| Plan Review Stops For Permit 07080952 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2008-09-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-09-12 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-09-12 |
Time |
10:33 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-08 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-08 |
Time |
10:22 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 11:17:46 | | | | | | | 106.1.3* THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | | RECORD RETENTION PROGRAM. AS REQUESTED PREVIOUSLY, ALL | | | CHANGES TO EACH SHEET SHALL BE IDENTIFIED BY CLOUDS, | | | DATE AND A REVISION NUMBER FOR THE CHANGE. SHEET A.1 | | | REVISION CHANGES SHOWS REVISIONS 1-6, BUT THE SHEET | | | SHOWS REVISIONS #5 WHICH IS NOT CLOUDED AND REVISION #7 | | | WHICH IS NOT ON THE REVISION LIST. ONLY THE REVISIONS | | | WHICH AFFECT THIS PAGE SHALL BE INDICATED; THE ONES | | | WHICH DO NOT AFFECT THIS PAGE SHALL BE REMOVED, AND BE | | | INDICATED ON THE APPROPRIATE PAGE. THIS GOES FOR ALL | | | SHEETS. THE CHANGES TO THE BATHROOM ARE NOT INDICATED | | | ON THE NEW SHEETS. | | | | | | NOTED: HOWEVER, THE MECHANICAL PLANS SHOW FOUR NEW | | | OPENINGS FOR INTAKE LOUVERS: THE ARCHITECTURAL PLANS | | | SHALL REFLECT THE OPENINGS SHOWN ON THE MECHANICAL | | | PLANS. DETAILED ELEVATION DRAWINGS SHALL BE SUBMITTED | | | INDICATING HOW THE LOUVERS AND MOTORIZE DAMPER WILL BE | | | ATTATCH TO THE OPENINGS. SHOW ALL DIMENSIONS ON THE | | | ELEVATION DRAWINGS. TWO SETS OF PRODUCT APPROVALS ARE | | | REQUIRED FOR THE LOUVERS. | | | 1)THE REVISED SHEET NEEDS TO INDICATE ALL THE CHANGES | | | WITH THE CLOUDED SYMBOL AND THE REVISION NUMBER NEXT TO | | | IT AROUND THE CHANGED AREA. THE ADDITIONAL PLUMBING | | | SYSTEMS SHALL BE INDICATED ALONG WITH THE RELOCATION OF | | | THE DOORS AND WALLS ETC. AGAIN PLEASE SHOW ALL CHANGES | | | WITH IDENTIFIABLE SYMBOLS AND THE REVISION NUMBER. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED. 106.1.1 | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-07-11 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-07-11 |
Time |
10:28 |
Sent To |
PC |
|
| Notes |
| 2008-07-11 13:46:54 | BUILDING PLAN REVIEW | | | PERMIT: 07080952 | | | ADD: 310 FLAMINGO RD. | | | CONT: ISLAND CONSTRUCTION | | | TEL: (561)804-9376 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: REVISION | | | ACTION: DENIED | | | | | | NOTED: HOWEVER, THE MECHANICAL PLANS SHOW FOUR NEW | | | OPENINGS FOR INTAKE LOUVERS: THE ARCHITECTURAL PLANS | | | SHALL REFLECT THE OPENINGS SHOWN ON THE MECHANICAL | | | PLANS. DETAILED ELEVATION DRAWINGS SHALL BE SUBMITTED | | | INDICATING HOW THE LOUVERS AND MOTORIZE DAMPER WILL BE | | | ATTATCH TO THE OPENINGS. SHOW ALL DIMENSIONS ON THE | | | ELEVATION DRAWINGS. TWO SETS OF PRODUCT APPROVALS ARE | | | REQUIRED FOR THE LOUVERS. | | | 1)THE REVISED SHEET NEEDS TO INDICATE ALL THE CHANGES | | | WITH THE CLOUDED SYMBOL AND THE REVISION NUMBER NEXT TO | | | IT AROUND THE CHANGED AREA. THE ADDITIONAL PLUMBING | | | SYSTEMS SHALL BE INDICATED ALONG WITH THE RELOCATION OF | | | THE DOORS AND WALLS ETC. AGAIN PLEASE SHOW ALL CHANGES | | | WITH IDENTIFIABLE SYMBOLS AND THE REVISION NUMBER. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED. 106.1.1 | | | | | | 2)OK | | | | | | NOTE: THE GENERATOR SHALL BE SUBMITTED UNDER 'A | | | SEPERATE PERMIT. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-24 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-24 |
Time |
09:40 |
Sent To |
P |
|
| Notes |
| 2008-06-24 11:17:21 | BUILDING PLAN REVIEW | | | PERMIT: 07080952 | | | ADD: 310 FLAMINGO RD. | | | CONT: ISLAND CONSTRUCTION | | | TEL: (561)804-9376 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: REVISION | | | ACTION: DENIED | | | | | | 1)THE REVISED SHEET NEEDS TO INDICATE ALL THE CHANGES | | | WITH THE CLOUDED SYMBOL AND THE REVISION NUMBER NEXT TO | | | IT AROUND THE CHANGED AREA. THE ADDITIONAL PLUMBING | | | SYSTEMS SHALL BE INDICATED ALONG WITH THE RELOCATION OF | | | THE DOORS AND WALLS ETC. AGAIN PLEASE SHOW ALL CHANGES | | | WITH IDENTIFIABLE SYMBOLS AND THE REVISION NUMBER. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED. 106.1.1 | | | | | | 2)THE DRAWINGS NEED TO INDICATE THE TYPE OF FLOOR AND | | | WALL FINISHES FOR THE NEW SHOWER AND MOP SINK/ LAUNDRY | | | TUB AREAS PER R307. THE TYPE OF GLAZING, IF ANY, SHALL | | | MEET THE REQUIREMENTS OF R308. (ROOMS 105 AND 105A) | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-18 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-17 |
Time |
15:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-13 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-13 |
Time |
06:57 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-02-21 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-02-20 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-18 |
Time |
13:02 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-12-18 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2007-12-18 13:30:12 | BUILDING PLAN REVIEW | | | PERMIT: 07080952 | | | ADD: 310 FLAMINGO DRIVE | | | CONT: ISLAND CONSTRUCTION | | | TEL: (561)236-9983 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. | | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 2-3) COMPLIED. | | | | | | 4) PARTIALLY COMPLIED. PLANS DO INDICATE A LEVEL II | | | ALTERATION, THE APPLICABLE CODES ARE 2004 FBC WITH 2007 | | | REVISIONS ORSUPPLEMENTS 2004 EXISTING BUILDING CODE, | | | AND THE 2004 RESIDENTIAL CODE WITH 2007 REVISIONS OR | | | SUPPLEMENTS. | | | THE PLANS CURRENTLY INDICATE THIS TO BE A R3 RESIDENCE | | | AND THE GARAGE A ACCESSORY USEAGE. THE PLANS DO MEET | | | THIS CRITERIA FOR A ONE & TWO FAMILY RESIDENCE AND THIS | | | REVIEW WILL BE COMPLETED AS SUCH. | | | FOR THE BUILDING DEPARTMENTS OCCUPANCY CLASSIFICATION | | | IT WILL NEED TO REPRESENT A R3 OCCUPANCY ON THE SHEET | | | A.0. WE HAVE NO SUCH CLASSIFICATION AS COMMERCIAL LIVE/ | | | WORKIF THIS IS A ZONING CLASSIFICATION PLEASE SESIGNATE | | | AS SUCH. | | | | | | 5) SEMI-COMPLIED, THE RESPONCE INDICATES AS WELL AS THE | | | PLANS THIS IS TO BE A R3 RESIDENCE AND THE RESPONCE | | | LETTER INDICATES THE STORAGE PORTION TO BE USED AS A | | | GARAGE.WITH THIS NEW KNOWLEDGE OF WHAT TYPE OF | | | OCCUPANCY CLASSIFICATION WILL BE USED FOR THIS | | | STRUCTURE THE DESIGNER NEEDS TO COMPLY WITH R 309.1 | | | OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM | | | USED FOR SLEEPING SHALL NOT BE PERMITTED. SEE THE REST | | | OF THE SECTION AS TO FIRE RATINGS REQUIRED. | | | | | | 6-11) COMPLIED. | | | | | | 12-13) BOTH COMMENTS DEAL WITH THE ENERGY CALCS, THE | | | ENERGY CALCULATIONS ARE COMPLETED ON FORM 400A, THIS | | | PLAN NOW STATES THIS IS A R-3 OCCUPANCY WITH THE GARAGE | | | BEING A ACCESSORY OCCUPANCY, THERE ARE NO LONGER WALLS | | | WITH SEPERATION BETWEEN BAYS. PLEASE REVISE THE ENERGY | | | CALCULATIONS. NOTE THE ENERGY CALCULATIONS NEED TO | | | ACCURATELY DEPICT THE FIXTURES LISTED ON SHEET E-2. | | | | | | 14) THIS PLAN APPEARS TO HAVE A CHANGE IN OCCUPANCY | | | REQUIRING PALM BEACH COUNTY IMPACT FEE ASSESSMENT. | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-26 |
Time |
19:56 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-09-26 |
Time |
19:56 |
Sent To |
|
|
| Notes |
| 2007-09-26 20:30:19 | BUILDING PLAN REVIEW | | | PERMIT: 07080952 | | | ADD: 310 FLAMINGO DRIVE | | | CONT: ISLAND CONSTRUCTION | | | TEL: (561)236-9983 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | | REVIEW FOR PERMIT. | | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 2) PLLEASE SEE NOTES FROM JOHN ROACH IN ZONING THAT A | | | WORK LIVE LOFT CAN ONLY USE 20% OF THE GROSS FLOOR | | | AREA, THE PLAN ON SHEET A.1 INDICATES THAT 80 % OF THE | | | STRUCTURE WOULD BE | | | STORAGE NOT THE ALLOWABLE 20%. THE OTHER ISSUE FOR A | | | WORK LIVE LOFT IS THAT IT NEEDS TO MEET THE DEFINITION | | | OF DWELLING UNIT. DWELLING UNIT . A SINGLE UNIT | | | PROVIDING COMPLETE, INDEPENDENT LIVING FACILITIES FOR | | | ONE OR MORE PERSONS, INCLUDING PERMANENT PROVISIONS FOR | | | LIVING, SLEEPING, EATING, COOKING AND SANITATION. THIS | | | PLAN LACKS SLEEPING QUARTERS, MAKING IT NOT A DWELLING | | | UNIT. | | | PLANS ALSO FAIL TO INDICATE WHICH WINDOWS WILL QUALIFY | | | AS THE EMERGENCY EGRESS OPENINGS FOR THE SLEEPING | | | QUARTERS.1025.1/ 1025.2. | | | | | | 3) PLEASE CORRECT THE A.0 COVERSHEET WITH REGARDS TO | | | FLOOD ZONE INFORMATION, THIS IS NOT IN A "AH" FLOOD | | | ZONE. | | | | | | 4) PLEASE PROVIDE TO WHAT LEVEL OF ALTERATION WILL BE | | | COMPLETED UNDER THIS PERMIT. PROVIDE INFORMATION | | | ADDITIONAL INFORMATION TO THE APPLICABLE ODES, 2004 FBC | | | BUILDING W/ 2007 REVISONS | | | 2004 EXISTING BUILDING CODE W/ 2006 REVISIONS | | | | | | 5A) PLANS INDICATE A PROPOSED STORAGE OCCUPANCY, WHAT | | | TYPE OF MATERIALS WOULD BE STORED THERE?PROVIDE IF | | | S1, S2 OR HAZARDOUS MATERIALS, AND QUANITIES.SEE TABLE | | | 302.3.2 FOR HR RATING, NOT A 1 HR WALL IF S1 THEN 3HR | | | RATED WALL, S2 THEN A 2HR RATED WALL BETWEEN THE | | | STORAGE OCCUPANCY AND R3 OCCUPANCY. | | | | | | 5B) UNDER THE STORAGE OCCUPANCY, IS THIS A SINGLE | | | TENANT OCCUPANCY OR