Plan Review Details - Permit 07071039
| Plan Review Stops For Permit 07071039 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-27 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-27 |
Time |
10:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-31 |
Time |
11:23 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-01-31 |
Time |
11:23 |
Sent To |
PC |
|
| Notes |
| 2008-01-31 11:24:32 | PERMIT: 07071039 | | | ADD: 234 SOUTHERN BLVD | | | CONT: LEONARD ALBANESE & SONS BUILDERS, INC | | | TEL: (561)239-2034 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW/ JAN. 31/08 | | | ACTION: REVIEWED | | | | | | | | | BUILDING PROVISOS: | | | | | | BUIULDING PROVISO: LIGHT POLES,TO BE SUBMITTED AS | | | SHOP DRAWINGS. | | | | | | BUILDING PROVISO:109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | | BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. | | | THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE | | | A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | | COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATION FROM A LICENSED ENGINEER | | | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-24 |
Time |
11:50 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-01-24 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2008-01-31 08:43:28 | PERMIT: 07071039 | | | ADD: 234 SOUTHERN BLVD | | | CONT: LEONARD ALBANESE & SONS BUILDERS, INC | | | TEL: (561)239-2034 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW/ JAN. 31/08 | | | ACTION: REVIEWED | | | | | | | | | BUILDING PROVISOS: | | | | | | BUIULDING PROVISO: LIGHT POLES,TO BE SUBMITTED AS | | | SHOP DRAWINGS. | | | | | | BUILDING PROVISO:109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | | BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. | | | THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE | | | A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | | COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATION FROM A LICENSED ENGINEER | | | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | 2008-01-24 11:55:28 | PERMIT: 07071039 | | | ADD: 234 SOUTHERN BLVD | | | CONT: LEONARD ALBANESE & SONS BUILDERS, INC | | | TEL: (561)239-2034 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW/ JAN. 24/08 | | | ACTION: DENIED | | | | | | PLANS APPEAR TO BE CODE COMPLIANT, STILL NEED TO PAY | | | IMPACT FEES. | | | | | | BUILDING PROVISOS: | | | | | | BUIULDING PROVISO: LIGHT POLES,TO BE SUBMITTED AS | | | SHOP DRAWINGS. | | | | | | | | | BUILDING PROVISO:109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | | BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. | | | THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE | | | A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | | COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATION FROM A LICENSED ENGINEER | | | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-02 |
Time |
13:53 |
Rev Time |
4.33 |
| Received By |
jwitmer |
Date |
2007-11-02 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2007-11-02 13:55:45 | PERMIT: 07071039 | | | ADD: 234 SOUTHERN BLVD | | | CONT: LEONARD ALBANESE & SONS BUILDERS, INC | | | TEL: (561)239-2034 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW/ NOV. 02-07 | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT | | | --- | | | PLEASE DO NOT | | | IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3-7) COMPLIED. | | | | | | 8) 2ND REQUEST,A SINGLE SIGNED AND SEALEDGFA | | | INTERNATIONAL GEOTECHNICALREPORT WAS SUBMITTED, TWO | | | ORIGINAL SIGNED AND SEALED REPORTS ARE REQUIRED. NOTE | | | NOT THE SUMMARY OF DRAINAGE CALCULATIONS FROM NUTTING | | | ENGINEERING. | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING | | | VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS | | | CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE | | | NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4 | | | THROUGH 1802.6 . | | | | | | 9)2ND REQUEST,THERE SEEMS TO BE A DISCREPANCY | | | BETWEEN THE PERMIT APPLICATION WORK TO BE COMPLETED | | | UNDER THIS BUILDING AND THE ENERGY EFFICIENCY CODE | | | ENERGY CALCS. | | | THE ENERGY CALCULATIONS ARE STATING THAT THEY ARE FOR A | | | SHELL BUILDING , THE DESIGNER OF RECORD IN THE LAST | | | RESPONCE INDICATED THIS TO BE A "COMPLETE BUILDOUT". | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 10-14) COMPLIED. | | | | | | 15) 2ND REQUEST, DEALS WITH NON-ABSORBENT SURFACES | | | AROUND FIXTURES. THE EPOXY PAINT ON DRYWALL HAS NOT | | | BEEN ESTABLISHED AS A NON-ABSOBENT MATERIAL SINCE IT | | | CAN GET NICKS IN THE SURFACE THROUGH OUT THE LIFE TIME | | | OF THE INSTALATION. | | | PLEASE COMPLY WITH 1210.2 FOR WALLS , WITH SMOOTH, HARD | | | NONABSORBENT SURFACES TO A HEIGHT OF 4'-0" FOR FIXTURES | | | THATTHE WALLS CAN BE ADVERSELY AFFECTED BY MOISTURE. | | | | | | 16)-17) COMPLIED. | | | | | | 18) 2ND REQUEST, SHEET S-01& S-06 NOTES NUMBER THREE | | | REINFORCING STEEL. VERTICAL WALL REINFORCINGS-01 | | | INDICATES VERTICAL REINFORCEMENT @ NEXT TO ALL | | | OPENINGS, AND CORNERS, BUT IN A STRAIGHT WALL THERE IS | | | NO CENTER TO CENTER SPACING PROVIDED ON | | | SHEET S-01 OR IN THE NOTES ON S-06. RECITING THE CODE | | | OR A REFERENCE STANDARD DOES NOT PROVIDE THE | | | INFORMATION NEEDED FOR THE INDIVIDUAL WHO IS IN THE | | | FIELD.106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. ACI 530- 8.1.2 | | | DETAILS OF REINFORCEMENTSHALL BE SHOWN ON PLANS OR | | | COVERED BY NOTES ON THE PROJECT DRAWINGS. | | | | | | 19-22) COMPLIED. | | | | | | 23) BUIULDING PROVISO: LIGHT POLES,TO BE SUBMITTED AS | | | SHOP DRAWINGS | | | | | | 24)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, | | | MISSING REPORTS ARE AS FOLLOWS: | | | | | | 24 E) TRUSS ANCHORS- NO REPORT SUBMITTED | | | | | | 25-27) COMPLIED. | | | 28)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 29) BUILDING PROVISO:109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL | | | OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE | | | A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | | COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATION FROM A LICENSED ENGINEER | | | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 30) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW | | | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO | | | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION | | | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE | | | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR | | | SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS | | | WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED | | | SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN | | | ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO | | | VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE | | | PURSUANT TO SECTION 113 OF THIS CHAPTER. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-08 |
