Plan Review Details - Permit 07080594
Plan Review Stops For Permit 07080594
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2007-09-12 Cont ID  
Sent By lursu Date 2007-09-12 Time 11:28 Rev Time 0.00
Received By lursu Date 2007-09-12 Time 11:28 Sent To  
Notes
2007-09-12 11:31:18ON THE PERMIT APPLICATION AND ARCHITECTURAL PLANS
 SPECIFY THE UNIT NUMBER WHERE THE WORK IS PERFORMED.
 IF YOU HAVE QUESTIONS PLEASE CALL.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-08 Cont ID  
Sent By mjacobs Date 2007-09-08 Time 13:37 Rev Time 0.00
Received By mjacobs Date 2007-09-08 Time 11:03 Sent To  
Notes
2007-09-08 13:37:07BUILDING PLAN REVIEW
 PERMIT: 07080594
 ADD: 300 CLEMATIS ST. 2ND FL.
 CONT:
 TEL: (561)833-1661
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)SUBMIT THE ENTIRE 2ND FLOOR PLAN SHOWING THE
 OCCUPANT LOAD AND USE OF THE OTHER AREAS ON THAT FLOOR.
 IT APPEARS THAT THE ONE OF THE EGRESS DOORS WILL BE
 SHARED WITH OTHER OCCUPANTS OTHER THAN THOSE STATED ON
 THE PLANS. THIS INFORMATION IS REQUIRED TO ASSURE THE
 BUILDING DEPT. THE EXISTING EGRESS DOOR HAS THE
 CAPABILITY OF HANDLING THE TOTAL OCCUPANT LOAD ON THE
 SECOND FLOOR.
  
 3)STATE ON THE PLANS SPECIFICALLY WHAT GRADE(S) THE
 STUDENTS ARE IN WHO WILL BE TUTORED. ANY EDUCATIONAL
 OCCUPANCY ABOVE THE 12TH GRADE IS CONSIDERED AS A
 BUSINESS (GROUP B).FBC 304.
  
 4)ALL ROOMS AND SPACES SHALL BE DIMENSION AND LABELED
 INDICATING THE USE OF THE AREA. FBC.106.1.1
  
 5)FBC 1016.2(EXCEPTION #4) IN GROUP E THE WIDTH OF A
 CORRIDOR SHALL BE 72? WHEN THE OCCUPANT LOAD IS 100 OR
 MORE.
  
 6)2004 FBC EXISTING. IF ANY TYPE OF ALTERATION IS
 MADE IN THE SPACE, THE INFORMATION BELOW WILL BE
 REQUIRED.
 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 7)IF THERE IS THE NEED FOR ANY WORK IN THIS AREA, A
 CERTIFIED CONTRACTOR SHALL BE HIRED DO THE WORK AND
 HIS/HER INFORMATION SHALL BE INDICATED ON THE
 APPLICATION. A FAIR MARKET VALUE SHALL ALSO BE
 INDICATED ON THE APPLICATION.
  
 8)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS
 A RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-09-08 Cont ID  
Sent By dpalmer Date 2007-09-08 Time 21:11 Rev Time 0.00
Received By dpalmer Date 2007-09-08 Time 20:15 Sent To  
Notes
2007-09-08 21:11:352007-09-08 21:11:35
  
 ** DENIED **
  
  
  
 1) NOTE:PLEASE KNOW THAT THE CHANGE IN OCCUPANCY
 BASED ON PLANS SUBMITTED AND WORK FROM A BUSINESS TO
 EDUCATION WILL REQUIRE WORK WHICH IS REQUIRED TO BE
 DONE BY CONTRACTORS LICENSED UNDER FLORIDA STATUTES
 489.
  
 2) NOTE: PLEASE KNOW ONCE THE VALUE FOR THE COMPLETE
 SCOPE OF CONSTRUCTION, DESIGN, MATERIALS AND EQUIPMENT
 HAS BEEN DETERMINED, THE APPLIED VALUE IS REQUIRED TO
 MEET FBC 108.3.
  
 3) NOTE: PLEASE SEE FBC 2004 W/2006 REVISIONS
 SPECIFICALLY THE EXISTING BUILDING CODE CHAPTER 8 FOR
 CHANGES IN OCCUPANCY. THE OCCUPANCY CLASSIFICATION OR
 GROUP IN CHANGING TO A HIGHER HAZARD AND WILL REQUIRE
 SOME SYSTEMS TO BE BROUGHT UP TO CODE IF THEY DO NOT
 MEET THE MINIMUM CODES AT THIS TIME.
 PLEASE SEE SECTION 808.2, 808.3, 808.4 AND 812,
 812.4.1. AS ELECTRICAL OUTLETS WHICH INCLUDE, LIGHTING
 FIXTURES, RECEPTACLES, ELECTRICAL PANELS ETC WHICH DO
 NOT MEET THE CURRENT NATIONAL ELECTRICAL CODE AND FCB
 CHAPTER 27 WILL BE REQUIRED TO BE BROUGHT UP TO CODE OR
 SHOWN AS EXISTING WHICH MEETS THE CURRENT MINIMUM
 CODES.
  
