Plan Review Details - Permit 07080716
Plan Review Stops For Permit 07080716
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-12-17 Cont ID  
Sent By jwitmer Date 2007-12-17 Time 11:24 Rev Time 0.77
Received By jwitmer Date 2007-12-17 Time 11:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-20 Cont ID  
Sent By jwitmer Date 2007-09-20 Time 10:53 Rev Time 0.00
Received By jwitmer Date 2007-09-20 Time 11:52 Sent To  
Notes
2007-09-20 16:10:42BUILDING PLAN REVIEW
 PERMIT: 07080716
 ADD: 315 S FLAGLER DR
 CONT: ?PLAN REVIEW?
 TEL: (561)655-8544
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT
 STATEMENT ---
 PLEASE DO
 NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) PLANS SUBMITTED FOR PERMIT APPLICATION AFTER JULY
 1,2007 (BUILDING) WILL BE REVIEWED UNDER THE 2004 FBC
 WITH THE 2007 REVISIONS. PLEASE SEE CS-01 APPLICABLE
 CODES AND CORRECT.
  
 4) SHEET CS-01 BUILDING OCCUPANCY CLASSIFICATION,
 PLEASE CORRECT THE BUILDING TYPE,
 THE PLANS DO NOT INDICATE WHAT TYPE OF OCCUPANCY IS
 ABOVE THE 4TH FLOOR, THE I-2 OCCUPANCY ONLY ALLOWS
 4FLOORS WITH AN ADDITIONAL STORY FOR A FULLY SPRINKLED
 BUILDING.
 THE CLASSIFICATION OF A **IA** BUILDING WOULD PROVIDE
 UNLIMITED HEIGHT. PLEASE REVIEW BUILDING TYPE. THIS
 WILL EFFECT THE FLOOR CEILING PENETRATIONS BY ONE HOUR,
 SEE TABLE 601.
  
 5)THE FLOOR CEILING ASSEMBLY MAY POSSIBLY HAVE NEW
 PENETRATIONS THROUGH THE RATED
 ASSEMBLY.PLEASE PROVIDE PRODUCT INFORMATION FOR THE
 FIRESTOP SYSTEM FOR THROUGH-PENETRATIONS. SEE 712.4.2.
  
 6) SHEET A-02 INDICATES THE USE OF CROWN MOLDINGS AND
 CHAIR RAIL SYSTEM, PLEASE INDICATE THE TYPE OF
 MATERIALS FOR THE TRIM PACKAGE. SEE 805.3 & 2604.2.
  
 7) COMBUSTIBLE DECORATIONS IN I-2 OCCUPANCIES. 805.1
 GENERAL.
 IN OCCUPANCIES OF GROUPS A, E, I, R-1 AND DORMITORIES
 IN GROUP R-2, CURTAINS, DRAPERIES, HANGINGS AND OTHER
 DECORATIVE MATERIALS SUSPENDED FROM WALLS OR CEILINGS
 SHALL BE FLAME RESISTANT IN ACCORDANCE WITH SECTION
 805.2 AND NFPA 701 OR NONCOMBUSTIBLE.
 IN GROUPS I-1 AND I-2 , COMBUSTIBLE DECORATIONS SHALL
 BE FLAME RETARDANT UNLESS THE DECORATIONS, SUCH AS
 PHOTOGRAPHS AND PAINTINGS, ARE OF SUCH LIMITED
 QUANTITIES THAT A HAZARD OF FIRE DEVELOPMENT OR SPREAD
 IS NOT PRESENT. IN GROUP I-3, COMBUSTIBLE DECORATIONS
 ARE PROHIBITED.
  
 8) SHEET A-03 SOUND INSULATION, THE PLANS INDICATE A
 NOTE# 3, NOT FOUND ON THIS SHEET.
 PLEASE PROVIDE PRODUCT INFORMATION.719.2 CONCEALED
 INSTALLATION.
 INSULATING MATERIALS, WHERE CONCEALED AS INSTALLED IN
 BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A
 FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A
 SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450.
  
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
  
  
  
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-12-03 Cont ID  
Sent By dpalmer Date 2007-12-03 Time 14:20 Rev Time 0.00
Received By dpalmer Date 2007-12-03 Time 14:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-09-16 Cont ID  
Sent By dpalmer Date 2007-09-16 Time 12:47 Rev Time 0.00
Received By dpalmer Date 2007-09-16 Time 12:20 Sent To  
Notes
2007-09-16 12:48:012007-09-16 12:48:01
  
