Plan Review Details - Permit 07080113
Plan Review Stops For Permit 07080113
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-11-06 Cont ID  
Sent By mjacobs Date 2007-11-06 Time 10:29 Rev Time 0.00
Received By mjacobs Date 2007-11-06 Time 09:57 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-11-01 Cont ID  
Sent By mjacobs Date 2007-11-01 Time 10:40 Rev Time 0.00
Received By mjacobs Date 2007-11-01 Time 07:21 Sent To  
Notes
2007-11-01 10:40:54 
  
 BUILDING PLAN REVIEW
 PERMIT: 07080113
 ADD: 412 CLEMATIS ST.
 CONT: REDECOR, INC.
 TEL: (561)222-0223
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 3RD 11/1/07
 ACTION: DENIED
  
 1)OK
 2) OK
 4)OK
  
 5)PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THE NEW
 IMPACT STEEL DOORS AND THE PRE-CAST LINTEL. FBC
 106.3.3. THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR APPROVAL.
 NOTE: THE PRODUCT APPROVALS SHALL BE APPROVED BY THE
 DESIGNER OF RECORD.
 **NOTED**
 HOWEVER, THE NOA REPORT IS MISSING FOR THE STEEL CRAFT
 DOOR. IN THE PACKAGE THERE ARE MANY DIFFERENT TYPES OF
 DOORS WITH THE NOA NUMBER. CHOOSE THE DOOR WHICH WILL
 BE INSTALLED AT THE PROJECT AND SUBMIT THE NOA REPORT.
 THE PRODUCT APPROVAL FOR THE ROLL-UP DOOR IS NOT
 INCLUDED IN THE PACKAGE.
 **NEEW** TWO COMPLETE SETS OF PRODUCT APPROVAL SHALL BE
 SUBMITTED FOR EACH PRODUCT. ONLY ONE SET FOR EACH
 PRODUCT WAS SUBMITTED. THE ROLL-UP EXTERIOR DOOR HAS A
 MAXIMUM DESIGN PRESSURE OF 30PSF WHICH IS BELOW THE
 DESIGN PRESSURES INDICATED ON SHEET S.1. SEE TABLE
 1609.2.1(5) A 10X 10 GARAGE DOOR THE NEGATIVE PRESSURE
 IS -30.8. PROVIDE SIGNED, SEALED AND DATED CALCULATIONS
 SHOWING THAT THE ROLL-UP DOOR SUBMITTED WILL MEET THE
 PRESSURES INDICATED ON SHEET S.1 OR PROVIDE A DIFFERENT
 PRODUCT WHICH WILL MEET THE PRESSURES STATED ON THE
 PLANS, ( SHEET S.1). HI-LIGHT EACH ITEM ON THE PRODUCT
 APPROVAL FOR THE INSTALLATION OF THE PRODUCT.
  
 6)OK
 7)OK
 8)OK
 9)OK
 10) OK
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-06 Cont ID  
Sent By mjacobs Date 2007-10-06 Time 16:05 Rev Time 0.00
Received By mjacobs Date 2007-10-06 Time 08:08 Sent To  
Notes
2007-10-06 16:05:32 
  
  
  
 BUILDING PLAN REVIEW
 PERMIT: 07080113
 ADD: 412 CLEMATIS ST.
 CONT: REDECOR, INC.
 TEL: (561)222-0223
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
  
 1)OK
 2) OK
 4)OK
  
 5)PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THE NEW
 IMPACT STEEL DOORS AND THE PRE-CAST LINTEL. FBC 106.3.3
 THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR APPROVAL.
 NOTE: THE PRODUCT APPROVALS SHALL BE APPROVED BY THE
 DESIGNER OF RECORD.
 **NOTED**
 HOWEVER, THE NOA REPORT IS MISSING FOR THE STEEL CRAFT
 DOOR. IN THE PACKAGE THERE ARE MANY DIFFERENT TYPES OF
 DOORS WITH THE NOA NUMBER. CHOOSE THE DOOR WHICH WILL
 BE INSTALLED AT THE PROJECT AND SUBMIT THE NOA REPORT.
 THE PRODUCT APPROVAL FOR THE ROLL-UP DOOR IS NOT
 INCLUDED IN THE PACKAGE.
  