 ** PLEASE SEE NOTES FROM FIRE MARSHAL AND BUILDING
 REVIEWER WHICH WILL REQUIRE SOME OTHER SYSTEMS TO MEET
 THE CURRENT CODES FOR LIFE SAFETY ETC.
  
 4) NOTE: PLEASE SEE NFPA-101 CHAPTER 14 FOR NEW
 EDUCATION OCCUPANCIES.
 PLEASE SEE CHAPTER 7 FOR MINIMUM LIGHTING FOR EGRESS TO
 MEET CURRENT CODES.
 THE AMOUNT OF EMERGENCY LIGHTING FIXTURES SHOWN IN
 STAIR AREA ON THE NORTH SIDE OF SPACE DOES NOT MEET THE
 MINIMUM LEVELS.
 PLEASE SUBMIT PHOTO-METRICS FOR NORMAL AND EMERGENCY
 LEVELS INCLUDING STAIRS UNDER BOTH CONDITIONS. PLEASE
 SEE 7.8.1.3 AND 7.9.2.2.
 FAC 61G15-33.004
 ** PLEASE SEE 700.12F FOR CIRCUITING OF THESE
 FIXTURES.
  
 5) NOTE: PLEASE SEE SECTION 812 AS NOTED ABOVE IN NOTE
 #3 FOR THE FIRE ALARM SYSTEM/DEVICES WHICH IS REQUIRED
 TO MEET CURRENT CODES IF NOT ALREADY MEETING
 NFPA-72/NFPA-70 AND FBC CHAPTER 11.
 PLEASE INDICATE THE MINIMUM LEVELS FOR ALL ADA DEVICES
 PER FBC 11-4.28.1, .2 AND .3(4).
  
 6) NOTE: PLEASE COMPLETE PLANS INDICATING ALL LIGHTING.
 PLEASE SEE FBC CHAPTER 13, 13-415.1.ABC.1.1, AND .1.3.
 PLEASE SEE 13-415.2 FOR LIGHTING PERFORMANCE DENSITIES
 REQUIRED.
 FBC, EBC, SECTION 811.
  
 7) NOTE: PLEASE SUBMIT INFORMATION ON THE EXISTING
 ELECTRICAL SERVICE, PANELS AND EQUIPMENT FOR THE
 ELECTRICAL LOADS PROPOSED. EVEN AS LOADS MAY NOT BE
 INCREASING THE VERIFICATION OF THE EXISTING SERVICE
 EQUIPMENT NEEDS TO BE VERIFIED.
 FBC EBC, 808.3 AND FBC CHAPTER 27.
  
 8) NOTE: PLEASE SEE THE SITE PLAN ON THE SHEET AND AREA
 AS SPECIFIED INVOKES PLACES OF ASSEMBLY PER NEC 518.1.
  
 PLEASE SEE LS 101
  
 9) NOTE: PLEASE SEE NOTES FROM BUILDING AND FIRE
 MARSHAL WITH RESPECT TO THE STORAGE ADJACENT TO THIS
 OCCUPANCY. WHAT IS STORED IN THIS ROOM?
  
 10) NOTE: PLEASE KNOW THE APPLICATION IS ALSO BEING
 ROUTED TO OUR ADDRESSING REVIEWER SO THAT A CORRECT
 SUITE/UNIT NUMBER MAY BE AASIGNED.
 PLEASE BE SURE TO INCLUDE THIS ON THE APPLICATION AND
 TITLE BLOCKS ON PLANS ONCE THIS HAS BEEN DETERMINED.
 FBC 106.1.2, 106.1, 110.1.2 ETC
 FAC 61G1-16.004,
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-09-13 Cont ID  
Sent By mawillia Date 2007-09-13 Time 15:45 Rev Time 0.00
Received By mawillia Date 2007-09-13 Time 14:03 Sent To  
Notes
2007-09-13 15:45:28*****DENIED*****
 PLEASE BE ADVISED THAT EDUCATIONAL OCCUPANCIES SHALL
 INCLUDE ALL BUILDINGS USED FOR EDUCATIONAL PURPOSES
 THROUGH THE TWELFTH GRADE BY SIX OR MORE PERSONS FOR 4
 OR MORE HOURS PER DAY OR MORE THAN 12 HOUS PER WEEK.
 NFPA 101 -2003 EDITION - CHAPTER 14 (NEW EDUCATIONAL
 OCCUPANCIES) SHALL BE REFERENCED.
  
 01. SPECIFY THE CONTENTS OF THE NEW OCCUPANCY AS BEING
 CLASSIFIED AS LOW, ORDINARY, OR HIGH HAZARD.
  
 02.PROVIDE AN APPROVED AISLE OR SEATING/CLASSROOM
 DIAGRAM TO SUBSTANTIATE THE OCCUPANCY MODIFICATION.
  