MULTIPLE TENANT OCCUPANCY? PLANS DO | | | NOT SHOW EGRESS DOORS IF MULTIPLE STORAGE TENANT. | | | | | | 6)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) | | | OF PRODUCT TESTING REPORTS ,MISSING REPORTS ARE AS | | | FOLLOWS: | | | 6A) ROOFING ASSEMBLIES W/INSULATION | | | | | | 7) THIS ROOF IS MISSING OR NOT INCOMPLIANCE WITH | | | THE FOLLOW ITEMS: | | | _X__ CONTRACTOR DID NOT PROVIDE THE MEAN ROOF HEIGHT. | | | _X__ CONTRACTOR DID NOT INDICATE THE ROOF PITCH. _X__ | | | CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO BE USED. | | | NO REPORT SUBMITTED. | | | _X__ THE SYSTEM PROVIDED HAS A LOWPRESSURE FOR ZONE | | | 2&3___ . | | | X___ THE SYSTEM PROVIDED STATESLIMITATION# 7, SHOULD | | | THE FASTENER | | | RESISTANCE BE LESS THAN THAT REQUIRED, AS | | | DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISEDFASTENER SPACING, | | | PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | ___THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO | | | ENHANCED FASTENING ALLOWED. | | | | | | 8) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 9)THE STORAGE OCCUPANCIES INDICATE A FUTURE TOILET | | | IN EACH OF THREE BAYS, AT WHAT TIME IS THE FUTURE | | | TOILET TO BE INSTALLED, IF SHOWN ON THESE PLANS ARE | | | THEY TO BE PART OF THIS PERMIT. | | | THEY WILL NEED TO MEET THE REQUIREMENTS FOR | | | ACCESSIBILITY FOR HANDICAPPED RESTROOMS IF SEPERATE | | | TENANTS. 11-4.22 AND OR 11-4.16. | | | | | | 10) DISCREPANCIES, A-1 VS E -1 SHEET E-1 IS MISSING THE | | | REQUIRED EGRESS DOORS FORT HE STORAGE OCCUPANCIESTHAT | | | ARE SHOWN ON A-1. SHEET A-2 ALSO DOESN'T INDICATE THE | | | EGRESS DOORS. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 11)A.1 TOLIET ROOMS DO NOT INDICATE ANY WINDOWS NOR | | | DO THEY SHOW ON E2 ANY LIGHT FIXTURES WITHIN THE | | | RESTROOM FACILITIES1205.3 ARTIFICIAL LIGHT. | | | | | | 12)THE ENERGY CALCS INPUT DATA REPORT SHEET 3 | | | &INDICATES THERE TO BE LIGHTS WITHIN THEWAREHOUSE | | | RESTROOM A 50 WATT FIXTURE WHERE AS THE E2 SHEET | | | DOESN'T INDICATE ANY 50 WATT FIXTURES NOR DOES THE | | | LIGHTING PLAN CORRELATE WITH THE LIGHTING LEGEND. | | | 13-415.2 | | | | | | 13) WHEN REVIEWING THE ENERGY CALCS FOR THE LIGHTING | | | SHEETS 2& 3 OF THE INPUT DATA REPORT NONE OF THE | | | FIXTURES MATCH THE FIXTURE LEGEND FOUND ON SHEET E-2 | | | SEE 13-415.2. | | | | | | 14) SHEET E-2 IS MISSING THE EGRESS DOORSSHOEN ON A-2 | | | AND EXIT LIGHTING FOR THE (3) STORAGE BAYS. 2004 FBC | | | SECTION 1006. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-17 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-17 |
Time |
07:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-24 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-24 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-10 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-10 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2007-12-10 15:39:26 | | | | | | | APPLICATION #07080952 | | | ELECTRICAL PLAN REVIEW | | | 310 FLAMINGO DRIVE | | | 12/10/07 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ARTICLES REFERENCED ARE 2005 NEC UNLESS OTHERWISE | | | NOTED. | | | | | | ALTHOUGH THE ELECTRICAL REVIEW WAS PASSED ON 9/12/07, | | | THESE COMMENTS COME FROM NEW INFORMATION AND DRAWINGS | | | SUBMITTED ON 11/28/07. | | | | | | 1} ELECTRICAL SPECIFICATIONS, SHEET E-0, PART 3 (A), | | | INDICATES THE COLOR CODING FOR A SINGLE PHASE, 120/240 | | | VOLT SYSTEM. THE RISER DIAGRAM INDICATES THE SERVICE | | | BEING 3 PHASE 120/208 SYSTEM, CORRELATE SAME. | | | | | | 2} THE PANEL SCHEDULES INDICATE THE PANELS ARE ?FED | | | FROM UTILITY?, CORRECT TO INDICATE FED FROM MAIN | | | DISCONNECT.106.1.3 FBC AS AMENDED. | | | | | | 3} INDICATE THE BRANCH CIRCUIT CONDUCTOR SIZES ON THE | | | PANEL SCHEDULE SO THAT COMPLIANCE WITH 310.16 CAN BE | | | REVIEWED. | | | | | | 4} CIRCUIT LPA-5 HAS TWO RECEPTACLES LOCATED ON A | | | KITCHEN COUNTERTOP AND MUST COMPLY WITH SMALL APPLIANCE | | | BRANCH CIRCUIT ARTICLES. SEE 210.52(A), 210.52(C), AND | | | 210.8(A)(6) GFI. | | | | | | 5} SEE 210.52(C)(2) FOR ISLAND RECEPTACLE REQUIREMENT, | | | LOCATE SAME ON PLAN. | | | | | | 6} THE MOCP FOR AIR HANDLERS 1,2 AND 4, ON SHEET M.2, | | | AND THE OCP IN THE PANEL SCHEDULES, SHEET E-0, FOR | | | THOSE UNITS ARE IN CONFLICT. CORRELATE SAME. | | | | | | 7}210.52(E) OUTDOOR OUTLETS FOR A ONE-FAMILY DWELLING | | | AND EACH UNIT OF A TWO-FAMILY DWELLING THAT IS AT GRADE | | | LEVEL, AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE AT | | | GRADE LEVEL AND NOT MORE THAN 2.0 M (6 1/ 2 FT) ABOVE | | | GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF THE | | | DWELLING. LOCATE SAME ON PLANS. | | | | | | 8} CIRCUIT LPA-35 AND LPA-17 MUST BE AFCI PROTECTED PER | | | 210.12. | | | | | | 9} THE ENERGY CERTIFICATIONS SUBMITTED ARE FOR A | | | WAREHOUSE, SHEET A.1 INDICATES AN R3 BUILDING TYPE. THE | | | APPLICATION STATES NO CHANGE OF OCCUPANCY. THE GARAGE | | | IS LABELED ?ACCESSORY TO RESIDENCE?.CORRELATE THESE | | | DOCUMENTS, DECLARE OCCUPANCY TYPE, IF R3 CHECK THE | | | CHANGE OF OCCUPANCY BOX ON THE APPLICATION, SUBMIT | | | ENERGY CALCULATIONS PER 13-600. | | | | | | THE ELECTRICAL REVIEW WAS DONE FOR R3 AS INDICATED ON | | | THE PLAN. PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND | | | REPLACE WITH CORRECTED ONES WHEN RESUBMITTING. INCLUDE | | | THEM SEPARATELY TO EXPEDITE THE REVIEW PROCESS. RESPOND | | | TO REVIEW COMMENTS IN WRITING. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-12 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-12 |
Time |
06:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-21 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-21 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2008-02-21 16:56:37 | ****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS A.1, A.3 AND E-2 WERE | | | STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-12-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-26 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-26 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2007-12-26 14:26:36 | *****UNSAT***** | | | | | | THE FOLLOWING COMMENTS (OF 9) TAKEN FROM THE PREVIOUS | | | FIRE PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | | | | 5.PAGE A-5 DOES NOT MATCH ELECTRICAL DRAWINGS AS THEY | | | RELATE TO EXIT LIGHTS AND EMERGENCY LIGHTS. | | | | | | 7.PLEASE DECLARE MATERIALS PLANNED TO BE STORED IN | | | STORAGE AREAS.IS ANY FLAMMABLE, COMBUSTIBLE, TOXIC, | | | POISONOUS, OR EXPLOSIVE SOLIDS, LIQUIDS, OR GASES | | | PLANNED TO BE STORED? | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2007-10-22 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2007-10-22 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-10-22 14:05:07 | 1. BUILDING ADDRESS IS REQUIRED ON THE PROPER BUILDING | | | ELEVATION. A MINIMUM OF AT LEAST 6" HIGH 1" WIDE | | | NUMBERS ARE REQUIRED. | | | | | | 2. DEMOLITION, RENOVATION, AND CONSTRUCTION TO COMPLY | | | WITH NFPA 241. | | | | | | 3. ELECTRIC POWERED SMOKE DETECTORS ARE REQUIRED WITHIN | | | THE RESIDENTIAL PORTION OF THE BUILDING. WHEN | | | ACTIVATED, THE DETECTOR(S) SHALL BE AUDIBLE TO ALERT | | | PERSONS OF A FIRE EMERGENCY. | | | | | | 4. ON M-1 PLANS MAKE REFERENCE TO CARBON DIOXIDE | | | DETECTORS AND IN OTHER INSTANCES IT CALLS OUT THE | | | SYMBOL FOR CARBON MONOXIDE DETECTORS. PLEASE CORRECT | | | PLANS. | | | | | | 5. PAGE A-5 DOES NOT MATCH ELECTRICAL DRAWINGS AS THEY | | | RELATE TO EXIT SIGNS AND EMERGENCY LIGHTING. | | | | | | 6. PLANS CALL CLASS C FLAMESPREAD BUT THE PLANS | | | INDICATE THAT THE BUILDING IS NON FIRE SPRINKLER | | | PROTECTED. PLEASE CORRECT PLANS AS NECESSARY. | | | | | | 7. PLEASE DECLARE MATERIALS PLANNED TO BE STORED IN | | | STORAGE AREAS. IS ANY FLAMMABLE, COMBUSTIBLE, TOXIC, | | | POSIONOUS, OR EXPLOSIVE SOLIDS, LIQUIDS, OR GASES | | | PLANNED TO BE STORED. | | | | | | 8. VEHICLES IF PLANNED TO BE STORED IN THESE AREAS, THE | | | VEHICLES SHALL CONTAIN VERY LITTLE FUEL AND HAVE THE | | | BATTERY TERMINALS DISCONNECTED. | | | | | | 9. PLEASE ILLUSTRATE ANY PORTABLE FIRE EXTINGUISHING | | | EQUIPMENT PLANNED FOR THE SPACE. | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2008-09-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-16 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-16 |
Time |
14:44 |
Sent To |
Z |
|
| Notes |
| 2008-09-16 14:46:54 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2008-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-05 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-05 |
Time |
10:20 |
Sent To |
M |
|
| Notes |
| 2008-09-05 10:20:42 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-08 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-08 |
Time |
13:19 |
Sent To |
P |
|
| Notes |
| 2008-08-08 13:19:56 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-28 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-28 |
Time |
10:11 |
Sent To |
M |
|
| Notes |
| 2008-07-28 10:11:46 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-28 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-28 |
Time |
10:09 |
Sent To |
M |
|
| Notes |
