Plan Review Details - Permit 07080417
Plan Review Stops For Permit 07080417
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-10-10 Cont ID  
Sent By jgomez Date 2008-10-10 Time 15:48 Rev Time 0.00
Received By jgomez Date 2008-10-10 Time 14:52 Sent To  
Notes
2008-10-10 15:48:39STORM SHUTTERS AND DOOR PRODUCT APPROVALS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-04-16 Cont ID  
Sent By jgomez Date 2008-04-16 Time 17:38 Rev Time 0.00
Received By jgomez Date 2008-04-16 Time 17:38 Sent To PC
Notes
2008-04-16 18:16:57RESIDENTIAL (R3) ADDITION, BUILDING REVIEW APPROVED
 WITH PROVISO:
  
 1- PROVIDE REVISEDINFORMATION FOR STORM SHUTTERS. SEE
 COMMENTS ON SUBMITTED PACKAGE.REVISE AS REQUIRED AND
 RESUBMIT COMPLETE PACKAGE PRIOR TO INSTALLATION TO
 AVOID DELAYS OR CONFLICTS.
  
 2- PROVIDE PRODUCT APPROVAL FOR "SINGLE" DOOR AS SHOWN
 ON PLANS PRIOR TO INSTALLATION TO AVOID DELAYS OR
 CONFLICTS.PRODUCT APPROVAL SUBMITTED IS FOR DOUBLE
 DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-03-27 Cont ID  
Sent By jgomez Date 2008-03-26 Time 16:58 Rev Time 0.00
Received By jgomez Date 2008-03-26 Time 07:44 Sent To PC
Notes
2008-03-27 11:28:14RESIDENTIAL ADDITION, BUILDING REVIEW 4TH CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
 1- ENERGY CALCULATIONS NEED TO BE SIGNED AND DATED BY
 THE OWNER/AGENT.
  
 2- REVISIONS ON SURVEY NEED TO BE DONE BY THE SURVEYOR.
 (REPEAT COMMENT).SURVEYOR TO REVISE FLOOD ZONE "C" TO
 "B" AND PROVIDE REVISED SURVEY WITH ORIGINAL SEAL AND
 SIGNATURE AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE
 AND SEC. 61G17-7.0025 FLORIDA ADMINISTRATIVE CODE.
 NOTE: MAKE SURE ORIGINAL SIGNATURE IS PROVIDED. RUBBER
 STAMP OR PHOTOCOPY OF SIGNATURE IS NOT ALLOWED.
  
 3- STORM SHUTTERS:
 A) THERE WAS NOT PRODUCT APPROVAL SUBMITTED.
  
 B) INSTALLATION SCHEDULE SUBMITTED NEED TO BE
 CORRECTED:
 I) THERE ARE TWO DIFFERENT TYPES OF ANCHORS SPECIFIED:
 TAPCON AND TITEN. SEESHUTTER PRODUCT APPROVAL AND
 SPECIFIED AND MARK SPECIFIC ANCHOR TO BE USED.
  
 II) OPENINGS 6 AND 7 ARE THE SAME SIZE WINDOWS. HOW
 COME OPENING SIZES ARE DIFFERENT. REVISE AS REQUIRED.
  
 III) SHUTTER MOUNTING CONDITIONS ON COLUMN 4 IS ASKING
 FOR MOUNTING CONDITION. EG: WALL MOUNTED, BUILT OUT,
 ETC. NOT FOR ANCHOR TYPE.SEE SHUTTERS PRODUCT
 APPROVAL AND WRITE DOWN ON THIS COLUMN AND MARK
 SHUTTERS DRAWINGS WITH THAT MOUNTING CONDITION.
  
 IV) CLARIFY HOW ARE YOU GETTING THE 4" GLASS SEPARATION
 SHOWN ON COLUMN 5.
  
 V) SHUTTER SPANS SPECIFIED ON COLUMN 6 ARE WRONG.THEY
 ARE SHOWN AS THE SAME HEIGHT AS THE OPENING.THIS
 DOESN'T ALLOW THE 3" EDGE DISTANCE SPECIFIED ON COLUMN
 8. REVISE AS REQUIRED.
  
 VI) MINIMUM EDGE DISTANCE SPECIFIED ON COLUMN #8 IS 3"
 EDGE DISTANCE.SEE STORM SHUTTERS DRAWINGS FOR
 REQUIRED ANCHOR SPACING REDUCTION WHEN EDGE DISTANCE IS
 LESS THAN 3.5" AND REVISE ANCHOR SPACING ACCORDINGLY.
  
 VII) CLARIFY HOW ARE THE ANCHORS GOING TO BE SPACED AT
 6.5" . SEESHUTTERS DRAWINGS FORWIDTH OF STORM
 PANELS AND LOCATION OF ANCHORS. AND REVISE AS
 REQUIRED.
  
 VIII) CLEARLY MARK ON STORM SHUTTER DRAWINGS SPECIFIC
 MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILT OUT, ETC)
 AND SPECIFIC ANCHOR TO BE USED ACCORDING TO THE DESIGN
 PRESSURES, CONNECTION TYPE, PANEL SPAN, EDGE DISTANCE
 AND STRUCTURE TO BE ATTACHED TO (MASONRY OR CONCRETE
 BLOCK).
  
 4- NONE OF THE PRODUCT APPROVALS REQUIRED BY DCA RULE
 9B-72 WHERE SUBMITTED THIS TIME. NEED TO PROVIDE
 PRODUCT APPROVALS FOR: DOORS, WINDOWS, ROOF SHINGLES,
 SHUTTERS, SIMPSON STRUCTURAL CONNECTORS.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 6- SHEET 1:REVISE CONSTRUCTION STANDARD. THERE IS NOT
 "5 STD CBS". SEE SEC. 602.5 AND TABLE 601 OF FLORIDA
 BUILDING CODE 2004 AND SPECIFY IF CONSTRUCTION TYPE IS
 TYPE VA OR B.
  
 7- DRAWINGS SUBMITTED NOW DON'T HAVE THE PALM BEACH
 COUNTY IMPACT FEES STAMP. PLEASE PROVIDE OLD PAGEWITH
 THE IMPACT FEES STAMP OR GET THE REVISED SHEETS
 RE-STAMPED.
  
 8- SOIL TEST REPORT:
 A) SOIL TEST REPORT CALLS FOR 2000 PSF SOIL BEARING
 CAPACITY.ENGINEER OF RECORD SPECIFIES ON STRUCTURAL
 NOTE #1 THAT 200 PSF SOIL BEARING CAPACITY IS REQUIRED.
 ENGINEER OF RECORD TO COORDINATE WITH GEOTECHNICAL
 ENGINEER FOR SOIL BEARING CAPACITY REQUIRED AND ACTUAL
 SOIL BEARING CAPACITY TO BE PROVIDED. REVISE AS
 REQUIRED.
  
 B) ONLY ONE REPORT WAS SUBMITTED.NEED TO PROVIDE
 2 REPORTSWITH ORIGINAL SEAL AND SIGNATURE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-11-28 Cont ID  
Sent By jgomez Date 2007-11-28 Time 14:48 Rev Time 0.00
Received By jgomez Date 2007-11-28 Time 07:31 Sent To PC
Notes
2007-11-28 15:30:28RESIDENTIAL ADDITION BUILDING REVIEW THIRD CHECKLIST.
 REVIEW DONE UNDER EXISTING BUILDING CODE 2004, FLORIDA
 RESIDENTIAL CODE 2004 AND FBC 2004 WITH 2007
 REVISIONS.
  
 1- PROVIDE COMPLETE SECTION/DETAIL AND SPECIFICATIONS
 SHOWING REINFORCEMENT AND SHORING SPECIFICATIONS FOR
 DEMOLITION OF EXTERIOR BEARING WALL AT BEDROOM#3
 AREA.(NO REAR ROOM)(REPEAT COMMENT.THREE TIMES).
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. CONCERN WITH
 STRUCTURAL STABILITY OF BUILDING WHEN EXISTING BEARING
 WALL IS REMOVED AND ADDITIONAL ROOF LOAD WEIGHT IS
 ADDED WHEN RECEIVINGNEW ROOF.SEC. R301.1 OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 2- ENGINEER TO PAY A FEE OF FOUR TIMES THE PLAN REVIEW
 FEES ($1308.30)AS REQUIRED BY FLORIDA STATUTE SEC.
 553.80(2)(B). SEE ATTACHED FLORIDA STATUTE COPY. NOTE:
 ONE COPY OF PLANS WILL BE RETAINED IN THIS OFFICE.
 (NOTE: TALKED TO MR. ERVIN L. KEEL. SE SAID DRAWINGS
 WHERE SUBMITTED WITHOUT ENGINEER'S CONSENT)
  
 3- ENERGY CALCULATIONS: SEE PLUMBING COMMENTS REGARDING
 WATER HEATER AND REVISE AS REQUIRED. (REPEAT COMMENT).
  
 4- NOTICE OF COMMENCEMENT EXPIRES AFTER 90 DAYS OF
 BEING RECORDED IF WORK IS NOT STARTED.IT WAS RECORDED
 ON 08/14/2007, THEREFORE IS EXPIRED. NEED TO PROVIDE
 RE-RECORDED ONE.
  
 5- SURVEY PROVIDED SHOWING 5.0' SIDE SETBACK IS NOT
 ACCURATE.THERE IS ANOTHER SURVEY SHOWING 4.4'
 SETBACK.THIS LOOKS LIKE EXISTING BUILDING IS AT 4.4'
 SETBACK.FLOOR PLANS SHOW NEW ADDITION BEING ALIGNED
 WITH EXISTING BUILDING. THEREFORE THE 5.0' SETBACK IS
 INCORRECT. NEED TO PROVIDE CORRECT INFORMATION.
  
 6- SURVEY SUBMITTED STATES FLOOD ZONE "C". THIS
 PROPERTY IS LOCATED ON FLOOD ZONE "B". REVISE AS
 REQUIRED.
 NOTE: ONLY SURVEYOR IS ALLOWED TO DO REVISIONS ON HIS
 OWN WORK.
  
 7- PREVIOUS SUBMITTAL INCLUDED SINGLE HUNG WINDOWS WITH
 IMPACT GLASS.PRODUCT APPROVAL SUBMITTED NOW IS FOR
 NON-IMPACT GLASS. THEREFORE SHUTTERS ARE REQUIRED.
 PRODUCT APPROVAL FOR STORM SHUTTERS SUBMITTED NEED MORE
 INFORMATION. NEED TO PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE (OR PROVIDE COMPLETE
 INFORMATION ON ANOTHER FORMAT). ALSO, CLEARLY MARK ON
 SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS (EG:
 WALL MOUNTED, BUILT OUT, ETC) AND SPECIFIC ANCHOR TYPE
 AND SPACING TO BE USED TO VERIFY COMPLIANCE WITH
 PROPOSED INSTALLATION. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 8- SHEET 1:
 A)DESIGN STANDARDS: WHAT'SCONSTRUCTION TYPE "E".
 WHERE IS THIS INFORMATION TAKEN FROM?. REVISE AS
 REQUIRED.
  
 B) ALSO, UPDATE THE FBC 2004 REVISIONS. CORRECT
 REVISIONSTO BE REFERENCED IS 2007, NOT 2006. REVISE
 AS REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-19 Cont ID  
Sent By jgomez Date 2007-10-19 Time 12:59 Rev Time 0.00
Received By jgomez Date 2007-10-18 Time 17:44 Sent To PC
Notes
2007-10-19 13:31:50RESIDENTIALADDITION BUILDING REVIEW SECOND
 CHECKLIST.
 REVIEW DONE UNDER EXISTING BUILDING CODE 2004,
 RESIDENTIAL CODE 2004 AND FBC 2004 WITH 2007
 REVISIONS.
  
 1- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 OWES $320.93 FOR UPDATED VALUATION AND RADON FEES.
 (REPEAT COMMENT).
 RESPONSE LETTER SAID FEES WERE PAID AND PAID RECEIPT IS
 ATTACHED.THIS WAS NOT DONE.
  
 2- PROVIDE COMPLETE SECTION/DETAIL AND SPECIFICATIONS
 SHOWING REINFORCEMENT AND SHORING SPECIFICATIONS FOR
 DEMOLITION OF EXTERIOR BEARING WALL AT BEDROOM #3 AREA.
 (REPEAT COMMENT). SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
 PLANS DON'T SHOW ANY DETAILS OR SPECIFICATIONS SHOWING
 HOW TO SHORE STRUCTURE TO AVOID COLLAPSE OF ROOF ABOVE
 WHEN WALL IS REMOVED.
  
 3- PLANS TO SPECIFY ALL LIVE AND DEAD LOADS, INCLUDING
 THE ATTIC LIVE LOADS. ENGINEER TO REVIEWSEC. R301 AND
 TABLE R301.5 OF RESIDENTIAL CODE 2004 AND PROVIDE
 REQUIRED INFORMATION. (REPEAT COMMENT). INFORMATION
 SUBMITTED IS INCOMPLETE AND INCORRECT. IT CAN'T BE ONLY
 10PSF ATTIC LIVE LOAD AND DEAD LOAD OF 30PSF. REVISE
 DESIGN INFORMATION AS REQUIRED.
  
 4- ENGINEER TO REVIEW ATTACHED COPY OF FLORIDA STATUTE
 553.80(2)(B) REGARDING PLAN REVIEW FEES TO BE PAID BY
 ENGINEER WHEN DOCUMENTS ARE REJECTED SEVERAL TIMES.
 ***NOTE: ONE COPY OF PLANS WILL BE RETAINED IN THIS
 OFFICE TO BE SEND TOFLORIDA BOARD OF ENGINEERS FOR
 REVIEW.
  
 5- ENERGY CALCULATIONS:
 A) SEE PLUMBING COMMENTS REGARDING WATER HEATER.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 6- SOIL TEST REPORT CALLS FOR 2000 PSF SOIL BEARING
 CAPACITY, WHILE STRUCTURAL NOTE #1 ONSHEET 2 REQUIRES
 2500 PSF SOIL BEARING CAPACITY.ACCORDING TO THIS THE
 SOIL DOESN'T MEET THE ENGINEER'S DESIGN CRITERIA.
 REVISE AS REQUIRED.
  
