Plan Review Details - Permit 07080911
| Plan Review Stops For Permit 07080911 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-11-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-11 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-11 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-07 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-07 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2007-11-07 12:04:37 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LISTS: | | | | | | | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS.PLEASE SELECT AN APPROVED ASSEMBLY; MUST | | | STATE GENERAL LIMITATION #7 (NOT #9).NONE SELECTED. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES.CONTRACTOR | | | SPACIFIED ENHANCED FASTENING BUT THE APPROVED ASSEMBLY | | | MUST BE SELECTED BEFORE I CAN DO THE CALCULATIONS TO | | | DETERMINE CODE COMPLIANCE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-02 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-02 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2007-10-02 16:56:18 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LISTS: | | | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS.PLEASE SELECT AN APPROVED ASSEMBLY; MUST | | | STATE GENERAL LIMITATION #7 (NOT #9).NONE SELECTED. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES.CONTRACTOR | | | SPACIFIED ENHANCED FASTENING BUT THE APPROVED ASSEMBLY | | | MUST BE SELECTED BEFORE I CAN DO THE CALCULATIONS TO | | | DETERMINE CODE COMPLIANCE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-01 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-01 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2007-10-01 16:34:06 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LIST: | | | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES.CONTRACTOR | | | STATES THAT HE WILL INSTALL 12 ROWS AT 4" OC.THE | | | SHEET IS 39" WIDE; HAVING 12 ROWS CREATES ROWS WHICH | | | ARE LESS THAN 4" APART.THIS IS NOT ALLOWED AS PER | | | RAS117 (FASTENER SPACING TO BE A MINIMUM OF 4"). | | | PLEASE SELECT AN APPROVED ASSEMBLY AND SPECIFY ENHANCED | | | FASTENING IN ACCORDANCE WITH RAS117.CALCULATIONS MAY | | | BE REQUIRED. | | | | | | NEW COMMENT: | | | | | | ALL INFORMATION REQUIRED ON THE RESUB SHEET.YOU DID | | | NOT INCLUDE THE PERMIT NUMBER, BUT THIS IS HOW WE TRACK | | | THE APPLICATIONS AND SUBMITTALS.PLEASE ALWAYS INCLUDE | | | ALL REQUIRED INFORMATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-30 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-30 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2007-08-30 16:39:36 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | | | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | _XX_2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY; | | | MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF | | | EACH ROOF TYPE.TWO DIFFERENT PRODUCT APPROVALS | | | SUBMITTED; SPECIFY WHERE EACH WILL BE INSTALLED, OR | | | WILL ONE BE AN UNDERLAYMENT? | | | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | | | _XX_ 6.)TWO IDENTICAL SETS OF DOCUMENTS FOR PERMIT | | | ISSUANCE REQUIRED. | | | | | | ____ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2007-11-07 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2007-11-07 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2007-11-07 10:17:17 | HISTORICAL APPROVAL PER GALINA JUDGE |
|
|
|