Time |
10:39 |
Rev Time |
5.66 |
| Received By |
jwitmer |
Date |
2007-09-07 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2007-09-08 10:41:15 | BUILDING PLAN REVIEW | | | PERMIT: 07071039 | | | ADD: 234 SOUTHERN BLVD | | | CONT: LEONARD ALBANESE & SONS BUILDERS, INC | | | TEL: (561)239-2034 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1SRREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT | | | --- | | | PLEASE DO NOT | | | IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) SLATTERY & ASSOCIATES ARCHITECTSPLANNERS, | | | 61G1-16.004FL. ADMIN. CODE.PLANS PREPARED BY A | | | REGISTERED ARCHITECT SHALL | | | INCLUDE A TITLE BLOCK WHICH MUST: | | | - STATE THE FIRM NAME, ADDRESS AND | | | TELEPHONE NUMBER | | | - STATE THE FIRM LICENSE NUMBER | | | - STATE PROJECT NAME OR IDENTIFICATION - | | | STATE DATE PREPARED | | | - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEAL | | | XX- INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING | | | THE PLANS, NOTE THE | | | FLORIDA REGISTRATION NUMBER BY THE RAISED | | | SEAL IS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | | | | 4) STRUCTURAL PLANS, THE ENGINEERING FORM SA-TECH | | | ENGINEERING, INC. HASN?T INCLUDED THEIR CERTIFICATE OF | | | AUTHORIZATION.471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET BEARING | | | THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A | | | PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL | | | INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. | | | | | | 5) STRUCTURAL SHEETS ARE MISSING INFORMATION IN THE | | | TITLE BLOCK: | | | SEE FAC 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | | | | 6) A WARRANTY DEED WAS SUBMITTED AS PROOF OF OWNERSHIP, | | | IN THIS DOCUMENT IT INDICATES (2) PARCELS PARCEL A & | | | PARCEL B. THE PERMIT APPLICATION INDICATES THIS | | | BUILDING IS BEING BUILT ON LOT 285 BUT IN LOOKING AT | | | THE PROPERTY TAX MAPS IT APPEARS THAT THE STRUCTURE | | | TRANSGRESSES THE PROPERTY LINE ON TO LOT 291 ALSO, A | | | UNITY OF TITLE WILL BE REQUIRED. THE PROPOSED BUILDING | | | STRUCTURE TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE | | | LOTS WHICH COMBINE TO FORM 'THE SITE'.A 'UNITY OF | | | TITLE' SHALL BE RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF TITLE' DOCUMENT | | | SO THAT FBC TABLE 600 BOUNDARY LINE REQUIREMENTS MAY BE | | | DEEMED NOT APPLICABLE. | | | | | | 7) 106.1.2* ADDITIONAL INFORMATION IS REQUIRED. THE | | | COVER SHEET INDICATES THE OWNERS TO BE LOCKS OF LOVE, | | | INC.THE PLANS INDICATE THIS TO BE A BUSINESS | | | OCCUPANCY AND THE PLANS ONLY INDICATE THE USE OF THE | | | ROOMS AS OFFICES. PLEASE IDENTIFY THE ROOMS WHICH WILL | | | BE USING X-RAY EQUIPMENT THIS ASSUMPTION IS MADE | | | BECAUSE OF THE CODE CRITERIA FOUND ON A-001 REPORT# 34 | | | MEDICAL X-RAY AND GAMMA RAY. PLEASE PROVIDE ADDITIONAL | | | INFORMATION. MORE COMMENTS MAY APPEAR ON THE NEXT | | | REVIEW DEALING WITH THIS ISSUE. | | | | | | 8) A SINGLE SIGNED AND SEALEDGFA INTERNATIONAL | | | GEOTECHNICALREPORT WAS SUBMITTED, TWO ORIGINAL SIGNED | | | AND SEALED REPORTS ARE REQUIRED. | | | | | | 9)THERE SEEMS TO BE A DISCREPANCY BETWEEN THE PERMIT | | | APPLICATION WORK TO BE COMPLETED UNDER THIS BUILDING | | | AND THE ENERGY EFFICIENCY CODE ENERGY CALCS. | | | THE ENERGY CALCULATIONS ARE STATING THAT THEY ARE FOR A | | | SHELL BUILDING ONLY, IS THIS | | | THE SCOPE OF WORK FOR THE BUILDING.IS THE PERMIT | | | APPLICATION WRONG IN SCOPE OF WORK OR THE ENERGY | | | CALCULATIONS? | | | 10) THE ENERGY CALCULATIONS INDICATE THIS IS TO BE A | | | METAL ROOF WHERE AS THE PLANS CALL FOR A SPANISH **S** | | | CONCRETE TILE ROOF PLEASE CORRECT. | | | | | | 11) THE ENERGY CALCULATIONS SHOULD ALSO CORRECT THE | | | WINDOW SECTION OF HE CALCS, THE PLANS ELEVATIONS ARE | | | LABELED BACKWARDSNORTH IS SOUTH AND EAST IS WEST, | | | PLEASE CORRECT BOTH THE PLANS AND ENERGY CALCULATIONS. | | | DISCREPANCIES. | | | | | | 12) PLEASE ALSO CORRECT THE ENERGY CALCULATIONS AS TO | | | TYPE OF INSULATION ENERGY CALCULATIONS INDICATE THE USE | | | OF R-19 INSULATION- BATT WHERE AS THE PLAN INDICATES | | | THE USE OF ICYNENE BUT NO R FACTOR OR DEPTH IS | | | PROVIDED, PLEASE CORRECT BOTH ISSUES. DISCREPANCIES. | | | | | | | | | 13) SHEET A-601 WINDOW BUCKS ARE INDICATED AS TAPERED | | | BUCKS NOT HAVING SUPPORT BY BOTH FACES OF THE WINDOW | | | FRAME.1714.5.4.2 MASONRY, CONCRETE OR OTHER | | | STRUCTURAL SUBSTRATE.UNLESS OTHERWISE TESTED, BUCKS | | | SHALL EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR | | | DOOR FRAME SUCH THAT FULL SUPPORT OF THE FRAME IS | | | PROVIDED. SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF | | | SUSTAINING APPLICABLE LOADS, LOCATED AND APPLIED IN A | | | THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. | | | ANCHORS SHALL BE PROVIDED TO TRANSFER LOAD FROM THE | | | WINDOW OR DOOR FRAME TO THE ROUGH OPENING SUBSTRATE. | | | | | | 14) SHEET A-901 DOOR SCHEDULE THIS IS PROBABLY A TYPE-0 | | | SEE DOOR HEIGHT OF DOOR # 113, 5?