Plan Review Details - Permit 07080046
Plan Review Stops For Permit 07080046
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-25 Cont ID  
Sent By amorse Date 2007-08-25 Time 14:27 Rev Time 0.00
Received By amorse Date 2007-08-25 Time 14:27 Sent To PC
Notes
2007-08-25 15:05:40 
  
 DENIED
  
 1)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE
 PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR
 SETBACKS
  
 2)DRAWINGS SHALL SHOW THE LOCATION OF ALLWORK,
 INCLUDING THE PROPOSED BUILDING(S) OR STRUCTURE(S) AND
 THEIR DISTANCES FROM THE EXISTING STRUCTURE(S)
  
 3)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE
 OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2
 COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER
 R401.4 FBC RES.
  
 4)PROVIDE BUILDING ELEVATIONS (TOP OF BEAM, MEAN ROOF
 HEIGHT, TOP OF OPENINGS, ETC)
  
 5)PROVIDE DOOR SIZE,NOT ON DRAWING OR IN SCHEDULE
  
 6)PROVIDE CORRECT DOOR AND WINDOW PRESSURES, BOTH ARE
 LOCATED IN ZONE 5 (MINIMUM 4 FT) PER FIG R301.2(8) FBC
 RES.
  
 7)PER R803.3.2.1 FBC RES. ZONE 3 OF ROOF SHEATHING TO
 BE NAILED AT 4" O/C
  
 8)NO HOT WATER HEATER IS SHOWN ON THE DRAWINGS, IS
 THE WASHING MACHINE TO USE COLD WATER ONLY ?
  
 9)THE WINDOW AND DOOR PRODUCT APPROVALS THAT WERE
 SUBMITTED ARE NOT IMPACT RATED, IF THESE PRODUCTS ARE
 USED IMPACT PROTECTIVE DEVICES ARE REQUIRED AND PRODUCT
 APPROVALS MUST BE SUBMITTED
  
 10)THE CITY OF WEST PALM BEACH REQUIRES THE
 FLORIDA STATE PRODUCT APPROVAL COVER SHEETS WHEN
 AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 11)NO PRODUCT APPROVAL WAS SUBMITTED FOR THE SIMPSON
 TIES THAT ARE TO BE USED
  
 12)NOTE: YALE OGRON HAVE THEIR OWN MULLIONS
 MIAMI-DADE # 06-0905.11 AND THE 1X SIZE IS MORE THAN
 ADEQUATE FOR THE 3 TYPE "A" WINDOWS THAT ARE JOINED
 TOGETHER. ALSO IT ALREADY HAS LOCAL PRODUCT APPROVAL IN
 THIS JURISDICTION SO THE MIAMI-DADE REPORT IS ALL THAT
 IS REQUIRED
  
 13)SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT
 APPLICATION OR BEFORE INSTALLATION THAT
 HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD
  
 14)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-20 Cont ID  
Sent By btrobaug Date 2007-08-20 Time 09:01 Rev Time 0.00
Received By btrobaug Date 2007-08-20 Time 08:52 Sent To P
Notes
2007-08-20 09:01:34 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT
 WITH THE FOLLOWING:
  
 1} THE PANEL SHOWN IN THE NEW LAUNDRY ROOM IS LABLED
 50 AMPS. THE RISER SHOWS A NEW 60 AMP PANEL IN THE
 GARAGE. PROVIDE A SITE PLAN INDICATING THE LOCATION OF
 ALL SERVICE EQUIPMENT SO THAT COMPLIANCE WITH ARTICLE
 230 CAN BE REVIEWED.
  
 2} A GROUNDING ELECTRODE CONDUCTOR IS REQUIRED AT THE
 SEPARATE STRUCTURE PER 250.32, SIZED PER 250.66.
 INSTALL ON THE RISER, SEE 250.52(A)(3) FOR FOOTER
 STEEL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-08-25 Time   Rev Time 0.00
Received By adarroug Date 2007-08-02 Time 16:51 Sent To  
Notes
2007-08-02 16:51:30TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By tgordon Date 2007-08-13 Time 14:27 Rev Time 0.20
Received By tgordon Date 2007-08-13 Time 14:27 Sent To E
Notes
2007-08-13 14:28:22NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-23 Cont ID  
Sent By mperson Date 2007-08-23 Time 11:04 Rev Time 0.00
Received By mperson Date 2007-08-23 Time 11:04 Sent To B
Notes
2007-08-23 11:42:05DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS OF THE PROPOSED LAUNDRY ROOM WASHING
 MACHINE.
  
 2. THE FOLLOWING IS REQUIRED FOR THE WASHING MACHINE
 PLUMBING PER FBC-2004 PLUMBING:
  
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
  
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING. PLEASE INDICATE THE STANDPIPE ON THE
 RESUBMITTAL.
  
 (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM)
 NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE 3
 INCH.
  
 (D) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.
 NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE LOCATED
 AT THE BASE OF THE STACK LOOKING TO THE OUTSIDE OF THE
 LAUNDRY ROOM OR LOCATED AT 4 FEETABOVE FINNISH FLOOR
 LOOKING TO THE INSIDE OF THE LAUNDRY ROOM.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2007-08-06 Cont ID  
Sent By choops Date 2007-08-06 Time 11:57 Rev Time 0.00
Received By choops Date 2007-08-06 Time 11:57 Sent To E
Notes
2007-08-06 12:02:45***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF THE SURVEY,
 CLEARLY SHOWING THE SCOPE OF WORK WITH SETBACK
 DIMENSIONS TO THE PROPERTY LINES.
  
 2)PERMIT APPLICATION INDICATES ADDITION OF 1,000
 SQ.FT. BUILDING SHOWN AS 10X10 (100 SQ.FT.)PLEASE
 CLARIFY.
  
 3)PLAN A-1 INDICATES PROPOSED STRUCTURE AS A
 DETACHED LAUNDRY ROOM, APPLICATION INDICATES ATTACHED,
 PLEASE CLARIFY.
  
 4)PROVIDE A FLOOR PLAN SHOWING THE CORRELATION TO
 EXISTING HOUSE.
  
 5)PROVIDE ELEVATION DIMENSIONS FROM GRADE OF THE
 PROPOSED STRUCTURE.
  
 (NOTE: ANY PROPOSED A/C EQUIPMENT, IF ANY, SHALL BE
 SHOWN WITH SETBACK DIMENSIONS TO THE PROPERTY LINES.)
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720