Plan Review Details - Permit 07071009
Plan Review Stops For Permit 07071009
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2007-11-16 Cont ID  
Sent By lursu Date 2007-11-16 Time 12:06 Rev Time 0.00
Received By lursu Date 2007-11-16 Time 12:06 Sent To  
Notes
2007-11-16 12:08:56WORK IS DONE ON THE OVERALL STRUCTURE.SITE ADDRESS
 CORRECT.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2007-11-09 Cont ID  
Sent By lursu Date 2007-11-09 Time 13:28 Rev Time 0.00
Received By lursu Date 2007-11-09 Time 13:28 Sent To  
Notes
2007-11-09 13:29:14PLEASE INDICATE THE SUITE NUMBER OF THE JOB LOCATION.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-10-17 Cont ID  
Sent By shill Date 2008-10-17 Time 13:23 Rev Time 0.00
Received By shill Date 2008-10-17 Time 13:23 Sent To  
Notes
2008-10-17 13:27:02REVISION SHEETS COVER, A6, A6.1, A7, SD1, SD2, SD3
 DATED 7/11/08
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2008-08-20 Cont ID  
Sent By shill Date 2008-08-20 Time 13:44 Rev Time 0.00
Received By shill Date 2008-08-20 Time 13:44 Sent To  
Notes
2008-08-20 13:47:54****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.SEE MECHANICAL COMMENTS REGARDING FIRE DAMPERS,
 FBC712.
  
 2.THE STRUCTURAL CALCULATIONS ARE TO BE IN ACCORDANCE
 WITH FAC61G15-23.002 (TITLE BLOCK, SIGNED AND SEALED
 EACH SHEET).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-06-13 Cont ID  
Sent By shill Date 2008-06-13 Time 13:06 Rev Time 0.00
Received By shill Date 2008-06-13 Time 13:06 Sent To  
Notes
2008-06-13 13:12:26****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.CHANGES ARE NOT SHOWN ON THE PLAN.PLEASE CLOUD
 ALL CHANGES AND INDICATE WITH A REVISION NUMBER.IF
 THE ENTIRE FLOOR PLAN HAS CHANGED, A TRANSMITTAL LETTER
 WOULD BE HELPFUL.
  
 2.THE GRAPHIC FOR THE WALL, SHOWN IN RED OR BLUE WITH
 A SMALL DIAGONAL WHITE LINE ON A6 AT ROOMS 91, 92, 93,
 ETC. IS NOT ON THE WALL LEGEND.THIS APPEARS TO BE A 1
 HOUR CORRIDOR BASED ON OTHER INFORMATION ON THE PLAN.
 PLEASE REVISE AND ALSO NOTE THAT OUR SCANNING IS NOT IN
 COLOR, SO THAT ASPECT OF THE PLAN WILL NOT BE RETAINED
 FOR RECORD KEEPING PURPOSES.COLOR MAY BE USED TO
 ASSIST WITH PLAN REVIEW, BUT GRAPHICS MUST BE UNIQUE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-01-18 Cont ID  
Sent By shill Date 2008-01-18 Time 13:10 Rev Time 0.00
Received By shill Date 2008-01-18 Time 13:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-12-05 Cont ID  
Sent By shill Date 2007-12-05 Time 09:19 Rev Time 0.00
Received By shill Date 2007-12-05 Time 09:19 Sent To  
Notes
2007-12-05 09:30:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.SEE ELECTRIC COMMENTS REGARDING ENERGY CALCS.
 BUILDING REVIEW OF ENERGY CALCS IS REQUIRED.PLEASE
 NOTE THAT THE SQUARE FOOT AREA ON THE ENERGY CALCS IS
 TO CORRELATE WITH THE PLANS (MOST COMMON BUILDING
 COMMENT REGARDING ENERGY CALCS).IF THE SQUARE FOOT
 AREA DIFFERS, PLEASE PROVIDE AN EXPLANATION.
  
 2.SEE OTHER REVIEWERS' COMMENTS REGARDING THE
 ARCHITECT INFORMATION ON THE PLAN.PLEASE ADDRESS.
  
 3.NEW COMMENT - FIVE ACCESSIBLE PARKING SPACES
 REQUIRED, ONLY FOUR SHOWN.SEE FBC11-4.1.2(5)(A).IN
 BUILDINGS WITH MULTIPLE ENTRANCES WITH ADJACENT PARKING
 (EXITS MAY ALSO BE REQUIRED TO BE ENTRANCES, NOT ONLY
 THE MAIN ENTRANCE), ACCESSIBLE PARKING SPACES SHALL BE
 DISPERSED AND LOCATED CLOSEST TO THE ACCESSIBLE
 ENTRANCES.THIS MAY BE A PROVISO ITEM IF REQUESTED.
 PLEASE CONTACT ME IF YOU NEED MORE INFORMATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-09-12 Cont ID  
Sent By kconrad Date 2007-09-12 Time 18:39 Rev Time 0.00
Received By kconrad Date 2007-09-12 Time 17:22 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2008-08-01 Cont ID  
Sent By dpalmer Date 2008-08-01 Time 09:03 Rev Time 0.00
Received By dpalmer Date 2008-08-01 Time 09:03 Sent To  
Notes
2008-08-01 09:06:408/1/08 VALUE FROM 5/31 WHICH WAS $70K IS NOW NOTED ON
 REVISION COVER SHEET AS $124K. THE DIFFERENCE OF
 124,000 AND 70,000 IS 54,000. THE APPLIED TOTAL VALUE
 FOR SCOPE OF WORK HAS NOW INCREASED BY THE ADDITIONAL
 $54K BRINGING THE TOTAL FOR APPLIED VALUE TO $344,000.
 THEFEE OF $ WILL BE DUE WHEN PICKING UP PLANS. DV
 PALMER.

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2008-06-20 Cont ID  
Sent By dpalmer Date 2008-06-20 Time 10:34 Rev Time 0.00
Received By dpalmer Date 2008-06-20 Time 10:34 Sent To  
Notes
2008-06-20 10:34:12** DENIEDREVIEW OF REVISIONS **
  
  
 1) NOTE: PLEASE SUBMIT COMPLETE ELECTRICAL PLANS.
 MECHANICAL PLANS NOW INDICATE ALL NEW ROOF TOP SYSTEMS
 YET NO ELECTRICAL REVISIONS ARE SHOWN FOR DISCONNECTS,
 ROOF TOP SERVICE GFI RECEPTACLES ETC.
 REVISE PANEL SCHEDULES, LOAD CALCULATIONS, CIRCUITING
 ETC.
 SOME SHEETS ARE BEING SUBMITTED AS REVISED YET NO
 REVISIONS ARE SHOWN.
  
 FBC 106.3.5.1.2
 NEC 2005
 440.11, 210.63, 210.8B, 240.4, 310.16 ETC.
  
  
 2) NOTE: PLEASE KNOW EVEN AS VALUE WAS INCREASED THE
 AMOUNT OF INCREASE BASED ON INCREASE OF SCOPE IS LOW.
 THE VALUE IS REQUIRED TO INCLUDE COST OF EQUIPMENT,
 ELECTRICAL, DESIGN, CRANES, ROOFING ETC. PLEASE SUBMIT
 REVISED CONTRACTS TO VERY ALL SCOPE OF WORK FOR PROJECT
 OR ADJUST VALUE. FBC 108.3
 THIS IS REQUIRED EVEN IF ANY EQUIPMENT, ETC IS OWNER
 SUPPLIED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF
 THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2008-02-16 Cont ID  
Sent By dpalmer Date 2008-02-16 Time 18:33 Rev Time 0.00
Received By dpalmer Date 2008-02-16 Time 18:33 Sent To B
Notes
2008-02-16 18:34:112008-02-16 18:34:11
  
 PLANS STAMPED FOR ELECTRICAL OK.
 ROUTED PLANS TO SH'S DESK FOR PROCESSING. LEFT NOT ON
 PLANS FOR WHAT IS NEEDED BEFORE PERMIT CAN BE ISSUED.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2008-02-08 Cont ID  
Sent By dpalmer Date 2008-02-08 Time 20:06 Rev Time 0.00
Received By dpalmer Date 2008-02-08 Time 18:48 Sent To  
Notes
2008-02-08 20:06:402008-02-08 20:06:40
  
 *** DENIED 4RD REVIEW ***
  
 ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEWS ARE
 STILL IN NEED OF ADDRESSING. SOME OF THESE ITEMS COULD
 BE REDLINED HOWEVER NOT ALL.
 PLEASE SEE NOTES BELOW.
  
