Plan Review Details - Permit 07080751
Plan Review Stops For Permit 07080751
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-09-11 Cont ID  
Sent By shill Date 2007-09-11 Time 14:39 Rev Time 0.00
Received By shill Date 2007-09-11 Time 14:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-02 Cont ID  
Sent By shill Date 2007-09-02 Time 17:42 Rev Time 0.00
Received By shill Date 2007-09-02 Time 17:42 Sent To  
Notes
2007-09-02 17:45:45****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
  
 1.)SHUTTER CONNECTION MOUNTING TYPE SHOULD BE A
 THROUGH L (CORRELATES WITH ANCHOR SCHEDULE).
  
 2.)SEE SHEET 14.1 1/2" EDGE DISTANCE NOT ALLOWED.
  
 3.)YOU'VE DECLARED A BUILDING HEIGHT OF 30'.IT
 APPEARS TO BE AT LEAST A 5 STORY BUILDING.PLEASE
 ADDRESS.ENGINEERING MAY BE REQUIRED.
  
 4.)DESIGN PRESSURES TOO LOW, FBC TABLE 1609.6.2.1(2).
 THIS IS EXPOSURE C.REVISE.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-06 Cont ID  
Sent By adarroug Date 2007-09-06 Time 16:22 Rev Time 0.00
Received By adarroug Date 2007-09-06 Time 16:21 Sent To B
Notes
2007-09-06 16:22:30TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-02 Cont ID  
Sent By shill Date 2007-09-02 Time 17:45 Rev Time 0.00
Received By shill Date 2007-08-27 Time 15:23 Sent To  
Notes
2007-08-27 15:23:35TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved