| Plan Review Stops For Permit 07080804 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-06-05 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-06-05 |
Time |
18:52 |
Sent To |
PC |
|
| Notes |
| 2008-06-05 18:53:24 | | | | | | | REVISION FOR AS BUILT CONDITION PASSED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-05-22 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-05-22 |
Time |
15:30 |
Sent To |
PC |
|
| Notes |
| 2008-05-22 15:31:30 | | | | | | | BUILDING SUBMITTAL FOR SHUTTERS AS REQUESTED; PASSED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-04-30 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-04-30 |
Time |
16:20 |
Sent To |
PC |
|
| Notes |
| 2008-04-30 16:40:50 | | | | | | | DENIED | | | | | | 1)PROVIDE A KEY PLAN WITH THE OPENINGS NUMBERED TO | | | COINCIDE WITH THE SHUTTER SCHEDULE OPENING NUMBERS, | | | THIS IS REQUIRED FOR INSPECTIONS. PLEASE NOTE THAT THE | | | OPENINGS ON THE SHUTTER SCHEDULE SEEM TO HAVE NO ORDER | | | IN RELATION TO DRAWINGS | | | | | | 2)PRESSURES FOR OPENINGS SHOULD MATCH THOSE ON SHEET | | | 1.3 OF DRAWINGS, IF LEFT AS IS, OPENING # 8 WILL NOT | | | WORK AS MAX DESIGN PRESSURE ALLOWED FOR THIS SHUTTER | | | SPAN IS -42 PSF PER SHEET # 2 OF PRODUCT APPROVAL | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-04-09 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-04-09 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2008-04-09 16:50:40 | | | | | | | "BUILDING PROVISO" | | | | | | | | | | | | A COMPLETED INSTALLATION SCHEDULE AND STORM SHUTTER | | | PRODUCT APPROVAL SHALL BE SUBMITTED FOR REVIEW BEFORE | | | C.O. | | | | | | | | | LUIS MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2008-04-05 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-04-05 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-04-05 |
Time |
11:09 |
Sent To |
E |
|
| Notes |
| 2008-04-05 11:14:34 | | | | | | | DENIED | | | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE 3RD | | | REVIEW | | | | | | 6)SHUTTERAPPLICATIONS REQUIRE A KEY PLAN (WITH | | | EGRESS SHOWN), SHUTTER SCHEDULE AND THE PRODUCT | | | APPROVALS. APPROVAL DRAWINGS SHALL BE MARKED FOR | | | MOUNTING METHOD AND CONNECTION TYPE AND THE SCHEDULE | | | FILLED OUT WITH ALL PERTINENT INFORMATION SPECIFIC TO | | | THE SITE (TYPE OF CONSTRUCTION, MOUNTING CONNECTION | | | METHOD, ANCHOR TYPE, SHUTTER SPAN (VERTICAL OR | | | HORIZONTAL), ETC.)***************PLEASE SEE THE | | | ATTACHED MEMO AND SCHEDULE.**************** | | | | | | *******NOTE******** | | | SHUTTER INSTALLATION: FASTENERS FOR FILLED CELL | | | BLOCK-WORK-CONTRACTOR CANNOT ASSUME THAT THERE IS A | | | CONCRETE SUBSTRATE WHEN SELECTING FASTENERS (AND | | | SPACING) UNLESS THEY CAN PROVIDE DOCUMENTATION TO | | | VERIFY COMPRESSIVE STRENGTH OF 3,000 PSI, OR 3,500 PSI, | | | ETC, AND THE REQUIRED FASTENER EMBEDMENT DEPTH,AS | | | REQUIRED ON THE PRODUCT APPROVAL. IF DOCUMENTATION IS | | | NOT PROVIDED THE SUBSTRATE SHALL BE CONSIDERED MASONRY | | | AND THE O/C SPACING SHALL BE ADJUSTED ACCORDINGLY. | | | | | | 7)PER 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN | | | THE NOC HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING, | | | THE NOTICE IS VOID, PLEASE HAVE RERECORDED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-03-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2008-03-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2008-03-18 18:58:44 | | | | | | | | | | 1)SIMONTON WINDOW PRODUCT APPROVAL DOES NOT COVER | | | DH36 SIZE (53 1/8" X 74 1/4") | | | | | | 2)SIMONTON SGD PRODUCT APPROVAL ONLY COVERS 3 LITE | | | UNIT IN 107" X 80" SIZE THE UNIT BEING REPLACE IS | | | 12'-0"WIDE (144") BY 8'-0" TALL (96") | | | | | | 3)PRODUCT APPROVALS AREA COMBINATION OF THE FLORIDA | | | STATEWIDE PRODUCT APPROVAL AND MIAMI-DADE NOA'S AND | | | NEITHER ONE MEETS THE SIZE REQUIREMENTS. | | | | | | 4)PROVIDE ONLY THE