Plan Review Details - Permit 07071040
Plan Review Stops For Permit 07071040
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-05-16 Cont ID  
Sent By jgomez Date 2008-05-16 Time 13:19 Rev Time 0.00
Received By jgomez Date 2008-05-16 Time 13:12 Sent To PC
Notes
2008-05-16 13:19:58PROVISO ITEMS: REVISED ENERGY CALCULATIONS AND REVISED
 RAS 117 CALCULATIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-04-22 Cont ID  
Sent By jgomez Date 2008-04-22 Time 15:23 Rev Time 0.00
Received By jgomez Date 2008-04-22 Time 07:37 Sent To M
Notes
2008-04-23 10:43:16BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- FLAT ROOF SYSTEM: REVISE DESIGN PRESSURES SHOWN ON
 THE RAS 117 CALCULATIONS. SEESTRUCTURAL DRAWING S-4
 FOR CORRECT DESIGN PRESSURES CALCULATED BY THE ENGINEER
 FOR FLAT ROOF AND REVISE AS REQUIRED.THEN, RE-RUN THE
 RAS 117 CALCULATIONS AND REVISE ANCHOR SPACING AS
 REQUIRED.
  
 2- REVISE ENERGY CALCULATIONS:
 A) WALL TYPES ON ITEM #9 NEED TO INCLUDE THE WALL
 TYPES SHOWN FOR NEW ADDITION AND FOR GARAGE AREA.SEE
 PLANS AND REVISE AS REQUIRED.
  
 NOTE:
 PROVIDEREVISED INFORMATION AS SOON AS POSSIBLE TO
 AVOID ANY UNNECESSARY DELAYS OR CONFLICTS DURING
 INSPECTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-03-18 Cont ID  
Sent By jgomez Date 2008-03-18 Time 16:37 Rev Time 0.00
Received By jgomez Date 2008-03-18 Time 16:37 Sent To PC
Notes
2008-03-18 17:02:11RESIDENTIAL ADDITION AND RENOVATIONS, BUILDING REVIEW
 THIRD CHECKLIST.
 REVIEW UNDER 2004 FBC WITH 2007 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
 NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP.
  
 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) FLAT ROOF: NEED TO PROVIDE THE RAS 117
 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER
 AREAS AS REQUIRED BY GENERAL LIMITATION #7.(REPEAT
 COMMENT).INFORMATION SUBMITTED ON SHEET A-2 IS THE
 EXACT SAME INFORMATION THAT IS PROVIDED IN THE FLAT
 ROOF NOA 03-0501.05.
  
 ***NOTE: COMPONENTS AND CLADDING LOADS SPECIFIED IN THE
 STRUCTURAL DRAWINGS NEED TO BE REVISED ACCORDING TO
 TABLE R301.2(3),FIGURE R301.2(8) OF 2004 FLORIDA
 RESIDENTIALCODE AND THE DEFINITION FOR "EFFECTIVE
 WIND AREA"IN THE FBC 2004 SEC. 1609.2.
  
 ALSO, MINIMUM DIMENSION FOR ZONE "A" IS 4'-0" AS
 REQUIRED BY FIGURE R301.2(8). REVISE AS REQUIRED.
  
 B) FIXED WINDOWS. (REPEAT COMMENT). PRODUCT APPROVAL
 SUBMITTED FOR FRENCH DOORS DOESN'T HAVE THE INFORMATION
 FOR TRANSOM WINDOWS ABOVE DOORS.
  
 C) WINDOW/ DOORS MULLIONS. (REPEAT COMMENT). PRODUCT
 APPROVAL FOR FRENCH DOORS DOESN'T HAVE THE INFORMATION
 FOR MULLIONS. NEED TO PROVIDE SEPARATE PRODUCT
 APPROVAL. SEE GENERAL NOTES ON NOA SUBMITTED.
  
 ALSO, CLEARLY MARK MULLION SIZE AND ATTACHMENT TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. (REPEAT
 COMMENT).
  
 D) GARAGE DOOR SIZE AS SHOWN ON PLANS. (REPEAT
 COMMENT). PRODUCT APPROVAL IS FORWIDE DOORS UP TO
 14'-2" .THERE ARE DIFFERENT PRODUCT APPROVALS FOR
 NARROWER DOORS. TYPICALLY 8' AND 9' WIDE DOORS. PROVIDE
 SUCH PRODUCT APPROVAL.. CONTACT MANUFACTURER FOR PROPER
 PRODUCT APPROVAL.
  
 E) CLAY ROOF TILE.NO PRODUCT APPROVAL SUBMITTED
 THIS TIME.
 ***NOTE: HISTORIC DISTRICT REQUIRES CLAY TILE. SEE
 THEIR COMMENTS IN THE APPROVED DRAWINGS.
 NOA 06--0324.01 SPECIFIED BY ARCHITECT ON PRODUCT
 APPROVAL REVIEW LIST IS FOR CONCRETE TILE. REVISE AS
 REQUIRED. COORDINATE WITH HISTORIC PERSONNEL.
  
 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS. SEC. 106.3.3 CITY AMENDMENTS TO
 FBC 2004.
  
 4- ENERGY CALCULATIONS:
 A) PROVIDE CORRECT REVISED FORM. (REPEAT COMMENT).
 NEED FORM 600A-2004R.
  
 B) COMPLETE INFORMATION ON TOP OF FORM.
  
 C)AREAS SHOWN ON ITEM 6 AND 10A) DON'T MATCH AREAS
 SHOWN ON ARCHITECTURAL PLANS.REVISE AS REQUIRED.
  
 D) R VALUES SHOWN FOR WALLS AND CEILINGS DON'T MATCH
 ARCHITECTURAL PLANS. REVISE AS REQUIRED.
  
 E) WALL TYPE SHOWN ON ITEM 9(A) DOESN'T MATCH
 ARCHITECTURAL PLANS. REVISE AS REQUIRED.
 NOTE:SEE NEW ADDITION AND GARAGEGUEST ROOM AREA.
  
 F) ENGINEER TO PROVIDE HIS INFORMATION AS REQUIRED
 BY CHAPTER 471 FLORIDA STATUTES AND SEC. 61G15-23.002
 FLORIDA ADMINISTRATIVE CODE.
  
 G) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 5- PROVIDE DETAILS/SPECIFICATIONS FOR ATTACHMENT OF
 STRUCTURAL BUCKS TO BE ATTACHED TO EXISTING AND NEW
 COLUMNS. INFORMATION ON SHEET A-10 DOESN'T PROVIDE THIS
 INFORMATION. (REPEAT COMMENT).
 ARCHITECT RESPONDED THAT THERE IS A DETAIL ON SHEET
 A-5. THERE ARE NOT BUCK DETAILS ON THIS SHEET.ALSO,
 STRUCTURAL PLANS DON'T ADDRESS THE ISSUE OFBUCK
 FASTENING TO THE COLUMNS. SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004 TO VERIFY COMPLIANCE WITH SEC. R301 AND
 R613.6.
  
 6- SOIL TEST REPORT:
 A) NEED TO PROVIDE REPORTS WITH ORIGINAL SEAL AND
 SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES
 AND SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE.
  
 7- SOIL TEST REPORT STATES SOIL BEARING CAPACITY OF
 2000PSF.STRUCTURAL PLANS REQUIRE 2500PSF SOIL BEARING
 CAPACITY.STRUCTURAL ENGINEER AND GEO-TECHNICAL
 ENGINEER TO COORDINATE INFORMATION AS REQUIRED.
  
 8- BRING ALL REVISED DRAWINGS FOR HISTORIC REVIEW AND
 APPROVAL PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 9- OWES $4.14 FOR NEW ADDITION RADON FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-01-04 Cont ID  
Sent By jgomez Date 2008-01-04 Time 16:58 Rev Time 0.00
Received By jgomez Date 2008-01-04 Time 16:58 Sent To PC
Notes
2008-01-04 16:59:50RESIDENTIALADDITION AND RENOVATION, BUILDING REVIEW
 SECOND CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1-NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.THIS MAY ME RECORDED AT TIME OF
 PERMIT PICK UP.
  
 2-BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF
 IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE. (REPEAT COMMENT).
  
 3- MISSING DRAWINGS A-2 THRU A-4.ALSO, SET OF PLANS
 SUBMITTED THE FIRST TIME HAD MORETHAN 8 ARCHITECTURAL
 PLANS.PROVIDE 2 COMPLETE SET OF PLANS.
  
 4- PROVIDE PRODUCT APPROVALAS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) FRENCH DOORS "INSWING " AND "OUTSWING" AS SHOWN
 ON PLANS. ALSO, FRENCH DOORS WITH SIDELITES AND TRANSOM
 ABOVE AS SHOWN ON PLANS. (REPEAT COMMENT).FLORIDA
 PRODUCT APPROVAL FL6573 SUBMITTED IS MISSING THE DOORS
 DRAWINGS. PROVIDE COMPLETE PRODUCT APPROVAL INFORMATION
 AND MAKE SURE DOORS INCLUDE THE TYPE OF DOORS SHOWN ON
 PLANS.
  
 B) ARCHED AND RECTANGULAR CASEMENT WINDOWS AS SHOWN
 ON PLANS. (REPEAT COMMENT).FLORIDA PRODUCT APPROVAL
 FL6496 SUBMITTED IS MISSING THE WINDOW DRAWINGS.
 PROVIDE COMPLETEPRODUCT APPROVAL INFORMATION AND MAKE
 SURE WINDOWS INCLUDE THE ONES SHOWN ON PLANS.
  
 C) FIXED WINDOWS,INCLUDING THE ARCHED WINDOWS AS
 SHOWN ON PLANS. (REPEAT COMMENT).
  
 D) WINDOW MULLIONS. AND CLEARLYMARK MULLION SIZE
 ANDATTACHMENT TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER. (REPEAT
 COMMENT).
  
 E) FLAT ROOF.CLEARLY MARKBASE SHEET FASTENING
 OPTION TO BE USEDON PAGE 18 OF NOA 03-0501.05
 SUBMITTED AND PROVIDE RAS 117 CALCULATIONS FOR NAIL
 ENHANCING AT PERIMETER AND CORNER AREAS AS REQUIRED BY
 GENERAL LIMITATION #7. (REPEAT COMMENT).
  
 F)GARAGE DOORS.PROVIDE PRODUCT APPROVAL FOR DOOR
 SIZE AS SHOWN ON PLANS. NOA 06-0331.04 SUBMITTED IS FOR
 14'-2"WIDE DOORS.
  
 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-600.0 FBC 2004. (REPEAT COMMENT). AND MAKE SURE
 CORRECTREVISED FORM IS USED.
  
 7-A) PROVIDE COMPLETE ICYNENE SPECIFICATIONS TO
 VERIFY COMPLIANCE WITHSEC.R314 OF 2004 FLORIDA
 RESIDENTIAL CODE.AND TO CHECK FOR REQUIRED THICKNESS
 TO ACHIEVE SPECIFIED R-VALUES.SEE ENERGY
 CALCULATIONS AND PLANS. (REPEAT COMMENT).
  
 B) PROVIDE DETAIL/SPECS SHOWING HOW TO ACCOMPLISH
 THE R-12 INSULATION WITH ICYNENE INSULATION ON EXISTING
 WALLS.SEEICYNENE SPECIFICATIONS FOR REQUIRED
 THICKNESS.
  
 8- ARCHITECT TO SPECIFY CONSTRUCTION TYPE.INFORMATION
 SUBMITTED IS INCOMPLETE. NEED TO SPECIFY IF
 CONSTRUCTION TYPE V IS A OR B AS REQUIRED BY SEC. 602.1
 FBC 2004.
  
 9- REVISE DIMENSIONS GIVEN FOR NEW STEPSTO COMPLY
 WITH SEC. R311.5.3 OF 2004 FLORIDA RESIDENTIAL CODE.
 GIVEN DIMENSIONS DON'T COMPLY.
  
 10-DESIGNER OF RECORD TO SPECIFY ROOF TILE ATTACHMENT
 AS REQUIRED BY SEC. 106.1.1.2 OF CITY AMENDMENTS TO FBC
 2004.IF USING POLY FOAM, THEN PROVIDE PRODUCT
 APPROVAL. (REPEAT COMMENT).SEE ROOF TILE NOA FOR
 LISTED POLYFOAM TO BE USED.
  
 11-MISSING SHEET A-10. UNABLE TO CHECK IF
 DETAILS/SPECIFICATIONS FORSTRUCTURAL BUCK TO BE
 ATTACHED TO EXISTING AND NEW COLUMNSWERE PROVIDED.
 THIS WAS REQUESTED ON PREVIOUS CHECKLIST. STRUCTURAL
 PLANS DON'T PROVIDE THIS INFORMATION EITHER.
  
 12- SHEET S4:UPDATE REFERENCE STANDARDS. SEE CHAPTER
 43 OF 2004 FLORIDA RESIDENTIAL CODE FOR CORRECT YEAR
 THAT WAS ADOPTED BY THE2004 CODE. (REPEAT COMMENT).
  
 13- PROVIDE SOIL TEST REPORT.SEC. R401.4 OF 2004
 FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT).
  
 14- SHEET S5: REVISE DIMENSIONS GIVEN ON TYPICAL STEP
 FOOTING DETAIL.COORDINATE WITH REVISED DIMENSIONS ON
 ARCHITECTURAL PLAN.STEPS CAN'T HAVE 8" TREADS AND
 RISERS. (REPEAT COMMENT).
  
 15- ARCHITECT TO DATE WHEN SEALING THE PLANS AS
 REQUIRED BY SEC. 61G-16.004 OF FLORIDA ADMINISTRATIVE
 CODE.
  
 16- DRAWINGS ARE MISSING THE DOOR AND WINDOW
 SCHEDULES.
  
 17- BRINGREVISED PLANS TO THECITY HALL 5TH FLOOR
 FOR HISTORICAL APPROVAL AND STAMP PRIOR TO SUBMITTAL TO
 THIS OFFICE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-24 Cont ID  
Sent By jgomez Date 2007-08-24 Time 16:58 Rev Time 0.00
Received By jgomez Date 2007-08-24 Time 16:58 Sent To PC
Notes
2007-08-24 17:00:19RESIDENTIALADDITION AND RENOVATION BUILDING REVIEW
 FIRST CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC 2004
 WITH 2006/2007 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5115)TO VERIFY IF IMPACT FEES ARE DUE. BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF IMPACT
 FEES ARE DUE.
  
 3- PROVIDE PRODUCT APPROVALS FOR:
 A) FRENCH DOORS "INSWING AND OUTSWING" AS SHOWN ON
 PLANS. INCLUDING FRENCH DOORS WITH SIDELITES
 ASSEMBLIES.
  
 B) ARCHED AND RECTANGULAR CASEMENT WINDOWS AS SHOWN
 ON EXTERIOR ELEVATIONS.
  
 C) FIXED WINDOWS AS SHOWN ON PLANS.
  
 D) FRENCH DOORS WITH TRANSOMABOVE AS SHOWN ON
 EXTERIOR ELEVATIONS.
  
 E) WINDOW MULLION. AND, CLEARLY INDICATE MULLION
 SIZE AND ATTACHMENT TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES CALCULATED BY THE ENGINEER.
  
 F) FLAT ROOF.AND,CLEARLY IDENTIFY SPECIFIC
 ASSEMBLY TO BE INSTALLED.ALSO, IF SELECTED ASSEMBLY
 IS LIMITED BY GENERALLIMITATION #7, THEN PROVIDE RAS
 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND
 CORNER AREAS. SEE GENERAL LIMITATION #7 ON LAST PAGE OF
 NOA. IF THIS LIMITATION REQUIRES CALCULATIONS TO BE
 DONE BY ANY OF THE LISTED PROFESSIONALS, THEN
 CALCULATIONSMUST BE DONE BY ANY ONE OF THEM.
 IF-SELECTED ASSEMBLY IS LIMITED BY GENERAL LIMITATION
 #9, THEN IT CAN'T BE USED IN THIS AREA.
  
 G) ROOF TILE.
  
 H) GARAGE DOORS.
  
 I) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND SPECIFIC SHEET WHERE CONNECTOR IS SHOWN TO
 SAVE PAPER.
  
 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 5- ONLY TWO SETS OF PLANS AND PRODUCT APPROVALS ARE
 REQUIRED. NOT THREE.
  
 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-600.0 OF FBC 2004.
  
 7 PROVIDE COMPLETE ICYNENE SPECIFICATIONS. SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004.
  
 8- PLANS TO SPECIFY CONSTRUCTION TYPE AS REQUIRED BY
 SEC. 602.1 FBC 2004.
  
 9- PROVIDE COMPLETE DIMENSIONSFOR NEW STEPS TO VERIFY
 COMPLIANCE WITH SEC. R311.5.3 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 10- DESIGNER OF RECORD TO SPECIFY ROOF TILE ATTACHMENT
 AS REQUIRED BY SEC. 106.1.1.2 OF CITY AMENDMENTS TO FBC
 2004.IF USING NAILS OR SCREWS, THEN SPECIFY SIZE AND
 NUMBER TO BE USED. IF USING ADHESIVE, THEN SPECIFY
 WHICH ONE AND PROVIDE PRODUCT APPROVAL AS REQUIRED BY
 DCA RULE 9B-72.
  
 11- SHEET A10: PROVIDE COMPLETE SPECIFICATIONS FOR
 ATTACHMENT OF STRUCTURAL BUCKS TO EXISTING AND NEW
 COLUMNS. STRUCTURAL PLANS DON'T PROVIDE THIS
 INFORMATION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 12- SHEET S4:
 A) UPDATEREFERENCE STANDARDS SPECIFIED ALL GENERAL
 NOTES. SEECHAPTER 43 OF 2004 FLORIDA RESIDENTIAL CODE
 AND CHAPTER 35 OF FBC 2004 FOR CORRECTREFERENCE
 STANDARDS AND YEAR ADOPTED BY THE CODE AND REVISE ALL
 NOTES AS REQUIRED.
  
 B) PROVIDE SOIL TEST REPORT REFERENCED ON FOUNDATION
 NOTE #1.
  
 C) SPECIFY CONNECTOR AT TOP OF STEEL COLUMN SC-1.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 D) PLYWOOD ROOF SHEATHING THICKNESS SPECIFIED ON
 WOOD NOTE 5(A) DOESN'T MATCH THICKNESSSPECIFIED ON
 DETAILS SHOWN ON SHEET S6. REVISE AS REQUIRED TO
 MATCH.
  
 E) REVISE SECTION SPECIFIED ON NOTE #1 BELOW THE
 WIND LOAD SCHEDULE CHART. SEE FBC 2004 FOR CORRECT
 SECTION TO BE CITED.
  
 13- SHEET S5:
 A) REVISE DIMENSION SHOWN ON TYPICAL STEP FOOTING
 DETAIL. SEE ITEMCOMMENTS ON ITEM #9 ABOVE.
  
 B) REVISE NOTE #1 BELOW TYPICAL WOOD BUCK TO
 CONCRETE CONNECTION DETAIL. REVISE FBC 2001 AND SECTION
 CITED FOR OPENING PROTECTION. SEE FBC 2004 FOR CORRECT
 SECTION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-04-14 Cont ID  
Sent By btrobaug Date 2008-04-14 Time 08:19 Rev Time 0.00
Received By btrobaug Date 2008-04-11 Time 14:32 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-03-13 Cont ID  
Sent By btrobaug Date 2008-03-13 Time 11:56 Rev Time 0.00
Received By btrobaug Date 2008-03-12 Time 07:03 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-12-27 Cont ID  
Sent By btrobaug Date 2007-12-27 Time 08:55 Rev Time 0.00
Received By btrobaug Date 2007-12-26 Time 16:40 Sent To M
Notes
2007-12-27 08:55:04 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} DUE TO THE METER LOCATION, A DISCONNECT IS REQUIRED
 PER225.32 AT THE MAIN HOUSE. SEE "IMMEDIATE POINT OF
 ENTRANCE" IN THAT ARTICLE. INDICATE LOCATION ON PLAN
 PER 230.72(A)(1)
  
 2} THE DINING ROOM ADDITION MUST COMPLY WITH 210.52
 RCEPTACLE SPACING REQUIREMENTS. LOCATE ON PLANS. NOTE:
 IN A DINING ROOM A SMALL APPLIANCE CIRCUIT IS REQUIRED
 PER 210.52(B)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-20 Cont ID  
Sent By btrobaug Date 2007-08-20 Time 08:44 Rev Time 0.00
Received By btrobaug Date 2007-08-20 Time 06:22 Sent To P
Notes
2007-08-20 08:15:57 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
  
 1} PLEASE PROVIDE A PANEL SCHEDULE SO THAT
 BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT
 PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC
 AS AMENDED. SEE PANEL "A" AND PANEL "C", SHEET E-3, ARE
 INCOMPLETE. NOTE IF ALL SERVICE EQUIPMENT ON THE RISER
 AND PLANS ARE BEING INSTALLED UNDER THIS PERMIT, OR
 WHICH MAY BE EXISTING.
  
 2} AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED
 FROM THE FIRST MEANS OF DISCONNECT TO THE PANEL PER
 250.118, SIZED PER 250.122. NONE IS SHOWN WITH THE
 FEEDER FROM THE 225 AMP MAIN TO PANEL "A".
  
 3}PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT
 SIZE AND TYPE, INCLUDING THE GUTTER CONDUCTORS, NIPPLES
 AND CONDUCTORS FEEDING OUT OF THE GUTTER. PANEL "C" IS
 NOTED ON THE PANEL SCHEDULE WHICH IS SUFFICIENT.
  
 4} IN THE ELECTRICAL SPECIFICATIONS, SHEET E-3, NUMBER
 3 C, INDICATES NO CONDUCTORS LARGER THAN THAN #8 MAY BE
 SPLICED. THE 250 MCM ASSUMED TO BE IN THE GUTTER MUST
 BE TAPPED. PLEASE CHECK ALL NOTES FOR RELEVANCE TO THIS
 PROJECT AND REMOVE THE ONES THAT AREN'T, AND CLARIFY
 THE ONES THAT ARE. ALSO SEE THE NOTE ABOUT NO ROMEX
 BEING ALLOWED, (2D). IF NOTES ARE PART OF THE
 CONSTRUCTION DOCUMENTS THEY WILL BE REGARDED AS
 INSTALLATION INSTRUCTIONS BY THE DESIGNER AND MUST BE
 ADHERED TO. ANY FIELD CHANGES WILL NEED TO BE REVISED
 ON THE PLAN AND RESUBMITTED FOR REVIEW.
  
 5} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN
 INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS
 SHALL BE INTERCONNECTED AND HARD WIRED. LOCATE THESE
 ALARMS ON THE PLAN.
  
 6} 210.52(C)(2) ISLAND COUNTER SPACES AT LEAST ONE
 RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER
 SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR
 GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR
 GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN
 ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE
 RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE
 RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND
 INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN
 210.52(C)(4). NONE ARE SHOWN FOR THE NEW KITCHEN
 ISLAND. LOCATE ON THE PLAN.
  
 FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE
 FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE INDICATE
 THE CODE CYCLES UNDER WHICH THIS PLAN WAS DESIGNED.
 ELECTRICAL SPECIFICATIONS, GENERAL SPECIFICATIONS "D",
 IS VAGUE, AND IN NO WAY INDICATES THE CODES BEING
 REFERRED TO.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-07-31 Cont ID  
Sent By ssherman Date 2007-07-31 Time 12:14 Rev Time 0.00
Received By ssherman Date 2007-07-31 Time 12:13 Sent To  
Notes
2007-07-31 12:14:08HISTORICAL APPROVAL PER FREDERIKE MITTNER

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-05-14 Cont ID  
Sent By adarroug Date 2008-05-14 Time 10:47 Rev Time 0.00
Received By adarroug Date 2008-05-14 Time 10:47 Sent To B
Notes
2008-05-14 10:48:28TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-04-10 Cont ID  
Sent By adarroug Date 2008-04-10 Time 12:30 Rev Time 0.00
Received By adarroug Date 2008-04-10 Time 12:30 Sent To Z
Notes
2008-04-10 12:30:33TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-03-10 Cont ID  
Sent By adarroug Date 2008-03-10 Time 11:49 Rev Time 0.00
Received By adarroug Date 2008-03-10 Time 11:49 Sent To Z
Notes
2008-03-10 11:49:43TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-12-20 Cont ID  
Sent By mmiller Date 2007-12-20 Time 17:29 Rev Time 0.00
Received By mmiller Date 2007-12-20 Time 17:29 Sent To  
Notes
2007-12-20 17:30:08SENT TO ZONING INBOX MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-24 Cont ID  
Sent By jgomez Date 2007-08-24 Time 16:58 Rev Time 0.00
Received By jgomez Date 2007-08-02 Time 15:40 Sent To  
Notes
2007-08-02 15:40:43TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-04-23 Cont ID  
Sent By tgordon Date 2008-04-23 Time 11:25 Rev Time 0.30
Received By tgordon Date 2008-04-23 Time 11:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2008-03-14 Cont ID  
Sent By btrobaug Date 2008-04-14 Time 09:00 Rev Time 1.00
Received By tgordon Date 2008-03-14 Time 14:35 Sent To B
Notes
2008-03-14 15:09:09PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R,
 PER 2004 FBC 13-600.3.A, (12-8-06 REVISION).
  
 2) WHEN RESUBMITTING ENERGY CALCULATIONS HAVE THEM
 SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC 13-103.3.
  
 3) PLEASE SUBMIT THE COMPLETE COOLING LOAD CALCULATIONS
 FOR EACH ZONE NOT JUST ONE PAGE FOR THE WHOLE HOUSE,
 PER 2004 FBC 13-607.1.ABC.1.
  
 4) SEE PLAN M-3 RTU MOUNTING DETAIL, STATES 'SEE F.B.C.
 CHAPTER-16 TABLE 1606.1.4 FOR SIZE AND ETC.'. THE 2004
 FBC HAS NO TABLE 1606.1.4 IN CHAPTER 16 PLEASE REMOVE
 FROM PLAN AND PROVIDE AN ENGINEERED DETAIL FOR SECURING
 THE RTU'S TO WITHSTAND WIND LOADS UP TO 140 MPH, PER
 2004 FBC 1609 AND FBC/R M1307.3.
  
