Plan Review Details - Permit 07080884
Plan Review Stops For Permit 07080884
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-03-11 Cont ID  
Sent By rmcdouga Date 2008-03-11 Time 07:42 Rev Time 0.00
Received By rmcdouga Date 2008-03-11 Time 06:57 Sent To  
Notes
2008-03-11 07:44:37REVISED SHEETS 1 AND 2 AND NEW SHEET E1 HAVE BEEN
 REVIEWED FOR CODE COMPLIANCE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-02-27 Cont ID  
Sent By rmcdouga Date 2008-02-27 Time 07:45 Rev Time 0.00
Received By rmcdouga Date 2008-02-27 Time 07:09 Sent To  
Notes
2008-02-27 07:45:242004 FBC W/2007 REVISIONS
 LEVEL 3 ALTERATIONS
  
 REVISION DENIED BY BUILDING
  
 1) REVISED PLAN SUBMITTED IS ACTUALLY A NEW SHEET E1,
 WHICH WAS NOT ONE OF THE 3 SHEETS THAT WERE SUBMITTED
 AND REVIEWED FOR PERMIT.
  
 2) THE NEW SHEET E1 SHOWS A CHANGE IN THE EXTERIOR DOOR
 TYPE AND LOCATION. THE REVISIONS ARE REQUIRED TO BE
 SHOWN ON THE PERMIT SET OF PLANS. SHEETS 1 AND 2 ARE
 AFFECTED. FBC 106.1.3* CITY AMENDMENTS
  
 3) BECAUSE THE REVISION WILL CHANGE THE EXTERIOR OF THE
 STRUCTURE, THE REVISIONS WILL NEED TO HAVE A REVIEW BY
 HISTORIC PRESERVATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-10-25 Cont ID  
Sent By rmcdouga Date 2007-10-25 Time 17:48 Rev Time 0.00
Received By rmcdouga Date 2007-10-25 Time 17:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-22 Cont ID  
Sent By rmcdouga Date 2007-10-22 Time 08:55 Rev Time 0.00
Received By rmcdouga Date 2007-10-22 Time 08:55 Sent To  
Notes
2007-10-22 09:57:172004 FBC W/2007 SUPPLEMENTS
 LEVEL 3 ALTERATIONS
  
 DENIED BY BUILDING
  
 1)THE PRODUCT APPROVALS FOR THE MARVIN WINDOWS AND
 DOORS DO NOT HAVE THE DRAWINGS THAT CORRESPOND WITH THE
 FLORIDA COVERSHEETS. PLEASE SPECIFY THE ITEM THAT WILL
 BE INSTALLED ON THE FL COVERSHEET ATTACH THE
 CORRESPONDING DRAWINGS.
  
 2) THE NEW PAIR OF 6 ' WIDE DOUBLE OUTSWING DOORS AT
 THE FIRST FLOOR OF THE GARAGE APARTMENT IS NOT LISTED
 IN THE SCHEDULE ON SHEET 2 OF THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-05 Cont ID  
Sent By rmcdouga Date 2007-09-05 Time 08:54 Rev Time 0.00
Received By rmcdouga Date 2007-09-04 Time 18:40 Sent To E
Notes
2007-09-05 14:39:462004 FBC W/2007 SUPPLEMENTS
 LEVEL 3 ALTERATIONS
  
 DENIED BY BUILDING
  
 1) THE SCOPE OF WORK ON THE PERMIT APPLICATION DOES NOT
 INDICATE WINDOW AND DOOR REPLACEMENT FOR THE MAIN HOUSE
 AND THE NOC SPECIFIES THE GARAGE/APARTMENT ONLY. PLEASE
 REMOVE THE WINDOW AND DOOR INFORMATION FOR THE MAIN
 HOUSE FROM THE SUBMITTAL.
  
 2)SPECIFY THE WINDOW TYPES AND SIZES ON THE PLANS.
 FBC * 106.1.2
  
 3) SPECIFY THE WIDTH OF THE STAIRWAY ON THE
 PLANS.R311.5.1 STAIRWAYS SHALL NOT BE LESS THAN 36
 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE
 PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED
 HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN
 4.5 INCHES (114 MM) ON EITHER SIDE OF THE STAIRWAY AND
 THE MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW
 THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS,
 SHALL NOT BE LESS THAN 31.5 INCHES (787 MM) WHERE A
 HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698
 MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES.
  
 4) R 311.5.3.2 REQUIRES TREADS AND RISERS TO BE
 PROPORTIONED SO THAT THE SUM OF TWO RISERS AND A TREAD,
 EXCLUSIVE OF THE NOSING IS NOT LESS THAN 24 INCHES NOR
 MORE THAN 25 INCHES. SHOW COMPLIANCE.
  
