Plan Review Details - Permit 07080102
| Plan Review Stops For Permit 07080102 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-18 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-18 |
Time |
12:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-09 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-09 |
Time |
10:37 |
Sent To |
I |
|
| Notes |
| 2007-08-09 11:14:52 | | | | | | | THIS REVIEW WAS WAS MADE UNDER THE FOLLOWING CODES: THE | | | 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | | FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH | | | THE FOLLOWING: | | | | | | 1} THE PLANS ARE NOT DRAWN WITH ENOUGH CLARITY FOR | | | REVIEW OR RECORD RETENTION. PLEASE INCREASE THE SIZE OF | | | THE PLANS. | | | | | | 2} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER | | | 106.3.4.3.FBC. | | | | | | 3} SUBMIT A PANEL SCHEDULE PER 408.4 NEC AND | | | 106.3.5.4(8) FBC. | | | 408.4 CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION EVERY | | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE | | | SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE | | | DISTINGUISHED FROM ALL OTHERS. INCLUDE OCP AND | | | CONDUCTOR SIZES SO COMPLIANCE WITH 310.16 CAN BE | | | REVIEWED. | | | | | | 4} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | | METER ENCLOSURE, DISCONNECTS AND PANELS. | | | | | | 5} EGRESS LIGHTING IS REQUIRED PER 210.70(A)(2)(B). | | | | | | NOTE: RECEPTACLE SPACING MUST COMPLY WITH 210.52, 2005 | | | NEC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-12 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-12 |
Time |
15:12 |
Sent To |
E |
|
| Notes |
| 2007-09-12 15:12:51 | TO"BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-09 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-06 |
Time |
17:59 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 17:59:48 | TO "E" BOX |
|
|
|