 ** PLEASE SEE NOTES FROM TWO PREVIOUS REVIEWS WITH
 RESPECT TO LIGHTING CONTROLS REQUIRED PER FBC
 13-415.1.ABC.1.1 AND .1.2.
 THE PLANS WERE REVISED TO INDICATE THAT THE DEVICES IN
 EACH ROOM ARE NOW A DEVICE WHICH CONTAINS A TIMER FOR A
 MAXIMUM OF FOUR HOURS AND IS NOT PART OF ANY LIGHTING
 CONTROL SYSTEM.
 PLEASE SEE THE TS-400 IS A DEVICE WITH A MAXIMUM TIME
 OF 12HRS AS STATED ON THE WATTSTOPPER WEBSITE. PLEASE
 SEE 13-415.1.ABC.1.2 WHICH REQUIRES SPACES SUCH AS
 CLASSROOMS, EMPLOYEE LUNCH/BREAK ROOMS AND CONFERENCE
 ROOMS TO CONTAIN DEVICES WHICH DOES NOT PERMIT THE
 LIGHTING TO REMAIN ON FOR MORE THAN 30MINS AFTER THE
 LAST OCCUPANT HAS VACATED THE ROOM. THE TIMER AS NOTED
 DOES NOT MEET THE 30MINS FOR THESE ROOMS. THESE FEW
 ROOMS COULD BE RED-LINED HOWEVER PLEASE STILL SEE
 13-415.1.ABC.1.1 WHICH NO LIGHTING CONTROLS COULD BE
 LOCATED FOR THE COMMON HALLWAY AREAS.
 THE FRONT LOBBY ENTRANCE AREAS DO SHOW SOME OF THESE SA
 DEVICES WHICH ARE NOTED AS 4HR TIMERS PERNOTE ON E-4
 HOWEVER THE OTHER AREAS DO NOT SHOW ANYTHING BUT
 STANDARD S3 AND S4 FOR THREE-WAY AND FOUR-WAY
 SWITCHES.
 ** PLEASE SEE THE CODE SECTIONS GIVEN AND ADJUST
 PLANS.
  
 2) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO
 LIGHTING POWER CALCULATIONS. PLEASE SEE 13-415.2 PLEASE
 SEE THE TABLE WHICH HAS BEEN ADJUSTED. PLEASE SEE THE
 FIXTURE COUNT FOR TYPE B SHOWS 45, YET PLANS CONTAIN
 47.
 PLEASE SEE THE MAIN CONCERN IS THE TYPE A FIXTURES.
 SHOWS 3-28W T5 WHICH BY THE FIXTURE LEGEND AND THE
 CALCULATION TABLES INDICATES THESE AS 75W FIXTURES?
 THIS IS UNCLEAR HOW THIS IS POSSIBLE. A SEARCH BASED ON
 THE METALUX FIXTURES ON COOPER LIGHTING WEBSITE DOES
 NOT COORDINATE WITH THE SAME TYPE OF AC FIXTURES AS
 NOTED. PLEASE SEE MANY FIXTURES INDICATE FIXTURES WITH
 BALLAST WITH AVAILABLE *POWER FACTORS* WHICH WOULD
 ADJUST ACTUAL USE INSTEAD OF BEING BASED ON THE BULB
 WATTAGE.
 COULD NOT LOCATE THE FIXTURE, BALLAST, ETC WHICH IS THE
 TYPE AS LISTED ON LEGEND. PLEASE SUBMIT THE
 MANUFACTURES SPEC/CUT SHEET OR E-MAIL THE SPECS, OR
 WEB-SITE LINK WHICH SHOWS THESE FIXTURES. THE SITE
 SPECS FOR THIS TYPE METALUX 2AC AS LISTED ARE ATTACHED
 TO NOTES WHICH INDICATE A 2 LAMP FIXTURE.
 PLEASE SEE ATTACHED SHEETS FOR THE TROFFER RECESSED
 LIGHTS AS STATED ON LEGEND.
 RESPONSE LETTER MENTIONS FIXTURES CONTAIN A HIGH-POWER
 FACTOR WHICH IS FINE HOWEVER COULD NOT LOCATE THE SAME
 POWER FACTOR ON THIS FIXTURE WHICH COORDINATES WITH THE
 75WATTS.
  
  
 ** AS STATED ON PREVIOUS REVIEW, PLEASE GO OVER ALL
 FIXTURES ON PLANS, FIGURE WATTS PER SQUARE FEET BASED
 ON THE NUMBER OF FIXTURES AND THE RATING OF FIXTURE
 OUTPUT.
  
 IF THERE ARE ANY QUESTIONS ON THE ABOVE NOTED ITEMS,
 PLEASE CONTACT THIS OFFICE AT THE CONTACT INFORMATION
 BELOW.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-12-25 Cont ID  
Sent By dpalmer Date 2007-12-25 Time 12:06 Rev Time 0.00
Received By dpalmer Date 2007-12-25 Time 12:06 Sent To  
Notes
2007-12-25 12:07:092007-12-25 12:07:09
  
 ** DENIED 3RD REVIEW **
  
 ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING.
  
  
 1) NOTE: PLEASE SEE NOTE #2 FROM PREVIOUS REVIEW. PLANS
 INDICATE A TIMER OVER RIDE DEVICE WHICH LENDS TO SOME
 SORT OF SYSTEM BEING INSTALLED HOWEVER THE PLANS DO NOT
 PROVIDE ANY SYSTEM.A TIMER OVER RIDE IS FOR OVER
 RIDING SOME SORT OF LIGHTING CONTROL SYSTEM.
 NO DETAILS FOR ANY TYPE OF LIGHTING CONTROL PANEL WAS
 SUBMITTED, NO PANELS, NO SCHEDULING ETC.
 PLEASE COMPLETE AND SUBMIT.
  
 2) NOTE: PLEASE SEE THE LIGHTING PERFORMANCE
 CALCULATIONS ARE NOW SUBMITTED. PLEASE SEE THE METHOD
 IS NOT STATED HOWEVER IT IS BEING ASSUMED THIS IS FROM
 TABLE *C*.
 PLEASE SEE THE CALCULATIONS NEED TO BE EXPANDED UPON.
 WHAT SQ FT IS BEING FIGURED AND FOR WHAT SPACE? DOES
 THIS INCLUDE ONLY NEW AREA WHERE WORK IS BEING DONE?
 MAY NOT USE THE EXISTING AREAS (SQ FT) NOT BEING DONE
 WITH NEW LIGHTING.
 PLEASE ALSO SEE THE WATTAGE PER FIXTURE WHICH IS
 REQUIRED TO BE USED SHALL BE BASED ON THE MAXIMUM
 FIXTURE WATTAGE FOR INCANDESCENT AND MAXIMUM VALUE FOR
 FIXTURES WITH PERMANENTLY INSTALLED BALLAST AND THEIR
 LISTED OUTPUT. THIS CAN BE FOUND IN 13-415.2.ABC.1.3
 (1) (2)
 BASED ON THE FIXTURE LEGEND AND WATTAGE PER FIXTURE
 SHOWN, THE TOTAL ON TABLE AS SHOWN IS LOWER THAN AMOUNT
 FIGURED BY THIS OFFICE.
 PLEASE GO OVER ALL FIXTURES AND EXPAND ON THE SQ FT
 USE. PLEASE ALSO BE SURE TO PLACE INFORMATION FOR ANY
 CHANGES IN BALLAST VA OUTPUTS.
 PLEASE SEE NOTE ON TABLE MENTIONS TOTAL FIXTURE
 *COMBUSTION* THIS SEEMS TO BE A MISPRINT FOR
 *CONSUMPTION*.
  
 3) NOTE: NEW NOTE* PLEASE SEE 13-413.1.ABC.2.1 AND .2.2
 AND PLACE NOTE SON PLANS ACCORDINGLY. THIS WAS
 CONFIRMED WITH THE FLORIDA BUILDING COMMISSION SINCE
 THE LAST REVIEW AND NOTES ARE REQUIRED ON PLANS.
  
 ** CODES REFLECTED ON SHEET E-8 PART 3 ARE NOT FROM
 CURRENT CODE. (99 NEC) THIS CAN BE REDLINED WITH OUT
 PRINTING NEW SHEET.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-11-08 Cont ID  
Sent By dpalmer Date 2007-11-08 Time 16:48 Rev Time 0.00
Received By dpalmer Date 2007-11-08 Time 09:52 Sent To  
Notes
2007-11-08 16:49:29** DENIED 2ND REVIEW **
  
  
 ** PLEASE SEE THERE ARE SOME COMMENTS FROM PREVIOUS
 REVIEW WHICH ARE IN NEED OF ADDRESSING ALONG WITH NEW
 COMMENTS AS THERE ARE ITEMS NOW ON PLANS WHICH HAVE NEW
 COMMENTS.
  
 1) NOTE: PLEASE SEE THE INFORMATION ON THE TITLE BLOCKS
 FOR ARCHITECTURAL FIRM DOES NOT CORRELATE AND
 INFORMATION COULD NOT BE CONFIRMED WITH THE STATE
 DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION.
 PLEASE SEE THE TITLE BLOCKS ON A SHEETS CONTAINS A
 DIFFERENT LICENSE NUMBER THAN THE NUMBER LISTED ON
 E-SHEETS FOR ARCHITECTURAL FIRM.
 PLEASE SEE ATTACHED PRINT OUT FROM STATE WITH NUMBER AS
 LISTED.
 PLEASE SE FAC61G1-16.004, FS 481.219
 ** REQUIRED FOR ALL SHEETS AND FOR ALL TRADES WHETHER
 OR NOT COMMENT IS MADE BY OTHER TRADES.
  
