Plan Review Details - Permit 07080761
Plan Review Stops For Permit 07080761
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-10-23 Cont ID  
Sent By amorse Date 2007-10-23 Time 15:06 Rev Time 0.00
Received By amorse Date 2007-10-23 Time 15:06 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-22 Cont ID  
Sent By amorse Date 2007-09-22 Time 13:46 Rev Time 0.00
Received By amorse Date 2007-09-22 Time 13:46 Sent To PC
Notes
2007-09-22 14:12:38 
  
 DENIED
  
 1)PROVIDE SMOKE ALARM ON EACH STORY OF DWELLING PER
 R313.1 (3) FBC RES.
  
 2)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-10-23 Cont ID  
Sent By btrobaug Date 2007-10-23 Time 07:45 Rev Time 0.00
Received By btrobaug Date 2007-10-23 Time 06:49 Sent To B
Notes
2007-10-23 07:46:06 
  
 TO ADRIAN'S DESK./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-09-05 Cont ID  
Sent By btrobaug Date 2007-09-05 Time 08:01 Rev Time 0.00
Received By btrobaug Date 2007-09-05 Time 07:13 Sent To M
Notes
2007-09-05 08:01:24 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
  
 1} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE
 COMPLIANCE ON THE PLAN.
  
 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1). THE MASTER BATH HAS A
 SECOND SINK AND MUST HAVE A RECEPTACLE ADDED PER
 210.52(D), OR MOVE THEW EXISTING ONE TO COMPLY WITH THE
 3' MAXIMUM SPACE REQUIREMENT.
  
 3} PER SECTION 608 AND 608.3 EXISTING BUILDING CODE,
 SHOW REQUIRED RECEPTACLE SPACING IN THOSE AREAS. 210.52
 2005 NEC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-15 Cont ID  
Sent By adarroug Date 2007-10-15 Time 09:45 Rev Time 0.00
Received By adarroug Date 2007-10-15 Time 09:45 Sent To E
Notes
2007-10-15 09:45:47TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-09-22 Time   Rev Time 0.00
Received By adarroug Date 2007-08-28 Time 09:21 Sent To  
Notes
2007-08-28 09:22:18TO "SFR" "E"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-09-06 Cont ID  
Sent By tgordon Date 2007-09-06 Time 10:04 Rev Time 0.20
Received By tgordon Date 2007-09-06 Time 10:04 Sent To P
Notes
2007-09-06 10:05:08BATHROOM EXHAUST FAN ONLY.

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-09-14 Cont ID  
Sent By mperson Date 2007-09-14 Time 09:20 Rev Time 0.00
Received By mperson Date 2007-09-14 Time 09:20 Sent To B
Notes
***NONE***