APPROVALS THAT WILL MEET YOUR | | | REQUIREMENTS FROM ONE ENTITY, THE CITY OF WEST PALM | | | REQUIRES THE STATEWIDE APPROVALS WHEN AVAILABLE IF NOT | | | MIAMI-DADE NOA'S WILL BE GIVEN LOCAL PRODUCT APPROVAL. | | | | | | 5)IN EXISTING BUILDINGS WHERE MORE THAN 25% OF THE | | | AGGREGATE AREA OF GLAZED OPENINGS ARE BEING REPLACED IN | | | ANY 12 MONTH PERIOD IMPACT PROTECTION IS REQUIRED PER | | | 507.3 FBC EXISTING. | | | | | | 6)SHUTTERAPPLICATIONS REQUIRE A KEY PLAN (WITH | | | EGRESS SHOWN), SHUTTER SCHEDULE AND THE PRODUCT | | | APPROVALS. APPROVAL DRAWINGS CAN BE MARKED FOR MOUNTING | | | METHOD AND CONNECTION TYPE AND THE SCHEDULE FILLED OUT | | | WITH ALL PERTINENT INFORMATION SPECIFIC TO THE SITE | | | (TYPE OF CONSTRUCTION, MOUNTING CONNECTION METHOD, | | | ANCHOR TYPE, SHUTTER SPAN (VERTICAL OR HORIZONTAL), | | | ETC.) PLEASE SEE THE ATTACHED MEMO AND SCHEDULE. | | | | | | *******NOTE******** | | | SHUTTER INSTALLATION: FASTENERS FOR FILLED CELL | | | BLOCK-WORK-CONTRACTOR CANNOT ASSUME THAT THERE IS A | | | CONCRETE SUBSTRATE WHEN SELECTING FASTENERS (AND | | | SPACING) UNLESS THEY CAN PROVIDE DOCUMENTATION TO | | | VERIFY COMPRESSIVE STRENGTH OF 3,000 PSI, OR 3,500 PSI, | | | ETC, AND THE REQUIRED FASTENER EMBEDMENT DEPTH,AS | | | REQUIRED ON THE PRODUCT APPROVAL. IF DOCUMENTATION IS | | | NOT PROVIDED THE SUBSTRATE SHALL BE CONSIDERED MASONRY | | | AND THE O/C SPACING SHALL BE ADJUSTED ACCORDINGLY. | | | | | | 7)PER 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN | | | THE NOC HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING, | | | THE NOTICE IS VOID, PLEASE HAVE RERECORDED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-11-29 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-11-29 |
Time |
18:00 |
Sent To |
PC |
|
| Notes |
| 2007-11-29 18:04:22 | | | | | | | PASSED | | | | | | 1)ADDITIONAL PERMIT FEES ARE REQUIRED IN THE AMOUNT | | | OF $571.31 DUE TO INCREASED VALUE BASED ON MARSHALL & | | | SWIFT GUIDE FOR INTERIOR RESIDENTIAL RENOVATIONS. THIS | | | FEE WILL BE REQUIRED BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)AS WITH ELECTRICAL AND PLUMBING REVIEWERS COMMENTS | | | THE 2ND SET OF DRAWINGS IS REQUIRED TO BE SIGNED AND | | | SEALED BY RESPONSIBLE ENGINEER AND COMMENTS ADDRESSED | | | BEFORE FINAL PERMIT STAMPS CAN BE ADDED AND PERMIT | | | PRINTED | | | BLDG PLAN REVIEW | | | | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-22 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-09-22 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-09-22 |
Time |
15:11 |
Sent To |
PC |
|
| Notes |
| 2007-09-22 15:53:42 | | | | | | | DENIED | | | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS PER 106.1.1 FBC* | | | | | | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | | | | 3)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE, AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1 | | | FBC*. NO EXISTING LAYOUT IS SHOWN, IS SHOWER DOOR #6 | | | FROM EXISTING 2'-6" X 4'-2"SHOWER ? AND ARE NEW | | | SHOWER WALLS GLAZED ? | | | | | | 4)PROVIDE COMPLETE SCOPE OF WORK- DEMOLITION, | | | CONSTRUCTION, NEW FIXTURES, NEW KITCHEN, NEW FLOORING. | | | THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS LOW. | | | FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING | | | LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD), | | | MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC*. | | | | | | 5)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-04 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-04 |
Time |
14:58 |
Sent To |
B |
|
| Notes |
| 2008-06-04 16:16:01 | | | | | | | REVISION AND FILE COPY TO ADRIAN'S DESK./WRT. | | 2008-06-04 16:15:08 | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
N |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-19 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-19 |
Time |
09:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-08 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-08 |
Time |
07:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-12 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-12 |
Time |
15:26 |
Sent To |
P |
|
| Notes |
| 2008-03-12 15:55:53 | | | | | | | | | | | | | PROVISO | | | | | | THESE ISSUES MUST BE CORRECTED AND PLANS RESUBMITTED | | | FOR REVIEW PRIOR TO CALLING A ROUGH ELECTRICAL | | | INSPECTION. | | | | | | 1} BATH CIRCUITS ARE REQUIRED TO HAVE A 20 AMP | | | RECEPTACLE PER 210.11(C) (3), LOCATED PER 210.52(D), | | | AND BE GFI PROTECTED PER 210.8(A) (1). CIRCUIT #17 IN | | | THE MASTER BATH IS NOT RATED ON THE PANEL SCHEDULE, | | | THEY COULD BE ON 23 AS THAT CIRCUIT MEETS THE INTENT OF | | | THE EXCEPTION 210.11(C) (3). | | | | | | 2} THE "EXISTING BATH", SAME COMMENT AS ABOVE WITH | | | CIRCUITS19 AND 25. | | | | | | 3} PER 210.52(B) (1) & (2), THE CIRCUITS IN THE DINING | | | ROOM (# 27)MUST BE 20 AMP AS IT IS, BUT MUST BE | | | LABLED "DINING ROOM", NOT "GENERAL LIGHTING. ALSO | | | "SHALL HAVE NO OTHER OUTLETS" MEANS THE LIVING ROOM IS | | | IN VIOLATION BEING ON THE SAME CIRCUIT. | | | | | | 4}THE LIGHTING IN THE KITCHEN SHALL NOT BE ON A SMALL | | | APPLIANCE CIRCUIT, 210.52(B) (2). | | | | | | 5} CIRCUIT #6 IS LABLED "COOK TOP" ON THE SCHEDULE AND | | | "DOUBLE OVEN" ON THE PLAN, CORRELATE SAME. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-21 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-21 |
Time |
07:41 |
Sent To |
P |
|
| Notes |
| 2007-11-21 08:07:26 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THIS COMMENT IS FROM THE 9/5/07 REVIEW; | | | | | | 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | | PROTECTED PER 210.8(A) (1). THAT CIRCUIT(S) IS NOT | | | SHOWN ON THE IN THE PANEL SCHEDULE. * THE CIRCUIUT IS | | | NOW SHOWN---AT 15 AMPS. PLEASE READ THE COMMENT THEN | | | REVIEW THE ARTICLE FOR CLARIFICATION. | | | | | | THESE ARE COMMENTS GENERATED FROM THE PLANS SUBMITTED | | | 11/15/07. | | | | | | 1} THE NOTE ON SHEET E-1 AT THE LOAD CALCULATIONS | | | INDICATES THE SERVICE IS 200 AMPS, THE FEEDERS ARE | | | INDICATED AS 1/0 WHICH PER 310.15(B)(6) IS RATED FOR | | | 175 AMPS. PLEASE FIELD VERIFY ACTUAL CONDITIONS AND | | | CORRECT THE PLAN. | | | | | | 2} THE ENGINEER OF RECORD MUST SEAL THE DOCUMENTS WITH | | | A SEAL ACCEPTABLE TO THE BOARD PER 61G15-23.001. ONLY | | | ONE SET OF PLANS ARE SEALED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-05 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-05 |
Time |
08:49 |
Sent To |
M |
|
| Notes |
| 2007-09-05 09:05:50 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | | INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS | | | SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE | | | COMPLIANCE ON THE PLAN. | | | | | | 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | | PROTECTED PER 210.8(A) (1). THAT CIRCUIT(S) IS NOT | | | SHOWN ON THE IN THE PANEL SCHEDULE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-27 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-27 |
Time |
14:24 |
Sent To |
E |
|
| Notes |
| 2008-05-27 14:25:02 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-08 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-08 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2008-05-08 14:53:58 | TO "BTROBAUG" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-24 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-24 |
Time |
15:48 |
Sent To |
B |
|
| Notes |
| 2008-04-24 15:48:49 | TO "AMORSE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-02 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-02 |
Time |
10:32 |
Sent To |
E |
|
| Notes |
| 2008-04-02 10:33:22 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-11 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-11 |
Time |
14:09 |
Sent To |
E |
|
| Notes |
