2007-08-14 07:27:43****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)ENHANCED FASTENING PATTERN NOT CLEAR.YOU STATE
 "3 ROW 6" OC STAGGERED" FOR THE PERIMETER AND CORNER.
 IS THIS THREE FIELD ROWS OR ONE LAP AND TWO FIELD ROWS?
 SPECIFICATION NEEDS TO BE CLEAR AS ONE IS NOT COMPLIANT
 FOR THE CORNER DESIGN PRESSURE OF -107.69.I HAVE
 SUGGESTED AN ENHANCED FASTENING PATTERN BUT YOU HAVE
 CONTINUED TO RESUBMIT A NAILING PATTERN DIFFERENT FROM
 THE PATTERN DISCUSSED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-08-10 Cont ID  
Sent By shill Date 2007-08-10 Time 15:18 Rev Time 0.00
Received By shill Date 2007-08-10 Time 15:18 Sent To  
Notes
2007-08-10 15:32:10****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)SELECT WHICH FASTENER YOU ARE USING.CALCULATIONS
 CANNOT BE RUN WITHOUT THIS INFORMATION.IT APPEARS
 THAT YOUR ENHANCED NAILING PATTERN OF 8"OC FOR CORNER
 ZONE (EXPOSURE C) IS NOT COMPLIANT WITH RAS117.IT IS
 STILL NOT CLEAR WHY WE DISCUSS ONE NAILING ON THE
 TELEPHONE BUT YOU CONTINUE TO RESUBMIT WITH A NAILING
 PATTERN WHICH IS DIFFERENT.BE ADVISED THAT THE
 NAILING PATTERN YOU HAVE SPECIFIED DOES NOT APPEAR TO
 BE COMPLIANT BUT I CANNOT DETERMINE THIS UNTIL YOU
 SELECT A FASTENER.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-08-08 Cont ID  
Sent By shill Date 2007-08-08 Time 17:38 Rev Time 0.00
Received By shill Date 2007-08-08 Time 17:38 Sent To  
Notes
2007-08-08 17:56:35****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 FROM PREVIOUS LIST, NOT ADDRESSED:
  
 _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.THE ASSEMBLY YOU SELECTED IS FOR
 INSULATED DECK, YOU STATED THAT YOU ARE INSTALLING A
 TORCH DOWN (NO INSULATION).
  
 _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.YOU HAVE
 SUBMITTED A LETTER BUT BE ADVISED THAT WE DISCUSSED 4"
 SPACING AND YOU HAVE WRITTEN 12".COMPLIANCE WITH
 RAS117 CANNOT BE DETERMINED UNTIL YOU SELECT AN
 ASSEMBLY AND INDICATE WHICH FASTENER YOU ARE USING.
  
 _XX_ 7.)ADDRESSED BY DECLARING EXPOSURE C.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-06 Cont ID  
Sent By shill Date 2007-08-06 Time 14:53 Rev Time 0.00
Received By shill Date 2007-08-06 Time 14:53 Sent To  
Notes
2007-08-06 14:57:03****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 FROM PREVIOUS LIST, NOT ADDRESSED:
  
  
 _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
  
 _XX_ 7.)PROVIDE INFORMATION IN REGARDS TO THE
 SURROUNDING TERRAIN AND DECLARE EXPOSURE CATEGORY
 FBC1609.6.2.1(2), FBC R301.2.1.4.NOTE THAT THE
 DEFINITION FOR EXPOSURE C HAS CHANGED EFFECTIVE
 DECEMBER 8, 2006 FBC1609.4, FBC R301.2.1.4.
  
 NOTE THAT I CALLED CONTRACTOR AFTER FIRST REVIEW AND
 ASKED IF HE UNDERSTOOD THE ISSUES OF EXPOSURE CATEGORY
 AND ENHANCED FASTENING.CONTRACTOR INDICATED THAT HE
 DID UNDERSTAND AND DID NOT NEED ASSISTANCE.DECLARE
 THIS JOB AS EXPOSURE B OR EXPOSURE C AND PROVIDE
 INFORMATION IN REGARDS TO SURROUNDING AREA.THIS MAY
 BE DONE WITH AERIALS WHICH MAY BE AVAILABLE AT
 WWW.PBCGOV.COM/PAPA.THIS WILL BE REQUIRED TO
 DETERMINE DESIGN PRESSURES AND ENHANCED FASTENING.
  
 ALL COMMENTS MUST BE ADDRESSED PRIOR TO PERMIT
 ISSUANCE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-06 Cont ID  
Sent By shill Date 2007-08-06 Time 11:47 Rev Time 0.00
Received By shill Date 2007-08-06 Time 11:47 Sent To  
Notes
2007-08-06 11:49:46****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13.
  
 _XX_2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
  
 ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.IF YOU SELECT FOAM
 ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72.
  
 _XX_ 7.)PROVIDE INFORMATION IN REGARDS TO THE
 SURROUNDING TERRAIN AND DECLARE EXPOSURE CATEGORY
 FBC1609.6.2.1(2), FBC R301.2.1.4.NOTE THAT THE
 DEFINITION FOR EXPOSURE C HAS CHANGED EFFECTIVE
 DECEMBER 8, 2006 FBC1609.4, FBC R301.2.1.4.