 2) NOTE: PLEASE SEE MISSING LIGHTING CONTROLS PER FBC
 CHAPTER 13. PREVIOUS REVIEW WENT OVER THE SCOPE AND
 THAT NEW LIGHTING AND DEVICES WAS UNCLEAR. AS PLANS NOW
 INDICATE THESE ITEMS AS NEW, THE NEW DEVICES SHALL
 COMPLY WITH 13-415.1.ABC.1.1, AND .1.2.
  
 3) NOTE: PLEASE SEE FBC CHAPTER 13, 13-415.2, 13-101.
 PLEASE SUBMIT LIGHTING PERFORMANCE CALCULATIONS FOR
 ROOMS IN WHICH NEW LIGHTING IS BEING INSTALLED.
  
 4) NOTE: PLEASE NFPA-101 708 AND 7.9 AND THE MINIMUM
 LIGHTING LEVELS FOR EGRESS PATHS, EXIT ACCESS
 CORRIDORS, EXIT CORRIDORS ETC ARE REQUIRED.
 PLEASE INDICATE THE LIGHTING FIXTURES, CIRCUITING PER
 700.12F COMPLETE PHOTO-METRIC PATHS.
 FAC 61G15-33.004
 FBC 106.1.2.
  
 5) NOTE: PLEASE SEE THE PLANS WILL BE ROUTED TO
 ADDRESSING AS THIS SPACE SEEMS TO BE PART OF A LARGER
 BUILDING IN WHICH THIS SPACE WOULD HAVE A UNIT/SUITE..
 IF THIS IS A SUITE OR UNIT PLEASE INDICATE THE
 SUITE/UNIT ON PLANS.
 ** PLEASE SEE COMMENTS FROM OTHER REVIEWERS FOR THIS.
  
 6) NOTE: PLEASE KNOW THAT A RESPONSE LETTER EVEN THOUGH
 NOT REQUIRED DOES HELP THE REVIEW PROCESS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-14 Cont ID  
Sent By dpalmer Date 2007-08-14 Time 08:47 Rev Time 0.00
Received By dpalmer Date 2007-08-13 Time 18:55 Sent To  
Notes
2007-08-14 08:47:36 
 *** DENIED ***
  
 *** PLEASE NOTE: AS THERE IS INFORMATION NOT YET
 SUBMITTED FOR REVIEW, THERE MAY VERY WELL BE NEW
 COMMENTS ON THE NEXT REVIEW AS THESE ITEMS CAN NOT BE
 REVIEWED AT THIS TIME.
  
 ** PLEASE SEE AN INITIAL REVIEW WAS DONE UNDER 07060876
 WHICH IS NOW INTERIOR DEMO ONLY PERMIT.
  
  
 1) NOTE: PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE THE
 CODES TO BE STATED ON PLANS. PLEASE SEE THE FOLLOWING
 ARE REQUIRED FOR ELECTRICAL AND OTHERS WILL BE REQUIRED
 FOR OTHER TRADES. PLEASE KNOW AS OF DECEMBER 8TH, 2006
 THE STATE ADOPTED THE 2006 REVISIONS TO THE 2004 FBC
 AND THE 2005 NFPA-70. PLEASE LIST THE FOLLOWING 2004
 FBC W/ 2006 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
 2002 NFPA-72
  
 ** PLEASE SEE THERE ARE SEVERAL CODES LISTED ON PLANS
 WHICH NEED TO BE UPDATED.
  
 2) NOTE: PLEASE SEE THE NOTES GIVEN ON PREVIOUS REVIEW
 MENTIONED THE STATE OF FLORIDA INFORMATION DOES NOT
 MATCH WITH THE TITLE BLOCKS ON PLANS FOR THE
 ARCHITECTURAL FIRM. PLEASE SEE THAT THE PRINT OUT FROM
 THE STATE DEPARTMENT OF BUSINESS AND PROFESSIONAL
 REGULATION HAS BEEN ATTACHED TO NOTES ONCE AGAIN.
 PLEASE SEE THE LICENSE NUMBER FOR THE FIRM WHICH IS
 ALSO KNOW AS THE CERTIFICATE OF AUTHORIZATION NUMBER
 DOES NOT MATCH.
 FAC 61G1-16.004, FS 481.219
  
 3) NOTE: PLEASE INCLUDE CIRCUITING ON PLANS AND
 CORRELATE WITH THE SUBMITTED PANEL SCHEDULES.
 PLEASE SEE THE ROOM AND AREA DESIGNATIONS ARE TO BE
 SHOWN ON PLANS FOR USE.
 PLEASE SEE THAT THE PANEL SCHEDULES ARE TO BE SPECIFIC
 TO ROOMS, AREAS AND EQUIPMENT IN WHICH THEY FEED.
 PLEASE SEE THE BELOW COMMENTARY TAKEN FROM THE NEC.
  
  
 4) NOTE: PLEASE SEE THE SCOPE OF WORK FOR LIGHTING IS
 UNCLEAR AND WHETHER OR NOT COMPLIANCE WITH THE FBC
 CHAPTER 13 HAS BEEN MET. PLEASE SEE 13-101 FOR NEW,
 REPLACED WORK. PLEASE SEE 13-415.1.ABC.1.1, .1.2,
 13-415.2
  
 5) NOTE: PLEASE SEE FBC 11-4.28.1, .2 AND .3(4) FOR
 MINIMUM LEVELS FOR FIRE ALARMS DEVICES TO BE STATED FOR
 ANY CHANGES. PLEASE SHOW ANY NEW EXISTING WHICH MEETS
 THIS SECTION WHERE WORK IS BEING AND CHANGES ARE BEING
 MADE. THIS WAS STATED ON PREVIOUS REVIEW.
  
 6) NOTE: PLEASE INDICATE ALL EMERGENCY LIGHTING AND
 PROVIDE NEW OR EXISTING LIGHTING LEVELS FOR EGRESS
 PATHS.
 PLEASE SEE FLORIDA ADMINISTRATIVE CODE 61G15-33.004,
 NFPA-101 7.8, 7.9.
 PLEASE ALSO SEE NEC 700.12F FOR CIRCUITING OF THESE
 FIXTURES. PLEASE SEE POSSIBLE COMMENTS FROM THE FIRE
 MARSHAL.
  
 7) NOTE: PLEASE VERIFY IT/SERVER ROOM AS NOTED ON PANEL
 SCHEDULE. SHOW ROOM AND COMPLIANCE WITH THE NEC 645.4,
 645.10, 645.11 ETC.
 PLEASE SEE NFPA-75 FOR REQUIRED WALL RATINGS. NO
 HISTORY OF PERMITTING AND IT ROOM OFF AN INITIAL SEARCH
 COULD BE LOCATED.
 THIS MAY A FIELD VERIFICATION ITEM BEFORE ISSUANCE OF
 PERMIT.
  
 8) NOTE: PLEASE KNOW THAT AS FOR INFORMATIONAL PURPOSE
 THE LV AS SHOWN ON PLANS WILL BE REQUIRED TO BE UNDER A
 SEPARATE PERMIT. THESE PLANS MAY BE USED FOR REFERENCE
 HOWEVER THE PERMIT APPLICATION AND FEES WILL BE
 SEPARATE.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2008-08-12 Cont ID  
Sent By mwennerg Date 2008-08-12 Time 15:49 Rev Time 0.00
Received By mwennerg Date 2008-08-12 Time 15:49 Sent To  
Notes
2008-08-12 15:49:01REVISION SHEETS A-7 AND E-5 STAMPED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2008-06-30 Cont ID  
Sent By mawillia Date 2008-06-30 Time 14:37 Rev Time 0.00
Received By mawillia Date 2008-06-30 Time 13:45 Sent To  
Notes
2008-06-30 13:47:08*****DENIED*****
  
  
 1.SHOW LOCATION OF THE 2A10:BC RATED FIRE
 EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
 2.THE SYMBOL FOR THE RED CORRIDOR PARTITION WALL IN
 AREA K, J, H, AND G IS NOT INDICATED.
  
 3.PLEASE INDICATE REVISION(S) MADE TO SHEET A-8.
  
 THE APPROPIATE PLAN SHEETS A-6.1, A-7, A-8, AND E-4,
 AND E-5 TO BE FIRE- STAMPED WHEN THE OTHER PLAN
 EXAMINERS AS WELL AS THE ABOVE COMMENTS HAVE BEEN
 ADDRESSED.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE/HOW EACH ITEM WAS ADDRESSED
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-01-24 Cont ID  
Sent By mawillia Date 2008-01-24 Time 12:00 Rev Time 0.00
Received By mawillia Date 2008-01-24 Time 10:42 Sent To  
Notes
2008-01-24 10:43:59*****APPROVED*****
  
 ALL COMMENTS FROM THE PREVIOUS FIRE REVIEWS HAVE BEEN
 ADDRESSED; PLAN SHEETS A-6.1, A-7, A-8, AND E-4 WERE
 STAMPED, INITIALED, AND DATED.
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-12-13 Cont ID  
Sent By mawillia Date 2007-12-13 Time 16:10 Rev Time 0.00
Received By mawillia Date 2007-12-13 Time 15:10 Sent To  
Notes
2007-12-13 16:08:20*****DENIED*****
  
 THE FOLLOWING COMMENTS (OF 10) FROM THE PREVIOUS REVIEW
 STILL NEED TO BE ADDRESSED:
  
 02.DOORS THAT LEAD FROM SPECIFIC OFFICES THAT ARE
 MARKED AS EXITS, SHALL NOT BE CREDITED AS EXITS.THERE
 WOULD NOT BE CLEAR UNOBSTRUCTED TRAVEL AS IT APPLIES TO
 REQUIRED MEANS OF EGRESS.
  
