Plan Review Details - Permit 07080394
Plan Review Stops For Permit 07080394
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-09-28 Cont ID  
Sent By mjacobs Date 2007-09-28 Time 18:12 Rev Time 0.00
Received By mjacobs Date 2007-09-28 Time 17:16 Sent To  
Notes
2007-09-28 18:12:05BUILDING PLAN REVIEW
 PERMIT: 07080394
 ADD: 1655 PBL BLVD
 CONT: MJS CONSTRION
 TEL: (561615-9348
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: PASS
  
 1)OK
  
 2)OK
  
 3)OK
  
 4)OK
  
 5)FL S. S. 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6).THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-25 Cont ID  
Sent By mjacobs Date 2007-08-25 Time 07:29 Rev Time 0.00
Received By mjacobs Date 2007-08-25 Time 05:14 Sent To  
Notes
2007-08-25 07:21:49 
 BUILDING PLAN REVIEW
 PERMIT: 07080394
 ADD: 1655 PBL BLVD
 CONT: MJS CONSTRION
 TEL: (561615-9348
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)2004 FBC EXISTING
 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 3)PROVIDE AND EXISTING FLOOR PLAN SHOWING ALL
 INTERIOR WALLS AND THE PROPOSED FLOOR PLAN INDICATING
 WHICH WALLS WILL BE REMOVED. ANY DEMOLITION WILL
 REQUIRE A DEMOLITION PERMIT PRIOR TO THE COMMENCEMENT
 OF THE WORK. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS ETC. FBC. 106.1.1.
  
 4)THE PLANS SHALL BE DESIGNED TO THE 2004 FBC/ WITH
 2006 REVISIONS. SEE PROJECT DATAIS MISSING THE
 INFORMATIONREGARDING THE 2006 REVISIONS.
  
 5)FL S. S. 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLYCOMMENCE WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6).THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-10-22 Cont ID  
Sent By btrobaug Date 2007-10-22 Time 07:45 Rev Time 0.00
Received By btrobaug Date 2007-10-22 Time 07:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-09-19 Cont ID  
Sent By btrobaug Date 2007-09-19 Time 11:39 Rev Time 0.00
Received By btrobaug Date 2007-09-19 Time 07:39 Sent To P
Notes
2007-09-19 07:54:56 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 COMMENT FROM PREVIOUS REVIEW DONE ON 8/28/07:
  
 2}PER CHAPTER 13 FBC, SUBCHAPTER 13-400.0.C.4,
 PROVIDE PERFORMANCE CALCULATIONS FOR REVIEW PER
 13-415.2. AND CERTIFICATION PER 13-103.1.2.
 THIS COMMENT MUST BE ADDRESSED PER THE FOLLOWING:
  
 13-400.0.C.4 RENOVATED BUILDINGS.
 RENOVATED BUILDINGS SHALL, WHEN APPLICABLE (SEE SECTION
 202), MEET THE EFFICIENCIES LISTED ON FORM 400C FOR
 COMPONENTS BEING CHANGED OR SHALL COMPLY WITH THE
 ENVELOPE OR SYSTEMS CRITERIA IN METHOD B OF FLA/COM FOR
 THE COMPONENTS BEING CHANGED. EXISTING BUILDINGS NOT
 MEETING THE DEFINITION OF A RENOVATION IN WHICH NEW
 HEATING, COOLING, WATER HEATING, ELECTRICAL OR LIGHTING
 SYSTEMS ARE INSTALLED SHALL MEET THE BASIC PRESCRIPTIVE
 MINIMUM EFFICIENCIES LISTED IN THIS CODE FOR THE
 SYSTEM(S) BEING CHANGED.
  
 13-400.3.ABC.2 CODE COMPLIANCE CERTIFICATION.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY TO THE BUILDING OFFICIAL THAT THE BUILDING IS
 IN COMPLIANCE WITH THE REQUIREMENTS OF CHAPTER 13 OF
 THIS CODE PRIOR TO RECEIVING THE PERMIT TO BEGIN
 CONSTRUCTION OR RENOVATION.
  
 THE RESPONSE THAT THE "G.C. WILL PROVIDE"GIVEN AUGUST
 29TH, IS ACCEPTABLE, BUT PER 13-400.3ABC.2 IT MUST BE
 SUBMITTED WITH THE PLANS TO VERIFY COMPLIANCE AT THE
 REVIEW LEVEL. ALSO IT HAS BEEN DETERMINED BY THIS
 OFFICE THAT THE INTENT OF THIS ARTICLE DOES NOT MANDATE
 A "CERTIFICATE" BUT"THE CERTIFIED FLA/COM
 CALCULATION PRINTOUT OR FORM 400C SHALL BE A PART OF
 THE PLANS AND SPECIFICATIONS SUBMITTED FOR PERMITTING."
 THEREFORE FORM 400C COULD BE USED INSTEAD OF METHOD "B"
 WHICH REQUIRES A FLA/COM CALCULATION PRINTOUT. BUT
 DENSITY AND LIGHTING CONTROLS MUST BE SUBMITTED FOR
 REVIEW, AND THE FIXTURE SCHEDULE MUST AGREE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-28 Cont ID  
Sent By btrobaug Date 2007-08-28 Time 16:20 Rev Time 0.00
Received By btrobaug Date 2007-08-28 Time 15:08 Sent To  
Notes
2007-08-28 16:17:37 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} PLEASE INDICATE THE CODE CYCLES THIS PROJECT WAS
 DESIGNED UNDER, 2005 NEC,ADD TO NOTES FOR CLARITY IN
 THE FIELD AND RECORD RETENTION. SEE "CODES" SHEET "T".
  
 2}PER CHAPTER 13 FBC, SUBCHAPTER 13-400.0.C.4,
 PROVIDE PERFORMANCE CALCULATIONS FOR REVIEW PER
 13-415.2. AND CERTIFICATION PER 13-103.1.2.
  
 3} SHEET E2 PANEL 9CL HAS A 200 AMP CIRCUIT BREAKER.
 TABLE 450.3(B) SHOWS THAT THE SECONDARY OF THE 45 KVA
 TRANSFORMER MUST HAVE OCP AT NOT MORE THAN 125%, OR THE
 NEXT HIGHER STANDARD BREAKER, 175 AMP IN THIS CASE.
 PLEASE FIELD VERIFY, EVEN IF THE FEED IS EXISTING IT
 MUST BE CORRECTED. ALSO INDICATE THE CONDUCTOR SIZES.
  
 PLEASE REMOVE OLD SHEETS, INSERT NEW
 ONES, SUBMIT OLD SHEETS TO EXPEDITE
 REVIEW AND SUBMIT WRITTEN RESPONSE TO
 THE COMMENTS MADE IN THIS REVIEW.
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-10-15 Cont ID  
Sent By mawillia Date 2007-10-15 Time 13:00 Rev Time 0.00
Received By mawillia Date 2007-10-15 Time 12:46 Sent To E
Notes
2007-10-15 12:57:04*****UNSAT*****
  
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ADDRESSED;PLAN SHEETS A1.1 AND E1 WERE STAMPED,
 INITIALED, AND DATED.
  
  
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-10-01 Cont ID  
Sent By mawillia Date 2007-10-01 Time 11:07 Rev Time 0.00
Received By mawillia Date 2007-10-01 Time 10:57 Sent To  
Notes
2007-10-01 11:07:04*****UNSAT*****
  
  
 THE FOLLOWING PROVISO COMMENTS FROM THE PREVIOUS FIRE
 PLAN REVIEW NEED TO BE ADDRESSED:
  
 1.ON SHEET T, THE PROJECT SITE IS SHOWN AS SUITE 903C
 WHEREAS ALL OTHER REFERENCES ARE TO SUITE 903.PLEASE
 EXPLAIN OR CLARIFY.
  
 2.ON SHEET T, ADD TO "CODES"NFPA 241, STANDARD FOR
 SAFEGUARDING CONSTRUCTION, ALTERATION, OR DEMOLITION
 OPERATIONS, 2000 EDITION.
  
 3.ON SHEET GN, AMEND NOTE 2.8 TO REFLECT THAT
 COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL BE
 REMOVED DAILY OR MORE FREQUENTLY AS NECESSARY FOR SAFE
 OPERATIONS.
  
 4.ON SHEET E1 AND E2, THE SUITE NUMBER SHALL BE
 INCLUDED WITH THE NUMERICAL ADDRESS LOCATED IN THE
 TITLE BLOCK.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-08-28 Cont ID  
Sent By mawillia Date 2007-08-28 Time 10:30 Rev Time 0.00
Received By mawillia Date 2007-08-28 Time 09:59 Sent To  
Notes
2007-08-28 10:29:58*****PROVISO*****
  
  
 THE APPROPIATE PLAN SHEET(S) WILL BE FIRE-STAMPED WHEN
 THE FOLLOWING COMMENTS HAVE BEEN ADDRESSED:
  
 1.ON SHEET T, THE PROJECT SITE IS SHOWN AS SUITE 903C
 WHEREAS ALL OTHER REFERENCES ARE TO SUITE 903.PLEASE
 EXPLAIN OR CLARIFY.
  
 2.ON SHEET T, ADD TO "CODES"NFPA 241, STANDARD FOR
 SAFEGUARDING CONSTRUCTION, ALTERATION, OR DEMOLITION
 OPERATIONS, 2000 EDITION.
  
 3.ON SHEET GN, AMEND NOTE 2.8 TO REFLECT THAT
 COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL BE
 REMOVED DAILY OR MORE FREQUENTLY AS NECESSARY FOR SAFE
 OPERATIONS.
  
 4.ON SHEET E1 AND E2, THE SUITE NUMBER SHALL BE
 INCLUDED WITH THE NUMERICAL ADDRESS LOCATED IN THE
 TITLE BLOCK.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 12:01 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 12:01 Sent To  
Notes
2007-10-15 15:27:0110/15/07--TO "BTROBAUG" DESK/RESUB
2007-10-15 11:00:02TO "BOB"#15
2007-10-05 12:02:01WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-12 Cont ID  
Sent By adarroug Date 2007-09-12 Time 15:44 Rev Time 0.00
Received By adarroug Date 2007-09-12 Time 15:44 Sent To  
Notes
2007-09-15 09:57:14TO BOB SPACE #3
2007-09-12 15:45:13WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-05 Cont ID  
Sent By mperson Date 2007-09-05 Time 16:05 Rev Time 0.00
Received By mperson Date 2007-08-14 Time 11:28 Sent To  
Notes
2007-08-23 13:49:12TO "BOB"#14
2007-08-14 11:28:26WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-08-24 Cont ID  
Sent By tgordon Date 2007-08-24 Time 10:40 Rev Time 0.15
Received By tgordon Date 2007-08-24 Time 10:40 Sent To  
Notes
2007-08-24 10:41:11NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-09-28 Cont ID  
Sent By mperson Date 2007-09-28 Time 09:19 Rev Time 0.00
Received By mperson Date 2007-09-28 Time 09:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-09-05 Cont ID  
Sent By mperson Date 2007-09-05 Time 15:44 Rev Time 0.00
Received By mperson Date 2007-09-05 Time 15:43 Sent To PC
Notes
2007-09-05 16:03:45DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SEE BUILDING PLAN REVIEW COMMENTS 3# AND #4 AND
 COMPLY ON THE RESUBMITTAL.
  
 2. PER FBC-2004 WITH 2006 REVISIONS PLUMBING, TABLE
 403.1(2) A DRINKING FOUNTAIN IS REQUIRED. PLEASE
 CLEARLY INDICATE AN EXISTING ONE IN THE COMMON AREA OR
 PROVIDE ONE IN THE PROPOSED RENOVATION. IF ONE IS
 PROVIDED IN THE PROPOSED RENOVATION A SANITARY
 ISOMETRIC RISER DIAGRAM AND A WATER ISOMETRIC RISER
 DIAGRAM ARE ALSO REQURED PER FBC-2004 CHAPTER 1 SECTION
 106.3.5.1.3, AND MUST BE ADA COMPLIANT PER FBC-2004
 CHAPTER 11 FLORIDA ACCESSIBILITY CODE SECTIONS 11-4.15
 THRU 11-4.15.5 (ELEVATION DETAIL REQUIRED) AND
 11-4.1.3(10) FOR INDIVIDUALS WHO HAVE DIFFICULTY
 BENDING AND STOOPING.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-27 Cont ID  
Sent By choops Date 2007-08-27 Time 15:41 Rev Time 0.00
Received By choops Date 2007-08-27 Time 15:41 Sent To  
Notes
2007-08-27 15:42:07*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.