| Plan Review Stops For Permit 07071040 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-05-16 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-05-16 |
Time |
13:12 |
Sent To |
PC |
|
| Notes |
| 2008-05-16 13:19:58 | PROVISO ITEMS: REVISED ENERGY CALCULATIONS AND REVISED | | | RAS 117 CALCULATIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-22 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-22 |
Time |
07:37 |
Sent To |
M |
|
| Notes |
| 2008-04-23 10:43:16 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- FLAT ROOF SYSTEM: REVISE DESIGN PRESSURES SHOWN ON | | | THE RAS 117 CALCULATIONS. SEESTRUCTURAL DRAWING S-4 | | | FOR CORRECT DESIGN PRESSURES CALCULATED BY THE ENGINEER | | | FOR FLAT ROOF AND REVISE AS REQUIRED.THEN, RE-RUN THE | | | RAS 117 CALCULATIONS AND REVISE ANCHOR SPACING AS | | | REQUIRED. | | | | | | 2- REVISE ENERGY CALCULATIONS: | | | A) WALL TYPES ON ITEM #9 NEED TO INCLUDE THE WALL | | | TYPES SHOWN FOR NEW ADDITION AND FOR GARAGE AREA.SEE | | | PLANS AND REVISE AS REQUIRED. | | | | | | NOTE: | | | PROVIDEREVISED INFORMATION AS SOON AS POSSIBLE TO | | | AVOID ANY UNNECESSARY DELAYS OR CONFLICTS DURING | | | INSPECTION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-03-18 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-03-18 |
Time |
16:37 |
Sent To |
PC |
|
| Notes |
| 2008-03-18 17:02:11 | RESIDENTIAL ADDITION AND RENOVATIONS, BUILDING REVIEW | | | THIRD CHECKLIST. | | | REVIEW UNDER 2004 FBC WITH 2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | | | 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) FLAT ROOF: NEED TO PROVIDE THE RAS 117 | | | CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER | | | AREAS AS REQUIRED BY GENERAL LIMITATION #7.(REPEAT | | | COMMENT).INFORMATION SUBMITTED ON SHEET A-2 IS THE | | | EXACT SAME INFORMATION THAT IS PROVIDED IN THE FLAT | | | ROOF NOA 03-0501.05. | | | | | | ***NOTE: COMPONENTS AND CLADDING LOADS SPECIFIED IN THE | | | STRUCTURAL DRAWINGS NEED TO BE REVISED ACCORDING TO | | | TABLE R301.2(3),FIGURE R301.2(8) OF 2004 FLORIDA | | | RESIDENTIALCODE AND THE DEFINITION FOR "EFFECTIVE | | | WIND AREA"IN THE FBC 2004 SEC. 1609.2. | | | | | | ALSO, MINIMUM DIMENSION FOR ZONE "A" IS 4'-0" AS | | | REQUIRED BY FIGURE R301.2(8). REVISE AS REQUIRED. | | | | | | B) FIXED WINDOWS. (REPEAT COMMENT). PRODUCT APPROVAL | | | SUBMITTED FOR FRENCH DOORS DOESN'T HAVE THE INFORMATION | | | FOR TRANSOM WINDOWS ABOVE DOORS. | | | | | | C) WINDOW/ DOORS MULLIONS. (REPEAT COMMENT). PRODUCT | | | APPROVAL FOR FRENCH DOORS DOESN'T HAVE THE INFORMATION | | | FOR MULLIONS. NEED TO PROVIDE SEPARATE PRODUCT | | | APPROVAL. SEE GENERAL NOTES ON NOA SUBMITTED. | | | | | | ALSO, CLEARLY MARK MULLION SIZE AND ATTACHMENT TO | | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. (REPEAT | | | COMMENT). | | | | | | D) GARAGE DOOR SIZE AS SHOWN ON PLANS. (REPEAT | | | COMMENT). PRODUCT APPROVAL IS FORWIDE DOORS UP TO | | | 14'-2" .THERE ARE DIFFERENT PRODUCT APPROVALS FOR | | | NARROWER DOORS. TYPICALLY 8' AND 9' WIDE DOORS. PROVIDE | | | SUCH PRODUCT APPROVAL.. CONTACT MANUFACTURER FOR PROPER | | | PRODUCT APPROVAL. | | | | | | E) CLAY ROOF TILE.NO PRODUCT APPROVAL SUBMITTED | | | THIS TIME. | | | ***NOTE: HISTORIC DISTRICT REQUIRES CLAY TILE. SEE | | | THEIR COMMENTS IN THE APPROVED DRAWINGS. | | | NOA 06--0324.01 SPECIFIED BY ARCHITECT ON PRODUCT | | | APPROVAL REVIEW LIST IS FOR CONCRETE TILE. REVISE AS | | | REQUIRED. COORDINATE WITH HISTORIC PERSONNEL. | | | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS. SEC. 106.3.3 CITY AMENDMENTS TO | | | FBC 2004. | | | | | | 4- ENERGY CALCULATIONS: | | | A) PROVIDE CORRECT REVISED FORM. (REPEAT COMMENT). | | | NEED FORM 600A-2004R. | | | | | | B) COMPLETE INFORMATION ON TOP OF FORM. | | | | | | C)AREAS SHOWN ON ITEM 6 AND 10A) DON'T MATCH AREAS | | | SHOWN ON ARCHITECTURAL PLANS.REVISE AS REQUIRED. | | | | | | D) R VALUES SHOWN FOR WALLS AND CEILINGS DON'T MATCH | | | ARCHITECTURAL PLANS. REVISE AS REQUIRED. | | | | | | E) WALL TYPE SHOWN ON ITEM 9(A) DOESN'T MATCH | | | ARCHITECTURAL PLANS. REVISE AS REQUIRED. | | | NOTE:SEE NEW ADDITION AND GARAGEGUEST ROOM AREA. | | | | | | F) ENGINEER TO PROVIDE HIS INFORMATION AS REQUIRED | | | BY CHAPTER 471 FLORIDA STATUTES AND SEC. 61G15-23.002 | | | FLORIDA ADMINISTRATIVE CODE. | | | | | | G) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | | | 5- PROVIDE DETAILS/SPECIFICATIONS FOR ATTACHMENT OF | | | STRUCTURAL BUCKS TO BE ATTACHED TO EXISTING AND NEW | | | COLUMNS. INFORMATION ON SHEET A-10 DOESN'T PROVIDE THIS | | | INFORMATION. (REPEAT COMMENT). | | | ARCHITECT RESPONDED THAT THERE IS A DETAIL ON SHEET | | | A-5. THERE ARE NOT BUCK DETAILS ON THIS SHEET.ALSO, | | | STRUCTURAL PLANS DON'T ADDRESS THE ISSUE OFBUCK | | | FASTENING TO THE COLUMNS. SEC. 106.1.2 CITY AMENDMENTS | | | TO FBC 2004 TO VERIFY COMPLIANCE WITH SEC. R301 AND | | | R613.6. | | | | | | 6- SOIL TEST REPORT: | | | A) NEED TO PROVIDE REPORTS WITH ORIGINAL SEAL AND | | | SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES | | | AND SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE. | | | | | | 7- SOIL TEST REPORT STATES SOIL BEARING CAPACITY OF | | | 2000PSF.STRUCTURAL PLANS REQUIRE 2500PSF SOIL BEARING | | | CAPACITY.STRUCTURAL ENGINEER AND GEO-TECHNICAL | | | ENGINEER TO COORDINATE INFORMATION AS REQUIRED. | | | | | | 8- BRING ALL REVISED DRAWINGS FOR HISTORIC REVIEW AND | | | APPROVAL PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 9- OWES $4.14 FOR NEW ADDITION RADON FEES. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-01-04 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-01-04 |
Time |
16:58 |
Sent To |
PC |
|
| Notes |
| 2008-01-04 16:59:50 | RESIDENTIALADDITION AND RENOVATION, BUILDING REVIEW | | | SECOND CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1-NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE.THIS MAY ME RECORDED AT TIME OF | | | PERMIT PICK UP. | | | | | | 2-BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF | | | IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. (REPEAT COMMENT). | | | | | | 3- MISSING DRAWINGS A-2 THRU A-4.ALSO, SET OF PLANS | | | SUBMITTED THE FIRST TIME HAD MORETHAN 8 ARCHITECTURAL | | | PLANS.PROVIDE 2 COMPLETE SET OF PLANS. | | | | | | 4- PROVIDE PRODUCT APPROVALAS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) FRENCH DOORS "INSWING " AND "OUTSWING" AS SHOWN | | | ON PLANS. ALSO, FRENCH DOORS WITH SIDELITES AND TRANSOM | | | ABOVE AS SHOWN ON PLANS. (REPEAT COMMENT).FLORIDA | | | PRODUCT APPROVAL FL6573 SUBMITTED IS MISSING THE DOORS | | | DRAWINGS. PROVIDE COMPLETE PRODUCT APPROVAL INFORMATION | | | AND MAKE SURE DOORS INCLUDE THE TYPE OF DOORS SHOWN ON | | | PLANS. | | | | | | B) ARCHED AND RECTANGULAR CASEMENT WINDOWS AS SHOWN | | | ON PLANS. (REPEAT COMMENT).FLORIDA PRODUCT APPROVAL | | | FL6496 SUBMITTED IS MISSING THE WINDOW DRAWINGS. | | | PROVIDE COMPLETEPRODUCT APPROVAL INFORMATION AND MAKE | | | SURE WINDOWS INCLUDE THE ONES SHOWN ON PLANS. | | | | | | C) FIXED WINDOWS,INCLUDING THE ARCHED WINDOWS AS | | | SHOWN ON PLANS. (REPEAT COMMENT). | | | | | | D) WINDOW MULLIONS. AND CLEARLYMARK MULLION SIZE | | | ANDATTACHMENT TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES CALCULATED BY THE ENGINEER. (REPEAT | | | COMMENT). | | | | | | E) FLAT ROOF.CLEARLY MARKBASE SHEET FASTENING | | | OPTION TO BE USEDON PAGE 18 OF NOA 03-0501.05 | | | SUBMITTED AND PROVIDE RAS 117 CALCULATIONS FOR NAIL | | | ENHANCING AT PERIMETER AND CORNER AREAS AS REQUIRED BY | | | GENERAL LIMITATION #7. (REPEAT COMMENT). | | | | | | F)GARAGE DOORS.PROVIDE PRODUCT APPROVAL FOR DOOR | | | SIZE AS SHOWN ON PLANS. NOA 06-0331.04 SUBMITTED IS FOR | | | 14'-2"WIDE DOORS. | | | | | | 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 13-600.0 FBC 2004. (REPEAT COMMENT). AND MAKE SURE | | | CORRECTREVISED FORM IS USED. | | | | | | 7-A) PROVIDE COMPLETE ICYNENE SPECIFICATIONS TO | | | VERIFY COMPLIANCE WITHSEC.R314 OF 2004 FLORIDA | | | RESIDENTIAL CODE.AND TO CHECK FOR REQUIRED THICKNESS | | | TO ACHIEVE SPECIFIED R-VALUES.SEE ENERGY | | | CALCULATIONS AND PLANS. (REPEAT COMMENT). | | | | | | B) PROVIDE DETAIL/SPECS SHOWING HOW TO ACCOMPLISH | | | THE R-12 INSULATION WITH ICYNENE INSULATION ON EXISTING | | | WALLS.SEEICYNENE SPECIFICATIONS FOR REQUIRED | | | THICKNESS. | | | | | | 8- ARCHITECT TO SPECIFY CONSTRUCTION TYPE.INFORMATION | | | SUBMITTED IS INCOMPLETE. NEED TO SPECIFY IF | | | CONSTRUCTION TYPE V IS A OR B AS REQUIRED BY SEC. 602.1 | | | FBC 2004. | | | | | | 9- REVISE DIMENSIONS GIVEN FOR NEW STEPSTO COMPLY | | | WITH SEC. R311.5.3 OF 2004 FLORIDA RESIDENTIAL CODE. | | | GIVEN DIMENSIONS DON'T COMPLY. | | | | | | 10-DESIGNER OF RECORD TO SPECIFY ROOF TILE ATTACHMENT | | | AS REQUIRED BY SEC. 106.1.1.2 OF CITY AMENDMENTS TO FBC | | | 2004.IF USING POLY FOAM, THEN PROVIDE PRODUCT | | | APPROVAL. (REPEAT COMMENT).SEE ROOF TILE NOA FOR | | | LISTED POLYFOAM TO BE USED. | | | | | | 11-MISSING SHEET A-10. UNABLE TO CHECK IF | | | DETAILS/SPECIFICATIONS FORSTRUCTURAL BUCK TO BE | | | ATTACHED TO EXISTING AND NEW COLUMNSWERE PROVIDED. | | | THIS WAS REQUESTED ON PREVIOUS CHECKLIST. STRUCTURAL | | | PLANS DON'T PROVIDE THIS INFORMATION EITHER. | | | | | | 12- SHEET S4:UPDATE REFERENCE STANDARDS. SEE CHAPTER | | | 43 OF 2004 FLORIDA RESIDENTIAL CODE FOR CORRECT YEAR | | | THAT WAS ADOPTED BY THE2004 CODE. (REPEAT COMMENT). | | | | | | 13- PROVIDE SOIL TEST REPORT.SEC. R401.4 OF 2004 | | | FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT). | | | | | | 14- SHEET S5: REVISE DIMENSIONS GIVEN ON TYPICAL STEP | | | FOOTING DETAIL.COORDINATE WITH REVISED DIMENSIONS ON | | | ARCHITECTURAL PLAN.STEPS CAN'T HAVE 8" TREADS AND | | | RISERS. (REPEAT COMMENT). | | | | | | 15- ARCHITECT TO DATE WHEN SEALING THE PLANS AS | | | REQUIRED BY SEC. 61G-16.004 OF FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | 16- DRAWINGS ARE MISSING THE DOOR AND WINDOW | | | SCHEDULES. | | | | | | 17- BRINGREVISED PLANS TO THECITY HALL 5TH FLOOR | | | FOR HISTORICAL APPROVAL AND STAMP PRIOR TO SUBMITTAL TO | | | THIS OFFICE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-08-24 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-08-24 |
Time |
16:58 |
Sent To |
PC |
|
| Notes |
| 2007-08-24 17:00:19 | RESIDENTIALADDITION AND RENOVATION BUILDING REVIEW | | | FIRST CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC 2004 | | | WITH 2006/2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5115)TO VERIFY IF IMPACT FEES ARE DUE. BRING | | | BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF IMPACT | | | FEES ARE DUE. | | | | | | 3- PROVIDE PRODUCT APPROVALS FOR: | | | A) FRENCH DOORS "INSWING AND OUTSWING" AS SHOWN ON | | | PLANS. INCLUDING FRENCH DOORS WITH SIDELITES | | | ASSEMBLIES. | | | | | | B) ARCHED AND RECTANGULAR CASEMENT WINDOWS AS SHOWN | | | ON EXTERIOR ELEVATIONS. | | | | | | C) FIXED WINDOWS AS SHOWN ON PLANS. | | | | | | D) FRENCH DOORS WITH TRANSOMABOVE AS SHOWN ON | | | EXTERIOR ELEVATIONS. | | | | | | E) WINDOW MULLION. AND, CLEARLY INDICATE MULLION | | | SIZE AND ATTACHMENT TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES CALCULATED BY THE ENGINEER. | | | | | | F) FLAT ROOF.AND,CLEARLY IDENTIFY SPECIFIC | | | ASSEMBLY TO BE INSTALLED.ALSO, IF SELECTED ASSEMBLY | | | IS LIMITED BY GENERALLIMITATION #7, THEN PROVIDE RAS | | | 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND | | | CORNER AREAS. SEE GENERAL LIMITATION #7 ON LAST PAGE OF | | | NOA. IF THIS LIMITATION REQUIRES CALCULATIONS TO BE | | | DONE BY ANY OF THE LISTED PROFESSIONALS, THEN | | | CALCULATIONSMUST BE DONE BY ANY ONE OF THEM. | | | IF-SELECTED ASSEMBLY IS LIMITED BY GENERAL LIMITATION | | | #9, THEN IT CAN'T BE USED IN THIS AREA. | | | | | | G) ROOF TILE. | | | | | | H) GARAGE DOORS. | | | | | | I) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER | | | PAGE AND SPECIFIC SHEET WHERE CONNECTOR IS SHOWN TO | | | SAVE PAPER. | | | | | | 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 5- ONLY TWO SETS OF PLANS AND PRODUCT APPROVALS ARE | | | REQUIRED. NOT THREE. | | | | | | 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 13-600.0 OF FBC 2004. | | | | | | 7 PROVIDE COMPLETE ICYNENE SPECIFICATIONS. SEC. 106.1.2 | | | CITY AMENDMENTS TO FBC 2004. | | | | | | 8- PLANS TO SPECIFY CONSTRUCTION TYPE AS REQUIRED BY | | | SEC. 602.1 FBC 2004. | | | | | | 9- PROVIDE COMPLETE DIMENSIONSFOR NEW STEPS TO VERIFY | | | COMPLIANCE WITH SEC. R311.5.3 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 10- DESIGNER OF RECORD TO SPECIFY ROOF TILE ATTACHMENT | | | AS REQUIRED BY SEC. 106.1.1.2 OF CITY AMENDMENTS TO FBC | | | 2004.IF USING NAILS OR SCREWS, THEN SPECIFY SIZE AND | | | NUMBER TO BE USED. IF USING ADHESIVE, THEN SPECIFY | | | WHICH ONE AND PROVIDE PRODUCT APPROVAL AS REQUIRED BY | | | DCA RULE 9B-72. | | | | | | 11- SHEET A10: PROVIDE COMPLETE SPECIFICATIONS FOR | | | ATTACHMENT OF STRUCTURAL BUCKS TO EXISTING AND NEW | | | COLUMNS. STRUCTURAL PLANS DON'T PROVIDE THIS | | | INFORMATION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 12- SHEET S4: | | | A) UPDATEREFERENCE STANDARDS SPECIFIED ALL GENERAL | | | NOTES. SEECHAPTER 43 OF 2004 FLORIDA RESIDENTIAL CODE | | | AND CHAPTER 35 OF FBC 2004 FOR CORRECTREFERENCE | | | STANDARDS AND YEAR ADOPTED BY THE CODE AND REVISE ALL | | | NOTES AS REQUIRED. | | | | | | B) PROVIDE SOIL TEST REPORT REFERENCED ON FOUNDATION | | | NOTE #1. | | | | | | C) SPECIFY CONNECTOR AT TOP OF STEEL COLUMN SC-1. | | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | D) PLYWOOD ROOF SHEATHING THICKNESS SPECIFIED ON | | | WOOD NOTE 5(A) DOESN'T MATCH THICKNESSSPECIFIED ON | | | DETAILS SHOWN ON SHEET S6. REVISE AS REQUIRED TO | | | MATCH. | | | | | | E) REVISE SECTION SPECIFIED ON NOTE #1 BELOW THE | | | WIND LOAD SCHEDULE CHART. SEE FBC 2004 FOR CORRECT | | | SECTION TO BE CITED. | | | | | | 13- SHEET S5: | | | A) REVISE DIMENSION SHOWN ON TYPICAL STEP FOOTING | | | DETAIL. SEE ITEMCOMMENTS ON ITEM #9 ABOVE. | | | | | | B) REVISE NOTE #1 BELOW TYPICAL WOOD BUCK TO | | | CONCRETE CONNECTION DETAIL. REVISE FBC 2001 AND SECTION | | | CITED FOR OPENING PROTECTION. SEE FBC 2004 FOR CORRECT | | | SECTION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-14 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-11 |
Time |
14:32 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-13 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-12 |
Time |
07:03 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-27 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-26 |
Time |
16:40 |
Sent To |
M |
|
| Notes |
| 2007-12-27 08:55:04 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} DUE TO THE METER LOCATION, A DISCONNECT IS REQUIRED | | | PER225.32 AT THE MAIN HOUSE. SEE "IMMEDIATE POINT OF | | | ENTRANCE" IN THAT ARTICLE. INDICATE LOCATION ON PLAN | | | PER 230.72(A)(1) | | | | | | 2} THE DINING ROOM ADDITION MUST COMPLY WITH 210.52 | | | RCEPTACLE SPACING REQUIREMENTS. LOCATE ON PLANS. NOTE: | | | IN A DINING ROOM A SMALL APPLIANCE CIRCUIT IS REQUIRED | | | PER 210.52(B)(1). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-20 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-20 |
Time |
06:22 |
Sent To |
P |
|
| Notes |
| 2007-08-20 08:15:57 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | | FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH | | | THE FOLLOWING: | | | | | | 1} PLEASE PROVIDE A PANEL SCHEDULE SO THAT | | | BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT | | | PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC | | | AS AMENDED. SEE PANEL "A" AND PANEL "C", SHEET E-3, ARE | | | INCOMPLETE. NOTE IF ALL SERVICE EQUIPMENT ON THE RISER | | | AND PLANS ARE BEING INSTALLED UNDER THIS PERMIT, OR | | | WHICH MAY BE EXISTING. | | | | | | 2} AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED | | | FROM THE FIRST MEANS OF DISCONNECT TO THE PANEL PER | | | 250.118, SIZED PER 250.122. NONE IS SHOWN WITH THE | | | FEEDER FROM THE 225 AMP MAIN TO PANEL "A". | | | | | | 3}PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | | SIZE AND TYPE, INCLUDING