 6)OK
 7)OK
 8)OK
 9)OK
 10) OK
 **NEW**
 SHEET M1 SHOWS A DOUBLE DOOR AT THE REAR, HOWEVER THE
 OTHER SHEETS SHOW A SINGLE DOOR WITH A ROLL-UP DOOR
 NEXT TO IT. THE PLANS SHALL MATCH.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-22 Cont ID  
Sent By mjacobs Date 2007-08-22 Time 16:22 Rev Time 0.00
Received By mjacobs Date 2007-08-22 Time 10:57 Sent To  
Notes
2007-08-22 16:22:53BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561)###-####
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 2) 110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PROJECT IS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT
 . -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
  
 4)THE RECEPTION AND RETAIL AREA SHALL MEET THE
 REQUIREMENTS OF FBC 11-7. SHOW IN DETAIL HOW THESE
 REQUIREMENTS WILL BE MET.
  
 5)PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THE NEW
 IMPACT STEEL DOORS AND THE PRE-CAST LINTEL. FBC 106.3.3
 THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR APPROVAL.
 NOTE: THE PRODUCT APPROVALS SHALL BE APPROVED BY THE
 DESIGNER OF RECORD.
  
 6)SHEET A.3 THE LIFE SAFETY PLAN SHOWS THE TRAVEL
 PATH GOING THROUGH A WALL. THERE SEEMS TO BE AN ERROR
 WITH THIS DESIGN.
  
 7)THE LIFE SAFETY PLAN SHALL INCLUDE THE FURNITURE
 LAY-OUT IN THE OFFICE AND RETAIL AREA ALONG WITH THE
 COMMON PATH OF EGRESS TRAVEL. THE COMMON PATH OF EGRESS
 TRAVEL SHALL BE 75 FEET IN UNSPRINKLERED BUILDINGS AND
 100 FEET IN BUILDINGS WITH AUTOMATIC SPRINKLER SYSTEM.
 SEE FBC 1013 FOR MORE INFORMATION.
  
 8)FBC 1013.4.1THE MINIMUM CLEAR AISLE WIDTH SHALL
 NOT BE LESS THAN 36 INCHES.
  
 9)FBC 1210 TOILET ROOM FLOORS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE. WALLS WITHIN 2 FEET OF
 URINALS AND WATER CLOSETS SHALL HAVE SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE
 FLOOR. NOTE: PAINT ON DRYWALL IS NOT CONSIDER A ?HARD?
 SURFACE.
  
 10) SHOW ON THE PLANS WHERE THE DRYWALL CEILING WILL
 BE INSTALLED.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-02-04 Cont ID  
Sent By btrobaug Date 2008-02-04 Time 12:29 Rev Time 0.00
Received By btrobaug Date 2008-02-04 Time 12:13 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-10-30 Cont ID  
Sent By btrobaug Date 2007-10-30 Time 14:00 Rev Time 0.00
Received By btrobaug Date 2007-10-30 Time 12:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-09-26 Cont ID  
Sent By btrobaug Date 2007-09-26 Time 10:57 Rev Time 0.00
Received By btrobaug Date 2007-09-26 Time 07:04 Sent To  
Notes
2007-09-26 10:57:02 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING
 CODE, 2005 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC
 AS
 AMENDED, CHAPTER 1, AND FOUND NONCOMPLIANT WITH THE
 FOLLOWING:
  
 PROVIDE A WRITTEN RESPONSE TO THESE COMMENTS.
  
 THIS COMMENT WAS FROM THE 8/22/07 REVIEW AND WAS NOT
 ADDRESSED:
  
 2} PER 13-103.1.1, THE PERSON PREPARING THE COMPLIANCE
 CERTIFICATION MUST SIGN AND SEAL SAME. THERE IS NO
 SEAL.
  
 THESE ARE COMMENTS GENERATED BY THE CHANGES ON THE
 PLAN, SHEET E-1
  
 1} THE RELOCATED PANELS LPA AND LPB ON THE PLAN MUST
 COMPLY WITH ARTICLE 230.70(A)(1), NO MORE THAN 8? OF
 UNPROTECTED CONDUCTORS AS DETERMINED BY THE AHJ, AND
 THEREFORE MAY REQUIRE DISCONNECTS OUTSIDE. ARTICLE
 110.26 WITH REGARDS TO THE PLACEMENT OF THE LIGHTING
 CONTROL PANEL WITH RESPECT TO LPA & LPB.
  