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) SINGLE HUNG WINDOWS. NEED TO PROVIDEREPORT WITH
 LEGIBLE DRAWINGS AS REQUIRED BY SEC. 106.1.3 CITY
 AMENDMENTS TO FBC 2004. (REPEAT COMMENT).
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 ALL PLANS. (REPEAT COMMENT).
 ONLY PRODUCT APPROVAL FOR ONE CONNECTOR WAS SUBMITTED.
  
 ***NOTE: CLARIFY WHY SUBMITTING PRODUCT APPROVAL FOR
 STORM SHUTTERS IF WINDOWS PRODUCT APPROVALSUBMITTED
 HAVE MISSILE IMPACT GLASS.
  
 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 (REPEAT COMMENT).
 ENGINEER CAN'T SIGN AND SEAL THESE PRODUCT APPROVALS
 BECAUSE THEY ARE NOT HIS DESIGN.
 PLEASE MAKE SURE NAME OF ENGINEER APPROVING PRODUCT
 APPROVALS IS SHOWN ON THE REVIEW PRODUCT APPROVAL.
  
 9- REVISE ROOF SHEATHING NAILING SPACING. SEE SEC.
 R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE.REPEAT
 COMMENT.NEED TO IDENTIFY ROOF ZONE 3 AND NAIL SPACING
 AS REQUIRED BY THE CITE SECTION ON THIS COMMENT.
  
 10- PLEASE DON'T STAPLE PRODUCT APPROVALS TO THE
 DRAWINGS. THIS WILL EXPEDITE THE REVIEW PROCESS.
  
 11- TYPICAL WALL SECTION. REVISE CEILING INSULATION
 VALUE TO MATCH THE ENERGY CALCULATIONS.
  
 ***NOTE:RE-SUBMITTAL FEES WILL APPLY FOR NEXT
 SUBMITTAL.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-06 Cont ID  
Sent By jgomez Date 2007-09-06 Time 12:38 Rev Time 0.00
Received By jgomez Date 2007-09-06 Time 12:38 Sent To PC
Notes
2007-09-06 14:01:25RESIDENTIAL ADDITION BUILDING REVIEW FIRST CHECKLIST.
 REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND
 FBC 2004 WITH 2007 REVISIONS.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD (561)233-5115)TO VERIFY IF
 IMPACT FEES ARE DUE OR NOT. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.
  
 2- VALUEDECLARED IN THE PERMIT APPLICATION IS TOO
 LOW.VALUE WAS UPDATED TO $59,025 AS REQUIRED BY SEC.
 108.3 OF CITY AMENDMENTS TO FBC 2004. THEREFORE, OWES
 $320.93 FOR UPDATED VALUATION AND RADON FEES.
  
 3- FLOOR PLAN SHOWS ACCESS TOBEDROOM #5 THRU BEDROOM
 #4. GOING FROM ONE ROOM BEDROOM THRU ANOTHER BEDROOM IS
 NOT ALLOWED BY SEC. 1013.2 FBC 2004. REVISE AS
 REQUIRED.
  
 4- ENGINEER TO PROVIDE HIS FIRM CERTIFICATE OF
 AUTHORIZATION NUMBER IN THE TITLE BLOCK AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTE AND SEC. 61G15--23.002 OF
 FLORIDA ADMINISTRATIVE CODE.
  
 5- PLANS TO SPECIFY CONSTRUCTION TYPE AS REQUIRED BY
 SEC. 602.1 FBC 2004.
  
 6- PROVIDE COMPLETE SECTION/DETAIL AND SPECIFICATIONS
 SHOWING REINFORCEMENT AND SHORING SPECIFICATIONS FOR
 DEMOLITION OF EXTERIOR BEARING WALL AT BEDROOM #3 AREA.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 7- SPECIFY ATTIC ACCESS AS REQUIRED BY SEC. R807 OF
 2004 FLORIDA RESIDENTIAL CODE.
  
 8- PLANS TO SPECIFY ALLLIVE AND DEAD LOADS, INCLUDING
 THE LIVE LOADINTHE ATTIC AS REQUIRED BYTABLE
 R301.5 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 9- DRAWINGS ARE NOT LEGIBLE.LETTERING ON SOME DETAILS
 IS NOT LEGIBLE. MAKE SURE ALL DETAILS AND NOTES ARE
 CLEAR AND LEGIBLE AS REQUIRED BY SEC. 106.1.3 OF CITY
 AMENDMENTS TO FBC 2004..
  
 10- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-600.1.C.1 FBC 2004.
 NOTE: MAKE SURE CORRECT 2006 REVISED FORM IS USED. AND
 MAKE SURE FORM IS FILLED COMPLETELY AND SIGNED AND
 DATED BY THE PREPARER AND OWNER.
  
 11- PROVIDE 2 COPIES OF SOIL TEST REPORT AS REQUIRED BY
 SEC. R401.4 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 12- PRECAST CONCRETE LINTEL SCHEDULE TO BE KEYED ON
 PLANS TO VERIFY SIZES. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 13- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) EXTERIOR DOORS. PROVIDE COMPLETE REPORT SHOWING
 ALL TECHNICAL INFORMATION FOR MODEL TO BE INSTALLED.
 ONLY FLORIDA FL4904 PRODUCT COVER PAGES WERE
 SUBMITTED.
  
 B) SINGLE HUNG WINDOWS. PROVIDE LEGIBLE DRAWINGS.
 NOA 03-0910.04 SUBMITTED IS NOT LEGIBLE. SEC. 106.1.3
 CITY AMENDMENTS TO FBC 2004.
  
 C) STORM PANELS. PROVIDE LEGIBLE DRAWINGS. SEC.
 106.1.3 CITY AMENDMENTS TO FBC 2004.
 ***NOTE: PROVIDECOMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED SAMPLE. AND, CLEARLY INDICATE ON SHUTTERS
 DRAWINGS SPECIFIC ANCHOR TYPE AND SPACING TO BE USED.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 D) ALL SIMPSON CONNECTORS SPECIFIED ON PLANS AND
 DETAILS.
 ***NOTE: PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE WERE CONNECTOR IS SHOWN.
  
 E) PRECAST LINTELS SPECIFIED ON PLANS.
  
 14- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 15- SHEET 2:
 A) SPECIFY CONNECTOR AT BOTH ENDS OF GIRDER TRUSS
 SHOWN BY BEDROOM #3ROOF AREA. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 B) REVISE ATTACHMENT SCHEDULE. CLARIFY WHYSOME
 CONNECTORS THE ENGINEER IS USING THE 133 VALUES AND
 SOME CONNECTORS THE 160 VALUE.. EG SEE MTS16
 CONNECTOR.
  
 C) REVISE ROOF SHEATHING NAILING SPACING . SEE SEC.
 803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE FOR MIN.
 REQUIRED SPACING INCLUDING NAILING AT CORNER ZONE #3
 AREAS.
  
