE DOORS SHALL BE | | | RECESS, TO PREVENT THEM FROM SWINGING INTO THE PUBLIC | | | RIGHT-OF- WAY. | | | **THE MAIN ENTRANCE DOOR IS IN THE SAME LOCATION | | | SWINGING INTO THE PUBLIC RIGHT-OF-WAY ON MANY PAGES. | | | ALL PAGES WHICH SHOW THE MAIN ENTRANCE SHALL SHOW | | | CLEARLY HOW IT WILL BE CONSTRUCTED. IF CHANGES WERE | | | MADE, SHOW IT ON ALL PAGES. ** | | | | | | 4)OK | | | 5)OK | | | 6)OK | | | 7)OK | | | 8)OK | | | 9)OK | | | 10)OK | | | 11)OK | | | | | | PAGES 9-11 DO NOT SHOW THE ITEMS SPECIFIC TO THE | | | SHUTTERS. | | | 12)106.3.3* PRODUCT APPROVALS- 2004 THOSE PRODUCTS | | | THAT ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. THE PRODUCT | | | APPROVALS SUBMITTED SHALL INDICATE WHICH ITEMS OR | | | SYSTEMS WILL BE USED TO INSTALL THE PRODUCT. THE | | | PRODUCT APPROVALS SHALL BE APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | **NOTED: ON THE PRODUCT APPROVAL, MARK WHICH DETAILS | | | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A | | | HIGHLIGHTER. COMPLETE THE ATTACHED INSTALLATION | | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | | COMPLIANCE IN ANOTHER FORMAT (SHUTTERS) **ON PAGES 9-11 | | | INDICATE WHICH ROW AND COLUMN PERTAIN TO THE SHUTTER | | | INSTALLATION. ** | | | | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-11-14 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-11-10 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2007-11-14 13:55:34 | | | | | | | | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07090045 | | | ADD: 114 S. NARCISSUS AVE | | | CONT: YOUCHAK & YOUCHAK, INC. | | | TEL: (561)832-3800 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006/2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | **= NEW COMMENT** | | | REVIEW: 2ND 11/10/07 | | | ACTION: DENIED | | | | | | 1) OK | | | | | | 2)FBC 3202.2DOORS AND WINDOWS SHALL NOT OPEN OR | | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. THE DOOR ON THE | | | SOUTH ELEVATION CANNOT SWING OVER THE PROPERTY LINE. | | | **THE DOORS SHALL BE RECESS, TO PREVENT THEM FROM | | | SWINGING INTO THE PUBLIC RIGHT-RIGHT- WAY.** | | | FBC11-4.5.2 CHANGES IN LEVEL GREATER THAN ? INCH SHALL | | | BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH | | | SECTION 11-4.7 OR 11-4.8. THIS SECTION REFERS TO ALL | | | DOORS. | | | | | | 3)PER FBC TABLE 704.8 NO OPENINGS ARE PERMITTED IN | | | WALLS 3 FEET OR LESS FROM THE PROPERTY LINE. FOR MORE | | | INFORMATION SEE TABLE 602. INDICATE THE DISTANCE | | | BETWEEN EACH PROPERTY LINE AT THE NORTH ELEVATION. | | | **THE LOCATION OF THE PREVIOUS DOOR ON NARCISSUS WAS | | | CONSTRUCTED TO PREVENT IT FROM SWINGING OVER THE PUBLIC | | | RIGHT-OF WAY. THE NEW DOOR LOCATION SHALL MEET THE | | | REQUIREMENT OF FBC 3202.2. WHEN THE OCCUPANT LOAD IS | | | MORE THAN 50 THE DOOR SHALL SWING IN THE DIRECTION OF | | | EGRESS TRAVEL FBC 1008.1.2. ** THE DOORS SHALL BE | | | RECESS, TO PREVENT THEM FROM SWINGING INTO THE PUBLIC | | | RIGHT-RIGHT- WAY.** FBC11-4.5.2 CHANGES IN LEVEL | | | GREATER THAN ? INCH SHALL BE ACCOMPLISHED BY MEANS OF A | | | RAMP THAT COMPLIES WITH SECTION 11-4.7 OR 11-4.8. THIS | | | SECTION REFERS TO ALL DOORS. | | | | | | 4)OK | | | 5)OK | | | 6)OK | | | 7)OK | | | 8)OK | | | | | | 9)FBC 106.3.5.1.1 SUBMIT THE LIFE SAFETY PLAN | | | INDICATING THE MEANS OF EGRESS, EXIT ACCESS, EXIT, EXIT | | | DISCHARGE. THE EXTERIOR ELEVATIONS SHALL INCLUDE ALL | | | STEPS, RAMPS AND LANDINGS LEADING TO OR FROM THE EGRESS | | | DOORS. | | | **ARE ALL THE EXITS SHOWN ON DRAWINGS HANDI-CAP | | | ACCESSIBLE? IF NOT, THE ONES WHICH ARE SHALL BE CLEARLY | | | SHOWN. | | | | | | 10)SHOW THE ACCESSIBLE ROUTE LEADING TO THE EXIT | | | DOORS. SIGNS SHALL BE PLACE IN ACCORDANCE WITH SECTIONS | | | 11-4.30.6 / 11-4.1/ 11-4.3. | | | ** NOTED: HOWEVER, IT SEEMS AS THOUGH ALL THE DOORS ARE | | | NOT HANDI-CAP ACCESSIBLE.** | | | | | | 11)OK | | | 12)106.3.3* PRODUCT APPROVALS- 2004 THOSE PRODUCTS | | | THAT ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. THE PRODUCT | | | APPROVALS SUBMITTED SHALL INDICATE WHICH ITEMS OR | | | SYSTEMS WILL BE USED TO INSTALL THE PRODUCT. THE | | | PRODUCT APPROVALS SHALL BE APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | **NOTED: ON THE PRODUCT APPROVAL, MARK WHICH DETAILS | | | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A | | | HIGHLIGHTER. COMPLETE THE ATTACHED INSTALLATION | | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | | COMPLIANCE IN ANOTHER FORMAT(SHUTTERS) | | | | | | **NEW** | | | A) 2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. DUE TO THE FACT | | | THAT THE INTERIOR CONSTRUCTION OF THE BUILDING WAS | | | COMPLETELY DEMOED, THIS ALTERATION SEEMS TO BE A LEVEL | | | 3 ALTERATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-10-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-04 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-02 |
Time |
06:07 |
Sent To |
|
|
| Notes |