-6?. | | | | | | 15) SHEET A-901 ROOM SCHEDULE WALL AROUND THE WATER | | | CLOSETS INDICATES THE USE OF GYPSUM WALL BOARD, PLEASE | | | SEE: 1210.2 WALLS. SMOOTH, HARD, NONABSORBENT SURFACE, | | | TO A HEIGHT OF 4 FEET (1219 MM) ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN | | | SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY | | | AFFECTED BY MOISTURE. | | | | | | 16) SHEET A-201 ROOM 113 INDICATES A BREAK ROOM WITH | | | SINK, THE PLANS DO NOT HAVE ANY ELEVATIONS OF THE | | | CABINETRY PLEASE PROVIDE ELEVATIONS COMPLYING WITH: | | | SINKS:11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE MOUNTED | | | WITH THE COUNTER NO HIGHER THAN 34" ABOVE THE FINISH | | | FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH | | | 30" WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH | | | SINKS. | | | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT | | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR | | | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE | | | SINK. | | | | | | 17) SHEET A-201 IS MISSING ATTIC ACCESS:1209.2 ATTIC | | | SPACES. | | | AN OPENING NOT LESS THAN 20 INCHES BY 30 INCHES (559 MM | | | BY 762 MM) SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A | | | CLEAR HEIGHT OF OVER 30 INCHES (762 MM). A 30-INCH (762 | | | MM) MINIMUM CLEAR HEADROOM IN THE ATTIC SPACE SHALL BE | | | PROVIDED AT OR ABOVE THE ACCESS OPENING. | | | | | | 18) SHEET A-01 VERTICAL WALL REINFORCING NOTE # 5 | | | INDICATES ADDITIONAL # 5?S AS VERTICAL REINFORCING, | | | WHERE IS NOTE FOR THE CENTER TO CENTER VERTICAL | | | REINFORCING. ACI 530. | | | | | | 19) SHEET S-06 NOTE# 5 MASONRYSUB-NOTE JSECTION | | | 2122.4THIS IS HIGH VELOCITY HURRICANE, ZONE BROWARD | | | AND DADE COUNTIES PLEASE CORRECT. | | | | | | 20) SHEET S-06 STRUCTURAL NOTES 6-E INDICATE ROOF | | | SHEATHING TO COMPLY WITH 2322.2 THIS IS HIGH VELOCITY | | | HURRICANE, ZONE BROWARD AND DADE COUNTIES PLEASE | | | CORRECT. | | | | | | 21) SHEET S-06 NOTE # 9 DELEGATED ENGINEERING | | | RESPONSIBILITIES | | | NOTE # 9, 2319.17.2.1. AGAIN HIGH WIND HURRICANE ZONE, | | | BROWARD AND | | | DADE COUNTIES, PLEASE CORRECT. | | | | | | 22) SHEET S-06 NOTE# 12 CONDUITS AND PIPES EMBEDDED IN | | | CONCRETE | | | NOTE# 5 1925.3,2 THIS IS HIGH VELOCITY HURRICANE, | | | ZONE BROWARD AND DADE COUNTIES PLEASE CORRECT. | | | | | | 23) SHEET E1.1 ELECTRIC LIGHT POLE DETAIL PLEASE | | | REMEMBER THAT WHEN THE POLE SUPPLIER IS PROVIDING THE | | | LIGHT POLETHE DESIGN IS 140 MPH WITH A | | | EXPOSURE **C** CATEGORY. | | | | | | 24)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, (3) | | | IF PROJECT REQUIRES A THRESHOLD OR SPECIAL INSPECTOR , | | | MISSING REPORTS ARE AS FOLLOWS: | | | A) PICTURE WINDOW- REQUIRES FLORIDA COVER SHEET, | | | UPDATE TO CURRENT NOA OR | | | DIVIDE THE PRESSURES BY 1.33 OLDER NOA BEFORE | | | 2004 TOOK 1.33 STEEL | | | INCREASES IN FASTENERSOR HAVE ENGINEER CERTIFY | | | FASTENERS. | | | B) STORE FRONT-- REQUIRES FLORIDA COVER SHEET,C) | | | GLAZED EXTERIOR DOORS- REQUIRES FLORIDA COVER SHEET, | | | UPDATE TO CURRENT NOA OR DIVIDE THE PRESSURES BY 1.33 | | | OLDER NOA BEFORE 2004 TOOK 1.33 | | | STEEL INCREASES IN FASTENERSOR HAVE ENGINEER | | | CERTIFY FASTENERS | | | D) EXTERIOR METAL DOORS- NO REPORT SUBMITTED | | | E) TRUSS ANCHORS- NO REPORT SUBMITTED | | | F) ROOF ASSEMBLIES: | | | TILE : REQUIRES REPORT HIGHLIGHT TYPE OF ATTACHMENT | | | TO ROOF | | | UNDERLAYMENTS- REQUIRES BACKUP REPORT | | | | | | 25) THIS SUBMITTAL DOESN'T INCORPORATE ANY ROOFING | | | PRODUCT APPROVALS, HERE IS A LIST OF COMMON ISSUES THAT | | | WILL FAIL A ROOFING REPORT SUBMITTAL:THIS ROOF IS | | | MISSING OR NOT INCOMPLIANCE WITH THE FOLLOW | | | ITEMS: | | | _XX__ CONTRACTOR FAILED TO PROVIDE BACK UP ROOFING | | | REPORT DOCUMENTATION | | | ___ CONTRACTOR DID NOT PROVIDE THE MEANROOF HEIGHT. | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF PITCH. _XX__ | | | CONTRACTOR FAILED TO INDICATE WHICH SYSTEM OR SUBSYSTEM | | | WILL BE USED. | | | _XX__ THE SYSTEM PROVIDED HAS A LOW PRESSURE FOR ZONE | | | _2__ . | | | _XX__ THE SYSTEM PROVIDED STATES LIMITATION# 7, SHOULD | | | THE FASTENER RESISTANCE BE LESS THAN THATREQUIRED, AS | | | DETERMINED BY THE BUILDING OFFICIAL, A REVISED FASTENER | | | SPACING, PREPAREDSIGNEDAND SEALED BY A FLORIDA | | | REGISTEREDPROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF CONSULTANT MAY BE | | | SUBMITTED. | | | ___THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO | | | ENHANCED FASTENING ALLOWED. | | | | | | 26) PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO | | | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE | | | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, | | | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR | | | SITE SPECIFIC FORM PER | | | RULE 9B-72. | | | | | | 27) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 28)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 29) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | | AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION | | | MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE FLOWS | | | SERVING | | | ADJACENT PROPERTIES, & MAY REQUIRE SPECIAL DRAINAGE | | | DESIGN COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE | | | THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE | | | A | | | PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | | COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATION FROM A LICENSED ENGINEER | | | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 30) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-04 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-04 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2008-05-04 11:49:24 | ** PROVISO** | | | | | | 1) NOTE: PLEASE SEE FBC 13-415.2, 13-415.2.ABC.1.1, | | | .1.2, .1.3 AS ALL REVISED LIGHTING ON ANY PROJECT SHALL | | | HAVE REVISED ENERGY CALCULATIONS. PLEASE SUBMIT REVISED | | | ENERGY CALCULATIONS WITH ANY CHANGES FOR REVIEW BEFORE | | | FINAL ELECTRICAL INSPECTIONS. THESE MAY ALSO BE | | | SUBMITTED AT ANY TIME AS TO MAKE SURE THESE ARE ON FILE | | | AND ON JOBSITE FOR INSPECTION. | | | 13-400.3.A | | | | | | | | | ** ELECTRICAL SHEETS STILL NEED FIRE REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-30 |
Time |
19:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-30 |
Time |
19:49 |
Sent To |
|
|
| Notes |
