Plan Review Details - Permit 07080132
| Plan Review Stops For Permit 07080132 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-14 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-14 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-14 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-14 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2007-08-14 07:27:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)ENHANCED FASTENING PATTERN NOT CLEAR.YOU STATE | | | "3 ROW 6" OC STAGGERED" FOR THE PERIMETER AND CORNER. | | | IS THIS THREE FIELD ROWS OR ONE LAP AND TWO FIELD ROWS? | | | SPECIFICATION NEEDS TO BE CLEAR AS ONE IS NOT COMPLIANT | | | FOR THE CORNER DESIGN PRESSURE OF -107.69.I HAVE | | | SUGGESTED AN ENHANCED FASTENING PATTERN BUT YOU HAVE | | | CONTINUED TO RESUBMIT A NAILING PATTERN DIFFERENT FROM | | | THE PATTERN DISCUSSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-10 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-10 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2007-08-10 15:32:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)SELECT WHICH FASTENER YOU ARE USING.CALCULATIONS | | | CANNOT BE RUN WITHOUT THIS INFORMATION.IT APPEARS | | | THAT YOUR ENHANCED NAILING PATTERN OF 8"OC FOR CORNER | | | ZONE (EXPOSURE C) IS NOT COMPLIANT WITH RAS117.IT IS | | | STILL NOT CLEAR WHY WE DISCUSS ONE NAILING ON THE | | | TELEPHONE BUT YOU CONTINUE TO RESUBMIT WITH A NAILING | | | PATTERN WHICH IS DIFFERENT.BE ADVISED THAT THE | | | NAILING PATTERN YOU HAVE SPECIFIED DOES NOT APPEAR TO | | | BE COMPLIANT BUT I CANNOT DETERMINE THIS UNTIL YOU | | | SELECT A FASTENER. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-08 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-08 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2007-08-08 17:56:35 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LIST, NOT ADDRESSED: | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS.THE ASSEMBLY YOU SELECTED IS FOR | | | INSULATED DECK, YOU STATED THAT YOU ARE INSTALLING A | | | TORCH DOWN (NO INSULATION). | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES.YOU HAVE | | | SUBMITTED A LETTER BUT BE ADVISED THAT WE DISCUSSED 4" | | | SPACING AND YOU HAVE WRITTEN 12".COMPLIANCE WITH | | | RAS117 CANNOT BE DETERMINED UNTIL YOU SELECT AN | | | ASSEMBLY AND INDICATE WHICH FASTENER YOU ARE USING. | | | | | | _XX_ 7.)ADDRESSED BY DECLARING EXPOSURE C. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-06 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-06 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2007-08-06 14:57:03 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LIST, NOT ADDRESSED: | | | | | | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | | | _XX_ 7.)PROVIDE INFORMATION IN REGARDS TO THE | | | SURROUNDING TERRAIN AND DECLARE EXPOSURE CATEGORY | | | FBC1609.6.2.1(2), FBC R301.2.1.4.NOTE THAT THE | | | DEFINITION FOR EXPOSURE C HAS CHANGED EFFECTIVE | | | DECEMBER 8, 2006 FBC1609.4, FBC R301.2.1.4. | | | | | | NOTE THAT I CALLED CONTRACTOR AFTER FIRST REVIEW AND | | | ASKED IF HE UNDERSTOOD THE ISSUES OF EXPOSURE CATEGORY | | | AND ENHANCED FASTENING.CONTRACTOR INDICATED THAT HE | | | DID UNDERSTAND AND DID NOT NEED ASSISTANCE.DECLARE | | | THIS JOB AS EXPOSURE B OR EXPOSURE C AND PROVIDE | | | INFORMATION IN REGARDS TO SURROUNDING AREA.THIS MAY | | | BE DONE WITH AERIALS WHICH MAY BE AVAILABLE AT | | | WWW.PBCGOV.COM/PAPA.THIS WILL BE REQUIRED TO | | | DETERMINE DESIGN PRESSURES AND ENHANCED FASTENING. | | | | | | ALL COMMENTS MUST BE ADDRESSED PRIOR TO PERMIT | | | ISSUANCE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-06 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-06 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2007-08-06 11:49:46 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | | | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | _XX_2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY; | | | MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF | | | EACH ROOF TYPE | | | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | | | ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | | METHOD OF ATTACHMENT YOU ARE USING.IF YOU SELECT FOAM | | | ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72. | | | | | | _XX_ 7.)PROVIDE INFORMATION IN REGARDS TO THE | | | SURROUNDING TERRAIN AND DECLARE EXPOSURE CATEGORY | | | FBC1609.6.2.1(2), FBC R301.2.1.4.NOTE THAT THE | | | DEFINITION FOR EXPOSURE C HAS CHANGED EFFECTIVE | | | DECEMBER 8, 2006 FBC1609.4, FBC R301.2.1.4. |
|
|
|