 D) REVISE DOOR AND WINDOW ATTACHMENT NOTES. SEE
 CORRESPONDING PRODUCT APPROVALS FOR REQUIRED FASTENER
 TYPE SIZE AND SPACING. ALSO, VERIFY SUBSTRATE TO BE
 INSTALLED TO.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2008-04-10 Cont ID  
Sent By btrobaug Date 2008-04-10 Time 08:10 Rev Time 0.00
Received By btrobaug Date 2008-04-10 Time 06:56 Sent To P
Notes
2008-04-10 08:10:18 
  
 PROVISO
  
 ADD SECOND AHU & A/C TO THE PANEL SCHEDULE AND
 RECALCULATE THE LOAD TO SHOW BOTH SYSTEMS PRIOR TO
 ROUGH INSPECTION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-03-21 Cont ID  
Sent By btrobaug Date 2008-03-21 Time 16:06 Rev Time 0.00
Received By btrobaug Date 2008-03-21 Time 15:27 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-11-19 Cont ID  
Sent By btrobaug Date 2007-11-19 Time 12:25 Rev Time 0.00
Received By btrobaug Date 2007-11-19 Time 11:59 Sent To P
Notes
2007-11-19 12:25:06 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
 THE FOLLOWING COMMENTS ARE REGARDING THE ELECTRICAL
 DRAWINGS ON SHEET 2 OF 2.
  
 THESE COMMENTS WERE NOT ADDRESSED ON THE PREVIOUS
 REVIEW, 8/27/07, OR ON THE 11/19/07 REVIEW.
  
 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN
 IS NEW OR EXISTING. IF NEW INCLUDE IN THE DESCRIPTION
 ON THE APPLICATION, PROVIDE AN AIC RATING, ANDLOCATE
 ALL SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE,
 DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A RISER
 DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND TYPE.* THE
 AIC RATING IS NOT ON THE PLAN.** SAME COMMENT
 11/19/07.
  
 2} PLEASE PROVIDE A PANEL SCHEDULE SO THAT
 BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT
 PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC
 AS AMENDED. THERE IS NO CONDENSER # 2 ON THE SCHEDULE
 PROVIDED AND APPLIANCES THAT ARE IN THE CALCULATION ARE
 MISSING. SEE 408.4 2005 NEC. *THERE ARE STILL
 APPLIANCES MISSING FROM THE SCHEDULE. SMALL APPLIANCE,
 WASHER AND THE TERMS "CONV. OUTLETS AND GEN LIGHTING"
 ARE NOT SPECIFIC ENOUGH TO MEET THE INTENT OF
 408.4.**SAME COMMENT 11/19/07.
  
 3} THERE IS 10000 VA OF HEAT IN THE LOAD CALCULATION,
 CORRECTLY CALCULATED AT 100% PER 220.83(B), BUT THE
 PANEL SCHEDILE INDICATES 2 AIR HANDLERS WITH AN OCP OF
 60 AMPS, WHICH WOULD IMPLY THAT THERE ARE 2 UNITS WITH
 10000 VA EACH. PLEASE CLARIFY. *IF THE AHU'S ARE 5KW
 EACH, THEN THE 60 AMP OCP IS IN VIOLATION OF 310.16 AND
 240.4.** SAME COMMENT REGARDING 5KW ON A 60 AMP
 BREAKER.
  
 PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH
 CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM
 SEPARATELY TO EXPEDITE THE REVIEW PROCESS.
 ANSWER REVIEW COMMENTS IN WRITING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-10-11 Cont ID  
Sent By btrobaug Date 2007-10-11 Time 13:12 Rev Time 0.00
Received By btrobaug Date 2007-10-11 Time 12:46 Sent To P
Notes
2007-10-11 13:05:05 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
 THE FOLLOWING COMMENTS ARE REGARDING THE ELECTRICAL
 DRAWINGS ON SHEET 2 OF 2.
  
 THESE COMMENTS WERE NOT ADDRESSED ON THE PREVIOUS
 REVIEW, 8/27/07.
  
 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN
 IS NEW OR EXISTING. IF NEW INCLUDE IN THE DESCRIPTION
 ON THE APPLICATION, PROVIDE AN AIC RATING, ANDLOCATE
 ALL SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE,
 DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A RISER
 DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND TYPE.* THE
 AIC RATING IS NOT ON THE PLAN.
  
 2} PLEASE PROVIDE A PANEL SCHEDULE SO THAT
 BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT
 PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC
 AS AMENDED. THERE IS NO CONDENSER # 2 ON THE SCHEDULE
 PROVIDED AND APPLIANCES THAT ARE IN THE CALCULATION ARE
 MISSING. SEE 408.4 2005 NEC. *THERE ARE STILL
 APPLIANCES MISSING FROM THE SCHEDULE. SMALL APPLIANCE,
 WASHER AND THE TERMS "CONV. OUTLETS AND GEN LIGHTING"
 ARE NOT SPECIFIC ENOUGH TO MEET THE INTENT OF 408.4.
  
 3} THERE IS 10000 VA OF HEAT IN THE LOAD CALCULATION,
 CORRECTLY CALCULATED AT 100% PER 220.83(B), BUT THE
 PANEL SCHEDILE INDICATES 2 AIR HANDLERS WITH AN OCP OF
 60 AMPS, WHICH WOULD IMPLY THAT THERE ARE 2 UNITS WITH
 10000 VA EACH. PLEASE CLARIFY. *IF THE AHU'S ARE 5KW
 EACH, THEN THE 60 AMP OCP IS IN VIOLATION OF 310.16 AND
 240.4.
  
 PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH
 CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM
 SEPARATELY TO EXPEDITE THE REVIEW PROCESS.
 ANSWER REVIEW COMMENTS IN WRITING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-27 Cont ID  
Sent By btrobaug Date 2007-08-27 Time 10:19 Rev Time 0.00
Received By btrobaug Date 2007-08-27 Time 06:55 Sent To P
Notes
2007-08-27 10:19:17 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
 THE FOLLOWING COMMENTS ARE REGARDING THE ELECTRICAL
 DRAWINGS ON SHEET 2 OF 2.
  
 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN
 IS NEW OR EXISTING. IF NEW INCLUDE IN THE DESCRIPTION
 ON THE APPLICATION, PROVIDE AN AIC RATING, ANDLOCATE
 ALL SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE,
 DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A RISER
 DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND TYPE.
  
 2} PLEASE PROVIDE A PANEL SCHEDULE SO THAT
 BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT
 PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC
 AS AMENDED. THERE IS NO CONDENSER # 2 ON THE SCHEDULE
 PROVIDED AND APPLIANCES THAT ARE IN THE CALCULATION ARE
 MISSING. SEE 408.4 2005 NEC.
  
 3} THERE IS 10000 VA OF HEAT IN THE LOAD CALCULATION,
 CORRECTLY CALCULATED AT 100% PER 220.83(B), BUT THE
 PANEL SCHEDILE INDICATES 2 AIR HANDLERS WITH AN OCP OF
 60 AMPS, WHICH WOULD IMPLY THAT THERE ARE 2 UNITS WITH
 10000 VA EACH. PLEASE CLARIFY.
  
