| Plan Review Stops For Permit 07080451 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-10-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-03 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-03 |
Time |
05:59 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-31 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-31 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2007-08-31 10:03:17 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2)2004 FBC EXISTING | | | 301.5A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 3)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR RECORD KEEPING | | | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT | | | IS DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, | | | TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED | | | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | . ------------------------------------- | | | ) NUMBER OF UNITS | | | ) NUMBER OF FLOORS | | | ) NUMBER OF ROOMS | | | ) NUMBER OF BEDROOMS | | | ) SQ. FT. LIV SPACE/ FL | | | ) SQ. FT. FOOTPRINT | | | | | | 4))PROVIDE A DETAIL DRAWING OF EACH TYPE OF WALL | | | CORRESPONDING WITH THE WALL LEGEND. THE DRAWINGS SHALL | | | INDICATE ALL MATERIALS FOR THE CONSTRUCTION OF EACH | | | WALL. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-05-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-13 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-13 |
Time |
11:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-28 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-28 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2007-09-28 18:37:11 | ** PROVISO/REVISION NEEDED ** | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEWS ARE | | | STILL IN NEED OF ADDRESSING. | | | THE *PROVISO* WILL REQUIRE THESE ITEMS TO BE REVISED ON | | | PLANS ALONG WITH ANY OTHER REVISIONS DONE ON THE | | | PROJECT. | | | ** IF PLANS COME BACK WITH ANY OTHER COMMENTS, PLEASE | | | MAKE CORRECTIONS AT THIS TIME. THIS WILL HELP TO AVOID | | | ANY REVISION FEES AT A LATER DATE. | | | | | | 1) NOTE: PLEASE SEE COMMENTS FROM PREVIOUS REVIEW WHICH | | | REQUESTED THE ARC FAULT PROTECTED CIRCUITS TO BE LISTED | | | ON PANEL SCHEDULE FOR ROOMS AND AREAS IN WHICH THEY | | | FEED. | | | PLANS ARE REQUIRED TO SHOW DETAILED CODE COMPLIANCE. | | | QUOTING THE CONTRACTOR IS RESPONSIBLE TO PROVIDE AFCI | | | BREAKERS IS NOT SHOWING CODE COMPLIANCE AS REQUIRED PER | | | FLORIDA STATUTES 553.73 | | | NEC 210.12 AND FBC 106.3.5.1.2, 106.1.2, 110.1.2 | | | | | | 2) NOTE: PLEASE SEE AS NOTED ON PREVIOUS REVIEW; PLEASE | | | SEE THE AMPERAGE LOAD SHOWN ON THE PANEL SCHEDULE CAN | | | NOT POSSIBLY BE THE 2KVA AS LISTED ON LOAD | | | CALCULATIONS. | | | PLEASE RE-CALCULATE AS 2KVA DIVIDED BY THE VOLTAGE DOES | | | NOT EQUATE TO THE AMPERAGE AS LISTED ON PANEL SCHEDULE. | | | | | | | | | 3) NOTE: PLEASE SEE CIRCUIT NUMBER 21 WHICH IS PART OF | | | 210.52B1, HOWEVER BASED ON THE AMPERAGE SHOWN ON PANEL | | | SCHEDULE THIS DOES NOT MEET THE MINIMUM LOAD AS | | | REQUIRED PER 210.11C1 AND 220.53 | | | | | | 4) NOTE: PLEASE SEE PANEL SCHEDULE CIRCUIT #14 WHICH | | | STILL INDICATES SMOKE DETECTORS WHEN PLANS SHOW SMOKE | | | ALARMS. THIS COMMENT IS MINOR AND WAS REDLINED ON | | | PLANS. | | | THIS CAN BE REVISED WHEN REVISING PLANS FOR OTHER ITEMS | | | AS THIS SEEMS TO BE A MISPRINT. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-27 |
Time |
20:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-27 |
Time |
20:14 |
Sent To |
|
|
| Notes |
| 2007-08-27 20:14:47 | 2007-08-27 20:14:47 | | | | | | ** DENIED ** | | | | | | 1) NOTE: PLEASE SEE THE SMOKE DEVICES AS SHOWN ARE | | | BEING INDICATED AS SD, WHERE THE PLANS ALSO CALL FOR | | | THESE AS 120V UNITS. IF THESE ARE DEVICES WHICH DETECT | | | AND SOUND AN ALARM, THEY ARE IN FACT SMOKE ALARMS (SA) | | | AND NOT SMOKE DETECTORS. PLEASE SEE NFPA-72 DEFINITIONS | | | AS THE SD ONLY DETECT AND DO NOT PROVIDE AN AUDIBLE | | | ALARM. | | | PLEASE SEE NFPA-72 11.8.3 WHICH REQUIRES ALL SMOKE | | | DETECTION DEVICES TO BE A MINIMUM OF 20FT AWAY FROM | | | COOKING APPLIANCES. THERE IS AN EXCEPTION TO THIS AS | | | LONG AS ONE OF TWO SPECIFIC TYPES OF UNITS IS | | | INSTALLED. PLEASE SPECIFY | | | PLEASE ADJUST. | | | | | | 2) NOTE: PLEASE SEE THE REQUIRED DEDICATED BATH CIRCUIT | | | FOR THE GFI IS BEING SHOWN ON THE SAME CIRCUIT AS THE | | | SMOKE