 5) SHOW COMPLIANCE WITH R311.2.2 UNDER STAIR
 PROTECTION.
 ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE
 WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON
 THE ENCLOSED SIDE WITH1/2-INCH (12.7 MM) GYPSUM
 BOARD.
  
  
 6) SHOW COMPLIANCE WITH R311.4.1 AND R311.4.2 WHICH
 REQUIRE A SIDE HINGED EXIT DOOR NOT LESS THAN 3 FEET
 WIDE AND PROVIDING DIRECT ACCESS TO THE EXTERIOR
 WITHOUT TRAVELING THROUGH THE UTILITY/GARAGE.
  
 7)PROVIDE STRUCTURAL DETAILS SPECIFYING HOW THE 2 X 8
 FLOOR TRUSSES WILL BE SISTERED. SPECIFY THE FASTENERS,
 SPACING, ETC.
  
 8) PROVIDE DETAILS AND SECTIONS SHOWING THE
 CONSTRUCTION AND SUPPORT OF FLOOR JOISTS AT THE NEW
 STAIRWAY. IF THE JOISTS ARE SUPPORTED BY A BEARING WALL
 BESIDE THE STAIRS SPECIFY THE FOUNDATION REQUIREMENTS.
 IF THE 3 MEMBER 2 X 8 BEAM IS CARRYING THE FLOOR LOAD
 SPECIFY THE CONNECTIONS AT THE EXTERIOR WALLS AND
 INDICATE HOW THE GRAVITY LOADS WILL BE TRANSFERRED TO
 THE FOUNDATION.
  
 9) SPECIFY THE 2 X 8 JOIST SPACING AND SPANS. PLEASE
 REVIEW FOR ALLOWABLE DEFLECTION. SEE TABLE R 301.7.
 NOTE: TABLE R 301.5 REQUIRES A LIVE LOAD OF 30 PSF FOR
 SLEEPING ROOMS AND 40 PSF FOR OTHER ROOMS AND STAIRS.
  
  
 10) THERE APPEARS TO BE A CONFLICT WITH THE PROPOSED
 FLOOR PLAN AND THE STAIR SECTION. THE FLOOR PLAN SHOWS
 AN INTERIOR WALL BESIDE THE STAIRS AND THE STAIR
 SECTION SHOWS A WALL UNDER THE STAIR STRINGERS. PLEASE
 CLARIFY.
  
 11) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 12) THE PRODUCT APPROVAL FOR THE OVERHEAD GARAGE DOOR
 IS EXPIRED. SUBMIT TWO COPIES OF THE CURRENT PRODUCT
 APPROVALS. (NOA NO. 05-0915.08)
  
 13) THE PRODUCT APPROVALS FOR THE STOREFRONT DOOR IS
 EXPIRED AND INCOMPLETE. THERE ARE NOT ANY STOREFRONT
 DOORS SHOWN ON THE PLANS. SUBMIT TWO CURRENT AND
 COMPLETE PRODUCT APPROVALS FOR THE SINGLE AND DOUBLE
 OUTSWING DOORS.
  
 14)SUBMIT TWO COPIES OF THE COMPLETE NOA, INCLUDING
 THE INSTALLATION DRAWINGS FOR THE SINGLE HUNG WINDOWS.
 ONLY THE FIRST PAGE OF THE NOA WAS SUBMITTED.
  
 15) SUBMIT PRODUCT APPROVALS FOR LARGE MISSILE IMPACT
 RATED MULLIONS.
  
 16) R309.2 SEPARATION REQUIRED.
 THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND
 ITS ATTIC AREA BY NOT LESS THAN ? -INCH (12.7 MM)
 GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES
 BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL
 HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH
 (15.9 MM) TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE
 SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE STRUCTURE
 SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY
 NOT LESS THAN ?-INCH (12.7 MM) GYPSUM BOARD OR
 EQUIVALENT.
  
 17) SHOW COMPLIANCE WITH R309.2 SEPARATION REQUIRED.
 THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND
 ITS ATTIC AREA BY NOT LESS THAN ? -INCH (12.7 MM)
 GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES
 BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL
 HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH
 (15.9 MM) TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE
 SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE STRUCTURE
 SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY
 NOT LESS THAN ?-INCH (12.7 MM) GYPSUM BOARD OR
 EQUIVALENT.
  