 ** DENIED **
  
 ** PLEASE KNOW THERE ARE ONLY MINOR COMMENTS AT THIS
 TIME.
  
 1) NOTE:PLEASE SEE PROJECT IS ONLY SUBMITTED FOR
 *PLAN REVIEW* AND HAS NOT BEEN SUBMITTED FOR PERMIT
 APPLICATION.
 REVIEW STATUS WILL REMAIN IN *FAILED* STATUS UNTIL
 PERMIT APPLICATION AHS BEEN MADE EVEN WHEN PLANS ARE
 CODE COMPLIANT AND OK WITH CODE REVIEW.
 LICENSING, ETC IS VERIFIED AT TIME OF APPLICATION ETC
 BEFORE ISSUANCE FOR CONTRACTORS, DESIGNERS ETC.
 PLEASE PROVIDE THE ADDRESS OF LOCATION OF PROJECT ON
 PLANS. PLEASE SEE THE ADDRESS OF THE APPLIED LOCATION
 IS 315 S FLAGLER DR.
 FAC 61G1-16.004, 61G15-23.002,
 FBC ADMIN SECT, 106.1.2, 106.3.5.1.2, 110.1.2 ETC
  
 2) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH
 ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS
 UNDER THE NEW CODES ADOPTED BY THE STATE.
 PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO
 THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS
 REVIEWER AT A MINIMUM.
 2004 FBC W/ 2006 REVISIONS
 2005 NFPA-70
 2002 NFPA-72
 2003 NFPA-101
  
 SOME ARE SHOWN; HOWEVER THE 2002 NEC IS BEING
 INDICATED.
  
 2) NOTE: PLEASE CLARIFY RISER AS SHOWN. THE FEEDERS
 SHOWN ARE IN DARK LINES LIKE THEY ARE BEING REPLACED
 AND SOME ARE NOTED TO HAVE *EQUIPMENT GROUNDING
 CONDUCTORS8 BEING PULLED IN.
 PLEASE CLARIFY WHICH SCOPE OF WORK IS BEING PERFORMED.
 ARE ALL AS SHOWN WITH DARK LINES BEING RE-PULLED? ** AS
 A NOTE: PLEASE SEE HOUSE BILL 7121 PASSED 7/19/06 WHICH
 MAY AFFECT THIS BUILDING. THIS IS ONLY NOTED AND IS
 BEING HANDLED THROUGH THE STATE. THIS IS FOR
 INFORMATIONAL PURPOSE ONLY.
  
 3) NOTE: PLEASE SEE LIGHTING CONTROL DEVICES BEING
 REPLACED TO MEET 13-415.1.ABC.1.2, 13-101. PLEASE
 VERIFY THE TYPE OF LIGHTING CONTROLS BEING INSTALLED
 AND USE IN AREAS.
  
 4) NOTE: PLEASE PROVIDE THE MAXIMUM LIGHTING POWER
 DENSITIES FOR THE ROOMS/SPACES WITH NEW LIGHTING
 FIXTURES.
 13-415.2
  
 5) NOTE: THE MINIMUM CANDELA LEVELS WERE FOUND ON SHEET
 E3.2 FOR FBC CHAPTER 11 ADA, HOWEVER PLEASE CLARIFY
 LEVELS FOR HORNS.
 11-4.28,.1, .2 AND.3.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS.
  
 ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW.
  
 *** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS
 OR COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE.
 IF THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY
 WAY, NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR,
 PLEASE DO NOT HESITATE IN CONTACTING THIS OFFICE AND
 THIS REVIEWER.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-12-20 Cont ID  
Sent By mawillia Date 2007-12-20 Time 11:57 Rev Time 0.00
Received By mawillia Date 2007-12-20 Time 10:55 Sent To B
Notes
2007-12-20 10:57:58*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ACKNOWLEDGED/ADDRESSED;PLAN SHEETS A-01, FP2.1,
 AND E2.1 WERE STAMPED, INITIALED, AND DATED.
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-10-23 Cont ID  
Sent By mawillia Date 2007-10-23 Time 12:26 Rev Time 0.00
Received By mawillia Date 2007-10-23 Time 11:10 Sent To  
Notes
2007-10-23 11:54:10*****DENIED*****
  
  
 1.THE ADDRESS SHALL BE IN THE TITLE BLOCK OF EACH
 SUBMITTED PLAN SHEET.
  
 2.ON SHEET CS-01 UNDER THE APPLICABLE NFPA CODES,
 STANDARDS, AND GUIDELINES SECTION, AMEND TO REFLECT
 NFPA 75 - 2003 EDITION AND NFPA 780 - 2004 EDITION ARE
 BEING REFERENCED.
  
 3.THE BUILDING OR PORTION OF THE BUILDING SHALL BE
 PERMITTED TO BE OCCUPIED DURING THIS SCOPE OF WORK ONLY
 WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE
 PROTECTION FEATURES ARE IN PLACE AND MAINTAINED.
  
 4.SPECIFY THE INTERIOR FINISH MATERIAL FOR THE NEW
 WALL AND CEILING IN TERMS OF CLASS A, CLASS B, OR CLASS
 C.
  
 5.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE
 FIRE SPRINKLER AND/OR THE FIRE ALARM SYSTEM REMODEL.
  
