| Plan Review Stops For Permit 07080259 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-27 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-27 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-06 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-06 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2007-09-06 10:29:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)SEAL IS TO INCLUDE A DATE, SEE FAC61G15-23.002. | | | | | | 2.)CERTIFICATE OF AUTHORIZATOIN REQUIRED AND IS TO BE | | | ON EACH SHEET, SEE FAC61G15-23 AND FS471, ALSO | | | FBPE.ORG. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-12 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-12 |
Time |
11:55 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-18 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-18 |
Time |
09:41 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-15 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-15 |
Time |
11:49 |
Sent To |
P |
|
| Notes |
| 2007-08-15 11:57:53 | | | | | | | | | | | | | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | THE ENGINEERING FIRM LISTED ON THE TITLE BLOCK SHALL | | | INDICATE THE CERTIFICATE OF AUTHORIZATIONNUMBER ALONG | | | WITH OTHER INFORMATION REQUIRED BY 61G15-23.002 | | | FLORIDA ADMINISTRATIVE CODE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-23 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-23 |
Time |
14:21 |
Sent To |
Z |
|
| Notes |
| 2007-10-23 14:22:00 | NOTE: THERE IS NO POOL HEATER GAS OR ELECTRIC. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-26 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-26 |
Time |
15:38 |
Sent To |
B |
|
| Notes |
| 2007-09-26 15:41:44 | NOTE: RESUBMITTED PLANS NOW HAVE A GAS POOL HEATER: | | | | | | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-16 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-16 |
Time |
14:04 |
Sent To |
B |
|
| Notes |
| 2007-08-16 14:06:05 | NOTE: THERE IS NO GAS OR ELECTRIC POOL HEATER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-10 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-10 |
Time |
16:02 |
Sent To |
E |
|
| Notes |
| 2007-10-10 16:03:30 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-12 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-12 |
Time |
09:47 |
Sent To |
Z |
|
| Notes |
| 2007-09-12 09:47:46 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-06 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-13 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2007-08-13 09:26:20 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-23 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-23 |
Time |
14:20 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-26 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-26 |
Time |
15:15 |
Sent To |
G |
|
| Notes |
| 2007-09-26 15:37:20 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 WITH 05 & 06 REVISIONS. SECTIONS 424.2 AND | | | R4101 SWIMMING POOLS. | | | ** FBC-2004 WITH 05 & 06 REVISIONS,PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | | ** FLORIDA STATUTES (FS). | | | | | | DUE TO THE FACT THAT THE DESIGN PROFESSIONAL HAS | | | CHANGED THE FOLLOWING CORRECTIONS/INFORMATION ARE | | | REQUIRED FOR PLUMBING PLAN REVIEW TO MEET CODE | | | COMPLIANCE: | | | | | | 1. PLEASE CORRELATE THE EQUIPMENT LAYOUT WITH THE | | | LEGEND ON THE RESUBMITTAL. THE EQUIPMENT LAYOUT IS | | | MISLABELED AS B, C, D, E AND F, IT SHOULD BE LABELED A, | | | B, C, D AND E TO CORRELATE WITH THE LEGEND. THE PIPING | | | FOR THE EQUIPMENT LAYOUT IS ALSO MISLABELED AS 4, 5, 6, | | | AND 8, IT SHOULD BE LABELED AS 1, 2, 3 AND 4 TO | | | CORRELATE WITH THE LEGEND. PLEASE CORRECT AND CORRELATE | | | ON THE RESUBMITTAL. | | | | | | 2. FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | | | | 3. FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK | | | BY THIS PLAN EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-16 |
Time |
11:43 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-08-16 |
Time |
11:43 |
Sent To |
G |
|
| Notes |