 04.SPECIFY THE MINIMUM INTERIOR FINISH MATERIALS FOR
 THE WALLS AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR
 CLASS C.
  
 05.PLEASE SHOW THE LOCATION OF THE FIRE ALARM CONTROL
 PANEL ON THE FIRE ALARM LAYOUT SHEET.
  
 07.SMOKE DUCT DETECTORS SHALL INITIATE A GENERAL FIRE
 ALARM IN ACCORDANCE WITH LOCAL REQUIREMENTS.ON SHEET
 E-6, AMEND FIRE ALARM SEQUENCE OF OPERATION.
  
 09.FIRE ALARM NOTES PART 3 (SHEET E-6) REFERENCES
 FIRE SPRINKLER EQUIPMENT.IF THIS BUILDING IS
 PROTECTED BY AUTOMATIC FIRE SPRINKLER SYSTEM, PLEASE
 ADVISE AND INCLUDE SPRINKLER LAYOUT.IF NOT, PLEASE
 REMOVE ALL REFERENCES ON PLANS.
  
 10.PLEASE ILLUSTRATE THE LOCATION OF THE 2A-10BC
 RATED FIRE EXTINGUISHERS THAT SHALL BE MOUNTED AT
 DISTANCES NOT TO EXCEED 75' TRAVEL DISTANCE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-09-07 Cont ID  
Sent By mwennerg Date 2007-09-07 Time 10:36 Rev Time 0.00
Received By mwennerg Date 2007-09-07 Time 10:36 Sent To  
Notes
2007-09-07 10:53:23***DENIED***
  
 1) SITE PLAN IS DIFFICULT TO READ.
  
 2) DOORS THAT LEAD FROM SPECIFIC OFFICES THAT ARE MAKED
 AS EXITS, SHALL NOT BE CREDITED AS EXITS. THERE WOULD
 NOT BE CLEAR UNOBSTRUCTED TRAVEL AS IT APPLIES TO
 REQUIRED MEANS OF EGRESS.
  
 3) FIRE RATED DOORS SHALL BE PROVIDED WITH UL LISTED
 CLOSERS. PLEASE INDICATE IN DOOR SCHEDULE.
  
 4) PLEASE PROVIDE MINIMUM INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILING.
  
 5) PLEASE SHOW THE LOCATION OF THE FIRE ALARM CONTROL
 PANEL ON THE FIRE ALARM LAYOUT SHEET.
  
 6) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR FIRE
 ALARM REMODEL.
  
 7) IN ACCORDANCE WITH LOCAL REQUIREMENTS, DUCT SMOKE
 DETECTORS IN ADDITION TO FAN SHUT DOWN, SHALL INITIATE
 A GENERAL FIRE ALARM. (FA SEQUENCE OF OPERATION)
  
 8) FIRE NOTES ON E-6 REFERENCE THE INCORRECT EDITION OF
 NFPA 101. SHOULD READ 2003 EDITION.
  
 9) FIRE ALARM NOTES PART 3 REFERENCE FIRE SPRINKLER
 EQUIPMENT. IF THIS BUILDING IS PROTECTED BY AUTOMATIC
 FIRE SPRINKLER SYSTEM, PLEASE ADVISE AND INCLUDE
 SPRINKLER LAY OUT. IF NOT, PLEASE REMOVE ALL REFERENCES
 ON PLANS.
  
 10) PLEASE ILLUSTRATE THE LOCATION OF 2A-10B,C RATED
 FIRE EXTINGUISHERS THAT SHALL BE MOUNTED AT DISTANCES
 NOT TO EXCEED 75' TRAVEL DISTANCE.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2009-07-10 Cont ID  
Sent By shill Date 2009-07-10 Time 16:26 Rev Time 0.00
Received By shill Date 2009-07-10 Time 16:26 Sent To  
Notes
2009-07-10 16:27:13TO MECHANICAL BOX
  

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2009-04-22 Cont ID  
Sent By dpalmer Date 2009-04-22 Time 14:46 Rev Time 0.00
Received By dpalmer Date 2009-04-22 Time 14:46 Sent To M
Notes
2009-04-22 14:46:15TO RR'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2009-02-12 Cont ID  
Sent By adarroug Date 2009-02-12 Time 08:25 Rev Time 0.00
Received By adarroug Date 2009-02-12 Time 08:25 Sent To M
Notes
2009-02-12 08:25:24TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-09-19 Cont ID  
Sent By adarroug Date 2008-09-19 Time 14:54 Rev Time 0.00
Received By adarroug Date 2008-09-19 Time 14:54 Sent To  
Notes
2008-09-19 14:58:10TO "COMM" BD#36

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-09-03 Cont ID  
Sent By adarroug Date 2008-09-03 Time 14:44 Rev Time 0.00
Received By adarroug Date 2008-09-03 Time 14:44 Sent To  
Notes
2008-09-03 14:48:23TO "COMM" BD#36

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-07-17 Cont ID  
Sent By adarroug Date 2008-07-17 Time 16:30 Rev Time 0.00
Received By adarroug Date 2008-07-17 Time 16:30 Sent To  
Notes
2008-07-17 16:39:24TO "COMM" BD#32

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-05-22 Cont ID  
Sent By adarroug Date 2008-05-22 Time 10:24 Rev Time 0.00
Received By adarroug Date 2008-05-22 Time 10:24 Sent To  
Notes
2008-05-29 11:21:18TO "COMM" BD#3
2008-05-22 10:24:47WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-02-15 Cont ID  
Sent By adarroug Date 2008-02-15 Time 13:50 Rev Time 0.00
Received By adarroug Date 2008-02-15 Time 13:49 Sent To E
Notes
2008-02-15 13:50:16TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-02-01 Cont ID  
Sent By adarroug Date 2008-02-01 Time 09:02 Rev Time 0.00
Received By adarroug Date 2008-02-01 Time 09:02 Sent To  
Notes
2008-02-01 09:04:41TO "COMM" BD#14

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2007-12-21 Time   Rev Time 0.00
Received By dpalmer Date 2007-12-21 Time 09:49 Sent To  
Notes
2008-01-03 09:49:45TO COMM BOARD SPACE #61

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-24 Cont ID  
Sent By adarroug Date 2007-10-24 Time 09:30 Rev Time 0.00
Received By adarroug Date 2007-10-24 Time 09:30 Sent To  
Notes
2007-11-07 13:50:22TO "COMM" BD#52
2007-10-24 09:30:56WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-09-12 Time 11:17 Rev Time 0.00
Received By adarroug Date 2007-08-01 Time 14:31 Sent To  
Notes
2007-08-01 14:31:51TO "COMM" BD#57 W/RESUB

Review Stop M MECHANICAL (A/C)
Rev No 13 Status P Date 2009-07-24 Cont ID  
Sent By rregueir Date 2009-07-24 Time 15:17 Rev Time 0.00
Received By rregueir Date 2009-07-24 Time 15:05 Sent To PC
Notes
2009-07-24 15:11:15REVISED M-1A AND M-3 DELTA 8

Review Stop M MECHANICAL (A/C)
Rev No 12 Status P Date 2009-06-01 Cont ID  
Sent By rregueir Date 2009-06-01 Time 16:05 Rev Time 0.00
Received By rregueir Date 2009-06-01 Time 16:04 Sent To PC
Notes
2009-06-01 16:04:58REVISED M-1A AND M-1B DELTA 6

Review Stop M MECHANICAL (A/C)
Rev No 11 Status F Date 2009-06-01 Cont ID  
Sent By rregueir Date 2009-06-01 Time 16:03 Rev Time 0.00
Received By rregueir Date 2009-06-01 Time 15:54 Sent To  
Notes
2009-06-01 16:03:48REVISED M-3 DENIED:
  
 NOTE #13 HAS BEEN REMOVED FROM PLANS. THIS NOTE CALLED
 FOR MOTORIZED DAMPERS ON RTU OA INTAKES TO CLOSE WHEN
 BUILDING WAS IN UNOCCUPIED MODE. WITHOUT THIS THERE IS
 NO COMPLIANCE WITH FBC-B SECTION 13-409.1.ABC.3.3 FOR
 SHUTOFF DAMPER CONTROLS. ANY REVISION TO PLANS MUST
 STILL SHOW COMPLIANCE WITH THIS SECTION. PLEASE SHOW ON
 PLANS HOW AUTOMATIC SHUTOFF DAMPER CONTROLS ARE TO BE
 PROVIDED. THE DESIGNER'S ASSERTION THAT THE DAMPERS ARE
 NOT REQUIRED IS NOT ACCEPTED AS A VALID INTERPRETATION
 OF THE INTENT OF THIS CODE SECTION. MOTORIZED DAMPERS
 SHALL BE INSTALLED AND DESIGNED TO CLOSE WHENEVER THE
 BUILDING IS IN UNOCCUPIED MODE.
  