 6.WHEN/IF IT IS NECESSARY TO SHUT DOWN THE FIRE
 PROTECTION SYSTEM DUE TO AN ALTERATION OR MODIFICATION,
 THE FIRE DEPARTMENT SHALL BE NOTIFIED WHEN THE SYSTEM
 IS SHUT DOWN AND WHEN IT IS RETURNED TO SERVICE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-01-31 Cont ID  
Sent By adarroug Date 2008-01-31 Time 15:53 Rev Time 0.00
Received By adarroug Date 2008-01-31 Time 15:53 Sent To M
Notes
2008-01-31 15:53:44TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-01-07 Cont ID  
Sent By shill Date 2008-01-07 Time 16:34 Rev Time 0.00
Received By shill Date 2008-01-07 Time 16:34 Sent To P
Notes
2008-01-07 16:34:43TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-11-21 Cont ID  
Sent By adarroug Date 2007-11-21 Time 09:12 Rev Time 0.00
Received By adarroug Date 2007-11-21 Time 09:12 Sent To  
Notes
2007-11-30 13:45:29TO "COMM" BD#47
2007-11-21 09:12:18WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-10-23 Cont ID  
Sent By mawillia Date 2007-10-23 Time 11:11 Rev Time 0.00
Received By mawillia Date 2007-08-27 Time 10:27 Sent To  
Notes
2007-09-16 12:21:10TO COMM BOARD SPACE #60, DV P.
2007-08-27 10:27:51WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-02-01 Cont ID  
Sent By tgordon Date 2008-02-01 Time 11:02 Rev Time 0.30
Received By tgordon Date 2008-02-01 Time 11:02 Sent To  
Notes
2008-02-01 11:02:42REVISION TO MECH. PLAN PAGE M2.1.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-12-11 Cont ID  
Sent By tgordon Date 2007-12-11 Time 13:37 Rev Time 0.30
Received By tgordon Date 2007-12-11 Time 13:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-12-11 Cont ID  
Sent By hmoser Date 2007-10-04 Time 17:39 Rev Time 0.00
Received By tgordon Date 2007-10-04 Time 17:28 Sent To  
Notes
2007-10-04 17:38:55PLEASE PROVIDE THE LEVEL OF ALTERATION YOU ARE DOING
 1,2 OR 3
 PLEASE CHECK THE OUT SIDE AIR CALCULATIONS IN THE
 DINING AREA.
 PLESAE PROVIDE EXHAUST FAN DUCT SIZE FOR EF 17 PAGE
 M2.1.
 PLEASE PROVIDE A EXHAUST FAN AND EQUIPMENT SCHEDULE ON
 THE PLANS .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-01-08 Cont ID  
Sent By mperson Date 2008-01-08 Time 16:35 Rev Time 0.00
Received By mperson Date 2008-01-08 Time 16:35 Sent To  
Notes
2008-01-08 16:42:00NOTE: ONLY ONE STAMPED SHEET BY HEALTH DEPT, DIVISION
 OF ENVIRONMENTAL HEALTH SUBMITTED.
 PERMIT TO BE PRINTED WHEN 2ND STAMPED SHEET BY HEALTH
 DEPT, DIVISION OF ENVIRONMENTAL HEALTH SUBMITTED.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-12-14 Cont ID  
Sent By kstevens Date 2007-12-14 Time 17:03 Rev Time 0.00
Received By kstevens Date 2007-12-13 Time 14:59 Sent To  
Notes
2007-12-14 17:06:11PLUMBING PLANS ARE APPROVED BUT SHALL STAY IN FAILED
 STATUS UNTIL REVIEW AND APPROVAL BY THE PALM BEACH
 COUNTY HEALTH UNIT. PLEASE ROUTE PLANS TO THE PALM
 BEACH COUNTY HEALTH UNIT, DIVISION OF ENVIRONMENTAL
 HEALTH. 901 EVERNIA STREET, WPB, FLA. (561) 355-3018.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-10-30 Cont ID  
Sent By kstevens Date 2007-10-30 Time 08:52 Rev Time 0.00
Received By kstevens Date 2007-10-30 Time 08:52 Sent To  
Notes
2007-10-30 08:53:23SECTION 704.5 DEAD ENDS PROHIBITED.

Review Stop Z ZONING
Rev No 2 Status N Date 2007-12-05 Cont ID  
Sent By aaponte Date 2007-12-05 Time 16:13 Rev Time 0.00
Received By aaponte Date 2007-12-05 Time 16:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-10-04 Cont ID  
Sent By aaponte Date 2007-09-28 Time 11:06 Rev Time 0.00
Received By aaponte Date 2007-09-28 Time 11:06 Sent To  
Notes
2007-09-28 11:06:53INTERIOR RENOVATION. DOES NOT REQUIRE ZONING.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved