Plan Review Details - Permit 07080190
Plan Review Stops For Permit 07080190
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-09-04 Cont ID  
Sent By amorse Date 2007-09-04 Time 16:01 Rev Time 0.00
Received By amorse Date 2007-09-04 Time 16:01 Sent To PC
Notes
2007-09-04 16:19:22 
  
 DENIED
  
 1)THE MAXIMUM ALLOWABLE SLOPE IS 1 IN 8,PLEASE
 PROVIDE ELEVATION AT PROPERTY LINE AND AT HOUSE TO
 DETERMINE COMPLIANCE
  
 2)HANDRAILS ARE REQUIRED ON AT LEAST ONE SIDE OF ALL
 RAMPS THAT EXCEED 1 IN 12 SLOPE, THE HANDRAIL HEIGHT
 MEASURED FROM THE SURFACE OF THE RAMP SHALL BE 34 - 38
 INCHES AND THE GRIP SIZE SHALL CONFORM WITH R311.5.6.3
 FBC RES. AND SHALL BE CONTINUOUS FOR THE FULL LENGTH OF
 THE RAMP
  
 3)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE, AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1 FBC*
 DRAWINGS SHALL CONTAIN ONLY THE PLANS AND ELEVATIONS OF
 THE WORK TO BE PERMITTED
  
 4)PER 106.1.3 FBC* THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR
 PLANS AND SPECIFICATIONS "NO WHITE OUT, PENCIL OR INK"
  
 5)TERMITE TREATMENT IS REQUIRED ON ALL EXTERIOR
 CONCRETE WITHIN 1 FOOT OF PRIMARY STRUCTURE PER
 1816.1.6 OR R320.1.6 FBC
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-09-04 Time   Rev Time 0.00
Received By mmiller Date 2007-08-07 Time 17:40 Sent To  
Notes
2007-08-07 17:40:53SENT TO ZONING BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2007-08-08 Cont ID  
Sent By choops Date 2007-08-08 Time 18:04 Rev Time 0.00
Received By choops Date 2007-08-08 Time 18:04 Sent To B
Notes
***NONE***