 ALSO, SEVERAL SECTIONS OF PAGE M-3 ARE OF POOR QUALITY
 AND NOT LEGIBLE. PLEASE SUBMIT PLANS WHICH ARE CLEAR
 AND LEGIBLE IN ACCORDANCE WITH FBC-B SECTION 106.1.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 10 Status F Date 2009-02-15 Cont ID  
Sent By rregueir Date 2009-02-15 Time 16:06 Rev Time 0.00
Received By rregueir Date 2009-02-15 Time 16:03 Sent To PC
Notes
2009-02-15 16:06:34REVISED M-3 DENIED:
  
 NOTE #13 HAS BEEN REMOVED FROM PLANS. THIS NOTE CALLED
 FOR MOTORIZED DAMPERS ON RTU OA INTAKES TO CLOSE WHEN
 BUILDING WAS IN UNOCCUPIED MODE. WITHOUT THIS THERE IS
 NO COMPLIANCE WITH FBC-B SECTION 13-409.1.ABC.3.3 FOR
 SHUTOFF DAMPER CONTROLS. ANY REVISION TO PLANS MUST
 STILL SHOW COMPLIANCE WITH THIS SECTION. PLEASE SHOW ON
 PLANS HOW AUTOMATIC SHUTOFF DAMPER CONTROLS ARE TO BE
 PROVIDED.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 9 Status P Date 2009-02-15 Cont ID  
Sent By rregueir Date 2009-02-15 Time 16:02 Rev Time 0.00
Received By rregueir Date 2009-02-15 Time 16:02 Sent To PC
Notes
2009-02-15 16:03:33PAGES M-1A AND M-1B REVISION 5

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2008-10-11 Cont ID  
Sent By rregueir Date 2008-10-11 Time 14:16 Rev Time 0.00
Received By rregueir Date 2008-10-01 Time 16:07 Sent To  
Notes
2008-10-11 14:16:52REVIEW #: 4TH FOR THIS REVISION
 ACTION: PROVISO
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 REVISED PAGES M-1A, M-1B, M-2, M-3
  
 ***************PROVISO*******************
 PROVIDE DOCUMENTATION FROM RTU MANUFACTURER SHOWING
 THESE APPLIANCES ARE DESIGNED AND CONSTRUCTED TO RESIST
 ANTICIPATED WIND PRESSURES IN ACCORDANCE WITH FBCM
 301.13 AND FBCB 1609.1. SUCH DOCUMENTATION SHALL BE
 SUBMITTED FOR A PASSED PLAN REVIEW PRIOR TO FINAL
 MECHANICAL INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 7 Status F Date 2008-09-10 Cont ID  
Sent By rregueir Date 2008-09-10 Time 08:53 Rev Time 0.00
Received By rregueir Date 2008-09-09 Time 11:30 Sent To  
Notes
2008-09-10 08:53:21REVIEW #: 2ND FOR REVISION 3
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN
 RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. THE FOLLOWING ISSUES RELATED TO RATED WALLS AND DUCT
 PENETRATIONS ARE STILL OUTSTANDING:
  
 A) PAGE M-1A IS STILL MISSING AT LEAST ONE FIRE DAMPER
 AT THE 12X12 DUCT PENETRATION OF THE WALL BETWEEN ROOM
 #7 AND ROOM #138. THERE IS STILL A FIRE DAMPER SHOWN ON
 THE PLANS IN THE 6 INCH ROUND DUCT AT THE NON-RATED
 WALL BETWEEN ROOM #130 AND THE MAIN LOBBY.
 PAGE M-1B IS STILL MISSING ONE FIRE DAMPER IN THE 24X12
 DUCT PENETRATION OF THE WALL BETWEEN ROOM #7 AND ROOM
 #138.
  
 B) OK
  
 C) PAGE M-2: FIRE/SMOKE DAMPERS HAVE BEEN REMOVED FROM
 PLANS. HOWEVER, THE PLANS DO NOT SHOW PROVISIONS FOR
 FAN SHUT-DOWN BY DUCT SMOKE DETECTOR AS REQUIRED IN
 ACCORDANCE WITH FBCM 606.2. SHOW COMPLIANCE WITH THIS
 SECTION.
  
 2 AND 3: OK
  
 4. PAGE M-3: ONE OF THE TWO ROOF CURB DETAILS WHICH
 WERE PASTED ONTO THIS PAGE IS SMALL AND ILLEGIBLE.
 ALSO, BOTH OF THE CURB DETAILS ARE IN CONFLICT WITH THE
 STRUCTURAL DETAILS FOR ROOF CURB INSTALLATION. SEE PAGE
 SD-3. ALSO, THE RTU TIE-DOWN DETAIL SHOWS CABLES
 ATTACHING TO SOME SORT OF CONCRETE EMBEDDED ANCHORING
 SYSTEM INSTALLED IN A CONCRETE SLAB. HOW IS THIS
 INSTALLATION POSSIBLE ON A ROOF WHICH CONSISTS OF A
 BUILT-UP ROOF SYSTEM ON A STEEL DECK OVER BAR JOISTS?
 THIS IS THE TYPE OF ROOFING SYSTEM SHOWN ON STRUCTURAL
 PLANS. CLARIFY AND COORDINATE STRUCTURAL AND MECHANICAL
 DRAWINGS. ADDITIONALLY, STILL NO INFORMATION WAS
 PROVIDED FROM THE RTU OR EXHAUST FAN MANUFACTURERS
 SHOWING THEIR APPLIANCES ARE DESIGNED TO RESIST WIND
 PRESSURES. MECHANICAL EQUIPMENT, APPLIANCES AND
 SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND
 INSTALLED TO RESIST THE WIND PRESSURES ON THE EQUIPMENT
 AND THE SUPPORTS AS DETERMINED IN ACCORDANCE WITH FBCM
 301.13.
  
 5 AND 6: OK
  
 7. COOLING LOAD CALCULATIONS IN THE FORM OF A SYSTEM
 SIZING SUMMARY HAVE BEEN PROVIDED AS REQUESTED.
 HOWEVER, ALSO SUBMITTED WAS 3 COPIES OF ENERGY
 CALCULATIONS FOR WHAT APPEARS TO BE ANOTHER PROJECT
 LOCATED IN ANOTHER JURISDICTION. WHAT IS THE PURPOSE OF
 INCLUDING THESE CALCULATIONS WITH THIS SUBMITTAL?
 PLEASE CLARIFY.
 NOTE: A COMPLETE ENERGY CODE COMPLIANCE FORM IS NOT
 REQUIRED FOR THIS PROJECT. ONLY COMPLIANCE WITH THE
 BASIC PRESCRIPTIVE REQUIREMENTS IS NECESSARY IN
 ACCORDANCE WITH FBCB 13-101.6.
  
 NOTE: PLEASE RESPOND TO EACH COMMENT IN WRITING WITH A
 DESCRIPTION OF HOW EACH COMMENT HAS BEEN ADDRESSED AS
 WELL AS WHERE THE INFORMATION CAN BE FOUND. REMOVE
 OLD/VOIDED SHEETS FROM THE SUBMITTED PLANS AND PROVIDE
 ONE SET OF OLD VOIDED/SHEETS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2008-08-06 Cont ID  
Sent By rregueir Date 2008-08-06 Time 15:04 Rev Time 0.00
Received By rregueir Date 2008-08-05 Time 15:41 Sent To  
Notes
2008-08-06 15:04:45REVIEW #: REVISION 3
 ACTION:
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN
 RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. THE FOLLOWING ISSUES RELATED TO RATED WALLS AND DUCT
 PENETRATIONS ARE STILL OUTSTANDING:
  
 A) THE DUCT FLOOR PLAN HAS BEEN SPLIT INTO TWO PAGES,
 ONE FOR SUPPLY (M-1A) AND ONE FOR RETURN (M-1B). BOTH
 PAGES ARE MISSING FIRE DAMPERS AT SEVERAL LOCATIONS OF
 DUCT PENETRATIONS OF RATED WALLS. ALSO, SOME FIRE
 DAMPERS ARE SHOWN AT NON-RATED WALL LOCATIONS. SHOW
 COMPLIANCE WITH FBCM 607.2, 607.5 AND 607.8.
 NOTE: ONE SET OF MECHANICAL PLANS HAS BEEN MARKED-UP
 DURING THIS REVIEW TO SHOW RATED WALL LOCATIONS AND
 LOCATIONS OF MISSING DAMPERS AND DAMPERS LOCATED OUT OF
 RATED WALLS.
  