| 2008-01-30 19:51:51 | ** REDLINED SHEET E2.1 WHICH INDICATES TABLE *C*. | | | METHID *A* IS ATTACHED PER 13-415.1.A,13-101.1.2. | | | NO CORRECTIONS ARE NEEDED. ELECTRICAL PLANS STAMPED. | | | STILL NEEDS FIRE REVIEW TO STAMP FA SHEETS, |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-03 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-01 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2008-01-03 13:54:45 | 2008-01-03 | | | | | | ** DENIED 3RD REVIEW ** | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING. | | | | | | 1) NOTE: PLEASE SEE COMMENTS FROM PREVIOUS REVIEW WITH | | | RESPECT TO THE SUBMITTED ENERGY CALCULATIONS AND | | | COORDINATION WITH PLANS. | | | PLEASE BE SURE THE FIXTURE LEGEND IS COMPLETE WITH THE | | | EXTERIOR FIXTURES SUCH AS SITE/PARKING FIXTURES. (THIS | | | WATTAGE WAS SHOWN ON SITE PLAN.) | | | PLEASE BE SURE ALL FIXTURE WATTAGES AND NUMBER OF | | | FIXTURES MATCH. | | | PLEASE SEE FOR EXAMPLE: PLANS INDICATE A TOTAL OF | | | 73-64W FIXTURES, YET ONLY 58 -64 W FIXTURES ARE SHOWN | | | ON THE INPUT DATA REPORT. | | | PLEASE SEE THE 34 WATT FIXTURES ON THE INPUT DATA | | | REPORT ARE NOT LOCATED ON PLANS OR FIXTURE LEGEND. (ARE | | | THESE NOT 64W FIXTURES?) | | | PLEASE SEE FOR EXAMPLE: THE TOTAL NUMBER OF 32W | | | RECESSED LIGHTS ON PLANS IS AT 11 AND IDR SHOWS 9. | | | PLEASE SEE THE LIGHTING TOTAL SHOWN ON E2.1 IS HIGHER | | | THAN THE TOTAL ON THE IDR. EXAMPLE: PLANS 5408, IDR- | | | 4510. BOTH ARE LOW. | | | 13-415.1.A, 13-415.2, 13-415.2.ABC.1.1. .1.2. | | | | | | 2) NOTE: PLEASE SEE THE LIGHTING CONTROLS ARE STILL IN | | | QUESTION AS SHOWN. PLEASE SEE THE LIGHTING PLANS FOR | | | EXAMPLE SHOWS CORRIDOR LA-16 WHICH SHOWS A NOTE #2 | | | WHICH MENTIONS TO GO THROUGH LIGHTING CONTACTOR, YET | | | THE LIGHTING CONTACTOR DOES NOT SHOW LA-16 | | | PLEASE CLARIFY THE USE OF MANY OF THE LIGHTING CIRCUITS | | | IN SEPARATE SPACES WHICH GOES THROUGH THE LIGHTING | | | CONTACTOR SUCH LA-8, LA-36. HOW ARE THESE CONTROLLED BY | | | THE LIGHTING CONTACTOR YET THE DEVICES IN THE SPACE | | | DOES NOT SEEM TO BE OVER RIDE(S). PLEASE SEE | | | 13-415.1.ABC.1.2 WHICH REQUIRES SEPARATE SPACES TO | | | CONTAIN OVER RIDES. THE SO DEVICES IN OTHER LOCATIONS | | | ARE SHOWN AS OVER RIDES, HOWEVER THE SWS DOES NOT SEEM | | | TO SHOW THIS AS A OVER RIDE. | | | PLEASE CLARIFY. | | | 13-415.1.ABC.1.1 AND .1.2. | | | PLEASE SEE THE OWNER AGENT STILL NEEDS TO SIGN NEW | | | CALCULATIONS ONCE RESUBMITTED. | | | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEW COMMENT WITH | | | RESPECT TO FS 553.80(2)(B) AND REPEAT COMMENTS FOR CODE | | | COMPLIANCE. | | | PLEASE SEE THE SAME CODE SECTIONS ABOVE FOR CHAPTER 13 | | | APPLY FOR THE THIRD TIME. | | | PLEASE BE SURE TO GO OVER PLANS AND COORDINATE ALL. | | | PLEASE SEE THE FEE AS REQUIRED UNDER THE FLORIDA | | | STATUTES WAS ASSESSED AND IS DUE BEFORE PLANS MAY BE | | | RE-SUBMITTED. PLEASE KNOW THAT THE RE-SUB WILL NOT BE | | | DUE WHEN RE-SUBMITTING. | | | SHEETS E0.1, 2.1 AND 5.1 HAVE BEEN RETAINED ALONG WITH | | | ONE COPY OF THE ENERGY CALCULATIONS SUBMITTED. | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2008-01-03 13:53:18 | 2008-01-02 | | | | | | NEW ELECTRICAL AND LANDSCAPE SHEETS SUBMITTED. | | 2008-01-01 16:50:44 | 2008-01-01 16:50:44 | | | | | | PLANS IN ELECTRICAL FOR REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-30 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-29 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2007-10-30 09:55:49 | | | | ** DENIED 2ND REVIEW ** | | | | | | *** PLEASE SEE THERE ARE ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING. | | | PLEASE SEE THAT SOME OF THE EXACT SAME COMMENTS FROM | | | PREVIOUS REVIEW ARE BELOW. | | | PLEASE SEE NEW COMMENT BELOW. | | | | | | | | | 1) NOTE: PLEASE SEE LANDSCAPE PLANS AND FS 481.319 FOR | | | MISSING CERTIFICATE OF AUTHORIZATION NUMBER. | | | ** THIS IS BEING NOTED ** | | | | | | | | | 2) NOTE: PLEASE SEE COMMENT NUMBER 6 FROM PREVIOUS | | | REVIEW WHICH IS BEING ATTACHED BELOW AND LABELED AS | | | **PREVIOUS REVIEW NOTE **. | | | MANY OF THE SAME ITEMS FROM PREVIOUS REVIEW ARE THE | | | SAME. | | | PLEASE SEE THE LIGHTING CONTROLS ARE NOT COMPLETE AND | | | IN FACT THERE ARE SEVERAL LOCATIONS WHICH STILL | | | INDICATE A STANDARD SWITCH FOR CONTROL. | | | PLEASE SEE THE LIGHTING BEING CONTROLLED MUST BE SEEN | | | BY THE OCCUPANT WHICH IS CONTROLLING THE LIGHTING. | | | PLEASE SEE SHEET E2.1 WHICH CONTAINS A KEY NOTE #2 | | | WHICH MENTIONS TO SEE E0.1 FOR DETAIL, YET E0.1 DOES | | | NOT CONTAIN ANY DETAIL FOR ANY LIGHTING CONTROLS. | | | PLEASE SEE THE LIGHTING ON PLANS DOES NOT CORRELATE | | | WITH THE FIXTURE LEGEND FOR ALL FIXTURES AND DOES NOT | | | CORRELATE WITH THE INPUT DATA REPORT ON THE SUBMITTED | | | ENERGY CALCULATIONS. FOR EXAMPLE: SEE EXTERIOR LIGHTING | | | AS NONE ARE SHOWN ON FIXTURE LEGEND. FOR EXAMPLE: SEE | | | INTERIOR LIGHTING AS THE WATTAGES IS NOT THE SAME. FOR | | | EXAMPLE: COVER SHEET ON ENERGY CALCULATIONS STILL CALL | | | FOR THIS AS A *SHELL BUILDING*. HOW IS THIS POSSIBLE | | | WHEN PLANS DO NOT INDICATE A SHELL BUILDING??? | | | PLEASE BE SURE THE OWNER AGENT IS SIGNED ON | | | CERTIFICATION SHEETS. | | | PLEASE SEE THERE ARE SEVERAL ITEMS AS NOTED ABOVE FOR | | | EXAMPLE ALONG WITH MOST OF THE SAME COMMENTS BELOW FROM | | | PREVIOUS REVIEW WHICH NEED TO BE ADDRESSED. | | | | | | ** PREVIOUS REVIEW NOTE #6 *** | | | PLEASE SEE THE FOLLOWING NOTES FOR FBC CHAPTER 13. | | | PLEASE INDICATE LIGHTING CONTROLS PER | | | 13-415.1.ABC.1.1, .1.2. | | | PLANS INDICATE A TIME CLOCK HOWEVER LOCATIONS FOR ALL | | | OVER RIDES AS REQUIRED COULD NOT BE FOUND ON PLANS. | | | PLEASE SEE THERE IS SEPARATE SPACE CONTROL MISSING FOR | | | MANY AREAS. | | | PLEASE SEE NO TIME SCHEDULING WAS SUBMITTED. PLEASE SEE | | | NO MAXIMUM OVER RIDE TIMES WERE INDICATED (DEVICES NOT | | | SHOWN) | | | PLEASE BE SURE ALL DEVICES WHICH WILL BE IN DESIGN AND | | | ON PLANS ARE STATED ON LEGEND FOR DEVICES. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED DO NOT | | | CORRELATE WITH THE PLANS AND DESIGN. THESE INDICATE | | | BUILDING BEING A *SHELL* WHEN IN FACT THE BUILDING IS | | | BEING BUILT OUT AT THIS TIME. PLEASE ALSO SEE THE INPUT | | | DATA REPORT DOES NOT CORRELATE WITH PLANS. | | | PLEASE SEE THE TYPE OF FIXTURES. | | | PLEASE SEE THE NUMBER OF FIXTURES | | | PLEASE SEE THE WATTAGE OF FIXTURES. | | | PLEASE SEE NO EXTERIOR LIGHTING WAS INPUTTED IN THE IDR | | | WHEN THE PLANS CONTAIN EXTERIOR LIGHTS. | | | PLEASE BE SURE THE METHOD OF CONTROLS IS COORDINATED | | | WITH PLANS AND DESIGN FOR THE METHOD OF CONTROL. SHOWN | | | AS *MANUAL ON/OFF* WHICH IS NOT POSSIBLE AS THE PLANS | | | ARE REQUIRED AND CONTAIN AUTOMATED CONTROLS. | | | THERE ARE SEVERAL ITEMS ON THE CALCULATIONS WHICH NEED | | | TO BE ADDRESSED. | | | | | | PLEASE SEE MECHANICAL REVIEW COMMENTS WITH RESPECT TO | | | ENERGY CALCULATIONS. PLEASE BE SURE THE INPUT DATA | | | COORDINATES WITH THE PLANS. | | | PLEASE PROVIDE LIGHTING POWER PERFORMANCE CALCULATIONS | | | PER 13-415.2. | | | PLEASE KNOW AT THIS TIME NO REVIEW FOR LIGHTING | | | COMPLIANCE CAN BE DONE FOR INTERIOR AND EXTERIOR | | | LIGHTING POWER ALLOWANCES. PLEASE SEE 13-415.2, | | | 13-415.2.ABC.1.2, 13-415.2.ABC.1.3, 13-415.2.ABC.1.1 | | | | | | 3) NOTE: PLEASE SEE THIS COMMENT FROM PREVIOUS REVIEW | | | WILL REMAIN AS NOT ALL FIXTURES ON CALCULATIONS, | | | FIXTURE LEGEND AND PLANS ARE THE SAME. | | | FBC 106.1.2 FOR COORDINATION/ADDITIONAL INFORMATION. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE COMPLETE ALL FIXTURE DESIGNATIONS ON PLANS AND | | | CORRELATE WITH THE LEGEND. | | | PLEASE SEE SOME FIXTURES COULD NOT BE IDENTIFIED FOR | | | EMERGENCY USE ALTHOUGH THIS IS ONLY ASSUMED AT THIS | | | TIME DUE TO THE SHADING ON PLANS. | | | | | | 4) NOTE: PLEASE SEE DISCONNECTS LOCATED OUTSIDE FOR THE | | | CONDENSING UNITS DO NOT MEET 110.26 FOR MINIMUM WIDTHS | | | OR DEPTHS. THIS IS THE SAME COMMENT. BASED ON THE PLANS | | | AND SCALE ON SHEETS, THESE DO NOT MEET THE MINIMUM | | | 30X36 INCHES REQUIRED. | | | PLEASE ADJUST AND PLEASE BE SURE TO ADJUST OTHER SHEETS | | | FOR RELEVANT SET-BACKS AND DIMENSIONS. | | | | | | 5) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOE CODE COMPLIANCE. THIS IS ONLY A | | | NOTICE GIVEN AT THIS TIME. | | | ONE COPY OF ELECTRICAL PLANS AND ENERGY CALCULATIONS | | | HAVE BEEN RETAINED. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-10-29 16:38:33 | | | | | | | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-25 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-25 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2007-08-25 19:54:09 | 2007-08-25 19:54:09 | | | | | | *** DENIED *** | | | | | | ** PLEASE KNOW AS SOME INFORMATION WAS NOT YET | | | SUBMITTED A COMPLETE AND FULL REVIEW FOR SOME ITEMS | | | COULD NOT BE DONE. | | | | | | ** PLEASE SEE THERE ARE SEVERAL COMMENTS BELOW (2,3,4 | | | AND 5) WHICH DO NOT PERTAIN TO KAMM CONSULTING | | | ENGINEERING. | | | | | | 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH | | | ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | ** PLEASE KNOW THAT CHANGES FOR NEW CODES IS REQUIRED | | | FOR ALL TRADES AND FOR ALL REVIEWS EVEN IF COMMENT IS | | | NOT MADE BY OTHER TRADE(S). | | | | | | 2) NOTE: PLEASE SEE MISSING INFORMATION ON THE TITLE | | | BLOCKS FOR THE LANDSCAPE PLANS. | | | PLEASE SEE MISSING CERTIFICATE OF AUTHORIZATION NUMBER | | | AND INFORMATION AS REQUIRED PER 61G1-16.004. PLEASE SEE | | | FS 481.219 FOR REQUIRED MISSING CA #. | | | | | | 3) NOTE: PLEASE SEE ALL SHEETS OF THE SUBMITTED | | | LANDSCAPE PLANS ARE IN FACT *PHOTO-COPIES* OF SIGNED | | | AND SEALED PLANS. | | | PLEASE BE SURE TO SIGN, DATED AND SEALED PLANS WITH THE | | | REQUIRED RAISED SEAL AND ORIGINAL SIGNATURE. PLEASE SEE | | | FS 481.221, AND PLEASE SEE FAC 61G1-16.002 FOR CORRECT | | | SEAL AS REQUIRED. | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADE(S). | | | | | | 4) NOTE: PLEASE SEE THE CIVIL PLANS SUBMITTED ARE NOT | | | SIGNED, DATED AND SEALED AS REQUIRED PER FAC | | | 61G15-23.002, FS 471.025 | | | PLEASE ALSO SEE MISSING INFORMATION AS REQUIRED ON | | | TITLE BLOCKS ARE REQUIRED PER FAC 61G15-23.002. | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADE(S). | | | | | | 5) NOTE: PLEASE SEE MISSING INFORMATION ON THE TITLE | | | BLOCKS ON THE *S* SHEETS. | | | PLEASE SEE MISSING PRINTED NAME, PRINTED LICENSE NUMBER | | | AND MISSING CERTIFICATE OF AUTHORIZATION NUMBER AS | | | REQUIRED PER FAC 61G15-23.002, FS 471.023 | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADES. | | | | | | 6) NOTE: PLEASE SEE THE FOLLOWING NOTES FOR FBC CHAPTER | | | 13. | | | PLEASE INDICATE LIGHTING CONTROLS PER | | | 13-415.1.ABC.1.1, .1.2. | | | PLANS INDICATE A TIME CLOCK HOWEVER LOCATIONS FOR ALL | | | OVER RIDES AS REQUIRED COULD NOT BE FOUND ON PLANS. | | | PLEASE SEE THERE IS SEPARATE SPACE CONTROL MISSING FOR | | | MANY AREAS. | | | PLEASE SEE NO TIME SCHEDULING WAS SUBMITTED. PLEASE SEE | | | NO MAXIMUM OVER RIDE TIMES WERE INDICATED (DEVICES NOT | | | SHOWN) | | | PLEASE BE SURE ALL DEVICES WHICH WILL BE IN DESIGN AND | | | ON PLANS ARE STATED ON LEGEND FOR DEVICES. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED DO NOT | | | CORRELATE WITH THE PLANS AND DESIGN. THESE INDICATE | | | BUILDING BEING A *SHELL* WHEN IN FACT THE BUILDING IS | | | BEING BUILT OUT AT THIS TIME. PLEASE ALSO SEE THE INPUT | | | DATA REPORT DOES NOT CORRELATE WITH PLANS. | | | PLEASE SEE THE TYPE OF FIXTURES. | | | PLEASE SEE THE NUMBER OF FIXTURES | | | PLEASE SEE THE WATTAGE OF FIXTURES. | | | PLEASE SEE NO EXTERIOR LIGHTING WAS INPUTTED IN THE IDR | | | WHEN THE PLANS CONTAIN EXTERIOR LIGHTS. | | | PLEASE BE SURE THE METHOD OF CONTROLS IS COORDINATED | | | WITH PLANS AND DESIGN FOR THE METHOD OF CONTROL. SHOWN | | | AS *MANUAL ON/OFF* WHICH IS NOT POSSIBLE AS THE PLANS | | | ARE REQUIRED AND CONTAIN AUTOMATED CONTROLS. | | | THERE ARE SEVERAL ITEMS ON THE CALCULATIONS WHICH NEED | | | TO BE ADDRESSED. | | | | | | PLEASE SEE MECHANICAL REVIEW COMMENTS WITH RESPECT TO | | | ENERGY CALCULATIONS. PLEASE BE SURE THE INPUT DATA | | | COORDINATES WITH THE PLANS. | | | PLEASE PROVIDE LIGHTING POWER PERFORMANCE CALCULATIONS | | | PER 13-415.2. | | | PLEASE KNOW AT THIS TIME NO REVIEW FOR LIGHTING | | | COMPLIANCE CAN BE DONE FOR INTERIOR AND EXTERIOR | | | LIGHTING POWER ALLOWANCES. PLEASE SEE 13-415.2, | | | 13-415.2.ABC.1.2, 13-415.2.ABC.1.3, 