| 2007-10-03 18:57:25 | BUILDING PLAN REVIEW | | | PERMIT: 07090045 | | | ADD: 114 S. NARCISSUS AVE | | | CONT: YOUCHAK & YOUCHAK, INC. | | | TEL: (561)832-3800 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006/2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS, PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A | | | RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD | | | BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE | | | SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT | | | ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS WEST PALM | | | BEACH ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 2)FBC 3202.2DOORS AND WINDOWS SHALL NOT OPEN OR | | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. THE DOOR ON THE | | | SOUTH ELEVATION CANNOT SWING OVER THE PROPERTY LINE. | | | | | | 3)PER FBC TABLE 704.8 NO OPENINGS ARE PERMITTED IN | | | WALLS 3 FEET OR LESS FROM THE PROPERTY LINE. FOR MORE | | | INFORMATION SEE TABLE 602. INDICATE THE DISTANCE | | | BETWEEN EACH PROPERTY LINE AT THE NORTH ELEVATION. | | | | | | 4)ALL PLANS SUBMITTED AFTER OCTOBER, 1, 2004 SHALL BE | | | DESIGNED TO THE 2004 FLORIDA BUILDING CODE WITH THE | | | 2006 AND 2007 REVISIONS. THERE IS SOME INFORMATION ON | | | SHEET C2 WHICH REFER TO THE PREVIOUS CODE E.G. ASCE | | | 7-98 WAS IN THE 2001 CODE SEE CHAPTER 35 FOR THE NEW | | | REFERENCE STANDARDS. WE ARE USING THE CITY OF WEST PALM | | | BEACH AMENDMENTS NOT PALM BEACH COUNTY AMENDMENTS. | | | THERE IS NO TABLE 500 IN THE 2004 FBC. | | | | | | 5)61G15-23.002 EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF CHAPTER 471, | | | F.S., SHALL BE SEALED, SIGNED AND DATED BY THE | | | PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. ENGINEERS | | | SHALL LEGIBLY INDICATE THEIR NAME, ADDRESS AND LICENSE | | | NUMBER, AS WELL AS, THE NAME, ADDRESS, AND CERTIFICATE | | | OF AUTHORIZATION NUMBER OF THE ENGINEERING BUSINESS ON | | | EACH SHEET. | | | | | | 6)FBC 1003.5.2 WHERE CHANGE IN ELEVATION OF 12 INCHES | | | OR LESS OCCURS IN EXIT ACCESS CORRIDORS, EXITS AND EXIT | | | DISCHARGE, RAMPS COMPLYING WITH SECTION 1010 SHALL BE | | | PROVIDED. THE RAMP SHALL BE IN CONFORMANCE WITH SECTION | | | 11-4.8. | | | | | | 7)INDICATE THE CLEAR FLOOR SPACE ON THE DRAWINGS FOR | | | THE HANDI-CAP LAVATORIES AND URINALS PER SEC 11-4.18 | | | AND 11-4.19. | | | | | | 8)TABLE 803.3 MINIMUM INTERIOR FINISH CLASSIFICATION; | | | PROVIDE INFORMATION BASED ON INTERIOR FINISH | | | REQUIREMENTS BASED ON OCCUPANCY. | | | | | | 9)FBC 106.3.5.1.1 SUBMIT THE LIFE SAFETY PLAN | | | INDICATING THE MEANS OF EGRESS, EXIT ACCESS, EXIT, EXIT | | | DISCHARGE. THE EXTERIOR ELEVATIONS SHALL INCLUDE ALL | | | STEPS, RAMPS AND LANDINGS LEADING TO OR FROM THE EGRESS | | | DOORS. | | | | | | 10)SHOW THE ACCESSIBLE ROUTE IN LEADING TO THE EXIT | | | DOORS. SIGNS SHALL BE PLACE IN ACCORDANCE WITH SECTIONS | | | 11-4.30.6 / 11-4.1/ 11-4.3. | | | | | | 11)FBC 11-5.2 WHERE FOOD OR DRINK IS SERVED AT | | | COUNTERS EXCEEDING 34 INCHES IN HEIGHT FOR CONSUMPTION | | | BY CUSTOMERS SEATED ON STOOLS OR STANDING AT THE | | | COUNTER, A PORTION OF THE MAIN COUNTER SHALL BE 60 | | | INCHES IN LENGTH AND COMPLY WITH SECTION 11-4.32 OR | | | SERVICE TABLES SHALL BE AVAILABLE. THE HEIGHT AND KNEE | | | CLEARANCES SHALL MEET THE REQUIREMENTS OF 11-4.32.2/ | | | 11-4.32.3 AND 11-4.32.4 | | | | | | 12)106.3.3* PRODUCT APPROVALS- 2004 THOSE PRODUCTS | | | THAT ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. THE PRODUCT | | | APPROVALS SUBMITTED SHALL INDICATE WHICH ITEMS OR | | | SYSTEMS WILL BE USED TO INSTALL THE PRODUCT. THE | | | PRODUCT APPROVALS SHALL BE APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | | | | NOTE: ANY ROOFING WORK WILL REQUIRE A ROOFING | | | CONTRACTOR. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2008-02-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-16 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-16 |
Time |
18:03 |
Sent To |
PC |
|
| Notes |
| 2008-02-16 18:03:16 | ** DENIEDREVISION ** | | | | | | 1) NOTE: PLEASE SEE RISER HAS NOW HAD CONDUCTORS AND | | | CONDUIT REVISED WHICH HAS SEVERAL CODE ISSUESWHICH | | | NEED TO BE ADDRESSED. | | | | | | A) AS REDLINED AND STATED ON ALL PREVIOUS REVIEWS: *AN | | | EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE INSTALLED | | | BEFORE THE FIRST MEANS OF DISCONNECT. PLEASE SEE 250.24 | | | AND 250.6. AS THE CODE REQUIRES THE GROUNDED (NEUTRAL) | | | TO BE BONDED AT THE FIRST MEANS OF DISCONNECT, IF AN | | | EQUIPMENT GROUNDING CONDUCTOR IS INSTALLED FROM THE | | | METER TO THAT FIRST MEANS THIS WOULD PARALLEL THE | | | NEUTRAL AND CREATE OBJECTIONABLE CURRENTS WHICH IS | | | SPECIFICALLY STATED IN THE SECTIONS ABOVE. | | | | | | B) PLEASE SEE THE HOT/PHASE CONDUCTORS HAVE NOW BEEN | | | DOWN SIZED TO 3/0 CONDUCTORS AND STATES PER 310.15B. | | | PLEASE SEE THAT THE SECTION NOTED IS INCORRECT. THE | | | SECTION IS 310.15(B)(6)AND IS STRICTLY FOR | | | *RESIDENTIAL* AND NOT FOR COMMERCIAL USE. | | | THE MINIMUM HOT/PHASE CONDUCTORS FOR THE 225AMP MAINS | | | IN A COMMERCIAL USE PER 310.16 IS 4/0. THIS WAS ON | | | ORIGINAL RISER. | | | | | | C) PLEASE SEE NOW THE CONDUIT SIZE HAS ALSO BEEN | | | DECREASED. PLEASE KNOW AS NOTED IN SECTION B) ABOVE THE | | | CONDUCTORS ARE REQUIRED TO BE 4/0. IF YOU FIGURE THE | | | SIZING PER TABLES IN CHAPTER 9, EVEN USING PVC SCHEDULE | | | 40, OR EMT THE 2INCH CONDUIT IS NOT LARGE ENOUGH FOR | | | THE CONDUCTORS. | | | PLEASE SEE CONDUIT FILL NEEDS TO BE ADDRESSED EVEN IF | | | #4 EQUIPMENT GROUNDING CONDUCTOR AFTER THE FIRST MEANS | | | OF DISCONNECT IS USED. | | | THE 2 ? INCH CONDUIT ON ORIGINAL RISER WAS CORRECT FOR | | | THE CONDUCTORS WHICH WERE SHOWN ON ORIGINAL RISER. | | | THE 2INCH CONDUIT BEFORE THE MAINS ARE OK FOR 4-4/0. | | | | | | D) PLEASE SEE A CODE SECTION OF 250.66 IS REFLECTED ON | | | RISER FOR EQUIPMENT GROUNDS HOWEVER EQUIPMENT GROUNDING | | | CONDUCTORS ARE SIZED FROM 250.122. | | | PLEASE ALSO SEE THE RISER SHOWS 3 #4 EQUIPMENT | | | GROUNDING CONDUCTORS PER CONDUIT?? PLEASE SEE 250.122 | | | AS ONLY ONE EQUIPMENT GROUNDING CONDUCTOR #4 IS | | | REQUIRED FOR UP TO 300AMPS. | | | | | | ** THERE ARE SEVERAL ITEMS WHICH NEED TO BE ADDRESSED. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-08 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-08 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2008-01-08 10:18:38 | *** PROVISO *** | | | | | | ** PLEASE SEE ITEMS FROM PREVIOUS REVIEW ARE STILL IN | | | NEED OF ADDRESSING. | | | | | | | | | | | | 1) NOTE: PLEASE SEE PREVIOUS REVIEW WITH RESPECT TO THE | | | NEW TANK-LESS WATER HEATER. PLEASE SEE THE MANUFACTURES | | | SPECS/CUTS NOW SUBMITTED AS THIS UNIT IS 240V AND THE | | | SERVICE IS 208V. 17250VA AT 208V IS ABOVE THE BRANCH | | | CIRCUIT RATING ON PANEL SCHEDULE. THIS WAS GIVEN ON | | | PREVIOUS REVIEW HOWEVER CIRCUIT WAS NOT ADJUSTED. THE | | | MANUFACTURES SPECS/CUT SHEETS DO STATE 80AMPS FOR THE | | | OVER CURRENT PROTECTION HOWEVER THIS IS AT THE 240V | | | RATING OF THE EQUIPMENT. | | | PLEASE SEE SERVICE IS 208V. | | | PLEASE KNOW AS THIS IS A LISTED ITEM AT 240V IT MAY | | | VERY WELL NOT BE RATED FOR 208V. | | | THESE NEED TO BE ADJUSTED AND VERIFIED. | | | 240.4, 310.16, 110.3, 90.7 | | | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEW COMMENT #6 WHICH | | | MENTIONED THE MISSING EQUIPMENT GROUNDING CONDUCTORS | | | AFTER THE FIRST MEANS OF DISCONNECT. IN FACT THE NOTE | | | GAVE NOTICE THAT THE EQUIPMENT GROUNDING CONDUCTORS ARE | | | *ONLY AFTER THE FIRST MEANS OF DISCONNECT*. | | | PLEASE SEE RISER NOTES/SHOWS THEM BOTH BEFORE AND | | | AFTER. | | | THIS CAN BE RED-LINED FOR NO INSTALLATION OF THESE | | | BEFORE MAINS. (FIRST MEANS OF DISCONNECT). | | | | | | | | | ** PLEASE SUBMIT REVISIONS OR REVISED SPECS/CUT SHEETS | | | BEFORE ROUGH. | | | ** PLEASE BE SURE TO ADDRESS COMMENTS AND IF THERE ARE | | | ANY QUESTIONS, PLEASE CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-30 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-30 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2007-12-30 14:27:21 | | | | *** DENIED REVIEW *** | | | | | | ** PLEASE SEE ITEMS FROM PREVIOUS REVIEW ARE STILL IN | | | NEED OF ADDRESSING. | | | | | | *** IMPORTANT *** | | | IF ALL OTHER REVIEWS PASS AND THERE ARE NO COMMENTS | | | FROM OTHER TRADES A *PROVISO* AND RED-LINED PLANS CAN | | | BE SET UP FOR ELECTRICAL REVIEW FOR THE LAST TWO | | | COMMENTS WHICH WOULD BE REQUIRED TO BE ADDRESSED BEFORE | | | ANY ROUGH ELECTRICAL INSPECTION. | | | | | | 1) NOTE: PLEASE SEE PREVIOUS REVIEW WITH RESPECT TO THE | | | NEW TANK-LESS WATER HEATER. PLEASE SEE THE MANUFACTURES | | | SPECS/CUTS NOW SUBMITTED AS THIS UNIT IS 240V AND THE | | | SERVICE IS 208V. 17250VA AT 208V IS ABOVE THE BRANCH | | | CIRCUIT RATING ON PANEL SCHEDULE. THIS WAS GIVEN ON | | | PREVIOUS REVIEW HOWEVER CIRCUIT WAS NOT ADJUSTED. THE | | | MANUFACTURES SPECS/CUT SHEETS DO STATE 80AMPS FOR THE | | | OVER CURRENT PROTECTION HOWEVER THIS IS AT THE 240V | | | RATING OF THE EQUIPMENT. | | | PLEASE SEE SERVICE IS 208V. | | | PLEASE KNOW AS THIS IS A LISTED ITEM AT 240V IT MAY | | | VERY WELL NOT BE RATED FOR 208V. | | | THESE NEED TO BE ADJUSTED AND VERIFIED. | | | 240.4, 310.16, 110.3, 90.7 | | | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEW COMMENT #6 WHICH | | | MENTIONED THE MISSING EQUIPMENT GROUNDING CONDUCTORS | | | AFTER THE FIRST MEANS OF DISCONNECT. IN FACT THE NOTE | | | GAVE NOTICE THAT THE EQUIPMENT GROUNDING CONDUCTORS ARE | | | *ONLY AFTER THE FIRST MEANS OF DISCONNECT*. | | | PLEASE SEE RISER NOTES/SHOWS THEM BOTH BEFORE AND | | | AFTER. | | | THIS CAN BE RED-LINED FOR NO INSTALLATION OF THESE | | | BEFORE MAINS. (FIRST MEANS OF DISCONNECT). | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS AND IF THERE ARE | | | ANY QUESTIONS, PLEASE CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-12-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-06 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-06 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2007-12-06 15:31:26 | ** DENIED 3RD REVIEW ** | | | | | | ** PLEASE SEE COMMENTS FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH NEW COMMENTS BASED ON | | | CHANGES MADE AND NEW ITEMS NOT ON PREVIOUS PLANS. SOME | | | OTHER ITEMS ARE ONLY NOW BEING SUBMITTED FOR THE FIRST | | | REVIEW. | | | | | | 1) NOTE: PLEASE SEE THE METHOD ON HOW LIGHTING | | | PERFORMANCE CALCULATIONS ARE DONE WAS SUBMITTED HOWEVER | | | ACTUAL LIGHTING PERFORMANCE CALCULATIONS ARE SHOWN. | | | 13-415.2 | | | | | | 2) NOTE: PLEASE SEE THE CIRCUITING IS NOW SHOWN, | | | HOWEVER PLEASE SEE THE CIRCUITING FOR EMERGENCY AND | | | EXIT LIGHTS ARE NOT PER 700.12F WHICH REQUIRES THE | | | FIXTURES TO BE CIRCUITED TO THE LOCAL LIGHTING IN ANY | | | ONE AREA. | | | FOR EXAMPLE: IF THE BREAKER FOR THE NORMAL LIGHTING IN | | | THE BATHROOMS WERE TO TRIP, THE EMERGENCY LIGHT WOULD | | | NOT ILLUMINATE. | | | PLEASE SEE NFPA-101 7.9.2.2 | | | | | | 3) NOTE: PLEASE SEE THE PANEL SCHEDULE *C* NOW SHOWS A | | | NEW TANK-LESS WATER HEATER AT 17250 WATTS, YET THE OVER | | | CURRENT PROTECTION IS TOO LOW BASED ON THE KW AND | | | VOLTAGE AS SHOWN. | | | PLEASE PROVIDE MANUFACTURE CUT SHEET WHICH INDICATES A | | | LISTING FROM A NRTL. | | | 90.7, 110.3 | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE THE NEW PANEL SCHEDULES SUBMITTED | | | ALONG WITH LOAD CALCULATIONS HAVE BEEN CHANGED AND | | | THERE ARE ITEMS WHICH CAN NOT BE SEEN. | | | THE PRINT IS VERY FAINT IN LOCATIONS FOR MANY ITEMS. | | | PLEASE SEE THE TITLE AT THE TOP OF THE PANEL WHICH SHOW | | | LOAD. THIS CAN NOT BE FIGURED AT THIS TIME. | | | PLEASE SEE THE PREVIOUS PANEL SCHEDULE SHOWS THE LOAD | | | FOR THE TANK-LESS WATER HEATER NOTED ABOVE AS WHAT | | | APPEARS TO BE 8KW, YET CALCULATIONS DO NOT SHOW THE | | | SAME?? | | | PLEASE SEE THE PANEL SCHEDULE ALSO DOES NOT SHOW ANY | | | CONDUCTOR SIZES FOR BRANCH CIRCUITS. 