 5) PLEASE ADD A NOTE TO THE MECHANICAL PLANS. THE
 MANUFACTURER'S SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS WILL BE ON THE JOB FOR THE INSPECTOR
 SHOWING THE RTU'S ARE DESIGNED TOWITH-STANDING WIND
 LOADS UP TO 140 MPH PER 2004 FBC 1609, OR YOU MAY
 SUBMIT THE MANUFACTURER'S SPEC'S. NOW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-12-27 Cont ID  
Sent By tgordon Date 2007-12-27 Time 10:45 Rev Time 0.35
Received By tgordon Date 2007-12-27 Time 10:45 Sent To P
Notes
2007-12-27 10:49:44PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, AND CHAPTER 1
 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** DENIED ***
 1) AS REQUESTED IN LAST REVIEW 8-14-07.PLEASE SUBMIT
 ENERGY CALCULATIONS, SEE 2004 FBC 13-101.2.3.
  
 2) AS REQUESTED IN LAST REVIEW 8-14-07. PLEASE SUBMIT
 COOLING LOAD CALCULATIONS, SEE 2004 FBC
 13-607.1.ABC.1.
  
 3) MECHANICAL PLAN FOR FIRST FLOOR PAGE M-1 IS MISSING
 FROM SUBMITTED PLANS, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-14 Cont ID  
Sent By tgordon Date 2007-08-14 Time 07:57 Rev Time 0.30
Received By tgordon Date 2007-08-14 Time 07:57 Sent To E
Notes
2007-08-14 08:08:36PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER
 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC
 13-101.2.3.
  
 2) PLEASE SUBMIT COOLING LOAD CALCULATIONS, SEE 2004
 FBC 13-607.1.ABC.1.
  
 3) SHOW ON MECHANICAL PLANS PAGE M-2 HOW RETURN AIR IS
 BEING PROVIDED FOR TO AC-1, SEE 2004 FBC/R M1602.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-04-14 Cont ID  
Sent By mperson Date 2008-04-14 Time 16:28 Rev Time 0.00
Received By mperson Date 2008-04-14 Time 16:28 Sent To B
Notes
2008-04-14 16:30:50NOTE: NEW P-1 SHEET. PER TOM GORDONS INSTRUCTIONS PLANS
 ROUTED TO BLDG., MECHANICAL TO REVIEW LAST.
  
 ****************PROVISO****************
 THE FIXTUES IN THE POWDER ROOM SHALL CONFORM TO THE
 FOLLOWING.
 P2705.1 GENERAL. (FBC PLUMBING RESIDENTIAL)
 THE INSTALLATION OF FIXTURES SHALL CONFORM TO THE
 FOLLOWING:
 5.THE CENTERLINE OF WATER CLOSETS OR BIDETS SHALL
 NOT BE LESS THAN 15 INCHES (381 MM) FROM ADJACENT WALLS
 OR PARTITIONS OR NOT LESS THAN 15 INCHES (381 MM) FROM
 CENTERLINE OF A BIDET TO THE OUTERMOST RIM OF AN
 ADJACENT WATER CLOSET. THERE SHALL BE AT LEAST 21
 INCHES (533 MM) CLEARANCE IN FRONT OF THE WATER CLOSET,
 BIDET OR LAVATORY TO ANY WALL, FIXTURE OR DOOR.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-03-14 Cont ID  
Sent By mperson Date 2008-03-14 Time 11:45 Rev Time 0.00
Received By mperson Date 2008-03-14 Time 11:45 Sent To M
Notes
2008-03-14 11:53:28****************PROVISO****************
 THE FIXTUES IN THE POWDER ROOM SHALL CONFORM TO THE
 FOLLOWING.
 P2705.1 GENERAL. (FBC PLUMBING RESIDENTIAL)
 THE INSTALLATION OF FIXTURES SHALL CONFORM TO THE
 FOLLOWING:
 5.THE CENTERLINE OF WATER CLOSETS OR BIDETS SHALL
 NOT BE LESS THAN 15 INCHES (381 MM) FROM ADJACENT WALLS
 OR PARTITIONS OR NOT LESS THAN 15 INCHES (381 MM) FROM
 CENTERLINE OF A BIDET TO THE OUTERMOST RIM OF AN
 ADJACENT WATER CLOSET. THERE SHALL BE AT LEAST 21
 INCHES (533 MM) CLEARANCE IN FRONT OF THE WATER CLOSET,
 BIDET OR LAVATORY TO ANY WALL, FIXTURE OR DOOR.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-12-28 Cont ID  
Sent By mperson Date 2007-12-28 Time 11:33 Rev Time 0.00
Received By mperson Date 2007-12-28 Time 11:33 Sent To B
Notes
2007-12-28 13:12:20PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED 2ND TIME:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE STILL
 REQUIRED FOR PLUMBING PLAN REVIEW TO MEET CODE
 COMPLIANCE.
 **NOTE: THERE WAS NOT A TRANSMITTAL LETTER ADDRESSING
 PREVIOUS PLUMBING PLAN REVIEW COMMENTS.
  