 B) PAGE M-1B SHOWS ALL DAMPERS IN THE RETURN DUCT TO BE
 COMBINATION FIRE/SMOKE DAMPERS. PAGE M-1A SHOWS ONLY
 STANDARD FIRE DAMPERS. WHICH ONE IS CORRECT? PLEASE
 CLARIFY. ALSO, IF FIRE/SMOKE DAMPERS ARE TO BE
 INSTALLED, SMOKE DAMPERS SHALL CLOSE UPON ACTUATION OF
 A LISTED SMOKE DETECTOR OR DETECTORS INSTALLED IN
 ACCORDANCE WITH SECTIONS 907.10 AND 907.11 OF THE
 FLORIDA BUILDING CODE, BUILDING AND ONE OF THE METHODS
 LISTED UNDER FBCM 607.3.2.1, AS APPLICABLE. PLEASE SHOW
 HOW THE SMOKE DAMPERS ARE TO BE ACTUATED IN ACCORDANCE
 WITH THIS SECTION..
  
 C) PAGE M-2 SHOWS SUPPLY DUCT PENETRATIONS AT ROOF
 PROVIDED WITH FIRE/SMOKE DAMPERS. THERE IS NO
 INDICATION ON ARCHITECTURAL PLANS THAT THE ROOF IS A
 FIRE RESISTANCE RATED ASSEMBLY WHICH REQUIRES PROTECTED
 PENETRATIONS. IF DAMPERS ARE REQUIRED, WHY ARE THEY
 ONLY ON THE SUPPLY AND NOT THE RETURN? WHAT TYPE OF
 ASSEMBLY IS BEING PENETRATED? IF DAMPERS ARE TO BE
 INSTALLED, PROVIDE DETAIL SHOWING HOW THESE DAMPERS ARE
 TO BE INSTALLED AT A RATED PENETRATION IN ACCORDANCE
 WITH FBCM 607.6 AND 607.8.
 NOTE: IT APPEARS THAT POSSIBLY THE FIRE/SMOKE DAMPERS
 SHOWN ON THE ROOF ARE SUPPOSED TO BE DUCT SMOKE
 DETECTORS, SINCE THEY ARE ONLY ON THE SUPPLY AND THE
 DUCT SMOKE DETECTORS ARE NOT SHOWN ANYWHERE ON THE
 PLANS. FAN SHUT-DOWN BY SMOKE DETECTOR IS REQUIRED IN
 ACCORDANCE WITH FBCM 606.2.
  
 2. OK
  
 3. OK
  
 4. NO INFORMATION WAS PROVIDED REGARDING THE OUTDOOR
 APPLIANCES, SUCH AS THE ROOFTOP PACKAGE UNITS AND
 EXHAUST FANS, AND THEIR DESIGN RELATED TO WIND
 RESISTANCE. APPLIANCES EXPOSED TO WIND SHALL NOT ONLY
 BE INSTALLED, BUT SHALL ALSO BE DESIGNED TO RESIST WIND
 PRESSURES IN ACCORDANCE WITH FBCM 301.13. PROVIDE
 SUPPORTING DOCUMENTATION FROM THE DESIGNERS OF THESE
 APPLIANCES.
  
 5. OK
  
 6. OK
  
 7. COOLING LOAD CALCULATIONS HAVE NOT BEEN PROVIDED FOR
 THE NEW APPLIANCES BEING INSTALLED. COOLING LOAD
 CALCULATIONS SHALL BE PROVIDED IN ACCORDANCE WITH FBCB
 13-407.1.ABC.1.
  
 8. OK
  
 9. OK
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2008-06-16 Cont ID  
Sent By rregueir Date 2008-06-16 Time 16:51 Rev Time 0.00
Received By rregueir Date 2008-06-16 Time 13:20 Sent To  
Notes
2008-06-16 16:51:00REVIEW #: REVISION 1
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. THE AIR DISTRIBUTION SYSTEMS (DUCTWORK) FOR THE NEW
 AC SYSTEMS ARE SHOWN PENETRATING MANY RATED WALL
 ASSEMBLIES IN MANY LOCATIONS THROUGHOUT THE WORK AREA
 WITHOUT PROTECTION OF THE PENETRATIONS. FIRE DAMPERS
 SHALL BE PROVIDED AT THE LOCATIONS PRESCRIBED IN
 ACCORDANCE WITH FBCM 607.5. THE SPECIFIC LOCATION AND
 INSTALLATION DETAILS OF EACH FIRE DAMPER SHALL BE SHOWN
 AND PROPERLY IDENTIFIED ON THE BUILDING PLANS BY THE
 DESIGNER IN ACCORDANCE WITH FBCM 607.8.
 NOTE: PLEASE SEE MARKED-UP PAGE M-1 FOR EXAMPLES OF
 LOCATIONS.
  
 2. PAGE M-1 FLOOR PLAN PROPOSES THE USE OF RETURN AIR
 PLENUM CEILINGS WITH CENTRALIZED RETURN AIR INTAKES. IN
 MANY LOCATIONS RETURN AIR GRILLS ARE SHOWN IN THE
 CEILING TO ALLOW AIR TO TRAVEL BACK TO THE AC UNIT.
 HOWEVER, IN MANY LOCATIONS THE AIR WILL NOT BE ABLE TO
 TRAVEL BACK TO THE UNIT BECAUSE THE SPACE IS ISOLATED
 FROM THE UNIT BY FIRE RATED PARTITIONS WHICH GO FROM
 FLOOR TO UNDERSIDE OF THE ROOF. IT IS NOT POSSIBLE TO
 HAVE BALANCED RETURN UNDER THESE CIRCUMSTANCES.
 PROVISIONS SHALL BE MADE IN BOTH RESIDENTIAL AND
 COMMERCIAL BUILDINGS TO AVOID UNBALANCED AIR FLOWS AND
 PRESSURE DIFFERENTIALS CAUSED BY RESTRICTED RETURN AIR
 IN ACCORDANCE WITH FBCM 601.4.
  
 3. A NEW PLENUM SPACE ABOVE THE CEILING IS BEING
 CREATED WHERE ONE DID NOT PREVIOUSLY EXIST. THE
 EXISTING CONDITIONS FOR EXTERIOR WALLS AND ROOF DECK
 ARE NOT KNOWN AND THE INFORMATION HAS NOT BEEN PROVIDED
 AS PART OF THIS REVISION. PLEASE ADDRESS THE FOLLOWING
 ISSUES:
 A) MATERIALS EXPOSED WITHIN PLENUMS SHALL BE
 NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF
 NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT
 MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84.
 FBCM 606.2.2.1.
 B) CAVITIES DESIGNED FOR AIR TRANSPORT SUCH AS
 MECHANICAL CLOSETS, CHASES, AIR SHAFTS, ETC. SHALL BE
 LINED WITH AN AIR BARRIER AND SEALED IN ACCORDANCE WITH
 SECTION 603.9 AND SHALL BE INSULATED IN ACCORDANCE WITH
 TABLE 13-410.1.ABC.2.2 OR TABLE 13-610.1.ABC.2.1 OF
 CHAPTER 13 OF THE FLORIDA BUILDING CODE, BUILDING. THIS
 INCLUDES EXTERIOR WALLS WHICH ARE EXPOSED TO THE
 PLENUM. SEE FBCM 603.9.1 FOR APPROVED AIR BARRIERS.
 C) BUILDING CAVITIES BENEATH A ROOF DECK THAT WILL BE
 USED AS RETURN AIR PLENUMS SHALL HAVE AN INSULATED ROOF
 WITH THE INSULATION HAVING AN R-VALUE OF AT LEAST R-19.
 FBCM 603.8.
  
 4. MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT
 ARE EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO
 RESIST THE WIND PRESSURES AS DETERMINED IN ACCORDANCE
 WITH THE FLORIDA BUILDING CODE, BUILDING PER FBCM
 301.13. PROVIDE THE FOLLOWING:
 A) DETAIL FOR ATTACHMENT OF ROOF CURBS TO BUILDING
 STRUCTURE AND ROOFTOP APPLIANCES TO ROOF CURBS WITH
 SUPPORTING WIND LOAD CALCULATIONS. THIS INCLUDES
 ROOFTOP AC UNITS AND EXHAUST FANS.
 B) SUBMITTAL DATA FROM ROOFTOP AC UNIT AND EXHAUST FAN
 MANUFACTURER SHOWING THESE APPLIANCES ARE DESIGNED AND
 MANUFACTURED TO RESIST ANTICIPATED WIND PRESSURES.
  
 5. SHOW MEANS AND LOCATION OF CONDENSATE DISPOSAL.
 CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL
 BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED
 PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO
 A STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A
 NUISANCE IN ACCORDANCE WITH FBCM 307.2.1.
  
 6. AUXILIARY DRAIN PROTECTION IS REQUIRED ON ROOFTOP AC
 UNITS IN ACCORDANCE WITH FBCM 307.2.3. THIS MAY BE
 ACCOMPLISHED BY INSTALLING A WATER LEVEL DETECTION
 DEVICE INSIDE THE UNIT IN THE PRIMARY DRAIN PAN.
  