 4} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3),THIS CIRCUIT IS NOT ON THE
 SCHEDULE.
  
 5} R313.1.1, RESIDENTIAL BUILDING CODE, SMOKE ALARMS
 SHALL BE LOCATED AS REQUIRED IN NEW DWELLINGS WHEN
 REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR. SEE
 ARTICLE FOR COMPLETE TEXT.ALSO SEE THE DEFINITION OF
 "SMOKE DETECTORS" 11.8.2.1 NFPA-72, CLARIFY IF USING
 DETECTORS OR ALARMS, TO AVOID CONFUSION IN THE FIELD.
 IF USING DETECTORS INDICATE THE LOCATIONS OF THE
 SOUNDING DEVICES.
  
 6} INDICATE A DISCONNECTING MEANS FOR THE WATER HEATER.
 SEE 422.16 NEC FOR CORD AND PLUG RESTRICTIONS, AND
 422.31(B) FOR HARDWIRE REQUIREMENTS. ALSO 110.26 AND
 440.14 FOR THE CONDENSING UNIT.
  
 PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH
 CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM
 SEPARATELY TO EXPEDITE THE REVIEW PROCESS.
 ANSWER REVIEW COMMENTS IN WRITING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-10-02 Cont ID  
Sent By adarroug Date 2008-10-02 Time 14:16 Rev Time 0.00
Received By adarroug Date 2008-10-02 Time 14:16 Sent To M
Notes
2008-10-02 14:17:13TO "M" BOX/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-04-08 Cont ID  
Sent By adarroug Date 2008-04-08 Time 15:17 Rev Time 0.00
Received By adarroug Date 2008-04-08 Time 15:17 Sent To Z
Notes
2008-04-08 15:18:13TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-03-20 Cont ID  
Sent By adarroug Date 2008-03-20 Time 13:59 Rev Time 0.00
Received By adarroug Date 2008-03-20 Time 13:59 Sent To Z
Notes
2008-03-20 14:00:17TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-11-13 Cont ID  
Sent By adarroug Date 2007-11-13 Time 08:48 Rev Time 0.00
Received By adarroug Date 2007-11-13 Time 08:48 Sent To Z
Notes
2007-11-13 08:49:41TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 10:45 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 10:45 Sent To Z
Notes
2007-10-05 10:46:25TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-06 Cont ID  
Sent By jgomez Date 2007-09-06 Time 14:01 Rev Time 0.00
Received By jgomez Date 2007-08-15 Time 10:55 Sent To  
Notes
2007-08-15 10:56:15TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-10-02 Cont ID  
Sent By tgordon Date 2008-10-02 Time 14:49 Rev Time 0.30
Received By tgordon Date 2008-10-02 Time 14:49 Sent To  
Notes
2008-10-02 14:50:26RE-STAMP MECH. PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2008-04-14 Cont ID  
Sent By tgordon Date 2008-04-14 Time 16:20 Rev Time 0.30
Received By tgordon Date 2008-04-14 Time 16:20 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2008-03-24 Cont ID  
Sent By tgordon Date 2008-03-24 Time 10:41 Rev Time 0.45
Received By tgordon Date 2008-03-24 Time 10:41 Sent To P
Notes
2008-03-24 10:44:02PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) AS REQUESTED IN LAST TWO REVIEWS 11-17-07 NOTE #1
 AND 10-17-07 NOTE #1. PLEASE SUBMIT THE 'LONG FORM'
 "COOLING LOAD CALCULATIONS", (NOT TO BE CONFUSED WITH
 THE ENERGY CALCULATIONS) PER 2004 FBC/R M1401.3 HEATING
 AND COOLING EQUIPMENT SHALL BE SIZED BASED ON BUILDING
 LOADS CALCULATED IN ACCORDANCE WITH ACCA "MANUAL J" OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES. THE ENGINEERS RESPONSE LETTER STATES A
 NEW LONG FORM ENERGY CALCULATIONS IS ATTACHED.
  
 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-103.3.
  
 3) PLEASE SHOW ON MECHANICAL PLAN HOW RETURN AIR WILL
 GET TO THE AIR HANDLER UNIT FROM ANY OF THE ROOMS WHEN
 ALL DOORS ARE CLOSED, SEE 2004 FBC/R M1602.4.
  
 4) PLEASE BE ADVISED A FOUR TIMES THE FEE WILL BE
 CHARGED TO THE PERMIT IF NOTE ONE HAS NOT BEEN
 CORRECTED, PER FS 553.80(2)(B). PLEASE CALL IF YOU NEED
 ANY ASSISTANCE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-11-27 Cont ID  
Sent By tgordon Date 2007-11-27 Time 11:35 Rev Time 0.45
Received By tgordon Date 2007-11-27 Time 11:35 Sent To B
Notes
2007-11-27 11:35:47PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) AS NOTED IN LAST REVIEW 11-17-07 NOTE #1.BUILDING
 ADDITION IS 759 SQUARE FEET UNDER AIR, COOLING LOAD
 CALCULATIONS SHOW ROOF AREA AT 2118 IS THAT SQUARE FEET
 OR BTU'S, PLEASE SUBMIT LONG FORM CALCULATIONS AS
 REQUIRED BY 2004 FBC/R M1401.3 HEATING AND COOLING
 EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS
 CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER
 APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES.
  
 2) AS NOTED IN LAST REVIEW 10-17-07 NOTE #3. MECHANICAL
 PLAN SUBMITTED HAVE TO MUCH FLOOR PLAN DETAIL ON THEM
 AND DUCT DESIGN IS FADED THEY ARE DIFFICULT TO READ.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, SEE F.B.C.
 106.1.1.
  
 3) AS NOTED IN LAST REVIEW 10-17-07 NOTE #4. WHEN
 RESUBMITTING MECHANICAL PLANS PLEASE HAVE THEM APPEAR
 SEMI-PROFESSIONAL AND HAVE ALL PERTINENT INFORMATION ON
 THEM (JOB ADDRESS, DESIGNER'S INFORMATION & SIGNATURE,
 EQUIPMENT SCHEDULE, ETC. (TWO COPIES)
  
 4) AS NOTED IN LAST REVIEW 10-17-07 NOTE #5. MECHANICAL
 PLAN SHOWS AN 18" RETURN DUCT GOING OFF THE PAGE,
 PLEASE SHOW WERE IT IS GOING.
  
 5) AS NOTED IN LAST REVIEW 10-17-07 NOTE #8. SHOW
 LOCATION OF THE CLOTHES DRYER VENT ON THE MECHANICAL
 PLAN, BE ADVISED THE CLOTHES DRYER VENT MAY NOT
 DISCHARGE NEAR THE A/C CONDENSER UNIT, SEE 2004 FBC/R
 401.5.2.
  
