| Plan Review Stops For Permit 07080394 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-28 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-09-28 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2007-09-28 18:12:05 | BUILDING PLAN REVIEW | | | PERMIT: 07080394 | | | ADD: 1655 PBL BLVD | | | CONT: MJS CONSTRION | | | TEL: (561615-9348 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION: PASS | | | | | | 1)OK | | | | | | 2)OK | | | | | | 3)OK | | | | | | 4)OK | | | | | | 5)FL S. S. 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6).THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-25 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-25 |
Time |
05:14 |
Sent To |
|
|
| Notes |
| 2007-08-25 07:21:49 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07080394 | | | ADD: 1655 PBL BLVD | | | CONT: MJS CONSTRION | | | TEL: (561615-9348 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 3)PROVIDE AND EXISTING FLOOR PLAN SHOWING ALL | | | INTERIOR WALLS AND THE PROPOSED FLOOR PLAN INDICATING | | | WHICH WALLS WILL BE REMOVED. ANY DEMOLITION WILL | | | REQUIRE A DEMOLITION PERMIT PRIOR TO THE COMMENCEMENT | | | OF THE WORK. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS ETC. FBC. 106.1.1. | | | | | | 4)THE PLANS SHALL BE DESIGNED TO THE 2004 FBC/ WITH | | | 2006 REVISIONS. SEE PROJECT DATAIS MISSING THE | | | INFORMATIONREGARDING THE 2006 REVISIONS. | | | | | | 5)FL S. S. 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLYCOMMENCE WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6).THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-22 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-22 |
Time |
07:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-19 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-19 |
Time |
07:39 |
Sent To |
P |
|
| Notes |
| 2007-09-19 07:54:56 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | COMMENT FROM PREVIOUS REVIEW DONE ON 8/28/07: | | | | | | 2}PER CHAPTER 13 FBC, SUBCHAPTER 13-400.0.C.4, | | | PROVIDE PERFORMANCE CALCULATIONS FOR REVIEW PER | | | 13-415.2. AND CERTIFICATION PER 13-103.1.2. | | | THIS COMMENT MUST BE ADDRESSED PER THE FOLLOWING: | | | | | | 13-400.0.C.4 RENOVATED BUILDINGS. | | | RENOVATED BUILDINGS SHALL, WHEN APPLICABLE (SEE SECTION | | | 202), MEET THE EFFICIENCIES LISTED ON FORM 400C FOR | | | COMPONENTS BEING CHANGED OR SHALL COMPLY WITH THE | | | ENVELOPE OR SYSTEMS CRITERIA IN METHOD B OF FLA/COM FOR | | | THE COMPONENTS BEING CHANGED. EXISTING BUILDINGS NOT | | | MEETING THE DEFINITION OF A RENOVATION IN WHICH NEW | | | HEATING, COOLING, WATER HEATING, ELECTRICAL OR LIGHTING | | | SYSTEMS ARE INSTALLED SHALL MEET THE BASIC PRESCRIPTIVE | | | MINIMUM EFFICIENCIES LISTED IN THIS CODE FOR THE | | | SYSTEM(S) BEING CHANGED. | | | | | | 13-400.3.ABC.2 CODE COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY TO THE BUILDING OFFICIAL THAT THE BUILDING IS | | | IN COMPLIANCE WITH THE REQUIREMENTS OF CHAPTER 13 OF | | | THIS CODE PRIOR TO RECEIVING THE PERMIT TO BEGIN | | | CONSTRUCTION OR RENOVATION. | | | | | | THE RESPONSE THAT THE "G.C. WILL PROVIDE"GIVEN AUGUST | | | 29TH, IS ACCEPTABLE, BUT PER 13-400.3ABC.2 IT MUST BE | | | SUBMITTED WITH THE PLANS TO VERIFY COMPLIANCE AT THE | | | REVIEW LEVEL. ALSO IT HAS BEEN DETERMINED BY THIS | | | OFFICE THAT THE INTENT OF THIS ARTICLE DOES NOT MANDATE | | | A "CERTIFICATE" BUT"THE CERTIFIED FLA/COM | | | CALCULATION PRINTOUT OR FORM 400C SHALL BE A PART OF | | | THE PLANS AND SPECIFICATIONS SUBMITTED FOR PERMITTING." | | | THEREFORE FORM 400C COULD BE USED INSTEAD OF METHOD "B" | | | WHICH REQUIRES A FLA/COM CALCULATION PRINTOUT. BUT | | | DENSITY AND LIGHTING CONTROLS MUST BE SUBMITTED FOR | | | REVIEW, AND THE FIXTURE SCHEDULE MUST AGREE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-28 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-28 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2007-08-28 16:17:37 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} PLEASE INDICATE THE CODE CYCLES THIS PROJECT WAS | | | DESIGNED UNDER, 2005 NEC,ADD TO NOTES FOR CLARITY IN | | | THE FIELD AND RECORD RETENTION. SEE "CODES" SHEET "T". | | | | | | 2}PER CHAPTER 13 FBC, SUBCHAPTER 13-400.0.C.4, | | | PROVIDE PERFORMANCE CALCULATIONS FOR REVIEW PER | | | 13-415.2. AND CERTIFICATION PER 13-103.1.2. | | | | | | 3} SHEET E2 PANEL 9CL HAS A 200 AMP CIRCUIT BREAKER. | | | TABLE 450.3(B) SHOWS THAT THE SECONDARY OF THE 45 KVA | | | TRANSFORMER MUST HAVE OCP AT NOT MORE THAN 125%, OR THE | | | NEXT HIGHER STANDARD BREAKER, 175 AMP IN THIS CASE. | | | PLEASE FIELD VERIFY, EVEN IF THE FEED IS EXISTING IT | | | MUST BE CORRECTED. ALSO INDICATE THE CONDUCTOR SIZES. | | | | | | PLEASE REMOVE OLD SHEETS, INSERT NEW | | | ONES, SUBMIT OLD SHEETS TO EXPEDITE | | | REVIEW AND SUBMIT WRITTEN RESPONSE TO | | | THE COMMENTS MADE IN THIS REVIEW. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-15 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-15 |