 **PREVIOUS REVIEW COMMENTS**
  
 1. OK
  
 2. **COMMENT NOT ADDRESSED**
 SHEET P-1: SPECIFY HOW THE ELECTRIC WATER HEATER IN THE
 GARAGE WILL BE PROTECTED FROM MECHANICAL DAMAGE AS
 REQUIRED BY FBC, 2004 MECHANICAL, SECTION 303.4.
 **SHEET P-1 REVIEW COMMENT REV. #1 INDICATES SEE SHEET
 P-3 WATER HEATER DETAIL, HOWEVER SHEET P-3 WATER HEATER
 DETAIL ONLY INDICATES TOP OF TANK AT 92". THERE IS NO
 INDICATION ON HOW WATER HEATER IS BEING PROTECTED.
 PLEASE COMPLY.
  
 3. OK
  
 4. OK
  
 5. **COMMENT NOT ADDRESSED**
 SHEET P-2 SANITARY RISER S-2: THE WASHING MACHINE
 BRANCH DRAIN AND DRAINAGE STACK ARE SIZED WRONG. PER
 *406.3 MINIMUM THREE INCH (3") REQUIRED.
 **NOTE: PER *102.1 GENERAL. WHERE, IN ANYSPECIFIC
 CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT
 MATERIALS, METHODS OF CONSTRUCTION OR OTHER
 REQUIREMENTS, THE MOST RESTRITIVE SHALL GOVERN.
  
 6. OK
  
 7. A} OK AND B} OK
  
 8. OK
  
 **THE FOLLOWING ARE NEW COMMENTS**
  
 9. SHEET A-1 GUEST ROOM INDICATES A NEW SHOWER AND
 SHEETS P-1 AND P-3 ARE INDICATING TUBS. PLEASE
 CORRELATE THE PLANS ON THE RESUBMITTAL. PER *106.1.1,
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 10. SHEETS P-1, P-2, AND P-3 ONLY ONE SET OF THESE
 SHEETS ARE SIGNED AND SEALED BY ENGINEER OF RECORD
 MICHAEL A. TEELE, P. E. #32066. PER *106.1, SUBMITTAL
 DOCUMENTS TWO COMPLETE SETS ARE REQUIRED AND THEY SHALL
 BE SIGNED AND SEALED PER *CHAPTER 471, FLORIDA
 STATUTES.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-21 Cont ID  
Sent By btrobaug Date 2007-12-27 Time 12:03 Rev Time 0.00
Received By mperson Date 2007-08-21 Time 16:43 Sent To B
Notes
2007-08-21 17:00:40DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET P-1: CLEARLY INDICATE THE WATER HEATER SIZE
 IN THE GARAGE AND CLARIFY IF THE WORDING FOR THE GARAGE
 WATER HEATER IS SUPPOSED TO BE"WATER HEATER FOR GUEST
 RM BATH OR GUEST HOUSE."
  
 2. SHEET P-1: SPECIFY HOW THE ELECRIC WATER HEATER IN
 THE GARAGE WILL BE PROTECTED FROM MECHANICAL DAMAGE AS
 REQUIRED BY FBC-2004 MECHANICAL, SECTION 303.4.
  
 3. SHEET P-2: CLEARLY INDICATE THE WATER HEATER SIZE
 IN THE A/C CLOSET AND PER FBC-2004 PLUMBING, SECTION
 504.7 WHERE A WATER HEATER IS INSTALLED ABOVE THE
 GROUND FLOOR THE WATER HEATER SHALL BE INSTALLED IN A
 PAN..
  
 4. SHEET P-2 ELECTRIC WATER HEATER DETAIL: INDICATE
 THERMAL EXPANSION CONTROL PER FBC-2004 PLUMBING
 SECTION, 607.3. (SHEET A-1 IS INDICATING AN EXISTING
 SWIMMING POOL WHICH MEANS A RPZV BACKFLOW PREVENTER IS
 ON POTABLE WATER SERVICE)
  
 5. SHEET P-2 SANITARY RISER S-2: THE WASHING MACHINE
 BRANCH DRAIN OR DRAINAGE STACK IS SIZED WRONG A MINIMUM
 OF 3 INCH IS REQUIRED PER FPC-2004 PLUMBING, SECTION
 406.3.
  
 6. SHEET P-2 SANITARY RISER DIAGRAM: CLEARLY INDICATE
 WHERE THE 1ST FLOOR VENTING FROM BELOW IS LOCATED AND
 WHERE IT TIES INTO THE 2ND FLOOR VENT THRU ROOF
 (V.T.R.) PER FBC-2004 PLUMBING, SECTION 903.3.
  
 7. SHEET P-3 ELECTRIC WATER HEATER SCHEMATIC:
  
 A} INDICATE THERMAL EXPANSION CONTROL PER FBC-2004
 PLUMBING, SECTION 607.3.(SHEET A-1 IS INDICATING AN
 EXISTING SWIMMING POOL WHICH MEANS A RPZV BACFLOW
 PREVENTER IS ON THE POTABLE WATER SERVICE)
  
 B} PER FBC-2004 PLUMBING, SECTION 606.1 A FULL- OPEN
 VALVE SHALL BE INSTALLED ON THE WATER SUPPLY PIPE TO
 THE WATER HEATER.
  