 6)SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING
 FOUR TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-10-17 Cont ID  
Sent By btrobaug Date 2007-11-19 Time 12:33 Rev Time 0.40
Received By tgordon Date 2007-10-17 Time 14:43 Sent To B
Notes
2007-10-17 14:57:41PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PLANS SHOW TOTAL AREA UNDER AIR AT 1,818 SQUARE
 FEET, COOLING LOAD CALCULATIONS SHOW ROOF AREA AT 2118
 IS THAT SQUARE FEET OR BTU'S, PLEASE SUBMIT LONG FORM
 CALCULATIONS AS REQUIRED BY 2004 FBC/R M1401.3 HEATING
 AND COOLING EQUIPMENT SHALL BE SIZED BASED ON BUILDING
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES.
  
 2)ENERGY CALCULATIONS NEED TO BE SIGNED BY
 OWNER/AGENT ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 3) MECHANICAL PLAN SUBMITTED HAVE TO MUCH FLOOR PLAN
 DETAIL ON THEM AND DUCT DESIGN IS FADED THEY ARE
 DIFFICULT TO READ.CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, SEE F.B.C. 106.1.1.
  
 4) WHEN RESUBMITTING MECHANICAL PLANS PLEASE HAVE THEM
 APPEAR SEMI-PROFESSIONAL AND HAVE ALL PERTINENT
 INFORMATION ON THEM (JOB ADDRESS, DESIGNER'S
 INFORMATION & SIGNATURE, EQUIPMENT SCHEDULE, ETC.
  
 5) MECHANICAL PLAN SHOWS A 16' SUPPLY AND A 18" RETURN
 DUCT GOING OFF THE PAGE, PLEASE SHOW WERE THEY ARE
 GOING.
  
 6) RETURN AIR WILL BE NEEDED IN BEDROOM #4, SEE 2004
 FBC/R M1602.4.
  
 7) BUILDING AND ELECTRICAL PLAN SHOW THE A/C CONDENSER
 UNIT IN A DIFFERENT LOCATION THEN THE MECHANICAL PLAN
 DOES, PLEASE CORRECT.
  
 8) SHOW LOCATION OF THE CLOTHES DRYER VENT ON THE
 MECHANICAL PLAN, BE ADVISED THE CLOTHES DRYER VENT MAY
 NOT DISCHARGE NEAR THE A/C CONDENSER UNIT, SEE 2004
 FBC/R 401.5.2
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-29 Cont ID  
Sent By tgordon Date 2007-08-29 Time 13:30 Rev Time 0.25
Received By tgordon Date 2007-08-29 Time 13:30 Sent To P
Notes
2007-08-29 13:40:33PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA
 ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS).
  
 *** DENIED ***
 1) SUBMIT ENERGY CALCULATIONS PER 2004 FBC 13-101.2.2.
  
 2) SUBMIT COOLING LOAD CALCULATIONS PER 2004 FBC
 13-607.1.ABC.1.
  
 3) MECHANICAL PERMIT #07080419 HAS BEEN APPLIED FOR AND
 BUILDING PLANS SHOW AN A/C SYSTEM TO BE INSTALLED BUT
 NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. PLEASE
 SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC CITY
 OF WPB AMEND. 106.3.5.4 (10).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2008-04-14 Cont ID  
Sent By mperson Date 2008-04-14 Time 15:50 Rev Time 0.00
Received By mperson Date 2008-04-14 Time 15:50 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2008-03-25 Cont ID  
Sent By mperson Date 2008-03-25 Time 08:30 Rev Time 0.00
Received By mperson Date 2008-03-25 Time 08:30 Sent To B
Notes
2008-03-25 09:11:25PLUMBING PLAN REVIEW:
 DENIED 4TH TIME
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2006 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE
 DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY.
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE
 PREVIOUS REVIEWS, 9/6/07, 10/17/07 AND 11/27/07:
  
 1. SHEET 2, SANITARY RISER DIAGRAM: THE WASHING
 MACHINE AND SINK IN THE UTILITY ROOM MUST DRAIN
 DOWNSTREAM OF THE NEW WET VENTED BATHROOM GROUP. PER
 FBC, PLUMBING, SECTION *909.1 WET VENT PERMITTED.
  
 ****RESPONSE NOTED, HOWEVER THE RESUBMITTED RISER
 DIAGRAM HAS NOT BEEN REVISED TO INDICATE THE WASHING
 MACHINE AND SINK IN THE UTILITY ROOM TO DRAIN
 DOWNSTREAM OF THE NEW WET VENTED BATHROOM GROUP.
  
 2. **OK** COMMENT ADDRESSED.
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE
 PREVIOUS REVIEW, 10/17/07 AND 11/27/07:
  
 3. **OK** COMMENT ADDRESSED.
  
 4. THE RESUBMITTED ENERGY CALCULATIONS ARE INCOMPLETE
 FOR THE ADDITION DUE TO THE FACT THAT THE WATER HEATER
 IS IN THE NEW ADDITION UTILITY ROOM AND THE ENERGY
 CALCULATIONS ARE INDICATING PER (14) HOT WATERSYSTEM
 TYPE, N/A. PER THE FOLLOWING CHAPTER 13 ENERGY
 EFFICIENCY SECTION 13-101.0 GENERAL. THIS CODE IS A
 STATEWIDE UNIFORM CODE AND SHALL NOT BE MADE MORE
 STRINGENT OR LENIENT BY LOCAL GOVERNMENT. THE CODE
 PROVIDES FOR A UNIFORM STANDARD OF ENERGY EFFICIENCY
 BY, AT A MINIMUM, SETTING FORTH MINIMUM REQUIREMENTS
 FOR EXTERIOR ENVELOPES, LIGHTING, ELECTRICAL
 DISTRIBUTION, AND SELECTION OF HEATING, LIGHTING,
 VENTILATION, AIR CONDITIONING AND SERVICE WATER HEATING
 SYSTEMS. IT SHALL APPLY TO ALL NEW BUILDINGS, TO
 ADDITIONS TO EXISTING BUILDINGS AND MANUFACTURED HOMES,
 TO RENOVATIONS TO EXISTING BUILDINGS, BOTH PUBLIC AND
 PRIVATE, WITH CERTAIN EXCEPTIONS, TO CHANGES OF
 OCCUPANCY TYPE, TO THE SITE-INSTALLED COMPONENTS AND
 FEATURES OF A MANUFACTURED HOMES AT THEIR FIRST SET-UP,
 AND TO THE INSTALLATION OR REPLACEMENT OF BUILDING
 SYSTEMS AND COMPONENTS WITH NEW PRODUCTS FOR WHICH
 THERMAL EFFICIENCY STANDARDS ARE SET BY THIS CODE. NEW
 BUILDINGS, WITH EXCEPTION OF THOSE EXEMPTED BELOW, AND
 IN ACCORDANCE WITH THE SPECIFIC EXCEPTIONS OF
 INDIVIDUAL SECTIONS SHALL BE DESIGNED TO COMPLY WITH
 SUBCHAPTER 13-4 OR 13-6 OF THIS CODE.
 **NOTE: THE WATER HEATER IN THE NEW ADDITION UTILITY
 ROOM SHALL COMPLY PER THE FOLLOWING AND BE INDICATED ON
 THE RESUBMITTED ENERGY CALCULATIONS:
  
 A} 13-101.2.2 ADDITIONS.
 B} TABLE 13-612.1.ABC.3.2, MINIMUM PERFORMANCE
 STANDARDS, WATER HEATING EQUIPMENT.
  