THE GUTTER CONDUCTORS, NIPPLES | | | AND CONDUCTORS FEEDING OUT OF THE GUTTER. PANEL "C" IS | | | NOTED ON THE PANEL SCHEDULE WHICH IS SUFFICIENT. | | | | | | 4} IN THE ELECTRICAL SPECIFICATIONS, SHEET E-3, NUMBER | | | 3 C, INDICATES NO CONDUCTORS LARGER THAN THAN #8 MAY BE | | | SPLICED. THE 250 MCM ASSUMED TO BE IN THE GUTTER MUST | | | BE TAPPED. PLEASE CHECK ALL NOTES FOR RELEVANCE TO THIS | | | PROJECT AND REMOVE THE ONES THAT AREN'T, AND CLARIFY | | | THE ONES THAT ARE. ALSO SEE THE NOTE ABOUT NO ROMEX | | | BEING ALLOWED, (2D). IF NOTES ARE PART OF THE | | | CONSTRUCTION DOCUMENTS THEY WILL BE REGARDED AS | | | INSTALLATION INSTRUCTIONS BY THE DESIGNER AND MUST BE | | | ADHERED TO. ANY FIELD CHANGES WILL NEED TO BE REVISED | | | ON THE PLAN AND RESUBMITTED FOR REVIEW. | | | | | | 5} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | | INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS | | | SHALL BE INTERCONNECTED AND HARD WIRED. LOCATE THESE | | | ALARMS ON THE PLAN. | | | | | | 6} 210.52(C)(2) ISLAND COUNTER SPACES AT LEAST ONE | | | RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER | | | SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR | | | GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR | | | GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN | | | ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE | | | RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE | | | RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND | | | INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN | | | 210.52(C)(4). NONE ARE SHOWN FOR THE NEW KITCHEN | | | ISLAND. LOCATE ON THE PLAN. | | | | | | FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE | | | FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE INDICATE | | | THE CODE CYCLES UNDER WHICH THIS PLAN WAS DESIGNED. | | | ELECTRICAL SPECIFICATIONS, GENERAL SPECIFICATIONS "D", | | | IS VAGUE, AND IN NO WAY INDICATES THE CODES BEING | | | REFERRED TO. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2007-07-31 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2007-07-31 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2007-07-31 12:14:08 | HISTORICAL APPROVAL PER FREDERIKE MITTNER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-14 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-14 |
Time |
10:47 |
Sent To |
B |
|
| Notes |
| 2008-05-14 10:48:28 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-10 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-10 |
Time |
12:30 |
Sent To |
Z |
|
| Notes |
| 2008-04-10 12:30:33 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-10 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-10 |
Time |
11:49 |
Sent To |
Z |
|
| Notes |
| 2008-03-10 11:49:43 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-20 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2007-12-20 17:30:08 | SENT TO ZONING INBOX MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-08-24 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-08-02 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2007-08-02 15:40:43 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-23 |
Time |
11:25 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-23 |
Time |
11:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-14 |
Time |
09:00 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-03-14 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
| 2008-03-14 15:09:09 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, | | | PER 2004 FBC 13-600.3.A, (12-8-06 REVISION). | | | | | | 2) WHEN RESUBMITTING ENERGY CALCULATIONS HAVE THEM | | | SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC 13-103.3. | | | | | | 3) PLEASE SUBMIT THE COMPLETE COOLING LOAD CALCULATIONS | | | FOR EACH ZONE NOT JUST ONE PAGE FOR THE WHOLE HOUSE, | | | PER 2004 FBC 13-607.1.ABC.1. | | | | | | 4) SEE PLAN M-3 RTU MOUNTING DETAIL, STATES 'SEE F.B.C. | | | CHAPTER-16 TABLE 1606.1.4 FOR SIZE AND ETC.'. THE 2004 | | | FBC HAS NO TABLE 1606.1.4 IN CHAPTER 16 PLEASE REMOVE | | | FROM PLAN AND PROVIDE AN ENGINEERED DETAIL FOR SECURING | | | THE RTU'S TO WITHSTAND WIND LOADS UP TO 140 MPH, PER | | | 2004 FBC 1609 AND FBC/R M1307.3. | | | | | | 5) PLEASE ADD A NOTE TO THE MECHANICAL PLANS. THE | | | MANUFACTURER'S SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS WILL BE ON THE JOB FOR THE INSPECTOR | | | SHOWING THE RTU'S ARE DESIGNED TOWITH-STANDING WIND | | | LOADS UP TO 140 MPH PER 2004 FBC 1609, OR YOU MAY | | | SUBMIT THE MANUFACTURER'S SPEC'S. NOW. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-27 |
Time |
10:45 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2007-12-27 |
Time |
10:45 |
Sent To |
P |
|
| Notes |
| 2007-12-27 10:49:44 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, AND CHAPTER 1 | | | CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | *** DENIED *** | | | 1) AS REQUESTED IN LAST REVIEW 8-14-07.PLEASE SUBMIT | | | ENERGY CALCULATIONS, SEE 2004 FBC 13-101.2.3. | | | | | | 2) AS REQUESTED IN LAST REVIEW 8-14-07. PLEASE SUBMIT | | | COOLING LOAD CALCULATIONS, SEE 2004 FBC | | | 13-607.1.ABC.1. | | | | | | 3) MECHANICAL PLAN FOR FIRST FLOOR PAGE M-1 IS MISSING | | | FROM SUBMITTED PLANS, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL: [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-14 |
Time |
07:57 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-08-14 |
Time |
07:57 |
Sent To |
E |
|
| Notes |
| 2007-08-14 08:08:36 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | *** DENIED *** | | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC | | | 13-101.2.3. | | | | | | 2) PLEASE SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 | | | FBC 13-607.1.ABC.1. | | | | | | 3) SHOW ON MECHANICAL PLANS PAGE M-2 HOW RETURN AIR IS | | | BEING PROVIDED FOR TO AC-1, SEE 2004 FBC/R M1602.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL: [email protected]. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-14 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-14 |
Time |
16:28 |
Sent To |
B |
|
| Notes |
| 2008-04-14 16:30:50 | NOTE: NEW P-1 SHEET. PER TOM GORDONS INSTRUCTIONS PLANS | | | ROUTED TO BLDG., MECHANICAL TO REVIEW LAST. | | | | | | ****************PROVISO**************** | | | THE FIXTUES IN THE POWDER ROOM SHALL CONFORM TO THE | | | FOLLOWING. | | | P2705.1 GENERAL. (FBC PLUMBING RESIDENTIAL) | | | THE INSTALLATION OF FIXTURES SHALL CONFORM TO THE | | | FOLLOWING: | | | 5.THE CENTERLINE OF WATER CLOSETS OR BIDETS SHALL | | | NOT BE LESS THAN 15 INCHES (381 MM) FROM ADJACENT WALLS | | | OR PARTITIONS OR NOT LESS THAN 15 INCHES (381 MM) FROM | | | CENTERLINE OF A BIDET TO THE OUTERMOST RIM OF AN | | | ADJACENT WATER CLOSET. THERE SHALL BE AT LEAST 21 | | | INCHES (533 MM) CLEARANCE IN FRONT OF THE WATER CLOSET, | | | BIDET OR LAVATORY TO ANY WALL, FIXTURE OR DOOR. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-14 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-14 |
Time |
11:45 |
Sent To |
M |
|
| Notes |
| 2008-03-14 11:53:28 | ****************PROVISO**************** | | | THE FIXTUES IN THE POWDER ROOM SHALL CONFORM TO THE | | | FOLLOWING. | | | P2705.1 GENERAL. (FBC PLUMBING RESIDENTIAL) | | | THE INSTALLATION OF FIXTURES SHALL CONFORM TO THE | | | FOLLOWING: | | | 5.THE CENTERLINE OF WATER CLOSETS OR BIDETS SHALL | | | NOT BE LESS THAN 15 INCHES (381 MM) FROM ADJACENT WALLS | | | OR PARTITIONS OR NOT LESS THAN 15 INCHES (381 MM) FROM | | | CENTERLINE OF A BIDET TO THE OUTERMOST RIM OF AN | | | ADJACENT WATER CLOSET. THERE SHALL BE AT LEAST 21 | | | INCHES (533 MM) CLEARANCE IN FRONT OF THE WATER CLOSET, | | | BIDET OR LAVATORY TO ANY WALL, FIXTURE OR DOOR. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-28 |
Time |
11:33 |
Sent To |
B |
|
| Notes |
| 2007-12-28 13:12:20 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE STILL | | | REQUIRED FOR PLUMBING PLAN REVIEW TO MEET CODE | | | COMPLIANCE. | | | **NOTE: THERE WAS NOT A TRANSMITTAL LETTER ADDRESSING | | | PREVIOUS PLUMBING PLAN REVIEW COMMENTS. | | | | | | **PREVIOUS REVIEW COMMENTS** | | | | | | 1. OK | | | | | | 2. **COMMENT NOT ADDRESSED** | | | SHEET P-1: SPECIFY HOW THE ELECTRIC WATER HEATER IN THE | | | GARAGE WILL BE PROTECTED FROM MECHANICAL DAMAGE AS | | | REQUIRED BY FBC, 2004 MECHANICAL, SECTION 303.4. | | | **SHEET P-1 REVIEW COMMENT REV. #1 INDICATES SEE SHEET | | | P-3 WATER HEATER DETAIL, HOWEVER SHEET P-3 WATER HEATER | | | DETAIL ONLY INDICATES TOP OF TANK AT 92". THERE IS NO | | | INDICATION ON HOW WATER HEATER IS BEING PROTECTED. | | | PLEASE COMPLY. | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. **COMMENT NOT ADDRESSED** | | | SHEET P-2 SANITARY RISER S-2: THE WASHING MACHINE | | | BRANCH DRAIN AND DRAINAGE STACK ARE SIZED WRONG. PER | | | *406.3 MINIMUM THREE INCH (3") REQUIRED. | | | **NOTE: PER *102.1 GENERAL. WHERE, IN ANYSPECIFIC | | | CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT | | | MATERIALS, METHODS OF CONSTRUCTION OR OTHER | | | REQUIREMENTS, THE MOST RESTRITIVE SHALL GOVERN. | | | | | | 6. OK | | | | | | 7. A} OK AND B} OK | | | | | | 8. OK | | | | | | **THE FOLLOWING ARE NEW COMMENTS** | | | | | | 9. SHEET A-1 GUEST ROOM INDICATES A NEW SHOWER AND | | | SHEETS P-1 AND P-3 ARE INDICATING TUBS. PLEASE | | | CORRELATE THE PLANS ON THE RESUBMITTAL. PER *106.1.1, | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 10. SHEETS P-1, P-2, AND P-3 ONLY ONE SET OF THESE | | | SHEETS ARE SIGNED AND SEALED BY ENGINEER OF RECORD | | | MICHAEL A. TEELE, P. E. #32066. PER *106.1, SUBMITTAL | | | DOCUMENTS TWO COMPLETE SETS ARE REQUIRED AND THEY SHALL | | | BE SIGNED AND SEALED PER *CHAPTER 471, FLORIDA | | | STATUTES. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-27 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-21 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2007-08-21 17:00:40 | DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET P-1: CLEARLY INDICATE THE WATER HEATER SIZE | | | IN THE GARAGE AND CLARIFY IF THE WORDING FOR THE GARAGE | | | WATER HEATER IS SUPPOSED TO BE"WATER HEATER FOR GUEST | | | RM BATH OR GUEST HOUSE." | | | | | | 2. SHEET P-1: SPECIFY HOW THE ELECRIC WATER HEATER IN | | | THE GARAGE WILL BE PROTECTED FROM MECHANICAL DAMAGE AS | | | REQUIRED BY FBC-2004 MECHANICAL, SECTION 303.4. | | | | | | 3. SHEET P-2: CLEARLY INDICATE THE WATER HEATER SIZE | | | IN THE A/C CLOSET AND PER FBC-2004 PLUMBING, SECTION | | | 504.7 WHERE A WATER HEATER IS INSTALLED ABOVE THE | | | GROUND FLOOR THE WATER HEATER SHALL BE INSTALLED IN A | | | PAN.. | | | | | | 4. SHEET P-2 ELECTRIC WATER HEATER DETAIL: INDICATE | | | THERMAL EXPANSION CONTROL PER FBC-2004 PLUMBING | | | SECTION, 607.3. (SHEET A-1 IS INDICATING AN EXISTING | | | SWIMMING POOL WHICH MEANS A RPZV BACKFLOW PREVENTER IS | | | ON POTABLE WATER SERVICE) | | | | | | 5. SHEET P-2 SANITARY RISER S-2: THE WASHING MACHINE | | | BRANCH DRAIN OR DRAINAGE STACK IS SIZED WRONG A MINIMUM | | | OF 3 INCH IS REQUIRED PER FPC-2004 PLUMBING, SECTION | | | 406.3. | | | | | | 6. SHEET P-2 SANITARY RISER DIAGRAM: CLEARLY INDICATE | | | WHERE THE 1ST FLOOR VENTING FROM BELOW IS LOCATED AND | | | WHERE IT TIES INTO THE 2ND FLOOR VENT THRU ROOF | | | (V.T.R.) PER FBC-2004 PLUMBING, SECTION 903.3. | | | | | | 7. SHEET P-3 ELECTRIC WATER HEATER SCHEMATIC: | | | | | | A} INDICATE THERMAL EXPANSION CONTROL PER FBC-2004 | | | PLUMBING, SECTION 607.3.(SHEET A-1 IS INDICATING AN | | | EXISTING SWIMMING POOL WHICH MEANS A RPZV BACFLOW | | | PREVENTER IS ON THE POTABLE WATER SERVICE) | | | | | | B} PER FBC-2004 PLUMBING, SECTION 606.1 A FULL- OPEN | | | VALVE SHALL BE INSTALLED ON THE WATER SUPPLY PIPE TO | | | THE WATER HEATER. | | | | | | 8. SHEET P-3 SANITARY RISER DIAGRAM: CLEARLY INDICATE | | | WHERE THE VENT IS GOING UP TO THE 2ND FLOOR VENT SYSTEM | | | FROM THE 1ST FLOOR VENTS PER FBC-2004 PLUMBING, SECTION | | | 903.3. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING IN RED INK ON | | | THE INDICATED PLAN SHEETS BY THIS PLAN EXAMINER FOR | | | REFERENCE FOR THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-11 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-11 |