240.4,408.4,310.16 | | | ETC | | | PLEASE SEE NEC 220 FOR LOAD CALCULATIONS AND | | | ADJUSTMENTS NEED. | | | HOW ARE LOADS DERIVED? PLEASE CLARIFY LOADS ON | | | CALCULATIONS DO NOT SEEM TO CORRELATE WITH PANEL. FOR | | | EXAMPLE: PLEASE SEE AHU LOADS ON PANEL, WHICH ARE NOT | | | THE SAME ON CALCULATIONS. THIS IS THE SAME AS TANK-LESS | | | WATER HEATER. | | | THESE ARE A COUPLE OF EXAMPLES. | | | PLEASE GO OVER ALL AND MAKE ADJUSTMENTS. | | | | | | 5) NOTE: PLEASE SEE THE RISER NOW HAS SOME OF THE | | | SERVICE ENTRANCE CONDUCTORS AND FEEDERS SHOWN HOWEVER | | | THE SIZES OF THESE CONDUCTORS ARE NOT RATED FOR THE | | | OVER CURRENT PROTECTION. | | | PLEASE KNOW THIS IS A COMMERCIAL BUILDING AND THE | | | DE-RATINGS PERMITTED IN 310.15B6 MAY NOT BE USED. | | | PLEASE SEE PREVIOUS NOTES MENTIONED THESE WERE NOT | | | LARGE ENOUGH BASED ON 310.16, 240.4 AND 110.14 3/0'S | | | ARE ONLY RATED FOR 200AMPS, YET THE MAINS ARE 225AMPS. | | | PLEASE ADJUST CONDUCTORS ON BOTH SIDES OF MAIN | | | DISCONNECTS. | | | | | | 6) NOTE: PLEASE SEE RISER IS MISSING EQUIPMENT | | | GROUNDING CONDUCTORS AFTER THE FIRST MEANS OF | | | DISCONNECT PER 250.110, 250.24, 250.122. | | | PLEASE INCLUDE ONLY AFTER THE FIRST MEANS OF | | | DISCONNECT. | | | | | | 7) NOTE: PLEASE CORRELATE AND GO OVER ALL CIRCUITING AS | | | SHOWN. | | | PLEASE SEE FOR EXAMPLE, THE LIGHTING AND POWER PLANS | | | INDICATE CIRCUIT CHP-29 FOR SOME LIGHTS OUTSIDE AND | | | POWER PLANS SHOWS THIS SAME CIRCUIT FEEDING SOME | | | RECEPTACLES, HOWEVER THE PANEL SCHEDULE MENTIONS THIS | | | CIRCUIT IS FOR *RAMP LIGHTS*. | | | WHERE ARE THE * RAMP LIGHTS* ? | | | PLEASE COORDINATE CIRCUITING AS NOTED ABOVE FOR | | | EMERGENCY LIGHTING AND OTHER ITEMS ON PLANS. 408.4, | | | 310.16, 240.4 | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-07 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-07 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2007-11-07 15:24:01 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE THERE ARE COMMENTS FROM PREVIOUS REVIEW | | | AND SEVERAL NEW COMMENTS DUE TO NEW INFORMATION/DETAILS | | | NOW ON PLANS WHICH HAVE CREATED NEW COMMENTS. | | | | | | 1) NOTE: PLEASE SEE THAT NO LIGHTING ENERGY/PERFORMANCE | | | CALCULATIONS WERE SUBMITTED. | | | PLEASE SEE 13-101.1.3, 13-415.2 | | | (PREVIOUS REVIEW ) | | | | | | 2) NOTE: PLEASE SEE MISSING ADA LEVELS FOR FA DEVICES. | | | PLEASE SEE FBC 11-4.28.1, .2 AND .3(4). | | | DEVICE LOCATIONS ARE SHOWN HOWEVER NO MINIMUM LEVELS | | | COULD BE LOCATED. | | | | | | 3) NOTE: PLEASE SEE THE ELECTRICAL SERVICE RISER IS IN | | | NEED OF CHANGES. | | | PLEASE SEE NO SERVICE ENTRANCE CONDUCTORS ARE SHOWN. | | | CAN NOT DETERMINE OR REVIEW AMPACITY OF CONDUCTORS AT | | | THIS TIME AS NONE ARE SHOWN. | | | PLEASE SEE THE CONDUCTORS FROM METER TO MAIN AND MAIN | | | TO PANELS ARE NOT OF SUFFICIENT SIZE. PLEASE ALSO SEE | | | THAT THE NUMBER OF CONDUCTORS IS NOT SHOWN. | | | PLEASE SEE NEC 240.4, 310.16. | | | | | | 4) NOTE: PLEASE SEEM MISSING COLD WATER PIPE FOR | | | GROUNDING ELECTRODE SYSTEM 250.50 | | | | | | 5) NOTE: PLEASE SEE THE LOAD CALCULATIONS SUBMITTED ARE | | | FOR A RESIDENTIAL DWELLING. | | | PLEASE SEE NEC 220, 220.12,220.14, 220.42, 220.44, ETC | | | PLEASE SEE THAT ALL CONTINUOUS LOADS ARE TO BE SHOWN AT | | | 125%. 215.3, 230.42 | | | | | | 6) NOTE: PLEASE COMPLETE ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH THE SUBMITTED PANEL SCHEDULES. PLEASE | | | SEE THERE ARE ELECTRICAL ITEMS ON PLANS WHICH ONLY | | | CONTAIN PART OF THE NUMERICAL CIRCUIT DESIGNATION. | | | (EXAMPLE ICE MACHINE). | | | PLEASE THERE ARE SEVERAL ELECTRICAL RECEPTACLE | | | LOCATIONS WHICH DO NOT INDICATE ANY CIRCUITS. | | | PLEASE SEE AS THE ELECTRICAL DISCONNECTS FOR A/C RT | | | UNITS ARE NOT SHOWN ON ELECTRICAL PLANS PLEASE INDICATE | | | CIRCUITS. | | | FBC 106.3.5.1.2, 106.1.2 | | | NEC 408.4. | | | | | | 7) NOTE: PLEASE CLARIFY THE SAME CLEARANCE REQUIREMENTS | | | FOR THE PANELS. ONE DETAIL ON SHEET 24, INDICATES | | | MINIMUM CLEARANCES HOWEVER THERE IS ONE DETAIL WHICH | | | SHOWS AN ELEVATION OF A COUNTER IN FRONT OF PANELS | | | WHICH IS NOT PERMITTED. ONE OTHER DETAIL SHOWS A JOG IN | | | COUNTER AND ANOTHER DETAIL DOES NOT. | | | | | | 8) NOTE: PLEASE SEE DETAILS FOR FLOOR TILE LIGHTS WHERE | | | THE CONNECTION DETAILS AS SHOWN DO NOT COMPLY WITH | | | MANUFACTURES INSTALLATION OR WITH APPROVED CONNECTORS | | | FOR USE. *SEAL-TITE* CONNECTORS ARE NOT FOR USE WITH | | | THESE CABLES ARE MENTIONED. | | | PLEASE KNOW THAT ALL INSTALLATIONS SHALL MEET NEC 300, | | | 110.3 ETC. | | | THE DETAIL AS SHOWN AND AS PREVIOUSLY SPOKE ABOUT IS | | | STILL NOT APPROVED AS SHOWN. | | | | | | 9) NOTE: PLEASE SEE FS 553.80(2)(B) WIHT RESPECT TOP | | | REPEAT COMMENTS. THIS IS ONLY A NOTICE GIVEN AT THIS | | | TIME. | | | | | | ** PLEASE SEE THERE ARE SEVERAL CHANGES NEEDED AND | | | ITEMS WHICH CAN NOT BE REVIEWED. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-25 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-25 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2007-09-25 12:36:04 | ** DENIED** | | | | | | | | | | | | 1) NOTE: PLEASE STATE THE FOLLOWING RELEVANT CODES ON | | | PLANS. | | | PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH ARE | | | SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | ** PLEASE SEE THE TOP OF397-001-C2 WHICH PRINTED THE | | | LS CODE A EDITION 200. THIS SEEMS TO HAVE BEEN A | | | MISPRINT. | | | | | | ** PLEASE SEE PLANS ALSO CALL FOR *PALM BEACH COUNTY | | | AMENDMENTS* HOWEVER THIS PROJECT IS NOT LOCATED IN PALM | | | BEACH COUNTY JURISDICTION. THIS IS LOCATED IN THE CITY | | | OF WEST PALM BEACH. | | | | | | 2) NOTE: PLEASE SEE THE INFORMATION SHOWN ON TITLE | | | BLOCKS FOR THE ENGINEERING FIRM IS IN A DELINQUENT | | | STATUS WITH THE DEPARTMENT OF BUSINESS AND PROFESSIONAL | | | REGUALTION. | | | PLEASE UPDATE. | | | FS 471.023 | | | | | | 3) NOTE: PLEASE SEE FLORIDA STATUTES 471.025 AS THIS | | | AND THE FLORIDA ADMINISTRATIVE CODE 61G15-23.002 WHICH | | | REQUIRES PLANS TO BE SIGNED, DATED AND SEALED BY THE | | | DESIGN PROFESSIONAL. | | | PLEASE SEE SOME SHEETS CONTAIN SEAL BUT NO SIGNATURE | | | AND DATE, MOST SHEETS ARE NOT DATED AS REQUIRED. | | | ** PLEASE KNOW THIS IS REQUIRED FOR ALL TRADES AND FOR | | | ALL SHEETS WHETHER OR NOT COMMENT IS MADE BY OTHER | | | TRADES. | | | | | | 4) NOTE: PLEASE SEE PLANS DOE NOT INDICATE ANY | | | EMERGENCY AND EXIT LIGHTS AS REQUIRED PER FBC CHAPTER | | | 10, AND NFPA-101 7.8, 7.9. | | | PLEASE SEE 700.12F OF NFPA-70 FOR CIRCUITING REQUIRED. | | | PLEASE KNOW THE BATHROOMS WHEN CONTAINING PARTITIONS | | | AND NOT A SINGLE POINT OF USE WILL REQUIRE AN EMERGENCY | | | BATTERY BACK UP FIXTURE OF SOME SORT. | | | ** PLEASE SEE POSSIBLE COMMENTS FROM THE FIRE MARSHAL. | | | | | | 5) NOTE: PLEASE SEE MISSING SIGN CIRCUIT PER 600.5 AND | | | LOAD FOR THIS SAME SIGN CIRCUIT. | | | | | | 6) NOTE: PLEASE SHOW AND COMPLETE LOCATIONS OF ALL A/C | | | SYSTEMS ON ELECTRICAL PLANS. | | | IT IS BEING ASSUMED THESE UNITS ARE ROOFTOP PACKAGE | | | UNITS ALTHOUGH THE MECHANICAL PLANS ARE NOT CLEAR. | | | PLEASE SEE MISSING REQUIRED DISCONNECTS PER 440.11 AND | | | MISSING GFI RECEPTACLES PER 210.63 AND 210.8B. | | | | | | 7) NOTE: PLEASE SEE THE RISER INDICATES MAIN AHEAD OF | | | PANELS HOWEVER THE PLANS DO NOT INDICATE THESE FOR | | | THEIR LOCATIONS. | | | PLEASE KNOW THE SERVICE DISCONNECTING MEANS IS NOT | | | COMPLETE AT THIS TIME ON PLANS. | | | PLEASE KNOW THE LOCATION OF THE SERVICE DISCONNECTING | | | MEANS NEEDS TO BE DETERMINED FOR LOCATION. | | | PLEASE SEE NOTE BELOW WITH RESPECT TO THE PANEL | | | LOCATIONS WHICH DOES NOT MEET CODE. | | | 230.70, 230.71, 110.26 | | | | | | 8) NOTE: PLEASE SEE THE RISER IS NOT COMPLETE WITH THE | | | SERVICE ENTRANCE CONDUCTORS, CONDUCTORS TO MAINS, | | | CONDUCTORS FROM MAINS TO PANELS ETC. | | | 240.4, 310.16 ETC | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 9) NOTE: PLEASE SEE MISSING COMPLETED GROUNDING | | | ELECTRODE SYSTEM PER 250.50. PLEASE KNOW THAT QUOTING | | | THE CODE IN LIEU OF THE REQUIRED MINIMUM DETAIL IS NOT | | | ACCEPTABLE. | | | PLEASE ADJUST RISER. | | | PLEASE ALSO SEE THAT THE SIZE OF THE GROUNDING | | | ELECTRODE CONDUCTOR IS NOT LARGE ENOUGH AND NEEDS TO | | | MEET THE MINIMUM SIZES PER 250.66. | | | | | | 10) NOTE: PLEASE SEE THE LOCATION OF THE PANEL(S) IN DJ | | | BOOTH AREA DOES NOT MEET 110.26. IN FACT THERE IS A | | | COUNTER BEING SHOWN DIRECTLY IN FRONT OF ONE OF THE | | | PANELS WHICH IS STRICTLY PROHIBITED. | | | PLEASE SEE NOTES ABOVE WITH RESPECT TO SERVICE, PANELS, | | | OVER CURRENT PROTECTION AND LOCATIONS OF ALL SERVICE | | | EQUIPMENT AND PANELS. | | | PLEASE ADJUST AS REQUIRED. | | | | | | 11) NOTE: PLEASE CORRELATE RISER DIAGRAM AND PANELS. | | | PLEASE SEE PANEL CH IS SHOWN AS 225AMP AND ALSO AS | | | 200AMP ON PANEL SCHEDULE. | | | FBC 106.1.2 FOR COORDINATION. | | | | | | 12) NOTE: PLEASE PROVIDE AIC RATINGS FOR ALL SERVICE | | | EQUIPMENT INCLUDING MAINS PER 110.9. | | | FBC 106.1.2 | | | | | | 13)NOTE: PLEASE SEE NO ENERGY CALCULATIONS WERE | | | SUBMITTED. IF INSTALLING NEW AIR CONDITIONED SPACE, | | | THEN THESE WILL BE REQUIRED. IF NO NEW A/C EQUIPMENT IS | | | BEING INSTALLED, THEN PLEASE SUBMIT LIGHTING | | | PERFORMANCE CALCULATIONS PER 13-415.2 | | | | | | 14) NOTE: PLEASE SEE THERE ARE SEVERAL CIRCUITS IN | | | WHICH THE KVA LOAD SHOWN FAR EXCEEDS THE RATING OF THE | | | BRANCH CIRCUIT AND BRANCH CIRCUIT OVER CURRENT | | | PROTECTION. | | | PLEASE SEE FOR EXAMPLE 3.2 KVA ON SINGLE POLE 20AMP | | | BRANCH CIRCUIT.(MAX 1920VA) | | | PLEASE SEE THAT ALL CONTINUOUS LOADS ARE TO BE SHOWN AT | | | 125%. | | | PLEASE SEE 215.3, 230.42, 408.4, 240.4, 310.16 ETC | | | PLEASE BE SURE TO ADJUST PANEL SCHEDULE FOR CIRCUITING | | | AND LOADS. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 15) NOTE: PLEASE CORRELATE ALL CIRCUITING ON PLANS WITH | | | PANEL SCHEDULES. PLEASE SEE FOR EXAMPLE CIRCUITS: CHP-5 | | | ON PLANS, YET THIS IS CHP-5,7 ON PANEL SCHEDULE. CHP-3 | | | ON PLANS, YET PANEL SCHEDULE INDICATES THIS AS ONE OF | | | THE AIR HANDLERS. PLANS DO NOT INDICATE THE AIR HANDLER | | | UNDER THE BAR. | | | PLEASE CORRELATE ALL AND ADJUST CIRCUITS TO ALL AREAS, | | | EQUIPMENT AND SPECIFIC ROOMS. | | | PLEASE SEE 2-POLE CIRCUITS ON PANELS YET SHOWN AS | | | SINGLE POLE CIRCUITS ON PLANS. | | | PLEASE SEE 408.4, 310.16, 240.4 AS CIRCUITS, | | | CONDUCTORS, LOADS ETC NEED TO BE VERIFIED AND CAN NOT | | | BE DONE AT THIS TIME. | | | | | | 16) NOTE: PLEASE SUBMIT COMPLETED LOAD CALCULATIONS PER | | | NEC 220. | | | PLEASE SEE 220.12, 220.14, 220.42, 220.44 FOR EXAMPLE. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 17) NOTE: PLEASE SEE PLANS MENTIONS THERE WILL BE A | | | FIRE ALARM PANEL AND DEVICES BEING SUBMITTED AND DONE | | | UNDER A SEPARATE PERMIT. THIS IS OK, HOWEVER PLEASE | | | KNOW THE MINIMUM LOCATIONS AND LEVELS FOR ADA | | | COMPLIANCE PER FBC CHAPTER 11 IS REQUIRED TO BE SHOWN | | | ON THE BASE PLANS FOR MINIMUM DESIGN INTENT. | | | PLEASE SE E11-4.28, .1, .2 AND .3(4). | | | | | | 18) NOTE: PLEASE CORRELATE THE ELECTRICAL EQUIPMENT | | | SCHEDULE AND PANEL SCHEDULE(S). | | | FOR EXAMPLE PLEASE SEE THE DISHWASHER WHICH IS SHOWN AS | | | 208, 40MP AND 208/50AMP. | | | | | | 19) NOTE: PLEASE KNOW AS FOR INFORMATIONAL PURPOSE | | | ONLY. ALL LOW VOLTAGE SYSTEMS SUCH AS PHONE, CATV, AND | | | DATA ETC ARE REQUIRED TO BE UNDER SEPARATE PERMITS. | | | THE PLANS MAY CONTAIN THIS LOW VOLTAGE INFORMATION AND | | | ANY LV PERMIT APPLICATIONS MAY REFERENCE THE BASE PLANS | | | ONCE ISSUED FOR PERMIT. | | | ANY LOW VOLTAGE NOT INCLUDED ON BASE BUILD OUT PLANS | | | WILL REQUIRE SEPARATE PLANS. | | | IF THERE ARE ANY QUESTIONS ON THIS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS REVIEWER. | | | | | | 20) NOTE: PLEASE KNOW AS THERE ARE SEVERAL ITEMS WHICH | | | ARE NOT ON PLANS AT THIS TIME OR NEED TO BE REVISED OR | | | CHANGED, THERE MAY BE NEW COMMENTS ON THE FOLLOWING | | | REVIEW WHICH CAN NOT BE MADE AT THIS TIM. | | | | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-01-07 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-07 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2008-01-07 11:22:02 | PLANS WERE PASSED ON 12/24/07. NEW FP, FA AND LIFE | | | SAFETY SHEETS STAMPED, SIGNED AND DATED ON THIS DATE. | | | IN ADDITION TO CUT SHEETS AND CALCULATIONS, PLEASE | | | SUBMIT INFORMATION FOR DOUBLE DETECTOR CHECK ASSEMBLY | | | WHEN SUBMITTING FOR FIRE SPRINKLER PERMIT. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-24 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-24 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2007-12-24 14:36:25 | ******APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;HOWEVER THE APPROPIATE PLAN SHEETS TO | | | BE FIRE-STAMPED WHEN THE OTHER PLAN REVIEWS HAVE BEEN | | | SATISFIED. | | | | | | | | | CAPT MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-20 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2007-11-20 12:52:33 | ******UNSAT***** | | | | | | *OLD COMMENTS:THE FOLLOWING COMMENTS FROM THE | | | PREVIOUS FIRE PLAN REVIEW COMMENT STILL NEED TO BE | | | ADDRESSED. | | | | | | 10.ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN | | | AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS | | | SHALL BE PROVIDED WITH PANIC HARDWARE OR FIRE EXIT | | | HARDWARE. | | | | | | 11.PROVIDE PRESCRITIVE STRENGHT AND SPECIFICATIONS | | | FOR THE HANDRAILS. | | | | | | *NEW COMMENT: | | | | | | AA.KNOX LOCKING CAPS REQUIRED FOR THE FIRE DEPARTMENT | | | CONNECTION.FOR AN APPLICATION, CONTACT WEST PALM | | | BEACH FIRE PREVENTION BUREAU AT 561-805-6722. | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-11 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-11 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2007-10-11 11:43:32 | ******DENIED***** | | | | | | | | | 01.ON THE SHEET TITLED GENERAL NOTES & LEGEND | | | (DRAWING NUMBER 397-001-C2) UNDER BUILDING DESIGN DATA, | | | AN INCORRECT/MISPRINT REFERENCE TO NFPA 101(200 | | | EDITION) IS LISTED.AS LISTED IN THE APPLICABLE CODES | | | OF THE SAME SHEET, THE 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 02.THE NUMERICAL ADDRESS OF THE PROJECT SITE SHALL BE | | | IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 03.ALL STRUCTURES UNDERGOING CONSTRUCTION, | | | ALTERATION, OR DEMOLITION OPERATIONS SHALL COMPLY WITH | | | NFPA 241. | | | | | | 04.THE DEMOLITION AND/OR THE CONSTRUCTION OPERATIONS | | | SHALL NOT INTERFERE OR HINDER EMERGENCY RESPONSE ACCESS | | | TO THE PROPERTY OR VICINITY THEREOF (INCLUDING STREETS, | | | ALLEYS, FIRE LANES) . | | | | | | 05.PROVIDE TEMPORARY ADDRESS NUMBERS IF THE | | | DEMOLITION EXTERIOR ELEVATION OPERATION HAS CAUSE FOR | | | THE EXISTING ADRRESS TO BE REMOVED. | | | | | | 06.ON THE NEW NITECLUB FRONT ELEVATION, SHOW/DISPLAY | | | THE NUMERICAL ADDRESS ON THE BUILDING (NOT DOOR) TO BE | | | VISIBLE FROM SOUTH NARCISSUS AVENUE.HURRICANE | | | SHUTTERS SHALL NOT BE PERMITTED TO COVER OR CONCEAL | | | ADDRESSES. | | | | | | 07.PROVIDE A LIFE SAFETY PLAN SHEET WHICH ILLUSTRATES | | | TRAVEL DISTANCE TO THE EXITS.EXIT LIGHTS, EMERGENCY | | | LIGHTS, AND FIRE EXTINGUISHER(S) MAY ALSO BE INCLUDED | | | ON THIS PLAN SHEET. | | | | | | 08.NO EXIT LIGHTS AND EMERGENCY LIGHTS SHOWN IN THE | | | REFLECTED CEILING LIGHTING PLAN. | | | | | | 09.MEANS OF EGRESS FROM A ROOM OR SPACESHALL NOT BE | | | PREMITTED THROUGH KITCHENS, STOREROOMS, RESTROOMS, | | | CLOSETS, STAGES, DJ BOOTHS, OR HAZARDOUS AREAS. | | | | | | 10.ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN | | | AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS | | | SHALL BE PROVIDED WITH PANIC HARDWARE OR FIRE EXIT | | | HARDWARE. | | | | | | 11.PROVIDE PRESCRITIVE STRENGHT AND SPECIFICATIONS | | | FOR THE HANDRAILS. | | | | | | 12.PROVIDE SPECIFIATIONS OR DETAILS OF THE ADA RAMP. | | | | | | 13.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | MATERIAL FOR THE EXITS, EXIT AISLE CORRIDORS, AND ALL | | | OTHER SPACES IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 14.SPECIFY THE INTERIOR FLOOR FINISH IN TERMS OF | | | CLASS I OR CLASS II. | | | | | | 15.FIRE ALARM SYSTEM TO BE CLASS A OR FULLY | | | ADDRESSABLE, MONITORED, AND SHALL BE UL CERTIFICATED | | | FOR CENTRAL STATION. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-11 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-11 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2008-04-11 14:08:45 | TO "COMM" BD#18 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-22 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-22 |