 7. PROVIDE COOLING LOAD CALCULATIONS FOR NEW AC SYSTEMS
 IN ACCORDANCE WITH FBCB 13-407.1.ABC.1.
  
 8. FRESH AIR SCHEDULES ON REVISED M-3 STILL SHOWS AHU-1
 AND AHU-2 WHEN THESE UNITS HAVE BEEN REPLACED. PROVIDE
 OUTSIDE AIR SCHEDULE WHICH CORRESPONDS WITH THE NEW
 ROOFTOP UNIT SCHEDULE IN ACCORDANCE WITH FBCM TABLE
 403.3.
  
 9. SHUTOFF DAMPER CONTROLS ARE REQUIRED. SHOW
 COMPLIANCE WITH FBCB 13-409.1.ABC.3.3. NOTE #13 CALLS
 FOR MOTORIZED DAMPERS TO CLOSE WHEN UNITS TURN OFF.
 THIS CODE SECTION REQUIRES THE VOLUME DAMPERS TO BE
 CLOSED WHENEVER BUILDING IS IN UNOCCUPIED MODE,
 REGARDLESS OF WHETHER OR NOT THE UNITS ARE RUNNING.
 THIS MAY BE ACCOMPLISHED IN CONJUNCTION WITH OFF-HOUR
 CONTROLS AS REQUIRED BY FBCB 13-407.1.ABC.2.4. SHOW
 COMPLIANCE WITH THESE SECTIONS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-02-11 Cont ID  
Sent By rregueir Date 2008-02-11 Time 15:54 Rev Time 0.00
Received By rregueir Date 2008-02-11 Time 15:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2008-01-19 Cont ID  
Sent By rregueir Date 2008-01-19 Time 13:52 Rev Time 0.00
Received By rregueir Date 2008-01-19 Time 13:33 Sent To  
Notes
2008-01-19 13:52:40REVIEW #: 3RD
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 ALL PREVIOUS REVIEW COMMENTS HAVE BEEN ADDRESSED WITH
 THE EXCEPTION OF THE FOLLOWING:
  
 M-1: NOTE FOR MOTORIZED DAMPERS, THE OUTSIDE AIR
 DAMPERS ARE TO BE CLOSED WHENEVER BUILDING IS IN
 UNOCCUPIED MODE, REGARDLESS OF WHETHER AHU'S ARE
 RUNNING. CORRECT NOTE TO SHOW DAMPERS CLOSED DURING
 UNOCCUPIED MODE. FBC 13-409.1.ABC.3.3
  
 M-2: FRESH AIR SCHEDULE FOR AHU-4 SHOWS 1,000 CFM OF
 OUTSIDE AIR REQUIRED, BUT THE DESIGN CFM ONLY CALLS FOR
 30 CFM. PLEASE CORRECT AND RESUBMIT. FBC, M 403.3.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-11-24 Cont ID  
Sent By rregueir Date 2007-11-24 Time 09:12 Rev Time 0.00
Received By rregueir Date 2007-11-21 Time 09:17 Sent To  
Notes
2007-11-24 09:12:07REVIEW #: 2ND
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN
 RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. THIS COMMENT WAS NOT ADDRESSED. PROVIDE A LEGEND ON
 PLANS SHOWING THE MEANINGS OF ABBREVIATIONS AND SYMBOLS
 ON PLANS. FBC 106.1.1.
  
 2. LETTER FROM ENGINEER REGARDING EXISTING EQUIPMENT IS
 NOTED. ENERGY CALCULATIONS ARE NOT REQUIRED.
 NOTE: ALL NEW COMPONENTS, SUCH AS DUCTWORK, ARE SUBJECT
 TO THE MINIMUM PRESCRIPTIVE REQUIREMENTS OF FBC CHAPTER
 13 IN ACCORDANCE WITH FBC, EB 611.1 AND FBC
 13-400.0.C.4. SHOW ALL NEWLY INSTALLED COMPONENTS IN
 SUFFICIENT DETAIL TO DEMONSTRATE COMPLIANCE WITH FBC
 CH. 13.
  
 3. THIS COMMENT WAS NOT ADDRESSED. SEE PREVIOUS COMMENT
 FOR RELEVANT CODE SECTIONS AND REQUIREMENTS.
  
 4. OK. REVIEW COMMENTS RELATED TO FLOOR PLANS WILL BE
 AT THE END OF COMMENTS 1 THROUGH 10.
  
 5. OK. REVIEW COMMENTS RELATED TO FLOOR PLANS WILL BE
 AT THE END OF COMMENTS 1 THROUGH 10.
  
 6. BASED ON THE ATTACHED LETTER FROM THE ENGINEER,
 THERE IS NO NEW A/C EQUIPMENT BEING INSTALLED.
 THEREFORE, DETAILS FOR NEWLY INSTALLED EQUIPMENT ON M-2
 ARE NOT APPLICABLE AND SHOULD BE REMOVED, UNLESS
 EXISTING EQUIPMENT IS BEING RETROFITTED TO MATCH THE
 INSTALLATION METHODS SHOWN IN THE DETAILS. FBC, EB
 609.2.
  
 7. SAME AS COMMENT #6 ABOVE.
  
 8. SAME AS COMMENT #6 ABOVE.
  
 9. THIS COMMENT WAS NOT ADDRESSED.
  
 10. THIS IS A MINIMUM PRESCRIPTIVE REQUIREMENT OF FBC
 CHAPTER 13 AND SHALL BE IN COMPLIANCE PER FBC, EB
 611.1. ALSO, PROVIDE SHUTOFF DAMPER CONTROLS IN
 ACCORDANCE WITH FBC 13-409.1.ABC.3.3 AND FBC, EB
 611.1.
  
 NEW COMMENTS: THE FOLLOWING NEW COMMENTS ARE THE RESULT
 OF INFORMATION WHICH WAS MISSING FROM PLANS DURING
 FIRST REVIEW.
  
 A. M-1: BASED ON THE LOCATIONS OF RATED WALL ASSEMBLIES
 AS SHOWN ON A-6, THERE ARE SEVERAL LOCATIONS WHERE
 DUCTS ARE SHOWN PENETRATING RATED WALLS. SHOW OPENING
 PROTECTIVES AT THESE DUCT PENETRATIONS AS REQUIRED BY
 FBC, M 607.5. ONE SET OF PLANS HAS BEEN MARKED TO SHOW
 MANY (BUT POSSIBLY NOT ALL) LOCATIONS.
  
 B. PLEASE PROVIDE A WRITTEN NARRATIVE OR RESPONSE TO
 PLAN REVIEW COMMENTS AS THIS WILL SPEED THE REVIEW
 PROCESS AND ASSIST IN OBTAINING A PERMIT.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-08-14 Cont ID  
Sent By rregueir Date 2007-08-14 Time 19:53 Rev Time 0.00
Received By rregueir Date 2007-08-14 Time 18:03 Sent To  
Notes
2007-08-14 19:53:15------------------DENIED-------------------
  
 FBC 2004 CODE FAMILY WITH 2005 AND 2006 REVISIONS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. PROVIDE A LEGEND SHOWING THE MEANINGS OF
 ABBREVIATIONS AND SYMBOLS ON MECHANICAL FLOOR PLANS.
 FBC 106.1.1.
  
 2. PROVIDE EQUIPMENT SCHEDULE SHOWING MODEL, SIZE,
 RATINGS, EFFICIENCY AND ELECTRICAL REQUIREMENTS. FBC
 106.3.5.1.4. ALTERATIONS SUBJECT TO THIS CHAPTER SHALL
 COMPLY WITH THE REQUIREMENTS OF CHAPTER 13 OF THE
 FLORIDA BUILDING CODE, BUILDING. FBC, EB 611.1
  
 3. PROVIDE OUTDOOR AIR CALCULATIONS BASED ON FBC,M
 TABLE 403.3. INCLUDE OCCUPANCY CLASSIFICATION, OCCUPANT
 LOAD, OUTDOOR AIR RATE, OUTDOOR AIR REQUIRED AND
 OUTDOOR AIR PROVIDED. ALL RECONFIGURED SPACES INTENDED
 FOR OCCUPANCY AND ALL SPACES CONVERTED TO HABITABLE OR
 OCCUPIABLE SPACE IN ANY WORK AREA SHALL BE PROVIDED
 WITH NATURAL OR MECHANICAL VENTILATION OR EXHAUST IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, MECHANICAL.
 FBC, EB 609.2
  
 4. PG A6 AND A7, PRINTING O PLANS IS OF POOR QUALITY
 MAKING IT DIFICULT TO DIFFERENTIATE BETWEEN WALL TYPES.
 ALSO, THERE IS NO WALL LEGEND ON PG A7, YET THERE ARE
 WALL TYPES WHICH DIFFER FROM THE LEGEND ON A6. PLEASE
 CLARIFY AS THE LOCATION OF RATED WALLS WILL IMPACT
 MECHANICAL PLAN REVIEW.
  
 5. SEVERAL AREAS ON PG A6 ARE MARKED AS "NOT PART OF
 THIS PERMIT" BUT THOSE AREAS ARE SHOWN ON M-1 AS PART
 OF THE SCOPE OF WORK. THE ACTUAL SCOPE OF WORK RELATED
 TO MECHANICAL CAN NOT BE DETERMINED AND IS UNCLEAR
 BASED ON THE INFORMATION PROVIDED IN THESE PLANS. FLOOR
 PLAN CAN NOT BE REVIEWED AT THIS TIME.
  