13-415.2.ABC.1.1 | | | | | | 7) NOTE: PLEASE COMPLETE ALL FIXTURE DESIGNATIONS ON | | | PLANS AND CORRELATE WITH THE LEGEND. | | | PLEASE SEE SOME FIXTURES COULD NOT BE IDENTIFIED FOR | | | EMERGENCY USE ALTHOUGH THIS IS ONLY ASSUMED AT THIS | | | TIME DUE TO THE SHADING ON PLANS. | | | | | | 8) NOTE: PLEASE KNOW THAT THE PLANS NEED TO LABEL AND | | | PROVIDE ROOM AND AREA DESIGNATIONS ON PLANS AND | | | CORRELATE WITH THE PANEL SCHEDULES SHOWING ALL ROOMS | | | AND AREAS IN WHICH CIRCUITS FEED WILL BE REQUIRED FOR | | | EACH PANEL. PLEASE SEE THE USE OF *RECEPTACLES AND | | | LIGHTING * ON PANEL SCHEDULE DOES NOT PROVIDE THE | | | DETAILED INFORMATION NEEDED. | | | PLEASE KNOW THESE CAN BE ALPHA OR NUMERIC DESIGNATIONS | | | IF THIS HELPS TO ALLEVIATE CONGESTION ON PLANS.PLEASE | | | SEE TEXT WHICH IS TAKEN FROM COMMENTARY IN THE CODE | | | WHICH STATES THE USE OF *GEN LT* ETC IS NOT | | | ACCEPTABLE. | | | | | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | | SECTION.* | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 9) NOTE: PLEASE SEE THE ARCHITECTURAL SHEETS INDICATES | | | THE FPL TRANSFORMER IN ONE LOCATION AT THE REAR OF THE | | | PROPERTY AND THE ELECTRICAL PLANS INDICATES THIS SAME | | | TRANSFORMER AT THE FRONT ENTRANCE. | | | THIS LOCATION CONTAINS THE FPL POLES AT THE REAR OF | | | PROPERTY. PLEASE COORDINATE AND ADJUST PLANS. | | | FBC 106.1.2 | | | | | | 10) NOTE: PLEASE SEE MISSING SIGN CIRCUIT REQUIRED AT | | | THE FRONT ENTRANCE PER 600.5. | | | PLEASE BE SURE TO ADJUST THE CALCULATIONS TO THE | | | MINIMUM LOAD OF 1200 VA. | | | | | | 11) NOTE: PLEASE CLARIFY THE REQUIRED DISCONNECTING | | | MEANS FOR AIR HANDLER UNITS INSIDE BUILDING PER | | | 440.11. | | | | | | 12) NOTE: PLEASE SEE DISCONNECTS LOCATED OUTSIDE FOR | | | THE CONDENSING UNITS DO NOT MEET 110.26 FOR MINIMUM | | | WIDTHS OR DEPTHS. | | | PLEASE ADJUST. | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-11-15 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-11-15 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-08-30 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-08-30 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2007-08-30 14:34:31 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FROM | | | 1000, 45 STREET FOR ALL THESE CITY STANDARDS NOTES. | | | PHONE# 494-1040 | | | 3. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 4. FLOOR ELEVATION, CENTER LINE OF ROAD , SIDEWALK | | | ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, 25, 100 | | | YEAR FLOOD CRITERIATO DETERMINE THE FLOOR ELEVATION, | | | PLEASE SHOW IN YOUR STORM WATER CALS. | | | 5. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE | | | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL | | | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, | | | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE | | | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED | | | IN PRE & POST STORM WATER QUALITY CALCULATIONS. | | | 6. HOW DO YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR | | | SITE SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES | | | FROM ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF | | | THE CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, | | | BLEEDING ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS. | | | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | 8. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, &STORM | | | WATER QUALITY CALCULATIONS, | | | 9. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT | | | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE | | | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & | | | PARTICLES. | | | 10. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-20 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-20 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2008-05-20 13:45:17 | *****REVISION , DATED 4/18,22/08, APPROVED****** | | | | | | | | | REVISED PLAN SHEETS A201, A-350, E2.1, AND FA2.1 WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2007-11-14 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2007-11-14 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2007-11-14 16:35:21 | 1. SEPARATE PLANS AND PERMITS REQUIRED FOR THE | | | INSTALLATION OF THE FIRE ALARM SYSTEM DISPLAYED ON THE | | | PLANS. | | | | | | 2. A MANUAL PULL STATION APPEARS TO BE NEEDED ON THE | | | REAR EXIT DOOR LOCATED IN THE WORK AREA 120 AS THERE | | | APPEARS TO BE ONLY ONE INITIATING APPLIANCE TO ACTIVATE | | | THE SYSTEM, MANUAL PULL STATION LOCATED IN THE LOBBY. | | | ANOTHER PULL STATION WAS OBSERVED ON PAGE FA2.1. PLEASE | | | CORRECT DRAWINGS SO THEY MATCH. LS PLAN AND FA2.1. | | | | | | 3. INTERIOR FINISH CLASSIFICATIONS FOR WALLS AND | | | CEILINGS IN THE MEANS OF EGRESS SHALL BE CLASS A SINCE | | | THE BUILDING IS NOT FIRE SPRINKLER PROTECTED. | | | | | | 4. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL BY | | | CITY INSPECTORS. | | | | | | APPROVED PROVISO: | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-25 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-25 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2007-09-25 15:41:58 | *****DENIED***** | | | | | | | | | 01.THE NUMERICAL ADDRESS SHALL BE IN THE TITLE BLOCK | | | OF EACH SUBMITTED PLAN SHEET. | | | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.THE SCOPE OF WORK SHALL IN NO WAY INTERFERE OR | | | HINDER EMERGENCY ACCESS TO THE PROPERTY OR VICINITY | | | THEREOF (INCLUDING STREETS, ALLEYS, FIRE LANES). | | | | | | 04.PLEASE INCLUDE EXIT LIGHTS AND FIRE EXTINGUISHERS | | | ON THE FLOOR PLAN (A-201). | | | | | | 05.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | | INSTALLATION OF THE FIRE ALARM SYSTEM. | | | | | | 06.IT IS INDICATED THAT THE BUILDING WILL BE EQUIPPED | | | WITH A KNOX BOX;FOR APPLICATIONS CONTACT WEST PALM | | | BEACH FIRE PREVENTION BUREAU AT 561-804-4724. | | | | | | 07.ON THE APPROPIATE EXTERIOR ELEVATION WHICH FRONTS | | | SOUTHERN BOULEVARD, SHOW THE ADDRESS NUMBERS ON THE | | | BUILDING.AS PER WEST PALM BEACH CODE, THE NUMBERS | | | SHALL BE NO LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" | | | IN WIDTH. | | | | | | 08.ON SHEET FA0.1 AMEND FIRE ALARM NOTE #17 AS SUCH: | | | DELETE "SUPERVISORY SIGNAL ONLY"-INSERT "GENERAL | | | FIRE ALARM".AS PER LOCAL REQUIREMENTS, DUCT SMOKE | | | DETECTORS SHALL INITIATE A GENARAL FIRE ALARM. | | | | | | 09.ON SHEET A-901, ADD TO DOOR REMARKS AS NOTE 6:A | | | DOOR NORMALLY REQUIRED TO BE KEPT CLOSED SHALL NOT BE | | | SECURED IN THE OPEN POSITION AT ANY TIME AND SHALL BE | | | SELF CLOSING OR AUTOMATIC CLOSING IN ACCORDANCE WITH | | | 7.2.1.8.2 OF NFPA 101 - 2003 EDITION. | | | | | | 10. ON SHEET A-901,PLEASE EXPLAIN DOOR REMARK #2 IN | | | REFERENCE TO DOORS 124 AND 125 AS LOCATED ON A-201. | | | WILL A PERSON OR PERSONS BE ABLE TO EGRESS FROM THESE | | | AREA ONCE INSIDE WITHOUT A KEY, A TOOL, OR SPECIAL | | | KNOWLEDGE? | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH COMMENT | | | WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-15 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-15 |
Time |
09:31 |
Sent To |
M |
|
| Notes |
| 2008-07-15 09:31:59 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-01 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-01 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2008-05-01 10:43:23 | TO "COMM" BD#24 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-30 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-30 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2008-01-30 10:12:14 | TO "COMM" BD#1/PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-27 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-27 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2007-12-27 10:24:56 | TO COMM BOARD # 48 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-10 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-10 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2007-10-29 08:23:42 | TO "COMM" BD#48 | | 2007-10-10 09:03:51 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-25 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-02 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2007-08-23 13:06:37 | TO "COMM" BD#37 | | 2007-08-02 15:25:47 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-09-24 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-09-24 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-04 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-04 |
Time |
16:33 |
Sent To |
PC |
|
| Notes |
| 2008-08-04 16:50:29 | REVISION 7 PAGES M0.1 AND M2.1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-19 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-16 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2008-05-19 08:44:00 | REV.6 PG M2.1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-15 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-15 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2007-11-15 17:36:07 | PASSED PENDING ACCEPTANCE OF ENERGY CALCULATIONS BY | | | OTHER INTERESTED TRADES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-24 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-24 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2007-08-24 17:22:38 | REVIEW #: 1 | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. M0.1 MECH NOTES #12: THERMOSTATIC CONTROLS SHALL | | | COMPLY WITH FBC 13-407.1.ABC.2.4.1. | | | | | | 2. M0.1 AIR BALANCE SCHEDULE: AHU #5 IS MISSING FROM | | | THE SCHEDULE. PLEASE CORRECT AND RESUBMIT. | | | | | | 3. M0.1 FAN SCHEDULE: CONTROLS INDICATE "LIGHT | | | INTERLOCK." PROVISIONS SHALL ALSO BE MADE TO INTERLOCK | | | FANS WITH AHU #4 TO ASSURE THAT ALL AIR SUPPLIED TO THE | | | TOILET ROOMS IS EXHAUSTED AND NOT RECIRCULATED IN | | | ACCORDANCE WITH FBC,M 403.2.1(3). | | | | | | 4. M2.1: AHU #4 ON FLOOR PLAN SHOWS 1330 CFM WHILE AHU | | | #5 SHOWS 1050 CFM. EQUIPMENT SCHEDULE CALLS FOR 1200 | | | CFM EACH. PERHAPS ONE OR MORE DROPS IS ATTACHED TO THE | | | WRONG SYSTEM. SHOW AN AIR BALANCE WHICH IS IN | | | CONJUNCTION WITH EQUIPMENT SCHEDULE. | | | | | | 5. M5.1: DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE | | | BUILDING FIRE ALARM SYSTEM PER FBC,M 606.4.1. | | | | | | 6. M5.1: LOUVER DETAIL INDICATES A MIAMI-DADE NOA WHICH | | | HAS EXPIRED. PROVIDE AN UPDATED FLORIDA PRODUCT | | | APPROVAL OR NOA SUBMITTAL. | | | | | | 7. M5.1: AHU DETAIL SHOWS LOUVERED DOORS BUT FLOOR PLAN | | | SHOWS SOLID DOORS WITH WALL GRILL. PLEASE COORDINATE | | | PLANS. | | | | | | 8. ENERGY CALCULATIONS: THIS SPACE IS NOT COOLED BY ONE | | | SYSTEM OF 240,000 TO 760,000 BTU/H COOLING CAPACITY. | | | ADJUST CALCULATIONS TO ACCURATELY REFLECT THE EQUIPMENT | | | BEING USED AND THE MINIMUM EFFICIENCY RATING REQUIRED. | | | EXAMPLE: FOR EQUIPMENT <65,000 BTU/H THE EFFICIENCY | | | CRITERIA IS 13.00 NOT 9.50 AS STATED ON CALCULATIONS | | | SYSTEM REPORT. | | | | | | 9. ROOF TYPE ON INPUT DATA REPORT SHOWS A METAL | | | BUILDING ROOF WITH R-19 BATTS. THIS IS NOT A METAL | | | BUILDING AND THERE ARE NO BATTS AT THE ROOF. PLEASE | | | CORRECT TO ACCURATELY REFLECT THE SYSTEM BEING USED ON | | | THIS BUILDING AND RESUBMIT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-01 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-01 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2008-05-01 16:40:18 | REVISION SHEETS A-201 & A-350: NO PLUMBING CHANGES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-01-07 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-01-07 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-04 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-04 |
Time |
06:29 |
Sent To |
PC |
|
| Notes |
| 2007-12-04 08:00:34 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS | | | TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE STILL | | | REQUIRED FOR PLUMBING PLAN REVIEW TO MEET CODE | | | COMPLIANCE ON THE RESUBMITTED PLANS: | | | | | | 1. OK, COMMENT ADDRESSED. | | | | | | 2. OK, COMMENT ADDRESSED. | | | | | | 3. OK, COMMENT ADDRESSED. | | | | | | 4. SHEET A-901 ROOM FINISH SCHEDULE: ROOMS 114, 115 & | | | 118. THE WALLS WITH IN 2 FEET OF A WATER CLOSET SHALL | | | HAVE A SMOOTH, HARD, NONABSORBANT SURFACE UP TO 4 FEET. | | | PER SECTION *1210.2. | | | | | | **NOTE: RESUBMITTED FINISH SCHEDULE ON THIS SHEET ARE | | | NOW INDICATING EPOXY PAINT ON DRYWALL. PLEASE REFERENCE | | | BUILDING PLAN REVIEWERS COMMENT #15 THAT EPOXY PAINT ON | | | DRYWALL HAS NOT BEEN ESTABLISHED AS A NON-ABSORBANT | | | MATERIAL SINCE IT CAN GET NICKS IN THE SURFACE THROUGH | | | OUT THE LIFE TIME OF THE INSTALLATION AND COMPLY PER | | | SECTION *1210.2 WALLS. | | | | | | 5. OK, COMMENT ADDRESSED. | | | | | | 6. SHEETS L1 THRU L4 SHALL BE SIGNED, SEALED WITH AN | | | EMBOSSED SEAL AND DATED AS REQUIRED IN SECTION 106.1. | | | ALSO THE FIRM LICENSE NUMBER IS REQUIRED IN THE TITLE | | | BLOCK. FAC 61G15-23.002(2) & FS 417.025. PLEASE SHOW | | | THE THE PRINTED NAME OF THE ENGINEER SEALING THE | | | DOCUMENT AS WELL AS THE CA# ON EACH SHEET. | | | | | | **NOTE: THE RESUBMITTED SHEETS ARE MISSING THE PRINTED | | | NAME AND LICENSE NUMBER OF THE PERSON SEALING THE | | | SHEETS AS WELL AS THE CERTIFICATE OF AUTHORIZATION | | | NUMBER OF THE FIRM. | | | | | | 7. SHEET P0.1 WATER RISER DIAGRAM THE WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS SHOWN. PDI-WH | | | 201 AND MANUF. INSTALLATION INSTRUCTIONS. PLEASE LOCATE | | | THE WHA'S AS REQUIRED. | | | | | | **NOTE: THE RESUBMITTED WATER RISER DIAGRAM IS LOCATING | | | THE WATER HAMMER ARRESTOR FOR THE SINK IN BREAK ROOM | | | 113 WRONG. PLEASE LOCATE THE WATER HAMMER ARRESTORS AS | | | REQUIRED. | | | | | | 8. SEPERATE IRRIGATION PLANS & PERMIT REQUIRED PRIOR | | | TO C. O. SECTION 106.3.5.1.3(9). | | | | | | *****THE FOLLOWING ARE NEW COMMENTS***** | | | | | | 9. NOTE, THE ADDED RESTROOM #118 ON SHEET A-201 TO | | | MEET THE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES: | | | THE REQUIRED PLUMBING FOR THIS REST ROOM NEEDS TO BE | | | ADDED TO SHEETS P0.1 DOMESTIC WATER AND SANITARY RISER | | | DIAGRAMS AS WELL AS TO SHEET SHEET P2.1 PLUMBING PLANS. | | | PLEASE COMPLY ON THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-15 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-15 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2007-09-15 17:44:42 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHTS CS-1 AND ALL ARCHITECTUAL SHEETS. THE PRINTED | | | NAME OF THE PERSON SEALING THE DOCUMENT SHALL BE IN THE | | | TITLE BLOCK OF EACH SHEET. FAC 61G1-16.004(6) & FS | | | 481.2055. PLEASE INDICATE THE PRINTED NAME. | | | | | | 2. SHT 1 OF 1, (DCES), SHALL BE SIGNED, SEALED AND | | | DATED PER SECTION 106.1. | | | | | | 3. SHT A-201 PER TABLE 403.1 THREE WATER CLOSETS AND | | | THREE LAVS ARE REQUIRED FOR THE BUSINESS OCCUPANCY AT | | | 7260SF. ONLY 2 W/C'S AND 2 LAVS WERE PROVIDED. PLEASE | | | SHOW COMPLIANCE WITH TABLE 403.1 REQUIEMENT. | | | | | | 4. SHT A-901 ROOM FINISH SCHEDULE. ROOMS 114 & 115. THE | | | WALLS WITH IN 2 FEET OF A WATER CLOSET SHALL HAVE A | | | SMOOTH, HARD, NONABSORBENT SURFACE UP TO 4 FEET. THE | | | SCHEDULE INDICATES PAINTED GWB. PAINTED SURFACES DOES | | | NOT COMPLY WITH THE REQUIREMENT FOR A HARD SURFACE. | | | PLEASE SHOW COMPLIANCE WITH SECTION 1210.2. | | | | | | 5. SHTS S-01 THRU S-06. ENGINEER SHALL LEGIBLY INDICATE | | | THEIR NAME ON EACH SHEET. ALSO THE CERTIFICATE OF | | | AUTHORIZATION IS REQUIRED IN THE TITLE BLOCK OF EACH | | | SHEET. FAC 61G15-23.002(2) & FS 471.025. PLEASE SHOW | | | THE PRINTED NAME OF THE ENGINEERING SEALING THE | | | DOCUMENT AS WELL AS THE CA# ON EACH SHEET. | | | | | | 6. SHTS L1 THRU L4 SHALL BE SIGNED, SEALED WITH AN | | | EMBOSSED SEAL AND DATED AS REQUIRED IN SECTION 106.1. | | | ALSO THE FIRM LICENSE NUMBER IS REQUIRED IN THE TITLE | | | BLOCK. FAC 61G1-16.004(2)(5) & FS 481.2055. PLEASE | | | SIGN, SEAL & DATE EACH SHEET AND INDICATE THE FIRM | | | LICENSE NUMBER AS WELL. | | | | | | 7. SHT P0.1 WATER RISER DIAGRAM. THE WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS SHOWN. PDI-WH | | | 201 AND MANUF. INSTALLATION INSTRUCTIONS. PLEASE LOCATE | | | THE WHA'S AS REQUIRED. | | | | | | 8. SEPARATE IRRIGATION PLANS & PERMIT REQUIRED PRIOR TO | | | C.O. SECTION 106.3.5.1.3(9). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-12-28 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-12-28 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2007-12-28 11:40:43 | PLANNING AND ZONING DEPARTMENT | | | | | | PROVISO WHEEL STOPS SHALL BE 2 FEET FROM THE CURB TO | | | THE BACK OF THE WHEEL STOP.HANDICAP SYMBOL SHALL BE 3 | | | FEET OR 5 FEET HIGH AND WHITE IN COLOR.HANDICAP | | | SYMBOL SHALL BE 2 FEET FROM THE OPEN END OF THE PARKING | | | SPACE. | | | | | | PROVISO ALL ELECTRICAL CONDUIT SHALL RUN AROUND AND | | | AWAY FROM ANY ROOT BALLS.LIGHT POLES ARE TO BE 2 FEET | | | FROM THE TERMINATING POINTS OF THE ISLANDS. | | | | | | PROVISO LANDSCAPE PLANS SHALL BE SEALED PRIOR TO | | | OBTAINING C.O.SIGNED AND SEALED COPIES SHALL BE | | | SUBMITTED TO THE CITY.PER ANGELLA VANN, DEPUTY | | | PLANNING DIRECTOR. | | | | | | ALL PROVISOS SHALL BE MET PRIOR TO OBTAINING C.O. | | | | | | SEE SPECIFIC SHEETS FOR EACH PROVISO. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-10-22 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-10-22 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2007-10-22 16:06:01 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PLANS SHALL BE REVISED TO SHOW CONDITIONS PER THE | | | SITE PLAN APPROVAL LETTER. | | | | | | 2. PARKING STALL DETAILS IN SHEET C-3 OF 4, ?PAVING, | | | GRADING AND DRAINAGE DETAILS,? SHALL MATCH THE PARKING | | | STALL DETAILS PER THE APPROVED SITE PLANS. | | | | | | 3. PLEASE NOTE THAT ALL PLANS SHALL SHOW SAME | | | CONDITIONS. | | | | | | 4. PLEASE SUBMIT (2) COPIES OF A SIGNED AND SEALED | | | SURVEY. | | | | | | 5. AN IRRIGATION PLAN SHALL BE SUBMITTED WITH THE | | | IRRIGATION PERMIT. | | | | | | COMMENT/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-08-09 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-08-09 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2007-08-09 09:06:46 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1.PLANS REQUIRE SITE PLAN APPROVAL FROM THE PLANNING | | | AND ZONING DEPARTMENT PRIOR TO BUILDING PERMIT | | | APPROVAL.PLEASE NOTE THAT ALL PPRC COMMENTS SHALL BE | | | ADDRESSED PRIOR TO SITE PLAN APPROVAL. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
|