Time |
12:15 |
Sent To |
B |
|
| Notes |
| 2008-01-22 12:17:18 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-28 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-28 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2007-12-28 15:29:12 | TO COMM BOARD # 40 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-30 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-30 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2007-12-03 08:47:39 | TO "COMM" BD#45 | | 2007-11-30 16:34:54 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-25 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-25 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2007-10-30 14:46:58 | TO "BOB"#14 | | 2007-10-25 11:12:02 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-11 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-06 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2007-09-24 09:54:00 | TO "BOB"#1 | | 2007-09-06 16:54:48 | WAITING FOR "BOB"--OK TO ROUTE TO "BOB" PER "RBROWN" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-14 |
Time |
12:21 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-14 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2008-04-14 12:22:20 | REVISION TO MECH. PLAN 397-001-C19. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-31 |
Time |
11:30 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-12-31 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2007-12-31 11:38:40 | *** PROVISO *** | | | 1) OUTSIDE AIR INTAKE SHALL BE A MINIMUM OF 10 FEET | | | FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS | | | VENTS, CHIMNEYS, PLUMBING VENTS, ETC., SEE 2004 FBC/M | | | 401.5.1. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-05 |
Time |
14:45 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2007-12-05 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-08 |
Time |
08:12 |
Rev Time |
2.30 |
| Received By |
tgordon |
Date |
2007-11-08 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2007-11-08 10:27:51 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) SEE PLANS PAGE C19A SHOWS THREE 8" DIA. GRAVITY | | | EXHAUSTS, PAGE C19 SHOWS ONLY TWO BATHROOM EXHAUST | | | FANS, PLEASE EXPLAIN OR CORRECT. | | | | | | 2) PAGE C19A IS STATING GRAVITY EXHAUST. PAGE C19 FAN | | | SCHEDULE SHOWS ELECTRICAL EXHAUST FANS, PLEASE EXPLAIN | | | OR CORRECT. | | | | | | 3) PAGE C19 FAN SCHEDULE SHOWS TWO EXHAUST FANS EACH AT | | | 405 CFM'S WITH A 4" DUCT, THAT WOULD PUT THE AIR | | | VELOCITY AROUND 4,600 FPM. PLEASE SUBMIT DETAILED | | | MANUFACTURER'S SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR BATHROOM EXHAUST FANS. | | | | | | 4) HVAC SCHEDULE SHOW THE HEATERS AT 150 BTUH THAT | | | WOULD BE ABOUT 0.04 KW, ELECTRICAL PLANS SHOW THE | | | HEATERS AT 12 KW. PLEASE CORRECT. | | | | | | 5) PAGE C19 SHOWS THE SPACE ABOVE THE LAVATORIES IS AN | | | OPEN PLENUM. PLEASE ADD A NOTE THAT STATES NO | | | COMBUSTIBLE MATERIALS PERMITTED IN PLENUM, TO COMPLY | | | WITH 2004 FBC/M 602.2.1. AND NO EXHAUST DUCTS UNDER | | | POSITIVE PRESSURE, CHIMNEYS,OR VENTS PERMITTED IN | | | PLENUM, TO COMPLY WITH 2004 FBC/M 601.3. | | | | | | 6) PAGE C19 SHOWS THREE FLEX DUCTS, PLEASE SHOW SIZE OF | | | FLEX, SEE 2004 FBC 106.3.5. | | | | | | 7) PAGE C19 LEGEND SHOWS THE SYMBOL FOR AN EXHAUST FAN, | | | SEE SYMBOLS IN BATHROOMS ARE SHOWING AS RETURN GRILLS. | | | PLEASE CORRECT. | | | | | | 8) SEE PAGE C19 MAKEUP AIR VENTILATION RATE. DO YOU | | | MEAN OUTDOOR AIR? SEE 2004 FBC/M CH. 2 DEFINITIONS. | | | | | | 9) MAKEUP AIR CALCULATIONS (OUTDOOR AIR ?) SHOWS 6000 | | | CFM AND 810 CFM BEING EXHAUSTED AT BATHROOMS = 5,190 | | | CFM OF POSITIVE PRESSURE. SEE 2004 FBC/M 403.1 | | | VENTILATION SYSTEM. | | | MECHANICAL VENTILATION SHALL BE PROVIDED BY A METHOD OF | | | SUPPLY AIR AND RETURN OR EXHAUST AIR. THE AMOUNT OF | | | SUPPLY AIR SHALL BE APPROXIMATELY EQUAL TO THE AMOUNT | | | OF RETURN AND EXHAUST AIR. IF OUTDOOR AIR CALCULATIONS | | | WERE DONE BY ASHRAE 62.1 STANDARD THE BUILDING WOULD | | | NOT BE AT SUCH A POSITIVE PRESSURE. PLEASE LOOK INTO. | | | SEE 2004 FBC/M 403.4. | | | | | | 10) PAGE C19 SHOWS A LARGE 72" X 32" GRILL, SEE YELLOW | | | HIGH LIGHT ON PLAN. PLEASE EXPLAIN OR CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-24 |
Time |
11:49 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-09-24 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2007-09-24 12:17:03 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLEASE REMOVE THE ROOF FRAMING LAY-OUT FROM THE | | | MECHANICAL PLAN PAGE 397-001-C19, AS IT CAN NOT BE READ | | | AT THIS TIME. | | | | | | 2) PLEASE SUBMIT A MECHANICAL PLAN THAT SHOW THE | | | LOCATION OF THE EXISTING A/C UNITS AND ANY NEW UNITS. | | | SHOW ALL NEW AND EXISTING SUPPLY AND RETURN AIR DUCTS. | | | STATE WHAT IS NEW AND EXISTING ON PLAN. | | | | | | 3) SHOW BATHROOM EXHAUST FANS AND CFM'S ON MECHANICAL | | | PLAN, SEE FBC/M 403.3. | | | | | | 4) MECHANICAL PLAN SHOWS A RETURN AIR DUCT IN THE | | | BATHROOM, RETURN AIR GRILLS ARE NOT PERMITTED IN | | | RESTROOM, SEE FBC/M 407.1. PLEASE CORRECT. | | | | | | 5) THERE ARE TWO HVAC SCHEDULES ON THE MECHANICAL PLAN, | | | PLEASE EXPLAIN OR CORRECT. | | | | | | 6) SHOW OUTDOOR AIR CALCULATIONS ON MECHANICAL PLAN, | | | SEE FBC/M 401.2. | | | | | | 7)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, SEE F.B.C. 106.1.1. | | | | | | 8) THE CERTIFICATE OF AUTH. FOR YOUCHAK & YOUCHAK IS | | | DELINQUENT, PLEASE CORRECT. | | | | | | 9) WHEN SIGNING AND SEALING PLANS THE DATE MUST ALSO | | | APPEAR, SEE FAC 61G15-23.002. PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-17 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-16 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2008-04-17 09:16:25 | PLUMBING REVISIONS SHT'S 20A, 20C AND NEW SHEET 32 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-08 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-08 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2008-01-08 08:38:12 | PROVISO; | | | 703.4 EXISTING DRAIN AND SEWER INTEGRITY. | | | 708.3.5 CLEANOUTS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-21 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-19 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2007-12-21 09:20:48 | DENIED; | | | FROM OLD PLAN REVIEW; | | | 1. OK | | | 2. NO. MINUMUM PLUMBING FIXTURES TABLE 403.1 (A-2) THE | | | TOP TABLE SHOULD BE USED IN THIS SECTION, THIS IS A | | | NIGHTCLUB/BAR. NO KITCHEN TO PREPARE FOOD. 4-TOILETS | | | ARE REQUIRED IN EACH BATHROOM, 1/40. | | | 3. YES | | | 4. NO NOTE ABOUT DRY VENT TO BE WASHED IS NOT THE | | | ANSURE VENTS ARE STILL SHOWN IN AN AREA WHERE NO | | | FIXTURE WILL WASH THEM. | | | | | | 5. NO VENTING OF THE SANITARY SYSTEM IS STILL NOT | | | CORRECT. I.E. NO VENTSHOWN ON SANITARY RISER DIAGRAM | | | BACK BAR. VENTS IN BATHROOMS SHOULD | | | COME FROM THE FIXTURES, NOT OF THE BRANCH DRAINS. | | | (EXSTEND URINAL PIPE INTO A VENT. | | | 6. YES | | | NEW COMMENTS | | | 1. RISER DIAGRAMS ARE VERY HARD TO FOLLOW. FBC BUILDING | | | CHAPTER 1 WPB ADMINISTRATION SECTION 106.1.1. PLEASE | | | DELETE THE OUTLINES OF THE EQUIPMENT, CEILING AND | | | FLOOR. INDIRECT WASTE LINES LOOK LIKE THERE TIED INTO | | | THE SANITARY SYSTEM, I.E. DISH WASHERS, SEE FBC | | | PLUMBING SECTION 802.2. | | | 2. DRINKING FOUNTAIN IS NOT PERMITED TO BE IN A | | | BATHROOM. PLUMBING SECTION 410.2. ALSO DRINKING | | | FOUNTAIN IS REQUIRED TO MEAT THE ACCESSIBILITY CODE | | | SECTIONS 11-4.15.1 THRU 11-4.15.5. SHOW DETAIL ON | | | PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-17 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-17 |
Time |
06:21 |
Sent To |
|
|
| Notes |
| 2007-11-17 08:25:23 | DENIED; | | | 1. OLD COMMENT 2F; (NO) FLOOR DRAINS ARE STILL SHOWN ON | | | SANITARY RISER DIAGRAM. ALL INDIRECT WASTES SHALL GO TO | | | AAPPROVED WASTE RECEPTOR AS DISCRIBED IN FBC-PLUMBING | | | SECTION 802.3. | | | NEW COMMENTS; | | | 2.TABLE 403.1(A-2) MIN. FIXTURE REQUIREMENTS HAS NOT | | | BEEN MET. WOMANS ROOM REQUIRES 3 TOILETS, AND A | | | DRINKING FOUNTAIN IS ALSO REQUIRED. | | | 3. WATER SERVICE IS NOT LARGE ENOUGH. SEE TABLE 603.1. | | | SHOW CALCULATIONS. | | | 4. SANITARY RISER DIAGRAM; HORIZONTAL DRY VENTS ARE NOT | | | PERMITED, SEE SECTION 905.3. (HI-LIGHTED) ON ONE SET OF | | | PLANS. | | | (A) THE 4" A.A.V.SHALL BE UPSTREAM OF THE | | | FIXTURE GROUP (BAR) SEE SECTION 909.1, WET VENT. | | | 5. PLUMBING FIXTURELIST;ARE ALL TOILETS HANDICAP | | | HIGHT? | | | 6. WATER RISER DIAGRAM; HOT WATER TO THE HAND SINKS AND | | | LAVATORY'S SHOULD BE NO HOTER THAN 110, THE DISHWASHERS | | | AND WASH SINKS WOULD REQUIRE HOTER WATER. SHOW HOW THIS | | | WILL BE DONE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-26 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-25 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2007-09-26 10:34:16 | DENIED; | | | 1.SEALED PLANS TO HAVE DATE WITH SIGNITURE. | | | 2. PLANS SEEM TO MEET FBC-2004 EXISTING BUILDING | | | CHAPTER 7 ( LEVEL 3 ). THIS WOULD MEAN THE BATHROOMS | | | ARE REQUIRED TO MEET THE REQUIREMENTS OF CHAPTER 11, | | | HANDICAP REQUIREMENTS. ( BATHROOMS DO NOT COMPLY) 3. | | | SHOW ON PLANS COMPLIANCE TO FBC-2004 PLUMBING TABLE | | | 403.1 (1A-2) NUMBER OF PEOPLE, FIXTURES REQUIRED. 4. | | | SANITARY RISER DIAGRAM; ( FROM LEFT TO RIGHT) | | | A)ICE BIN INDIRECT WASTE MUST GO DIRECTLY TO | | | FLOOR SINK, NOT TIE INTO HAND SINK. | | | B) DISHWASHER TO BE INDIRECTLY WASTED SEC.802.2 | | | TO A FLOOR SINK. | | | C) ICE BIN NOT PERMITED TODISCHARGEINTO | | | BATHROOM FLOOR DRAIN. (FLOOR SINK REQUIRED) | | | D) TOILETS NOT VENTED | | | E) ICE MACHINE CANNOT DISCHARGE INTO WOMANS ROOM | | | FLOOR DRAIN. | | | F) FLOOR SINKS OR HUB DRAINS ARE REQUIRED FOR | | | ALL INDIRECT WASTE SEE SECTIONS 802.3 AND 802.3.1 | | | G) WATER AND SANITARY RISER DIAGRAMS ARE REQUIRED TO BE | | | ISOMETRIC IN DESIGN AND REFLECT THE FLOOR PLAN. | | | 5. HOT WATER IS REQUIRED FOR THE HAND SINKS AND | | | DISHWASHERS SECTION607.1.1. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-11-15 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-11-15 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2007-11-15 16:18:37 | ZONING REVIEW: PASSED | | | | | | 1) AWNINGS SHALL BE SEPARATE PERMIT. | | | 2) SIGNAGE SHALL BE SEPARATE PERMIT. | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-09 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-10-09 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-10-09 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2007-10-09 11:03:16 | ZONING REVIEW: FAILED | | | | | | 1) PROFESSIONAL SEALS REQUIRE DATES | | | | | | 2) AWNING AND SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE | | | PERMITS | | | | | | MATT FLIS - 822-1445 |
|
|