| 2007-08-16 14:03:59 | DENIED | | | REFERENCE: | | | ** FBC-2004 SECTIONS 424.2 OR R4101 SWIMMING POOLS. | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1) COMPLY WITH FBC-2004 SEC 424.2, OR | | | FBCR-2004 SEC R4101 PRIVATE SWIMMING | | | POOLS. (ADD TO NOTES) | | | | | | 2) FBC-2004 SEC 424.2.6.1, OR FBCR-2004 | | | SEC R4101.6.1 ENGINEERING DESIGN, | | | CONSTRUCTION AND WORKMANSHIP. | | | ANSI/NSPI-5. (ADD TO NOTES) | | | | | | 3) FBC-2004 424.2.6.6.2, OR FBCR-2004 | | | SEC R4101.6.6.2 SHOW COMPLIANCE WITH | | | ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUFACTURER INFORMATION FOR SUCTION | | | FITTINGS (MAIN DRAINS). | | | (SUBMITTAL OR ADD TO NOTES) | | | | | | 4) FBC-2004424.2.6.6.3, OR FBCR-2004 SEC R4101.6.6.3 | | | (1,2,3) ENTRAPMENT AVOIDANCE. | | | NOTE: POOL DETAIL OF THE VENT PIPE SIZE IS TO VAGUE | | | PLEASE CLARIFY THE EXACT SIZE OF THE VENT ON THE | | | RESUBMITTAL AND PLEASE ADD TO THE VENT DETAIL THE | | | FOLLOWING "LABEL VENT: POOL SAFETY DEVICE - DO NOT | | | HANDLE" | | | | | | 5) FBC-2004 SEC. 424.2.6.6.5, OR | | | FBCR-2004 SEC. R4101.6.6.5 WHERE | | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | | NOT GREATER THAN 12" BELOW THE MINIMUM | | | OPERATING WATER LEVEL OR AS AN | | | ATTACHMENT TO THE SKIMMER. | | | (DETAIL REQUIRED WITH THE MAKE AND MODEL NUMBER OF THE | | | CLEANER FITTING) | | | | | | 6) FBC-2004 SEC. 424.2.7.2, OR | | | FBCR-2004 SEC. R4101.7.2 PUMPS AND | | | EQUIPMENT SHALL BE MOUNTED ON A | | | SUBSTANTIAL BASE IN A MANNER THAT WILL | | | ELIMINATE STRAIN ON PIPING.SLAB SHALL | | | BE A NOMINAL 4" THICK. (DETAIL REQUIRED) | | | | | | 7) FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC. | | | R4101.9 WATER SUPPLY, LOCAL ORD. | | | #2853-95, BACKFLOW REQUIRED ON WATER | | | SERVICE.(ADD TO NOTES) | | | | | | 8) FBC-2004 SEC. 424.2.12.1, OR | | | FBCR-2004 SEC. R4101.12.1 PRESSURE | | | TESTS. PER MANUFACTURE RECOMMENDATIONS, | | | NO AIR TEST SHALL BE APPROVED FOR PVC | | | PIPE AND FITTINGS. (ADD TO NOTES) | | | | | | 9) FBC-2004 SEC. 424.2.13.2, OR | | | FBCR-2004 SEC.R4101.13.2 JOINTS AND | | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING.(ADD TO | | | NOTES) | | | | | | 10) FBC-2004 SEC. 424.2.20 OR FBCR-2004 SEC. R4101.20 | | | FILTERS. THE ENTIRE DESIGN OF MATCHED COMPONENTS SHALL | | | HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER | | | OF POOL WATER IN 12 HOURS OR LESS. | | | NOTE: PLEASE PROVIDE THE TURNOVER TIME OF THE POOL ON | | | THE RESUBMITTAL. | | | | | | 11) THE ENGINEERING FIRM LISTED ON THE TITLE BLOCK | | | SHALL INDICATE THE CERTIFICATE OF AUTHORIZATION NUMBER | | | ALONG WITH OTHER INFORMATION REQUIRED BY 61G15-23.002 | | | FLORIDA ADMINISTRATIVE CODE. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-23 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-23 |
Time |
14:30 |
Sent To |
B |
|
| Notes |
| 2007-10-23 14:34:25 | ***APPROVED - RESTAMPED PLANS - RESUB #2*** | | | | | | SENT TO "B" - SH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-13 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-13 |
Time |
14:43 |
Sent To |
E |
|
| Notes |
| 2007-09-13 14:44:24 | FENCE ENCLOSURE ON PERMIT #07080926 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-14 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-14 |
Time |
08:07 |
Sent To |
E |
|
| Notes |
| 2007-08-14 08:13:30 | ***FAILED*** | | | | | | | | | 1)INDICATE POOL EQUIPMENT WITH SETBACK DIMENSIONS TO | | | THE PROPERTY LINES. | | | | | | 2)SETBACK DIMENSIONS TO BE MEASURED FROM PROPERTY | | | LINE...NOT EAST LINE OF LOT 54. | | | | | | 3)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE | | | COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT SHALL | | | BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO THE | | | MINIMUM STANDARDS PROVIDED BELOW. | | | | | | AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | | | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | 4)CLARIFY SCOPE OF WORK: GARAGE SLAB TO BE ADDED | | | UNDER THIS PERMIT? | | | | | | 5)PROVIDE ELEVATION DETAIL OF DECK (IF ABOVE GRADE). | | | | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|