 6. M-2: DETAIL FOR NEW EQUIPMENT ON ROOF, PLEASE
 PROVIDE A ROOF PLAN SHOWING THE LAYOUT OF EQUIPMENT,
 LOCATION OF EXHAUST AND INTAKE OPENINGS. ALSO, CU STAND
 NOA AND INSTALLATION INSTRUCTIONS WERE NOT INCLUDED IN
 THIS SUBMITTAL. PLEASE PROVIDE THEM ALONG WITH ALL
 REQUIRED SUPPORTING DOCUMENTATION.
  
 7. M-2: STRTAPS ON CU'S FOR WIND LOADS SHALL NOT
 INTERFERE WITH SERVICE ACCESS OF EQUIPMENT PER FBC,M
 306.1.
  
 8. NOTES ON EQUIPMENT REFERENCE DIFFERENT REGIONS AND
 DIFFERENT WIND LOAD REQUIREMENTS. THIS PROJECT IS
 LOCATED IN THE CITY OF WEST PALM BEACH AND AS SUCH, IS
 IN THE 140 MPH WIND ZONE. SHOW ALL OUTDOOR ATTACHMENTS
 TO BE DESIGNED FOR THESE WIND LOADS PER FBC,M 301.13
 AND FBC CH.16.
  
 9. SHOW MEANS AND LOCATION OF ALL CONDENSATE DISPOSAL
 PER FBC,M 307.2.1 THROUGH 307.2.5.
  
 10. PROVIDE AN AIR BALANCE SCHEDULE FOR THE BUILDING
 SHOWING OVERALL BUILDING PRESSURIZATION. MECHANICAL
 SYSTEMS SHALL BE DESIGNED TO ASSURE THAT BUILDINGS ARE
 PRESSURIZED WITH RESPECT TO OUTDOORS. FBC
 13-409.1.ABC.2. ALTERATIONS SUBJECT TO THIS CHAPTER
 SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 13 OF THE
 FLORIDA BUILDING CODE, BUILDING. FBC, EB 611.1
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2008-07-29 Cont ID  
Sent By mperson Date 2008-07-29 Time 14:51 Rev Time 0.00
Received By mperson Date 2008-07-29 Time 14:51 Sent To  
Notes
2008-07-29 14:53:57REVISION ADDED NEW SHEET P-2: "OK" CONDENSATE DRAIN AND
 DRY WELL LAYOUT AND DETAILS.

Review Stop P PLUMBING
Rev No 4 Status F Date 2008-06-10 Cont ID  
Sent By mperson Date 2008-06-10 Time 10:40 Rev Time 0.00
Received By mperson Date 2008-06-10 Time 10:40 Sent To  
Notes
2008-06-10 11:33:23PLUMBING PLAN REVIEW:
 DENIED REVISION:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 1. SHEET P-2 ROOF PLAN CD LAYOUT: CLEARLY INDICATE THE
 PIPING MATERIAL BEING USED FOR THE NEW CONDENSATE. PER
 FBC- PLUMBING SECTION 308.3 MATERIAL.
  
 2. SHEET P-2 ROOF PLAN CD LAYOUT: PROVIDE A DETAIL OF
 HOW THE NEW CONDENSATE PIPING WILL BE ANCHORED TO MEET
 140 MPH WIND LOADS. PER FBC-PLUMBING SECTION 308.7
 ANCHORAGE AND FBC- BUILDING CHAPTER 16 SECTION 1609.1.3
 ANCHORAGE AGAINST OVER TURNING, UPLIFT AND SLIDING. .
  
 3. SHEET P-2 CONDENSATE DRAIN DRYWELL DETAIL #4:
 PLEASE CLARIFY HOW THE DRY WELL WITHOUT A COVER
 INSTALLED AND WITH THE TOP OF THE DRY WELL AT GROUND
 LEVEL WILL BE PROTECTED FROM BEING SATURATED DURING
 HEAVY RAIN STORMS, PROTECTED FROM HAVING DIRT OR MULCH
 BEING WASHED INTO IT THEREBY ALLOWING WEEDS TO GROW IN
 IT AND ALSO PROTECTED FROM LAWN MAINTENANCE MATERIALS.
 PER FBC- PLUMBING SECTION 301.1 SCOPE.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-01-04 Cont ID  
Sent By mperson Date 2008-01-04 Time 10:40 Rev Time 0.00
Received By mperson Date 2008-01-04 Time 10:40 Sent To  
Notes
2008-01-04 11:12:24****************PROVISO****************
 607.3 THERMAL EXPANSION CONTROL. (TANKLESS WATER
 HEATER)
 A MEANS OF CONTROLLING INCREASED PRESSURE CAUSED BY
 THERMAL EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN
 ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2 .
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-12-06 Cont ID  
Sent By mperson Date 2007-12-06 Time 06:03 Rev Time 0.00
Received By mperson Date 2007-12-06 Time 06:03 Sent To  
Notes
2007-12-06 07:22:06PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS
 TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED 2ND TIME:
  
 *****PREVIOUS REVIEW COMMENTS*****
  
 1. PLEASE CORRECT THE TITLE BLOCK INDICATING THE WRONG
 ARCHITECTURAL FIRM LICENSE NUMBER FOR GAMBACH
 ARCHITECTS INC. PER FAC 61G1-16.004 AND FS 481.219 ON
 THE RESUBMITTAL.
 **NOTE: COMMENT NOT ADDRESSED. PLEASE SEE ATTACHED DBPR
 PRINT OUT WITH CORRECT FIRM LICENSE NUMBER TO THESE
 PLUMBING COMMENTS. PLEASE SEE ALL SHEETS NEED TO COMPLY
 ON RESUBMITTAL.
  
 2. OK, COMMENT ADDRESSED.
  
 *****THE FOLLOWING ARE NEW COMMENTS*****
  
 3. SHEET A-6 AND P-1 REST AREA ARE INDICATING AN ADDED
 SINK THAT IS NOT CLEARLY IDENTIFIED. PLEASE CLEARLY
 IDENTIFY THIS SINK ON THE RESUBMITTAL AND ADD THE
 REQUIRED SANITARY AND WATER TO THE RISER DIAGRAMS,
 DETAILED PLUMBING LAYOUT, AND PLUMBING FIXTURE SCHEDULE
 ON SHEET P-1. PER 106.3.5.1.3, PLUMBING.
  
 4. NOTE: THE ADDED SINK IN REST AREA SHALL BE
 ACCESSIBLE PER CHAPTER 11, THE FOLLOWING SECTIONS.
  
 **11-4.24 SINKS (ELEVATION DETAIL REQUIRED WITH THE
 FOLLOWING INFORMATION)
 11-4.24.2 HEIGHT. MAXIMUM 34" A.F.F. TO RIM OR
 COUNTER.
 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, 30" WIDE,
 AND 19" DEEP.(NO CABINET DOORS OR BASE)
 11-4.24.4 DEPTH. MAXIMUM 6-1/2" DEEP.
 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND CLEAR FLOOR
 SPACE SHALL EXTEND A MAXIMUM OF 19" UNDERNEATH THE
 SINK.(NO CABINET DOORS OR BASE)
 11-4.24.6 EXPOSED PIPES AND SURFACES. INSULATE TO
 PROTECT AGAINST CONTACT.
 11-4.24.7 FAUCETS. LEVER-OPERATED, PUSH-TYPE, OR
 ELECTRONICALLY CONTROLLED ARE ACCEPTABLE DESIGNS.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-09-07 Cont ID  
Sent By mperson Date 2007-09-07 Time 13:39 Rev Time 0.00
Received By mperson Date 2007-09-07 Time 13:39 Sent To  
Notes
2007-09-07 14:22:02DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
 ** FBC-2004 CHAPTER 11, FLORIDA ACCESIBILITY CODE.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PLEASE CORRECT THE TITLE BLOCK INDICATING THE WRONG
 ARCHITECTURAL FIRM LICENSE NUMBER FOR GAMBACH
 ARCHITECTS INC. PER FAC 61G1-16.004 AND FS 481.219 ON
 THE RESUBMITTAL.
  
 2. PLEASE INDICATE THE FOLLOWING ACCESSIBLE
 REQUIREMENTS PER FBC-2004 CHAPTER 11 THE FOLLOWING
 SECTIONS:
  
 ** 11-4.15 DRINKING FOUNTAINS AND WATER COOLERS (PLEASE
 PROVIDE AN ELEVATION DETAIL WITH INFORMATION FROM THE
 FOLLOWING SECTIONS)
  
 A} 11-4.15.2 SPOUT HEIGHT.
  
 B} 11-4.15.3 SPOUT LOCATION.
  
 C} 11-4.15.4 CONTROLS.
  
 D} 11-4.15.5 (2) CLEARANCES
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2007-11-08 Cont ID  
Sent By eschneid Date 2007-11-08 Time 18:47 Rev Time 0.00
Received By eschneid Date 2007-11-08 Time 18:47 Sent To  
Notes
2007-11-08 18:49:31PERMIT VALUE 10% OF BUILDING VALUE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved