| Plan Review Stops For Permit 07080321 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-17 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-17 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-30 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-10 |
Time |
11:28 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-23 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-23 |
Time |
10:43 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-10-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-09 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-09 |
Time |
09:37 |
Sent To |
PC |
|
| Notes |
| 2007-10-09 09:51:59 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 WITH 05 & 06 REVISIONS, FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | **THE RESUBMITTED PLANS WITH THE REQUESTED MP GAS | | | REGULATOR INFORMATION NEEDS THE FOLLOWING CORRECTIONS | | | PER THE SUBMITTED MANUFACTURER'S SPECIFICATION | | | REGULATOR INFORMATION: | | | | | | 1. THE MP REGULATOR MAXITROL325-7L HAS A MAXIMUM | | | INDIVIDUAL LOAD OF 900,000 BTU'S THE PROPOSED GENERATOR | | | HAS A 960,000 LOAD CAPACITY. THE INDICATED MAXITROL MP | | | REGULATOR 325-7L ON THE RESUBMITTED PLANS IS TO SMALL | | | FOR THE PROPOSED 960,000 GENERATOR. PLEASE RESUBMIT | | | WITH THE PROPER SIZED MP REGULATOR. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-14 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-14 |
Time |
14:44 |
Sent To |
B |
|
| Notes |
| 2007-09-14 14:55:21 | DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS WITH 2006 REVISIONS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | NOTE: NOT ALL CUT SECTIONS OF PIPE HAVE CORRESPONDING | | | LENGTHS INDICATED. | | | | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | NOTE: NEED THE LONGEST LENGTH OF SYSTEM TO COMPLETE THE | | | PLAN REVIEW. | | | | | | 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | NOTE: NEED MANUFACTURER SPECIFICATION SHEETS OF THE MP | | | REGULATOR WITH THE MAKE, MODEL NUMBER, LOAD CAPACITY | | | AND A LISTING FROM A NATIONALLY RECOGNIZED TESTING | | | LABORATORY (NRTL). | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-11 |
Time |
08:31 |
Sent To |
G |
|
| Notes |
| 2007-10-11 08:32:05 | TO "G" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-21 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-21 |
Time |
15:55 |
Sent To |
G |
|
| Notes |
| 2007-09-21 15:56:05 | TO "G" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-13 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2007-08-13 11:34:07 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-15 |
Time |
11:24 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-08-15 |
Time |
11:24 |
Sent To |
E |
|
| Notes |
| 2007-08-15 11:28:35 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED EQUIPMENT | | | PERMANENTLY INSTALLED EQUIPMENT POWERED BY INTERNAL | | | COMBUSTION ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND NFPA | | | 37.NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES | | | (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT | | | FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES | | | HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT | | | REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF | | | ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, | | | AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 | | | EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES | | | OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION | | | INTAKES. | | | 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS | | | LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE | | | TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF | | | STRUCTURE. | | | PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL | | | EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, | | | GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED | | | CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E. | | | FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES | | | AROUND EQUIPMENT FOR SERVICING,AND PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-14 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-14 |
Time |
13:07 |
Sent To |
E |
|
| Notes |
| 2007-08-14 13:07:46 | APPROVED GENERATOR LOCATION.HOA REQUIREMENTS TO BE | | | MET. |
|
|