| 2008-07-28 10:09:34 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-03 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-03 |
Time |
11:20 |
Sent To |
P |
|
| Notes |
| 2008-07-03 11:21:01 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-03 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-03 |
Time |
11:17 |
Sent To |
M |
|
| Notes |
| 2008-07-03 11:17:40 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-03 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-03 |
Time |
11:05 |
Sent To |
Z |
|
| Notes |
| 2008-07-03 11:06:08 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-25 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-25 |
Time |
13:43 |
Sent To |
M |
|
| Notes |
| 2008-06-25 13:43:43 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-16 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-16 |
Time |
14:11 |
Sent To |
B |
|
| Notes |
| 2008-06-16 14:14:48 | TO "MJACOBS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-11 |
Time |
08:30 |
Sent To |
E |
|
| Notes |
| 2008-06-11 08:31:24 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-16 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-16 |
Time |
13:16 |
Sent To |
B |
|
| Notes |
| 2008-04-16 13:16:44 | TO "MJACOBS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-04 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-04 |
Time |
10:45 |
Sent To |
B |
|
| Notes |
| 2008-03-04 10:46:17 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-27 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-27 |
Time |
09:50 |
Sent To |
M |
|
| Notes |
| 2008-02-27 09:51:10 | TO "TGORDON" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-23 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-23 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2008-01-23 17:11:48 | TO "COMM" BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-28 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-28 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2007-12-03 08:35:07 | TO "COMM" BD#14 | | 2007-11-28 14:39:36 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-02 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-04 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2007-09-22 10:37:10 | TO COMM BOARD SPACE #3.DVP | | 2007-09-04 10:36:07 | WAITING FOR "COMM" BD--CHANGED FROM "RES-REMOD" TO | | | "COM-REMOD" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
N |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-08 |
Time |
15:49 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2008-09-08 |
Time |
15:49 |
Sent To |
B |
|
| Notes |
| 2008-09-08 15:49:43 | BUILD. REVISION NOT MECH. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
N |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-28 |
Time |
11:16 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2008-07-28 |
Time |
11:16 |
Sent To |
B |
|
| Notes |
| 2008-07-28 11:16:53 | REVISION TO BUILDING PLANS NOT MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-03 |
Time |
16:33 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-07-03 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2008-07-03 16:36:11 | REVISION TO MECH. PLANS PAGE M.1, M.2, M.3, ENERGY | | | CAL'S. AND COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-26 |
Time |
11:50 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-06-26 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2008-06-26 12:27:46 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLANS | | | *** DENIED *** | | | 1) MECHANICAL PLANS ON FILE WERE SIGNED AND SEALED BY | | | AN ENGINEER (MICHAEL M. BASSFORD) SO ONLY HE CAN MAKE | | | REVISIONS TO THEM, PER FAC 61G15-23.002. | | | | | | 2) PLEASE HAVE THE ENGINEER ALSO REVISE THE ENERGY | | | CALCULATIONS AND COOLING LOAD CALCULATIONS AS THEY HAVE | | | BEEN SIGNED AND SEALED BY HIM ALSO AND WILL NEED TO BE | | | REVISED AS A RESULT OF THE CHANGES IN THE MECHANICAL | | | PLANS, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 3) PLEASE SHOW THE OUTSIDE AIR CALCULATIONS ON THE | | | MECHANICAL PLAN AND PROVIDE OUTSIDE AIR WERE REQUIRED | | | BY 2004 FBC/R R303 AND FBC/M TABLE 403.3. | | | | | | 4) PLEASE SUBMIT MANUFACTURER'S SPECIFICATION'S AND | | | INSTALLATION INSTRUCTIONS FOR THE 26X26 MOTORIZED | | | DAMPERS, AND 30" WEATHER HOOD FOR THE EXHAUST FAN, | | | SHOWING COMPLIANCE WITH 2004 FBC 1609 WIND LOADS. | | | PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR LOUVERS IF | | | BEING USED, SEE FS 553.842(1) AND FAC RULE 9B-72, | | | 9B-72.005, AND FAC 9B-72.010(31)(C). | | | | | | 5) THE BUILDING PLANS WILL NEED TO BE REVISED SHOWING | | | THE NEW OUTDOOR AIR OPENINGS AND EXHAUST OPENING, PER | | | 2004 FBC 1609. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