 03.NO HANDRAILS/GUARDRAILS SHOWN IN NORTH STAIRWAY.
  
 04.EXIT ACCESS CORRIDORS SHALL HAVE NOT LESS THAN 72"
 OF OF CLEAR WIDTH.
  
 05.AISLES SHALL NOT BE LESS THAN 30" WIDE.
  
 06.IT IS INDICATED THAT THE STORAGE ROOM IS NOT PART
 OF THE TENANT SPACE.IF THIS IS SO, PLEASE EXPLAIN HOW
 CAN CONTENTS POSSIBLY STORED BY OTHER TENANT(S) BE
 ASSURED AS TO NOT NEGATIVELY IMPACT LIFE SAFETY IN YOUR
 TENENT SPACE.
  
 07.PROVIDE A LAYOUT OF THE FIRE SPRINKLERS FOR THIS
 PROJECT SITE.IF THE ERECTION/INSTALLATION OF DIVIDING
 WALLS HAS CAUSE FOR THE FIRE SPRINKLERS TO BE
 RELOCATED, A SEPARATE PLAN AND PERMIT WILL BE
 REQUIRED.
  
 08.IT IS SHOWN OF ONE EXISTING FIRE ALARM HORN AND
 STROBE IN THE OPEN AREA;HOWEVER, IN THE EVENT OF THE
 ERECTION/INSTALLATION OF DIVIDING WALLS TO CREATE
 CLASSROOMS, ADDITIONAL FIRE ALARMS SHALL BE REQUIRED.
 SEPARATE PLAN AND PERMIT ARE NEEDED.
  
 09.SPECIFY THE INTERIOR FINISH MATERIALS FOR THE
 WALLS AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR
 CLASS C.SPECIFY INTERIOR FLOOR FINISH IN TERMS OF
 CLASS I OR CLASS II.
  
 10.INDICATE WHAT THE UNIDENTIFIED ROOMS AND/OR SPACES
 ARE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  
  
  
  
  
  
 4.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 14:13 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 14:13 Sent To  
Notes
2007-08-31 10:53:36TO "BOB"#13
2007-08-23 14:13:38WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2007-08-23 Cont ID  
Sent By kconrad Date 2007-08-23 Time 09:23 Rev Time 0.00
Received By kconrad Date 2007-08-23 Time 09:23 Sent To I
Notes
2007-08-23 09:25:43CHANGE OF OCCUPANCY: REQUIRE PLAN REVIEW. NO
 ALTERATIONS TO THE EXISTING BUILDING INTERIOR.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-09-06 Cont ID  
Sent By tgordon Date 2007-09-06 Time 13:49 Rev Time 0.20
Received By tgordon Date 2007-09-06 Time 13:48 Sent To  
Notes
2007-09-06 13:55:40PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA
 ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS).
  
 *** DENIED ***
 1) PLEASE SUBMIT OUT-SIDE AIR CALCULATIONS AND STATE
 HOW OUT-SIDE AIR IS ENTERING THE SPACE, SEE MECH. 401.2
 AND 403.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-09-13 Cont ID  
Sent By mperson Date 2007-09-13 Time 13:06 Rev Time 0.00
Received By mperson Date 2007-09-13 Time 13:06 Sent To  
Notes
2007-09-13 13:18:44DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING WITH 2006 REVISIONS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
 ** FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004 CHAPTER 11 PLEASE CLEARLY INDICATE
 THAT THE PROVIDED DRINKING FOUNTAIN IS ACCESSIBLE PER
 SECTIONS 11-4.15.2 THRU 11-4.15.5 AND ALSO SECTION
 11.4.1.3(10)(A) WHERE ONLY ONE DRINKING FOUNTAIN IS
 PROVIDED ON A FLOOR, THERE SHALL BE A DRINKING FOUNTAIN
 WHICH IS ACCESSIBLE TO INDIVIDUALS WHO USE WHEELCHAIRS
 IN ACCORDANCE WITH SECTION 11-4.15 AND ONE ACCESSIBLE
 TO THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. (THIS
 CAN BE ACCOMODATED BY USE OF A HI/LO FOUNTAIN OR BY
 SUCH OTHER MEANS AS WOULD ACHIEVE THE REQUIRED
 ACCESSIBILITY FOR EACH GROUP ON EACH FLOOR.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2007-09-13 Cont ID  
Sent By mflis Date 2007-09-13 Time 16:52 Rev Time 0.00
Received By mflis Date 2007-09-13 Time 16:52 Sent To  
Notes
2007-09-13 16:52:35ZONING REVIEW: PASSED
  
 * CHANGE OF OCCUPANCY - EDUCATIONAL USES PERMITTED
 SECOND FLOOR ONLY
  
 MATT FLIS - 822-1445