Plan Review Details - Permit 07080321
Plan Review Stops For Permit 07080321
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-09-17 Cont ID  
Sent By shill Date 2007-09-17 Time 12:09 Rev Time 0.00
Received By shill Date 2007-09-17 Time 12:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-09-14 Cont ID  
Sent By tgordon Date 2007-08-30 Time 14:13 Rev Time 0.00
Received By btrobaug Date 2007-09-10 Time 11:28 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2007-10-23 Cont ID  
Sent By mperson Date 2007-10-23 Time 10:43 Rev Time 0.00
Received By mperson Date 2007-10-23 Time 10:43 Sent To PC
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2007-10-09 Cont ID  
Sent By mperson Date 2007-10-09 Time 09:37 Rev Time 0.00
Received By mperson Date 2007-10-09 Time 09:37 Sent To PC
Notes
2007-10-09 09:51:59DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 WITH 05 & 06 REVISIONS, FUEL GAS.
 ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION
 REQUIREMENTS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 **THE RESUBMITTED PLANS WITH THE REQUESTED MP GAS
 REGULATOR INFORMATION NEEDS THE FOLLOWING CORRECTIONS
 PER THE SUBMITTED MANUFACTURER'S SPECIFICATION
 REGULATOR INFORMATION:
  
 1. THE MP REGULATOR MAXITROL325-7L HAS A MAXIMUM
 INDIVIDUAL LOAD OF 900,000 BTU'S THE PROPOSED GENERATOR
 HAS A 960,000 LOAD CAPACITY. THE INDICATED MAXITROL MP
 REGULATOR 325-7L ON THE RESUBMITTED PLANS IS TO SMALL
 FOR THE PROPOSED 960,000 GENERATOR. PLEASE RESUBMIT
 WITH THE PROPER SIZED MP REGULATOR.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-09-14 Cont ID  
Sent By mperson Date 2007-09-14 Time 14:45 Rev Time 0.00
Received By mperson Date 2007-09-14 Time 14:44 Sent To B
Notes
2007-09-14 14:55:21DENIED
 REFERENCE:
 ** FBC-2004 FUEL GAS WITH 2006 REVISIONS.
 ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION
 REQUIREMENTS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 NOTE: NOT ALL CUT SECTIONS OF PIPE HAVE CORRESPONDING
 LENGTHS INDICATED.
  
 2. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
 NOTE: NEED THE LONGEST LENGTH OF SYSTEM TO COMPLETE THE
 PLAN REVIEW.
  
 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
 NOTE: NEED MANUFACTURER SPECIFICATION SHEETS OF THE MP
 REGULATOR WITH THE MAKE, MODEL NUMBER, LOAD CAPACITY
 AND A LISTING FROM A NATIONALLY RECOGNIZED TESTING
 LABORATORY (NRTL).
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-11 Cont ID  
Sent By adarroug Date 2007-10-11 Time 08:31 Rev Time 0.00
Received By adarroug Date 2007-10-11 Time 08:31 Sent To G
Notes
2007-10-11 08:32:05TO "G" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-21 Cont ID  
Sent By adarroug Date 2007-09-21 Time 15:55 Rev Time 0.00
Received By adarroug Date 2007-09-21 Time 15:55 Sent To G
Notes
2007-09-21 15:56:05TO "G" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-17 Cont ID  
Sent By adarroug Date 2007-09-17 Time 15:51 Rev Time 0.00
Received By adarroug Date 2007-08-13 Time 11:33 Sent To  
Notes
2007-08-13 11:34:07TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-08-30 Cont ID  
Sent By tgordon Date 2007-08-15 Time 11:24 Rev Time 0.20
Received By tgordon Date 2007-08-15 Time 11:24 Sent To E
Notes
2007-08-15 11:28:35*** PROVISO ***
 1) PER 2004 FBC, FUEL GAS - POWERED EQUIPMENT
 PERMANENTLY INSTALLED EQUIPMENT POWERED BY INTERNAL
 COMBUSTION ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND NFPA
 37.NFPA 37 INSTALLATION & USE OF STATIONARY
 COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES
 (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT
 FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES
 HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT
 REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE
 RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF
 ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS,
 AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE
 MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1
 EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES
 OR
 WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION
 INTAKES.
 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS
 LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE
 TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF
 STRUCTURE.
 PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL
 EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK,
 GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED
 CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E.
 FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS.
 FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES
 AROUND EQUIPMENT FOR SERVICING,AND PROVIDE
 MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE
 FOR THE FIELD INSPECTOR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729

Review Stop Z ZONING
Rev No 1 Status P Date 2007-08-14 Cont ID  
Sent By choops Date 2007-08-14 Time 13:07 Rev Time 0.00
Received By choops Date 2007-08-14 Time 13:07 Sent To E
Notes
2007-08-14 13:07:46APPROVED GENERATOR LOCATION.HOA REQUIREMENTS TO BE
 MET.