Time |
12:46 |
Sent To |
E |
|
| Notes |
| 2007-10-15 12:57:04 | *****UNSAT***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;PLAN SHEETS A1.1 AND E1 WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-01 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-01 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2007-10-01 11:07:04 | *****UNSAT***** | | | | | | | | | THE FOLLOWING PROVISO COMMENTS FROM THE PREVIOUS FIRE | | | PLAN REVIEW NEED TO BE ADDRESSED: | | | | | | 1.ON SHEET T, THE PROJECT SITE IS SHOWN AS SUITE 903C | | | WHEREAS ALL OTHER REFERENCES ARE TO SUITE 903.PLEASE | | | EXPLAIN OR CLARIFY. | | | | | | 2.ON SHEET T, ADD TO "CODES"NFPA 241, STANDARD FOR | | | SAFEGUARDING CONSTRUCTION, ALTERATION, OR DEMOLITION | | | OPERATIONS, 2000 EDITION. | | | | | | 3.ON SHEET GN, AMEND NOTE 2.8 TO REFLECT THAT | | | COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL BE | | | REMOVED DAILY OR MORE FREQUENTLY AS NECESSARY FOR SAFE | | | OPERATIONS. | | | | | | 4.ON SHEET E1 AND E2, THE SUITE NUMBER SHALL BE | | | INCLUDED WITH THE NUMERICAL ADDRESS LOCATED IN THE | | | TITLE BLOCK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-28 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-28 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2007-08-28 10:29:58 | *****PROVISO***** | | | | | | | | | THE APPROPIATE PLAN SHEET(S) WILL BE FIRE-STAMPED WHEN | | | THE FOLLOWING COMMENTS HAVE BEEN ADDRESSED: | | | | | | 1.ON SHEET T, THE PROJECT SITE IS SHOWN AS SUITE 903C | | | WHEREAS ALL OTHER REFERENCES ARE TO SUITE 903.PLEASE | | | EXPLAIN OR CLARIFY. | | | | | | 2.ON SHEET T, ADD TO "CODES"NFPA 241, STANDARD FOR | | | SAFEGUARDING CONSTRUCTION, ALTERATION, OR DEMOLITION | | | OPERATIONS, 2000 EDITION. | | | | | | 3.ON SHEET GN, AMEND NOTE 2.8 TO REFLECT THAT | | | COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL BE | | | REMOVED DAILY OR MORE FREQUENTLY AS NECESSARY FOR SAFE | | | OPERATIONS. | | | | | | 4.ON SHEET E1 AND E2, THE SUITE NUMBER SHALL BE | | | INCLUDED WITH THE NUMERICAL ADDRESS LOCATED IN THE | | | TITLE BLOCK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-05 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-05 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2007-10-15 15:27:01 | 10/15/07--TO "BTROBAUG" DESK/RESUB | | 2007-10-15 11:00:02 | TO "BOB"#15 | | 2007-10-05 12:02:01 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-12 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-12 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2007-09-15 09:57:14 | TO BOB SPACE #3 | | 2007-09-12 15:45:13 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-05 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-14 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2007-08-23 13:49:12 | TO "BOB"#14 | | 2007-08-14 11:28:26 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-24 |
Time |
10:40 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-08-24 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2007-08-24 10:41:11 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-28 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-28 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-05 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-05 |
Time |
15:43 |
Sent To |
PC |
|
| Notes |
| 2007-09-05 16:03:45 | DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SEE BUILDING PLAN REVIEW COMMENTS 3# AND #4 AND | | | COMPLY ON THE RESUBMITTAL. | | | | | | 2. PER FBC-2004 WITH 2006 REVISIONS PLUMBING, TABLE | | | 403.1(2) A DRINKING FOUNTAIN IS REQUIRED. PLEASE | | | CLEARLY INDICATE AN EXISTING ONE IN THE COMMON AREA OR | | | PROVIDE ONE IN THE PROPOSED RENOVATION. IF ONE IS | | | PROVIDED IN THE PROPOSED RENOVATION A SANITARY | | | ISOMETRIC RISER DIAGRAM AND A WATER ISOMETRIC RISER | | | DIAGRAM ARE ALSO REQURED PER FBC-2004 CHAPTER 1 SECTION | | | 106.3.5.1.3, AND MUST BE ADA COMPLIANT PER FBC-2004 | | | CHAPTER 11 FLORIDA ACCESSIBILITY CODE SECTIONS 11-4.15 | | | THRU 11-4.15.5 (ELEVATION DETAIL REQUIRED) AND | | | 11-4.1.3(10) FOR INDIVIDUALS WHO HAVE DIFFICULTY | | | BENDING AND STOOPING. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-27 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-27 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2007-08-27 15:42:07 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|