 8. SHEET P-3 SANITARY RISER DIAGRAM: CLEARLY INDICATE
 WHERE THE VENT IS GOING UP TO THE 2ND FLOOR VENT SYSTEM
 FROM THE 1ST FLOOR VENTS PER FBC-2004 PLUMBING, SECTION
 903.3.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK ON
 THE INDICATED PLAN SHEETS BY THIS PLAN EXAMINER FOR
 REFERENCE FOR THE RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 4 Status P Date 2008-04-11 Cont ID  
Sent By choops Date 2008-04-11 Time 08:44 Rev Time 0.00
Received By choops Date 2008-04-11 Time 08:44 Sent To E
Notes
2008-04-11 08:47:24***APPROVED - RESUB #3***
  
 PROVISOS:
 1)DECORATIVE ELEMENTS OF THE FRONT GARDEN WALL SHALL
 NOT EXCEED 4 FEET 4 INCHES IN HEIGHT (4' ALLOWABLE,
 PLUS 10% FOR DECORATIVE ELEMENTS), MEASURED FROM
 GRADE.
 2)PROPOSED OUTDOOR SHOWER SHALL BE SETBACK A MINIMUM
 OF 5 FEET FROM THE REAR PROPERTY LINE AND SHALL NOT
 ENCROACH THE REAR UTILITY EASEMENT.
  
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 3 Status F Date 2008-03-11 Cont ID  
Sent By choops Date 2008-03-11 Time 08:48 Rev Time 0.00
Received By choops Date 2008-03-11 Time 08:48 Sent To E
Notes
2008-03-11 08:58:18***FAILED - RESUB #2***
  
  
 NEW COMMENTS:
  
 1)PLANS INCONSISTENT.A/C AND POOL EQUIPMENT
 LOCATION DO NOT MATCH BETWEEN SITE PLAN (A-1) AND MEP
 PLANS (P-1, M-1, E-1).WHERE IS THE EQUIPMENT TO BE
 LOCATED?THE EQUIPMENT DOES NOT MEET SETBACK
 REQUIREMENTS AS SHOWN ON MEP'S, ADDITIONALLY, THE
 EQUIPMENT SHALL NOT BE PERMITTED WITHIN THE REAR
 UTILITY EASEMENT OF 5'.PLEASE REVISE PLANS TO BE
 CONSISTENT AND TO SHOW THE EQUIPMENT WITHIN THE
 REGULATIONS SET FORTH IN SECTION 94-305 OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS.
  
  
 NOTE:DECORATIVE ELEMENTS OF THE FRONT GARDEN WALL
 SHALL NOT EXCEED 4 FEET 4 INCHES IN HEIGHT, MEASURED
 FROM GRADE.
  
 NOTE:PROPOSED OUTDOOR SHOWER SHALL BE SETBACK A
 MINIMUM OF 5 FEET FROM THE REAR PROPERTY LINE AND SHALL
 NOT ENCROACH THE REAR UTILITY EASEMENT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 2 Status F Date 2007-12-24 Cont ID  
Sent By choops Date 2007-12-24 Time 14:36 Rev Time 0.00
Received By choops Date 2007-12-24 Time 14:36 Sent To E
Notes
2007-12-24 14:44:21***FAILED***
  
  
 REPEAT COMMENTS:
  
 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK WITH SETBACK DIMENSIONS TO
 THE PROPERTY LINES.
  
 2)THE PROPOSED GARDEN WALLS WILL REQUIRE AN APPROVED
 EASEMENT CONSENT FORM FROM THE CITY OF WEST PALM BEACH
 DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY HALL)
  
 NEW COMMENTS:
  
 1)INDICATE SETBACK DIMENSIONS FROM
 PROPOSED/RELOCATED POOL EQUIPMENT AND A/C EQUIPMENT TO
 THE PROPERTY LINES.AS PER SECTION 94-305(B)(4) OF THE
 ZLDRS: MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN
 4' INTO A REQUIRED SETBACK.
  
 2)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE,
 LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE
 SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION
 94-442 AND 94-445 OF THE ZLDRS.
  
 3)PLANS SHALL BE RESTAMPED BY HISTORIC PRESERVATION
 AND/OR ORIGINAL APPROVAL LETTER FROM HISTORIC
 PRESERVATION SHALL BE SUBMITTED ALONG WITH PERMIT
 APPLICATION PACKET.
  
  
 ***NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION
 MAY GENERATE ADDITIONAL COMMENTS.*** ***NEW COMMENTS
 ARE LIKELY TO ARISE UNTIL ALL REQUESTED INFORMATION IS
 SUBMITTED.***
  
 NOTE:IT IS HELPFUL TO HAVE ALL SUBMITTED PLANS
 ORGANIZED INTO TWO (2) DISTINCT PACKETS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2007-08-06 Cont ID  
Sent By choops Date 2007-08-06 Time 14:18 Rev Time 0.00
Received By choops Date 2007-08-06 Time 14:18 Sent To E
Notes
2007-08-06 14:23:41***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK WITH SETBACK DIMENSIONS TO
 THE PROPERTY LINES.
  
 2)AS YOU ARE PROPOSING A GARDEN WALL, PROVIDE AN
 EASEMENT CONSENT FORM FROM THE CITY OF WEST PALM BEACH
 DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY HALL)
  
 3)PROVIDE ELEVATION DIMENSIONS FROM GRADE TO THE
 MIDPOINT OF THE ROOF'S PITCH (OF THE ADDITION).
  
 4)INDICATE ROOF OVERHANG DIMENSIONS.
  
 5)PROVIDE AN ELEVATION AND DIMENSIONS OF TERRACE AND
 STEPS.
  
 NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720