N |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-26 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-06-26 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-27 |
Time |
11:51 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-02-27 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-25 |
Time |
08:04 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-01-25 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2008-01-25 08:28:27 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS ARE CALLING FOR 14 SEER A/C | | | SYSTEMS, THE PLANS PAGE M.2 A/C SCHEDULE IS CALLING FOR | | | 13 SEER A/C SYSTEMS. THE PLANS CAN NOT CALL FOR LESS | | | THAN THE ENERGY CALCULATIONS. PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-12 |
Time |
09:30 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-12-12 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-10-11 |
Time |
19:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-10-11 |
Time |
19:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-11 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-11 |
Time |
10:19 |
Sent To |
PC |
|
| Notes |
| 2008-08-11 10:30:21 | REVISION SHEET P.1 AND ADDED SHEET P.2: "OK" MOVED | | | FIXTURES AND ADDED SHOWER IN BACK BATHROOM. ADDED SINK | | | IN UTILITY ROOM. ADDED HOSE BIBBS. STUBBED FOR FUTURE | | | UTILTY SINK AND ADDED WATER FOR FUTURE ICE MACHINE. | | | | | | ****************PROVISO**************** | | | A} WATER HAMMER ARRESTORS SHALL BE INSTALLED WHERE | | | QUICK CLOSING VALVES ARE UTILIZED. (DISHWASHER, FUTURE | | | ICE MACHINE). PER FBC- PLUMBING SECTION 604.9 WATER | | | HAMMER. | | | B} A TWO-WAY CLEANOUT SHALL BE INSTALLED AT THE | | | JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER. PER | | | FBC- PLUMBING SECTION 708.3.5. BUILDING DRAIN AND | | | BUILDING SEWER JUNCTION. | | | C} SHEET P.1 PLUMBING FIXTURES: SEE RED LINE | | | CORRECTION TO WASHING MACHINE WASTE (3"). | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-23 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-23 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2008-07-23 14:52:40 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | 1. SHT P.1 OF 1 REVISIONS TO PLANS SIGNED AND SEALED BY | | | A PROFESSIONAL ENGINEER SHALL BE SIGNED AND SEALED BY | | | THE ENGINEER OF RECORD. FS 471.--PREVIOUS REVIEWED | | | SHEET SHOWED REVISIONS 1 & 2. NEW REVISIONS 3, 4 & 5 | | | ARE NOT INDICATED WITH CLOUDS OR REVISION NUMBERS. MUCH | | | OF THE INFORMATION ON THE REVIEWED/STAMPED PLANS HAS | | | BEEN DELETED SUCH AS THE WATER RISER DIAGRAM ETC. SHT | | | NOW IS INDICATED AS P.1 OF 7. PLEASE CLARIFY. SECTION | | | 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-24 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-24 |
Time |
15:50 |
Sent To |
PC |
|
| Notes |
| 2008-06-24 16:12:12 | PLUMBING PLAN REVIEW: | | | REVISION DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A.1 FLOOR PLAN ROOM 105 & 105A: ALL CHANGES | | | TO THE PLAN ARE TO BE CLOUDED WITH REVISION | | | NUMBERS/DATES PER FBC-2004 CHAPTER 1, SECTION 106.1.3 | | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | | RECORD RETENTION PROGRAM. | | | NOTE: A TRANSMITTAL LETTER IS HELPFUL. | | | | | | 2. SHEET A.1 FLOOR PLAN ROOM 105 & 105A: CLEARLY | | | IDENTIFY ALL FIXTURES IN THESE ROOMS. PER FBC- PLUMBING | | | SECTION 401.1 SCOPE. | | | | | | 3. PLEASE PROVIDE A REVISED SHEET P.1 SANITARY AND | | | WATER RISER DIAGRAMS CLEARLY INDICATING THE NEW LAYOUT | | | OF ROOMS 105 & 105A PLUMBING FIXTURES WITH THE ADDED | | | FIXTURES. PER (W.P.B. AS AMENDED) SECTION 106.3.5.4 (9) | | | PLUMBING. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-02-21 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-02-21 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2008-02-21 15:14:13 | ****************PROVISO**************** | | | PER FBC PLUMBING SECTION *406.3 WASTE CONNECTIONS.THE | | | TRAP AND FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES WASHER | | | SHALL BE A MINIMUM OF 2 INCHES (51MM) IN DIAMETER. THE | | | AUTOMATIC CLOTHES WASHER FIXTURE DRAIN SHALL CONNECT TO | | | A BRANCH DRAIN OR DRAINAGE STACK A MINIMUM OF 3 INCHES | | | (76MM) IN DIAMETER. (REVISION REQUIRED) | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-15 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-15 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2007-12-15 07:39:06 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | | | | 2. DECLARE THE OCCUPANCY. IT APPEARS THAT THESE ARE | | | WAREHOUSES AND THE RESIDENTIAL AREA DOES NOT MEET THE | | | DEFINITION OF DWELLING IN AS IT DOES NOT HAVE SLEEPING | | | PROVISIONS. SECTION 310.2. COMMERCIAL LIVE/WORK DOES | | | NOT INDICATE THE OCCUPANCY OF THE COMMERCIAL SECTION. | | | SECTION 106.1.1. | | | ****RESPONSE NOTED, BUT THE COMMENT WAS NOT ADDRESSED. | | | JOHN ROACH IS NOT A BUILDING OR PLUMBING PLAN REVIEWER | | | AND HAS NO KNOWLEDGE OF OUR REQUIREMENTS. THERE HAS | | | BEEN PLAN DEVELOPMENT BETWEEN THE FIRST REVIEW AND THE | | | PRESENT REVIEW. AS SUCH NEW COMMENTS WILL BE INDICATED. | | | THE OCCUPANCY STILL IS NOT INDICATED. | | | | | | 3. SHT A-1 THE STORAGE OCCUPANCIES REQUIRES DRINKING | | | FOUNTAINS AND SERVICES SINKS IF, AS INDICATED ON THE | | | ENERGY CALCULATIONS, THERE WILL BE FOUR WAREHOUSE BAYS. | | | PLEASE ALSO INDICATE THE TYPE OF MATERIAL & THE AMOUNT | | | THAT WILL BE STORED IN THE STORAGE BAYS. MSDS SHEETS | | | MAY BE REQUIRED AS WELL AS AN EYE WASH/EMERGENCY SHOWER | | | DEPENDING ON THE RESPONSE OF THIS COMMENT AND THE MSDS | | | SHEETS. SECTION 106.1.2 & TABLE 403.1. | | | ****RESPONSE NOTED, BUT THE COMMENT WAS NOT ADDRESSED. | | | JOHN ROACH IS NOT A BUILDING OR PLUMBING PLAN REVIEWER | | | AND HAS NO KNOWLEDGE OF OUR REQUIREMENTS. THERE IS A 2 | | | HRFIRE SEPARATION WALL INDICATED, BUT THE SPACE IS | | | INDICATED AS AN ACCESSORY TO RESIDENCE. MORE | | | INFORMATION IS STILL REQUIRED. | | | | | | 4. SUBMIT AN EXISTING FLOOR PLAN SO THE EXTENT OF THE | | | WORK CAN BE ESTABLISHED. SECTION 106.1.2, MORE | | | INFORMATION REQUIRED. | | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. THE DEMO | | | SHOWS NOT EXISTING TOILET ROOMS, KITCHEN, WASH MACHINE | | | CONNECTIONS, SLEEPING PROVISIONS ETC THAT ARE REQUIRED | | | IN A RESIDENCE. IF THIS IS AN EXISTING RESIDENCE, WHERE | | | ARE ALL OF THE EXISTING REQUIRED ELEMENTS? A | | | PRE-INSPECTION MAY BE REQUIRED TO VERIFY INFORMATION | | | INDICATED IN THE PLANS. | | | | | | 5. SHT A.1 THE FUTURE TOILET ROOMS SHALL BE ACCESSIBLE. | | | SHOW COMPLIANCE WITH SECTIONS 11-4.15, 11-4.16, 11-4.19 | | | & 11-4.22 WITH ALL SUBSECTIONS AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING.--SUBMIT DETAILS IN | | | BOTH A FLOOR PLAN AND ELEVATIONS. | | | ****RESPONSE NOTED, BUT THE "COMMERCIAL" INDICATION ON | | | SHT A.0 REQUIRES THAT ALL TOILET ROOMS PROVIDED SHALL | | | BE ACCESSIBLE AND SHALL BE ON AN ACCESSIBLE ROUTE. | | | SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19 & 11-4.22 WITH ALL SUBSECTIONS. ALSO | | | SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | | SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A). | | | | | | 6. OK | | | | | | 7. N/A PLAN DEVELOPMENT. | | | | | | 8. OK | | | | | | 9. SHT P.1 NO SANITARY OR WATER PIPING ARE SHOWN TO THE | | | WASH MACHINE. TABLE 403.1. | | | ****RESPONSE NOTED, BUT WATER HAMMER ARRESTORS ARE | | | REQUIRED AT THE WASH MACHINE PER SECTION 604.9. | | | | | | **********NEW COMMENT********** | | | | | | 1B. SEE ATTACHED SHEET CONCERNING THE DESIGN | | | PROFESSIONAL AND FS 553.80(2)(B). THIS IS GIVEN AS A | | | NOTICE AT THIS TIME. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-02 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-02 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2007-11-02 18:23:39 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. PLANS SHALL BE SUBMITTED IN A MINIMUM OF TWO | | | COMPLETE SETS. LOOSE SHEETS ARE NOT ACCEPTABLE. SECTION | | | 106.1. | | | | | | 2. DECLARE THE OCCUPANCY. IT APPEARS THAT THESE ARE | | | WAREHOUSES AND THE RESIDENTIAL AREA DOES NOT MEET THE | | | DEFINITION OF DWELLING IN AS IT DOES NOT HAVE SLEEPING | | | PROVISIONS. SECTION 310.2. COMMERCIAL LIVE/WORK DOES | | | NOT INDICATE THE OCCUPANCY OF THE COMMERCIAL SECTION. | | | SECTION 106.1.1. | | | | | | 3. SHT A-1 THE STORAGE OCCUPANCIES REQUIRES DRINKING | | | FOUNTAINS AND SERVICES SINKS IF, AS INDICATED ON THE | | | ENERGY CALCULATIONS, THERE WILL BE FOUR WAREHOUSE BAYS. | | | PLEASE ALSO INDICATE THE TYPE OF MATERIAL & THE AMOUNT | | | THAT WILL BE STORED IN THE STORAGE BAYS. MSDS SHEETS | | | MAY BE REQUIRED AS WELL AS AN EYE WASH/EMERGENCY SHOWER | | | DEPENDING ON THE RESPONSE OF THIS COMMENT AND THE MSDS | | | SHEETS. SECTION 106.1.2 & TABLE 403.1. | | | | | | 4. SUBMIT AN EXISTING FLOOR PLAN SO THE EXTENT OF THE | | | WORK CAN BE ESTABLISHED. SECTION 106.1.2, MORE | | | INFORMATION REQUIRED. | | | | | | 5. SHT A.1 THE FUTURE TOILET ROOMS SHALL BE ACCESSIBLE. | | | SHOW COMPLIANCE WITH SECTIONS 11-4.15, 11-4.16, 11-4.19 | | | & 11-4.22 WITH ALL SUBSECTIONS AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING.--SUBMIT DETAILS IN | | | BOTH A FLOOR PLAN AND ELEVATIONS. | | | | | | 6. AN RPZV BACKFLOW IS REQUIRED ON THE WATER SERVICE TO | | | THE BUILDING. SECTION 608.13.2. | | | | | | 7. SHT P.1 2 WATER CLOSETS ARE NOT INDICATED AS FUTURE | | | FIXTURES. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 8. SHT P.1 KEY PLAN NOTES #1 IS NOT SHOWN ON THE FLOOR | | | PLAN. PLEASE INDICATED NOTE #1. SECTION 106.1.2. | | | | | | 9. SHT P.1 NO SANITARY OR WATER PIPING ARE SHOWN TO THE | | | WASH MACHINE. TABLE 403.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2008-09-21 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-09-21 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-09-21 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2008-09-12 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-09-12 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-09-12 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2008-09-12 16:11:30 | ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. AS PER SECTION | | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-07-08 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-07-08 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2008-07-08 08:26:39 | ***FAILED - REVISION - A/C LOCATION CHANGE AND PAD | | | DETAIL, CHANGES TO INTERIOR FRAMING.*** | | | | | | | | | 1)AS THE MECHANICAL EQUIPMENT LOCATION HAS CHANGED | | | FROM WHAT WAS ORIGINALLY APPROVED, THE A/C EQUIPMENT | | | AND GENERATOR PAD DO NOT MEET THE MINIMUM REQUIRED | | | SETBACK DIMENSIONS.AS PER SECTION 94-305(B)(4) OF THE | | | ZLDRS: MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 | | | FEET INTO A REQUIRED SETBACK. | | | | | | SECTION 94-148.PROFESSIONAL OFFICE RESIDENTIAL (POR) | | | DISTRICT. | | | (2)MINIMUM SETBACKS: | | | A.FRONT: 25 FEET. | | | B.CORNER: 15 FEET. | | | C.SIDE: TEN FEET. | | | D.INTERIOR SIDE: TEN FEET. | | | E.REAR: 15 FEET. | | | | | | THE MINIMUM REQUIRED REAR SETBACK IS 11' TO ANY | | | MECHANICAL EQUIPMENT.THE MINIMUM REQUIRED SIDE | | | SETBACK IS 6' TO ANY MECHANICAL EQUIPMENT.REVISE | | | PLANS ACCORDINGLY. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | [email protected] | | | | | | | | | | | | | | | SENT TO "B" - MJ |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-04 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-04 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2007-12-04 12:37:26 | ***APPROVED - RESUB #1*** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-07 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-07 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2007-09-07 17:50:26 | ***FAILED*** | | | | | | | | | 1)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS: AS THE VALUE OF THE | | | PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE, ALL | | | LANDSCAPING SHALL BE REQUIRED TO MEET ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | | | | 2)THIS SPACE APPEARS TO BE SETUP TO BE RENTED AS | | | WAREHOUSING SPACE, WHICH IS NOT A PERMITTED USE IN THE | | | POR ZONING DISTRICT. | | | | | | 3)GATE/FENCE EXCEED MAXIMUM HEIGHT ALLOWABLE WITHIN | | | FRONT SETBACK.PURSUANT TO SECTION 94-302(C)(1): | | | MAXIMUM HEIGHT.IN NONRESIDENTIAL DISTRICTS, NO FENCE, | | | HEDGE OR WALL SHALL EXCEED EIGHT FEET IN HEIGHT WITHIN | | | THE REQUIRED SIDE AND REAR SETBACKS. FENCES AND WALL | | | SHALL NOT EXCEED 48 INCHES IN HEIGHT WITHIN THE | | | REQUIRED FRONT SETBACK. | | | | | | 4)ANY NEW WALL/FENCE REQUIRES AN EASEMENT CONSENT | | | FORM FROM THE CITY OF WEST PALM BEACH DEPARTMENT OF | | | PUBLIC UTILITIES. | | | | | | 5)SHOW SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO THE PROPERTY LINES. | | | | | | 6)THE SITE PLAN (A.0) SHOWS A BOX STRUCTURE ON THE | | | SOUTHEAST CORNER OF THE LOT.WHAT IS THIS?PROVIDE | | | DIMENSIONS, HEIGHT, ETC... | | | | | | 7)PROVIDE A PHOTOMETRIC PLAN SHOWING THE PROJECTED | | | FOOT CANDLES OF THE EXTERIOR LIGHTING AT THE | | | NEIGHBORING RESIDENTIAL LINES.AS PER SECTION | | | 94-310(D): GLARE.ANY OPERATION OR ACTIVITY PRODUCING | | | GLARE SHALL BE CONDUCTED SO THAT DIRECT OR INDIRECT | | | LIGHT FROM THE SOURCE SHALL NOT CAUSE ILLUMINATION IN | | | EXCESS OF 0.5 FOOT CANDLES WHEN MEASURED IN A | | | RESIDENTIAL DISTRICT. | | | | | | 8)PROVIDE ALL DIMENSIONS ON SITE PLAN (A.0): | | | DIMENSION OF PROPOSED AWNINGS TO PROPERTY LINES, | | | DIMENSION AWNINGS PROTRUDE FROM BUILDING, ETC... | | | | | | 9)REMOVE EXCESS PLANS FROM PACKET THAT ARE NO LONGER | | | VALID. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|