DETECTION DEVICES WHICH ARE NOT PERMITTED. PLEASE | | | SEE 210.52D,210.11C3. | | | (MUST BE 20AMP AND #12). | | | | | | 3) NOTE: PLEASE SEE THE MISSING LOAD TO BE FIGURED IN | | | THE LOAD CALCULATIONS FOR THE DINING ROOM RECEPTACLES | | | PER 210.52B1, 210.11C1, AND 220.53. | | | (1500VA MIN) | | | | | | 4) NOTE: PLEASE SEE THERE ARE SEVERAL ITEMS ON THE LOAD | | | CALCULATIONS WHICH DO NOT MATCH WITH THE AMPERAGE LOADS | | | BEING SHOWN ON THE PANEL SCHEDULE. | | | FOR EXAMPLE: | | | PLEASE SEE THE MICROWAVE/HOOD ON SCHEDULE SHOWS | | | 13.5AMPS. THIS AT 120V IS MUCH HIGHER THAN THE 900VA | | | SHOWN ON THE LOAD CALCULATIONS. | | | THIS IS THE SAME FOR OTHER LOADS SUCH AS WINE COOLER | | | JACUZZI ETC. | | | PLEASE SEE THE LOAD FOR THE A/C CAN NOT POSSIBLY BE THE | | | 2KVA AS SHOWN ON LOAD CALCULATIONS WITH AN AMPERAGE | | | LOAD OF 18.8AMPS. | | | PLEASE SEE SOME LOADS ON THE LOAD CALCULATIONS ARE TO | | | COORDINATE WITH THE LOADS ON PANELS. | | | NEC 220, 408.4, 240.4, 310.16 TO DETERMINE CIRCUITS. | | | FBC 106.3.5.4 | | | 106.1.2, 106.1.1 | | | | | | 5) NOTE: PLEASE LIST THE REQUIRED ARC FAULT PROTECTED | | | CIRCUITS PER 210.12. 408.4 | | | THIS IS REQUIRED FOR ALL OUTLETS, INCLUSIVE OF SMOKE | | | DEVICES (120V), RECEPTACLES, LIGHTS, FANS ETC. | | | | | | 6) NOTE: PLEASE SEE MISSING GFI RECEPTACLE ALONG | | | KITCHEN COUNTER SPACE WHICH IS REQUIRED PER 210.52C1, | | | 210.8A6. | | | THE PLANS STATE A SCALE OF 3/8 INCH PER FT, AND BASED | | | ON THE LENGTH OF COUNTER SPACE ALONG WALL NEAR LIVING | | | ROOM, AN ADDITIONAL GFI IS NEEDED | | | | | | 7) NOTE: PLEASE SEE ANY RECEPTACLES WITHIN 6FT OF WET | | | BAR SINKS ARE REQUIRED TO BE GFIOR GFI PROTECTED PER | | | 210.8A7 (DINING ROOM) | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-01 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-01 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2007-10-01 11:55:05 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A-1 AND E-1 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-30 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-30 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2007-08-30 12:41:46 | *****PROVISO***** | | | | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | THE OTHER REVIEWERS HAVE BEEN SATISFIED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-27 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-27 |
Time |
14:55 |
Sent To |
M |
|
| Notes |
| 2008-05-27 14:58:07 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-08 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-08 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2008-05-08 16:48:35 | TO "BOB"#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-18 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-18 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2007-09-18 15:25:20 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-10 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-15 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2007-08-27 13:55:22 | TO "BOB"#17 | | 2007-08-15 13:36:26 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-28 |
Time |
08:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-28 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2008-05-28 08:44:06 | REVISION TO MECH. PLAN PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-05-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-09 |
Time |
14:12 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-09 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2008-05-09 14:13:11 | REVISION TO MECH. PLAN M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-30 |
Time |
14:03 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-30 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-05-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-05-12 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-05-12 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-10 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-10 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2007-09-10 10:09:10 | PLUMBING FIXTURE CHANGE OUT. WATER TEST REQUIRED FOR | | | SHOWER AND TUB. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-27 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-27 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2007-08-27 15:19:56 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|