 NOTE: SHEET E-2 SHOWS A GUTTER CONNECTING A PANEL TO
 THE LIGHTING CONTROL PANEL, AND HAS A NOTE INDICATING
 MAKE UP WORK IN LINE VOLTAGE GUTTER. THE INTENTION OF
 THAT NOTE IS UNCLEAR BUT BE AWARE OF ARTICLE 230.7
 ?CONDUCTORS OTHER THAN SERVICE CONDUCTORS SHALL NOT BE
 INSTALLED IN THE SAME SERVICE RACEWAY OR SERVICE
 CABLE?. INDICATE THE LOCATION OF THE GUTTER ON THE
 PLAN.
  
 2} LPB 9,11,13 FOR THE RTU HAS AN OCP OF 80 AMPS. THE
 MAXIMUM FUSE SIZE ON SHEET M1 IS LISTED AS 70 AMPS FOR
 THAT UNIT. PLEASE CORRELATE
  
 3} THE INSTA HOT UNITS ON SHEET E-1, ARE IN A DIFFERENT
 LOCATION THAN SHEET P.1, PLEASE CORRELATE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
 MAY BE REVIEWED. THEY WERE ON THE PLANS THE PREVIOUS
 REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-22 Cont ID  
Sent By btrobaug Date 2007-08-22 Time 09:55 Rev Time 0.00
Received By btrobaug Date 2007-08-22 Time 07:15 Sent To  
Notes
2007-08-22 09:55:28THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE PAGE #2 OF THE ENERGY GAUGE INPUT DATA REPORT,
 DOES NOT INDICATE THE CORRECT NUMBER OF FIXTURES AS
 SHOWN ON THE PLAN. CHAPTER 13.
  
 2} PER 13-103.1.1, THE PERSON PREPARING THE COMPLIANCE
 CERTIFICATION MUST SIGN AND SEAL SAME. THERE IS NO
 SEAL.
  
 3} 13-400.0.C.4 RENOVATED BUILDINGS.
 RENOVATED BUILDINGS SHALL, WHEN APPLICABLE (SEE SECTION
 202), MEET THE EFFICIENCIES LISTED ON FORM 400C FOR
 COMPONENTS BEING CHANGED OR SHALL COMPLY WITH THE
 ENVELOPE OR SYSTEMS CRITERIA IN METHOD B OF FLA/COM FOR
 THE COMPONENTS BEING CHANGED. EXISTING BUILDINGS NOT
 MEETING THE DEFINITION OF A RENOVATION IN WHICH NEW
 HEATING, COOLING, WATER HEATING, ELECTRICAL OR LIGHTING
 SYSTEMS ARE INSTALLED SHALL MEET THE BASIC PRESCRIPTIVE
 MINIMUM EFFICIENCIES LISTED IN THIS CODE FOR THE
 SYSTEM(S) BEING CHANGED.
  
 NOTE: THE RELAY PANEL ON SHEET E-2 IS INDICATING AN
 OPERATING VOLTAGE OF 120/277, THE SERVICE VOLTAGE IS
 LISTED AT 120/208. SEE INSTA HOT MANUFACTURERS RATINGS
 PRIOR TO INSTALLATION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By mawillia Date 2007-11-01 Time 13:13 Rev Time 0.00
Received By mawillia Date 2007-11-01 Time 12:54 Sent To  
Notes
2007-11-01 13:13:23*****DENIED*****
  
 THE COMMENTS FROM THE PREVIOUS PLAN REVIEWS HAVE BEEN
 ADDRESSED;PLAN SHEETSA-3 AND E-2 WERE STAMPED,
 INITIALED, AND DATED.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-10-10 Cont ID  
Sent By mawillia Date 2007-10-10 Time 14:43 Rev Time 0.00
Received By mawillia Date 2007-10-10 Time 13:48 Sent To  
Notes
2007-10-10 13:51:06*****DENIED*****
 * THE FOLLOWING COMMENTS FROM THE PREVIOUS PLAN REVIEW
 STILL NEED TO BE ADDRESSED:
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD
 TO SHEET A.0
  
 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.ADD
 TO SHEET A.0
  
 * NEW COMMENTS
  
 A.THE ADDRESS IN THE TITLE BLOCK OF SHEETS E-0, E-1,
 E-2, AND P-1 IS LISTED AS 416 CLEMATIS STREET.
  
 B.THE LOCATION OF REAR EXIT LIGHT ON SHEET A.1 DOES
 NOT CORRELATE WITH ITS LOCATION ON SHEET E-2.
  
 C.ON SHEET A.1,NO DETAIL OF WHAT THE 5 CEILING
 SYMBOLS (EXCLUDING THE EXIT LIGHTS) REPRESENT.
  
 D.IN THE LIGHTING PLAN ON SHEET E-2, DIFFERENT
 SYMBOLS ARE SHOWN FOR THE EXIT SIGN.
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-08-28 Cont ID  
Sent By mawillia Date 2007-08-28 Time 16:17 Rev Time 0.00
Received By mawillia Date 2007-08-28 Time 14:42 Sent To  
Notes
2007-08-28 16:16:30*****DENIED*****
 THIS MERCANTILE OCCUPANCY SHALL BE SUBCLASSIFIED AS
 CLASS B (AGGREGATE GROSS AREA MORE THAN 3,000 SQUARE
 BUT NOT MORE THAN 30,000 SQUARE FEET AND OCCUPYING NOT
 MORE THAN THREE STORIES.
  
  
 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 4. THE TRAVEL DISTANCE TO AN EXIT SHALL BE MEASURED ON
 THE FLOOR OR WALKING SURFACE AS PER NFPA 7.6.1, NOT AS
 INDICATED ON SHEET A.3
  
 5.PROVIDE A FURNITURE PLAN WHICH SHALL PROVIDE THE
 REVIEWER(S) WITH DETAILS SUCH AISLE CLEARANCE, TRAVEL
 DISTANCE TO NEAREST EXIT, COMMON PATHS OF TRAVEL,
 OBSTRUCTIONS TO EXITS, ETC.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-01-31 Cont ID  
Sent By adarroug Date 2008-01-31 Time 16:58 Rev Time 0.00
Received By adarroug Date 2008-01-31 Time 16:58 Sent To E
Notes
2008-01-31 16:58:42TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-12-07 Cont ID  
Sent By adarroug Date 2007-12-07 Time 15:44 Rev Time 0.00
Received By adarroug Date 2007-12-07 Time 15:44 Sent To M
Notes
2007-12-07 15:45:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-22 Cont ID  
Sent By adarroug Date 2007-10-22 Time 09:00 Rev Time 0.00
Received By adarroug Date 2007-10-22 Time 09:00 Sent To  
Notes
2007-10-27 11:18:33TO BOB BOARD SPACE #15. DVP.
2007-10-22 09:00:41WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-13 Cont ID  
Sent By adarroug Date 2007-09-13 Time 14:52 Rev Time 0.00
Received By adarroug Date 2007-09-13 Time 14:52 Sent To  
Notes
2007-09-19 17:12:47TO "BOB"#6
2007-09-13 14:53:07WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-31 Cont ID  
Sent By mperson Date 2007-08-31 Time 08:25 Rev Time 0.00
Received By mperson Date 2007-08-06 Time 17:14 Sent To  
Notes
2007-08-14 09:21:52TO "BOB"#2
2007-08-06 17:15:13WAITING FOR "BOB" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-12-10 Cont ID  
Sent By tgordon Date 2007-12-10 Time 11:57 Rev Time 0.25
Received By tgordon Date 2007-12-10 Time 11:57 Sent To  
Notes
2007-12-10 11:58:02REVISION TO MECH. PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-10-30 Cont ID  
Sent By tgordon Date 2007-10-30 Time 10:17 Rev Time 0.25
Received By tgordon Date 2007-10-30 Time 10:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-08-16 Cont ID  
Sent By tgordon Date 2007-08-16 Time 09:42 Rev Time 0.30
Received By tgordon Date 2007-08-16 Time 09:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By mperson Date 2007-11-01 Time 11:26 Rev Time 0.00
Received By mperson Date 2007-11-01 Time 11:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-09-28 Cont ID  
Sent By mperson Date 2007-09-28 Time 10:03 Rev Time 0.00
Received By mperson Date 2007-09-28 Time 10:03 Sent To  
Notes
2007-09-28 11:51:19DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 WITH 05 & O6 REVISIONS, PLUMBING.
 ** FBC-2004 WITH 05 & 06 REVISIONS, CHAPTER 13.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 **NOTE: PREVIOUS PLUMBING PLAN REVIEW COMMENTS WERE
 ADDRESSED. THE FOLOWING ARE NEW COMMENTS THAT NEED TO
 BE ADDRESSED TO MEET CODE COMPLIANCE:
  
 1. THE INSTA-HOT UNITS ON SHEET E-1, ARE BEING
 INDICATED IN A DIFFERENT LOCATION ON SHEET P-1. PLEASE
 CORRELATE THE TWO SHEETS AND PLEASE ADJUST THE WATER
 DIAGRAM ON SHEET P-1 PLUMBING FLOOR PLAN IF NEEDED.
  
 2. SHEET P-1 PLAN KEY NOTES #3, INDICATES "INSTA-HOT
 WATER HEATER, EEMAX MODEL ESP 3208, 208V, 1 PHASE, 3KW,
 14.4AMPS. THE PLANS INDICATE TWO OF THESE INSTA-HOT
 WATER HEATERS BEING INSTALLED. THE FOLLOWING SUBMITTED
 ENERGY CALCULATIONS.
 METHOD C: PRESCRIPTIVE COMPLIANCE FOR COMMERCIAL
 BUILDING PROJECT SUMMARY:
 COMPLIANCE SUMMARY: WATER HEATING SYSTEMS (NONE
 ENTERED)
 SYSTEM REPORT COMPLIANCE: WATER HEATER COMPLIANCE (NONE
 ENTERED)
 INPUT DATA REPORT: SYSTEMS, WATER HEATERS (NONE
 ENTERED)
 NOTE: PER FBC-2004 W/06 REVISIONS SECTION 13-103.1.1.1
 COMMERCIAL APPLICATIONS AND SECTION 13-412.1.ABC.1
 WATER HEATER SIZING AND DESIGN CALCULATIONS ARE
 REQUIRED.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-30 Cont ID  
Sent By mperson Date 2007-08-30 Time 16:35 Rev Time 0.00
Received By mperson Date 2007-08-30 Time 16:35 Sent To  
Notes
2007-08-30 16:56:19DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
 ** FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PLEASE PROVIDE AN ELEVATION DETAIL OF THE DRINKING
 FOUTAIN WITH THE FOLLOWING INFORMATION PER FBC-2004
 CHAPTER 11 ACCESSIBILITY REQUIREMENTS:
  
 A} 11-4.15.2, SPOUT HEIGHT.
  
 B} 11-4.15.3, SPOUT LOCATION.
  
 C} 11-4.15.4, CONTROLS.
  
 D} 11-4.15.5, CLEARANCES (1).
  
 E} 11-4.1.3(10), WHERE ONLY ONE DRINKING FOUNTAIN IS
 PROVIDED ON A FLOOR, THERE SHALL BE A DRINKING FOUNTAIN
 WHICH IS ACCESSIBLE TO INDIVIDUALS WHO USE A
 WHEELCHAIRS IN ACCORDANCE TO 11-4.15 AND ONE ACCESSIBLE
 TO THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. THIS
 CAN BE ATTAINED BY USING A HI/LO FOUNTAIN OR BY SUCH
 OTHER MEANS AS WOULD ACHIEVE THE REQUIRED ACCESSIBILITY
 FOR EACH GROUP ON EACH FLOOR. PLEASE INDICATE HOW THIS
 IS ACHIEVED ON THE RESUBMITTAL.
  
 2. PLEASE CORRELATE WHICH HLAV FAUCET IS BEING USED ON
 THE RESUBMITTAL. SHEET P.1 IN THE "PLUMBING FIXTURE
 SCHEDULE" INDICATES A SYMMONS MODEL S-20-GR AND SHEET
 A.3 IN THE "ADA NOTES AND LEGENDS" IS INDICATING AN
 AMERICAN STANDARD 7500.70-VP-002 FAUCET.
  
 3. PLEASE INDICATE ON THE RESUBMITTAL HOW THE HLAV
 FAUCET IS COMPLIANT WITH FBC-2004 CHAPTER 11, SECTION
 11-4.19.5 FAUCETS ON THE RESUBMITTAL. AN INTERNET
 SEARCH OF THE HLAV FAUCETS CAME UP EMPTY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-14 Cont ID  
Sent By choops Date 2007-08-14 Time 10:37 Rev Time 0.00
Received By choops Date 2007-08-14 Time 10:37 Sent To  
Notes
2007-08-14 10:37:31*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.