Time |
08:44 |
Sent To |
E |
|
| Notes |
| 2008-04-11 08:47:24 | ***APPROVED - RESUB #3*** | | | | | | PROVISOS: | | | 1)DECORATIVE ELEMENTS OF THE FRONT GARDEN WALL SHALL | | | NOT EXCEED 4 FEET 4 INCHES IN HEIGHT (4' ALLOWABLE, | | | PLUS 10% FOR DECORATIVE ELEMENTS), MEASURED FROM | | | GRADE. | | | 2)PROPOSED OUTDOOR SHOWER SHALL BE SETBACK A MINIMUM | | | OF 5 FEET FROM THE REAR PROPERTY LINE AND SHALL NOT | | | ENCROACH THE REAR UTILITY EASEMENT. | | | | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-11 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-11 |
Time |
08:48 |
Sent To |
E |
|
| Notes |
| 2008-03-11 08:58:18 | ***FAILED - RESUB #2*** | | | | | | | | | NEW COMMENTS: | | | | | | 1)PLANS INCONSISTENT.A/C AND POOL EQUIPMENT | | | LOCATION DO NOT MATCH BETWEEN SITE PLAN (A-1) AND MEP | | | PLANS (P-1, M-1, E-1).WHERE IS THE EQUIPMENT TO BE | | | LOCATED?THE EQUIPMENT DOES NOT MEET SETBACK | | | REQUIREMENTS AS SHOWN ON MEP'S, ADDITIONALLY, THE | | | EQUIPMENT SHALL NOT BE PERMITTED WITHIN THE REAR | | | UTILITY EASEMENT OF 5'.PLEASE REVISE PLANS TO BE | | | CONSISTENT AND TO SHOW THE EQUIPMENT WITHIN THE | | | REGULATIONS SET FORTH IN SECTION 94-305 OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS. | | | | | | | | | NOTE:DECORATIVE ELEMENTS OF THE FRONT GARDEN WALL | | | SHALL NOT EXCEED 4 FEET 4 INCHES IN HEIGHT, MEASURED | | | FROM GRADE. | | | | | | NOTE:PROPOSED OUTDOOR SHOWER SHALL BE SETBACK A | | | MINIMUM OF 5 FEET FROM THE REAR PROPERTY LINE AND SHALL | | | NOT ENCROACH THE REAR UTILITY EASEMENT. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-12-24 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-12-24 |
Time |
14:36 |
Sent To |
E |
|
| Notes |
| 2007-12-24 14:44:21 | ***FAILED*** | | | | | | | | | REPEAT COMMENTS: | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | | SHOWING THE SCOPE OF WORK WITH SETBACK DIMENSIONS TO | | | THE PROPERTY LINES. | | | | | | 2)THE PROPOSED GARDEN WALLS WILL REQUIRE AN APPROVED | | | EASEMENT CONSENT FORM FROM THE CITY OF WEST PALM BEACH | | | DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY HALL) | | | | | | NEW COMMENTS: | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM | | | PROPOSED/RELOCATED POOL EQUIPMENT AND A/C EQUIPMENT TO | | | THE PROPERTY LINES.AS PER SECTION 94-305(B)(4) OF THE | | | ZLDRS: MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN | | | 4' INTO A REQUIRED SETBACK. | | | | | | 2)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE, | | | LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE | | | SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION | | | 94-442 AND 94-445 OF THE ZLDRS. | | | | | | 3)PLANS SHALL BE RESTAMPED BY HISTORIC PRESERVATION | | | AND/OR ORIGINAL APPROVAL LETTER FROM HISTORIC | | | PRESERVATION SHALL BE SUBMITTED ALONG WITH PERMIT | | | APPLICATION PACKET. | | | | | | | | | ***NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION | | | MAY GENERATE ADDITIONAL COMMENTS.*** ***NEW COMMENTS | | | ARE LIKELY TO ARISE UNTIL ALL REQUESTED INFORMATION IS | | | SUBMITTED.*** | | | | | | NOTE:IT IS HELPFUL TO HAVE ALL SUBMITTED PLANS | | | ORGANIZED INTO TWO (2) DISTINCT PACKETS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-06 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-06 |
Time |
14:18 |
Sent To |
E |
|
| Notes |
| 2007-08-06 14:23:41 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY | | | SHOWING THE SCOPE OF WORK WITH SETBACK DIMENSIONS TO | | | THE PROPERTY LINES. | | | | | | 2)AS YOU ARE PROPOSING A GARDEN WALL, PROVIDE AN | | | EASEMENT CONSENT FORM FROM THE CITY OF WEST PALM BEACH | | | DEPARTMENT OF PUBLIC UTILITIES (1ST FLOOR, CITY HALL) | | | | | | 3)PROVIDE ELEVATION DIMENSIONS FROM GRADE TO THE | | | MIDPOINT OF THE ROOF'S PITCH (OF THE ADDITION). | | | | | | 4)INDICATE ROOF OVERHANG DIMENSIONS. | | | | | | 5)PROVIDE AN ELEVATION AND DIMENSIONS OF TERRACE AND | | | STEPS. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|