 ****RESPONSE NOTED, HOWEVER THE ENERGY CALCULATIONS
 NEED TO BE SIGNED BY OWNER/AGENT PER FBC 13-103.3.
  
 5. SEE ATTACHED IMPORTANT NOTICE FS 553.80(2)(B)
 DESIGN PROFESSIONAL DOCUMENTS REGUARDING FOUR (4) TIMES
 THE FEE.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-11-27 Cont ID  
Sent By mperson Date 2007-11-27 Time 08:18 Rev Time 0.00
Received By mperson Date 2007-11-27 Time 08:18 Sent To M
Notes
2007-11-27 08:59:14PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS
 TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED 3RD TIME:
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE
 PREVIOUS REVIEWS, 9/6/07 OR 10/17/07:
  
 1. SHEET 2, SANITARY RISER DIAGRAM: THE WASHING
 MACHINE AND SINK IN THE UTILITY ROOM MUST DRAIN
 DOWNSTREAM OF THE WET VENTEDBATHROOM GROUP. PER FBC,
 PLUMBING, SECTION *909.1 WET VENT PERMITTED.
  
 2. SHEET 2, SANITARY RISER DIAGRAM A CLEANOUT IS
 REQUIRED AT THE BASE OF THE WASTE STACK IN THE PROPOSED
 BATHROOM. PER FBC, PLUMBING, SECTION *708.3.4 BASE OF
 STACK.
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE
 PREVIOUS REVIEW, 10/17/07:
  
 3. SHEET 2, SANITARY RISER DIAGRAM: THE WASHING
 MACHINE IS "S" TRAPPED AND A VENT IS REQUIRED. PER FBC,
 PLUMBING, SECTIONS *1002.3 PROHIBITED TRAPS AND
 *901.2.1 VENTING REQUIRED.
  
 4. THE RESUBMITTED ENERGY CALCULATIONS ARE INCOMPLETE
 FOR THE ADDITION DUE TO THE FACT THAT THE WATER HEATER
 IS IN THE NEW ADDITION UTILITY ROOM AND THE ENERGY
 CALCULATIONS ARE INDICATING PER (14) HOT WATERSYSTEM
 TYPE, N/A. PER THE FOLLOWING CHAPTER 13 ENERGY
 EFFICIENCY SECTION 13-101.0 GENERAL. THIS CODE IS A
 STATEWIDE UNIFORM CODE AND SHALL NOT BE MADE MORE
 STRINGENT OR LENIENT BY LOCAL GOVERNMENT. THE CODE
 PROVIDES FOR A UNIFORM STANDARD OF ENERGY EFFICIENCY
 BY, AT A MINIMUM, SETTING FORTH MINIMUM REQUIREMENTS
 FOR EXTERIOR ENVELOPES, LIGHTING, ELECTRICAL
 DISTRIBUTION, AND SELECTION OF HEATING, LIGHTING,
 VENTILATION, AIR CONDITIONING AND SERVICE WATER HEATING
 SYSTEMS. IT SHALL APPLY TO ALL NEW BUILDINGS, TO
 ADDITIONS TO EXISTING BUILDINGS AND MANUFACTURED HOMES,
 TO RENOVATIONS TO EXISTING BUILDINGS, BOTH PUBLIC AND
 PRIVATE, WITH CERTAIN EXCEPTIONS, TO CHANGES OF
 OCCUPANCY TYPE, TO THE SITE-INSTALLED COMPONENTS AND
 FEATURES OF A MANUFACTURED HOMES AT THEIR FIRST SET-UP,
 AND TO THE INSTALLATION OR REPLACEMENT OF BUILDING
 SYSTEMS AND COMPONENTS WITH NEW PRODUCTS FOR WHICH
 THERMAL EFFICIENCY STANDARDS ARE SET BY THIS CODE. NEW
 BUILDINGS, WITH EXCEPTION OF THOSE EXEMPTED BELOW, AND
 IN ACCORDANCE WITH THE SPECIFIC EXCEPTIONS OF
 INDIVIDUAL SECTIONS SHALL BE DESIGNED TO COMPLY WITH
 SUBCHAPTER 13-4 OR 13-6 OF THIS CODE.
 **NOTE: THE WATER HEATER IN THE NEW ADDITION UTILITY
 ROOM SHALL COMPLY PER THE FOLLOWING AND BE INDICATED ON
 THE RESUBMITTED ENERGY CALCULATIONS:
  
 A} 13-101.2.2 ADDITIONS.
 B} TABLE 13-612.1.ABC.3.2, MINIMUM PERFORMANCE
 STANDARDS, WATER HEATING EQUIPMENT.
  
 THE FOLLOWING IS A NEW COMMENT:
  
 5. SEE ATTACHED IMPORTANT NOTICE FS 553.80(2)(B)
 DESIGN PROFESSIONAL DOCUMENTS REGUARDING FOUR (4) TIMES
 THE FEE.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-10-17 Cont ID  
Sent By mperson Date 2007-10-17 Time 09:47 Rev Time 0.00
Received By mperson Date 2007-10-17 Time 09:47 Sent To M
Notes
2007-10-17 11:08:18DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FBC-2004 WITH 05 & 06 REVISIONS, CHAPTER 13, ENERGY
 EFFICIENCY.
 ** FLORIDA ADMINISTRATIVE CODE (FAC).
 ** FLORIDA STATUTES (FS).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 THE RESUBMITTED PLUMBING PLAN REVIEW TO MEET CODE
 COMPLIANCE:
  
 1. SHEET 2, SANITARY RISER DIAGRAM: THE WASHING
 MACHINE AND SINK MUST DRAIN DOWNSTREAM OF THE WET
 VENTED BATHROOM GROUP PER FBC-2004 W/REV., PLUMBING,
 SECTION 909.1
 WET VENT PERMITTED: ONLY THE FIXTURES
 WITHIN THE BATHROOM GROUPS SHALL CONNECT
 TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT.
  
 2. SHEET 2, SANITARY RISER DIAGRAM: THE WASHING
 MACHINE IS "S" TRAPPED PER FBC-2004 W/REV., PLUMBING,
 SECTION 1002.3 "S" TRAPS ARE PROHIBITED.
  
 3. SHEET 2, SANITARY RISER DIAGRAM A CLEANOUT IS
 REQUIRED AT THE BASE OF THE WASTE STACK IN THE PROPOSED
 BATHROOM PER FBC-2004 W/REV., PLUMBING SECTION
 708.3.4.
  