| 2008-03-11 14:09:31 | TO "BTROBAUG" DESK/RESUB--NE SHEETS FOR "BLDG" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-15 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-15 |
Time |
13:30 |
Sent To |
E |
|
| Notes |
| 2007-11-15 13:30:58 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-28 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2007-08-28 16:06:17 | TO "SFR" "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-06 |
Time |
10:37 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-09-06 |
Time |
10:37 |
Sent To |
P |
|
| Notes |
| 2007-09-06 10:37:47 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-20 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-13 |
Time |
08:19 |
Sent To |
B |
|
| Notes |
| 2008-03-13 08:33:15 | ****************PROVISO**************** | | | A} WATER SEAL TRAPS ARE REQUIRED FOR THE NEW LAVS IN | | | THE MASTER BATH. PER FBC PLUMBING SECTION 1002.1 | | | FIXTURE TRAPS. | | | | | | B} PER FBC PLUMBING SECTION 802.1.6 THE NEW DOMESTIC | | | DISHWASHING MACHINE SHALL DISCHARGE INDIRECTLY THROUGH | | | AN AIR GAP OR AIR BREAK INTO A STANDPIPE OR WASTE | | | RECEPTOR IN ACCORDANCE WITH SECTION 802.2 OR DISCHARGE | | | INTO A WYE-BRANCH FITTING ON THE TAILPIECE OF THE | | | KITCHEN SINK OR THE DISHWASHER CONNECTION OF A FOOD | | | WASTE GRINDER. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-11-29 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-11-29 |
Time |
08:11 |
Sent To |
B |
|
| Notes |
| 2007-11-29 08:17:43 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS | | | TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A-4 PLUMBING RISER DIAGRAM: THE TUB AND | | | SHOWER REQUIRE TRAPS. PER *1002.1 FIXTURE TRAPS. | | | | | | 2. THE ENGINEER OF RECORD MUST SEAL THE DOCUMENTS WITH | | | A SEAL ACCEPTABLE TO THE BOARD PER F.A.C. 61G15-23.001 | | | AND F.S. 471.025. | | | **NOTE: ONLY ONE SET OF PLANS WERE SEALED. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-14 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-14 |
Time |
11:40 |
Sent To |
B |
|
| Notes |
| 2007-09-14 13:33:35 | DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING WITH 2006 REVISIONS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET A-3 FLOOR PLAN: CLEARLY IDENTIFY ALL PLUMBING | | | FIXTURES IN THE MASTER BATH PER FBC-2004 CHAPTER 1, | | | SECTION 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | | | | 2. SHEET A-4 PLUMBING RISER DIAGRAM KITCHEN PLEASE | | | CORRECT THE FOLLOWING: | | | | | | A} A SANITARY TEE IS NOT ALLOWED ON THE KITCHEN SINK | | | FOR HORIZONTAL TO HORIZONTAL DRAINAGE PER FBC-2004 | | | PLBG. TABLE 706.3. | | | | | | B} A DRAIN FOR THE DISHWASHER IS REQUIRED AND NEEDS TO | | | BE INDICATED IN THE RESUBMITTED RISER DIAGRAM PER | | | FBC-2004 PLBG. SECTION 802.1.6,DOMESTIC DISHWASHING | | | MACHINES SHALL DISCHARGE INDIRECTLY THROUGH AN AIR GAP | | | OR AIR BREAK INTO A STANDPIPE OR WASTE RECEPTOR IN | | | ACCORDANCE WITH SECTION 802.2 OR DISCHARGE INTO A | | | WYE-BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN SINK | | | OR THE DISHWASHER CONNECTION OF A FOOD WASTE GRINDER. | | | | | | 3. SHEET A-4 PLUMBING RISER DIAGRAM MASTER BATH PLEASE | | | CORRECT THE FOLLOWING: | | | | | | A} A VENT IS REQUIRED FOR BOTH THE TUB AND SHOWER PER | | | FBC-2004 PLBG. TABLE 906.1, THE 2 INCH TRAPS CAN NOT BE | | | MORE THAN 6 FEET FROM THE VENT. THE TRAPS ARE NOW | | | AROUND 8 FEET FROM THE VENT. | | | | | | B} A SANITARY TEE IS NOT ALLOWED ON THE LAVATORIES FOR | | | HORIZONTAL TO HORIZONTAL DRAINAGE PER FBC-2004 PLBG. | | | TABLE 706.3. | | | | | | C} SEND MANUFACTURER SPECIFICATION SHEET OF THE | | | CIRCLED FITTING PER FBC-2004 CHAPTER 1, SECTION | | | 106.1.1, INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK | | | ON THE INDICATED PLAN SHEETS BY THIS PLANS EXAMINER FOR | | | REFERENCE FOR THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|