 18) SHOW COMPLIANCE WITH R313 FOR SMOKE ALARMS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-03-06 Cont ID  
Sent By btrobaug Date 2008-03-06 Time 07:44 Rev Time 0.00
Received By btrobaug Date 2008-03-06 Time 06:47 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-02-26 Cont ID  
Sent By btrobaug Date 2008-02-26 Time 07:30 Rev Time 0.00
Received By btrobaug Date 2008-02-26 Time 06:32 Sent To P
Notes
2008-02-26 08:51:38 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
  
 1} THERE IS NO CONDENSER LOCATION FOR THE A/C SYSTEM
 BEING INSTALLED, LOCATE SAME ON THE PLAN. SHOW
 COMPLIANCE WITH 210.63 FOR THE RECEPTACLE, AND
 DISCONNECT PER 440.14.
  
 2} THE PANEL SCHEDULE LISTS TWO "ACCU" #1 AND #2. THERE
 SHOULD BE AN AHU LISTED AND ONE ACCU (A/C CONDENSING
 UNIT).
  
 3} THE SMALL APPLIANCE CIRCUITS REQUIRED BY 210.11(C)
 (1) ARE NOT LISTED ON THE PANEL SCHEDULE.
  
 4} VERIFY THE SERVICE CONSISTS OF A "METER/ MAIN"
 COMBINATION, AND A MAIN LUG PANEL, OR A STANDARD METER
 WITH A MAIN BREAKER PANEL.215.5 NEC 106.1.3 FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-10-11 Cont ID  
Sent By btrobaug Date 2007-10-11 Time 17:15 Rev Time 0.00
Received By btrobaug Date 2007-10-11 Time 17:08 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-09-06 Cont ID  
Sent By btrobaug Date 2007-09-06 Time 11:15 Rev Time 0.00
Received By btrobaug Date 2007-09-06 Time 10:47 Sent To P
Notes
2007-09-06 11:15:14 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE
 SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED.
  
 1} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND
 210.52(A)(2). 2005 NEC. LOCATE SAME ON THE PLAN.
  
 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 3} R313.1 SMOKE ALARMS.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1. IN EACH SLEEPING ROOM.
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
 BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND
 UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS
 WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR
 BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON
 THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
 LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE
 FULL STORY BELOW THE UPPER LEVEL.
 WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE
 INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM
 DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT
 THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE
 ALARMS IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE
 CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE
 LEVELS WITH ALL INTERVENING DOORS CLOSED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-03-05 Cont ID  
Sent By adarroug Date 2008-03-05 Time 16:22 Rev Time 0.00
Received By adarroug Date 2008-03-05 Time 16:22 Sent To E
Notes
2008-03-05 16:23:06TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-02-19 Cont ID  
Sent By adarroug Date 2008-02-19 Time 11:29 Rev Time 0.00
Received By adarroug Date 2008-02-19 Time 11:29 Sent To E
Notes
2008-02-19 11:29:33TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 12:17 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 12:17 Sent To E
Notes
2007-10-05 12:18:02TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-11 Cont ID  
Sent By jleech Date 2007-09-11 Time 10:05 Rev Time 0.00
Received By jleech Date 2007-08-30 Time 12:48 Sent To  
Notes
2007-08-30 12:50:34TO "SFR" "BLDG"

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-03-10 Cont ID  
Sent By jleech Date 2008-03-10 Time 07:28 Rev Time 0.00
Received By jleech Date 2008-03-10 Time 07:17 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-02-26 Cont ID  
Sent By jleech Date 2008-02-26 Time 12:25 Rev Time 0.00
Received By jleech Date 2008-02-26 Time 11:53 Sent To B
Notes
2008-02-26 12:40:21DENIED;
 1. SANITARY RISER DIAGRAM; THE LAVATORY AND SHOWER ARE
 NOT VENTED AS DRAWN.
 2. LIST MATERIAL TO BE USED. IS SANITARY ONLY OR IS
 WATER PIPE TO BE INSTALLED? LIST EXTENT OF PLUMBING
 WORK ON PLANS,WATER SERVICE, BACKFLOW PREVENTER, NEW
 SEWER ETC.
 3. AUTOMATIC CLOTHES WASHER IS REQUIRED OR THE ONE IN
 THE MAIN HOUSE MUST BE IN A COMMON AREA.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-09-11 Cont ID  
Sent By btrobaug Date 2008-02-26 Time 07:47 Rev Time 0.00
Received By jleech Date 2007-09-11 Time 10:04 Sent To  
Notes
2007-09-11 10:05:34FIXTURE CHANGE ONLY (GARAGE APARTMENT)