 4. THE RESUBMITTED ENERGY CALCULATIONS ARE INCOMPLETE
 FOR THE ADDITION DUE TO THE FACT THAT A WATER HEATER IS
 IN THE NEW ADDITION UTILITY ROOM AND THE ENERGY
 CALCULATIONS ARE INDICATINGPER (14) HOT WATER SYSTEM
 TYPE, N/A. PER THE FOLLOWING CHAPTER 13 ENERGY
 EFFICIENCY SECTION 13-101.0 GENERAL. THIS CODE IS A
 STATEWIDE UNIFORM CODE AND SHALL NOT BE MADE MORE
 STRINGENT OR LENIENT BY LOCAL GOVERNMENT. THE CODE
 PROVIDES FOR A UNIFORM STANDARD OF ENERGY EFFICIENCY
 BY, AT A MINIMUM, SETTING FORTH MINIMUM REQUIREMENTS
 FOR EXTERIOR ENVELOPES, LIGHTING, ELECTRICAL
 DISTRIBUTION, AND SELECTION OF HEATING, LIGHTING,
 VENTILATION, AIR CONDITIONING AND SERVICE WATER HEATING
 SYSTEMS. IT SHALL APPLY TO ALL NEW BUILDINGS, TO
 ADDITIONS TO EXISTING BUILDINGS AND MANUFACTURED HOMES,
 TO RENOVATIONS TO EXISTING BUILDINGS, BOTH PUBLIC AND
 PRIVATE, WITH CERTAIN EXCEPTIONS, TO CHANGES OF
 OCCUPANCY TYPE, TO THE SITE-INSTALLED COMPONENTS AND
 FEATURES OF A MANUFACTURED HOMES AT THEIR FIRST SET-UP,
 AND TO THE INSTALLATION OR REPLACEMENT OF BUILDING
 SYSTEMS AND COMPONENTS WITH NEW PRODUCTS FOR WHICH
 THERMAL EFFICIENCY STANDARDS ARE SET BY THIS CODE. NEW
 BUILDINGS, WITH EXCEPTION OF THOSE EXEMPTED BELOW, AND
 IN ACCORDANCE WITH THE SPECIFIC EXCEPTIONS OF
 INDIVIDUAL SECTIONS SHALL BE DESIGNED TO COMPLY WITH
 SUBCHAPTER 13-4 OR 13-6 OF THIS CODE.
 NOTE: THE WATER HEATER IN THE NEW ADDITION UTILITY ROOM
 SHALL COMPLY PER THE FOLLOWING AND BE INDICATED ON THE
 RESUBMITTED ENERGY CALCULATIONS:
  
 A} 13-101.2.2 ADDITIONS.
 B} TABLE 13-612.1.ABC.3.2, MINIMUM PERFORMANCE
 STANDARDS, WATER HEATING EQUIPMENT.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-09-06 Cont ID  
Sent By mperson Date 2007-09-06 Time 08:15 Rev Time 0.00
Received By mperson Date 2007-09-06 Time 08:15 Sent To B
Notes
2007-09-06 08:46:08DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING WITH 2006 REVISIONS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET 2 PLUMBING RISER DIAGRAM: THE WASHING MACHINE
 BRANCH DRAIN, DRAINAGE STACK ANDTRAP ARE SIZED WRONG
 PER FBC-2004 PLUMBING WITH 2006 REVISIONS PER THE
 FOLLOWING CODE SECTIONS. PLEASE CORRECT AND RESUBMIT.
  
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING. PLEASE INDICATE THE WASHING MACHINE
 STANDPIPE ON THE RESUBMITTAL.
  
 2. SHEET 2 PLUMBING RISER DIAGRAM: THE WASHING MACHINE
 AND SINK IN THE UTILITY ROOM MUST DISCHARGE DOWNSTREAM
 OF THE PROPOSED WET VENTED BATHROOM PER FBC-2004
 PLUMBING WITH 2006 REVISIONS FOLLOWING CODE SECTION.
 PLEASE CORRECT AND RESUBMIT.
  
 (A) SECTION 909.1 WET VENT PERMITTED: ONLY THE
 FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO
 THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT.
 NOTE: WHERE THE PROPOSED 3 INCH TO THE EXISTING
 SANITARY SYSTEM IS INDICATED IT ALSO MUST DISCHARGE
 DOWNSTREAM OF THE EXISTING WET VENTED BATHROOMS. PLEASE
 INDICATE THIS ON THE RESUBMITTAL.
  
 3. SHEET 2 PLUMBING RISER DIAGRAM: PER FBC-2004
 PLUMBING WITH 2006 REVISIONS SECTION 708.3.4 BASE OF
 STACK. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH
 WASTE OR SOIL STACK. PLEASE CORRECT AND RESUBMIT.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK
 ON THE INDICATED PLAN SHEETS BY THIS PLANS EXAMINER FOR
 REFERENCE FOR THE RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  
  
  

Review Stop Z ZONING
Rev No 5 Status P Date 2008-04-09 Cont ID  
Sent By choops Date 2008-04-09 Time 10:35 Rev Time 0.00
Received By choops Date 2008-04-09 Time 10:35 Sent To E
Notes
2008-04-09 10:36:22***APPROVED - RESUB #4 (RESTAMPED PLANS)***
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 4 Status P Date 2008-03-21 Cont ID  
Sent By choops Date 2008-03-21 Time 10:34 Rev Time 0.00
Received By choops Date 2008-03-21 Time 10:34 Sent To E
Notes
2008-03-21 10:35:14***APPROVED - RESUB #3***
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 3 Status F Date 2007-11-14 Cont ID  
Sent By choops Date 2007-11-14 Time 14:47 Rev Time 0.00
Received By choops Date 2007-11-14 Time 14:47 Sent To E
Notes
2007-11-14 14:49:16***FAILED - RESUB #2***
  
  
 REPEAT COMMENT:
  
 1)NEW CONSTRUCTION MUST MEET MINIMUM REQUIREMENTS
 SET FORTH IN SECTION 94-72 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS.THE PROPOSED ADDITION MUST
 MAINTAIN A MINIMUM OF 5' SIDE SETBACK WITH A TOTAL OF
 15' BETWEEN THE TWO SIDES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2007-10-10 Cont ID  
Sent By choops Date 2007-10-10 Time 14:49 Rev Time 0.00
Received By choops Date 2007-10-10 Time 14:49 Sent To E
Notes
2007-10-10 14:52:30***FAILED - RESUB #1***
  
  
 1)NEW CONSTRUCTION MUST MEET MINIMUM REQUIREMENTS
 SET FORTH IN SECTION 94-72 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS.THE PROPOSED ADDITION MUST
 MAINTAIN A MINIMUM OF 5' SIDE SETBACK WITH A TOTAL OF
 15' BETWEEN THE TWO SIDES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-08-15 Cont ID  
Sent By choops Date 2007-08-15 Time 14:14 Rev Time 0.00
Received By choops Date 2007-08-15 Time 14:14 Sent To E
Notes
2007-08-15 14:17:36***FAILED***
  
  
 1)PLEASE INDICATE ELEVATION DIMENSIONS FROM GRADE.
  
 2)INDICATE ANY PROPOSED OR RELOCATED A/C EQUIPMENT
 (IF ANY) WITH SETBACK DIMENSIONS TO THE PROPERTY
 LINES.
  
 3)PROVIDE A DEMOLITION PLAN.
  
 4)SHOW SCOPE OF WORK ON SURVEYS WITH SETBACK
 DIMENSIONS TO THE PROPERTY LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720