Plan Review Details - Permit 07071001
| Plan Review Stops For Permit 07071001 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-18 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-18 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2008-11-18 10:06:15 | REVISION | | | | | | KNEE WALL AND SOFFIT DETAIL | | | LIGHT POLE BASE DETAIL; **PROVISO** SUBMIT SHOP | | | DRAWINGS PRIOR TO INSTALLATION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-18 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-18 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2008-11-18 09:59:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. ADDITIONAL FEES DUE; 7 SHEETS SUBMITTED FOR THIS | | | REVISION. | | | | | | 2. THE ACCESSIBLE PARKING SPACE IS TO BE LOCATED ON THE | | | SHORTEST SAFELY ACCESSIBLE ROUTE OF TRAVEL. THE PARKING | | | SPACE SELECTED IS NOT THE SHORTEST ROUTE. PLEASE | | | EXPLAIN RATIONALE FOR THIS LOCATION. FBC11-4.6.2. | | | | | | 3. THE NEW ACCESSIBLE PARKING SPACE IS LOCATED ON A | | | ROUTE WHICH HAS A PORTION WHICH IS 36" WIDE. SEE | | | FBC11-4.6.2(1), ACCESSIBLE PARKING SPACES ARE TO BE ON | | | AN ACCESSIBLE ROUTE WHICH IS TO BE NO LESS THAN 44 | | | INCHES. | | | | | | 4. THE TWO WINDOWS ON THE 2ND FLOOR HAVE BEEN REPLACED | | | BY A SKYLIGHT. ENERGY CALCS ARE TO BE REVISED. | | | | | | 5. PROVIDE THE VALUE FOR THE ADDITIONAL WORK (5 LIGHT | | | POLES AND BASES, SOFFIT, KNE WALLS, ETC.). | | | | | | 6. PRODUCT APPROVALS REQUIRED FOR THE SKYLIGHT, | | | FAC9B72. PRODUCT APPROVALS TO BE REVIEWED BY DESIGNER | | | OF RECORD PRIOR TO SUBMITTAL. FBC*106. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-07 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-07 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2008-11-07 15:18:13 | REVISION, SHEETS S1, S2, S3, S4; LETTERS RE ACCESSIBLE | | | PARKING (RESOLVED IN FIELD) AND UNITY EQUATION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-09-09 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-09-09 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2008-09-09 09:04:15 | BUILDING REVISION PASSED W/PROVISO; ENGINEER TO ADDRESS | | | COMMENTS FROM BUILDING REVIEW #8 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-09-09 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-29 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2008-09-09 09:03:29 | ****CORRECTIONS**** | | | BUILDING REVISION | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. PLEASE INCORPORATE ALL CHANGES INTO THE PLAN. FOR | | | INSTANCE, SHEET 1 OF 3 CHANGES SHOULD BE INCORPORATED | | | INTO THE LOWER ROOF FRAMING DETAIL, S1. | | | | | | 2. THERE APPEAR TO BE SHEETS MISSING FROM THE REVISION. | | | IT INCLUDES 1, 2, AND 3 OF 3, AND 1 OF 4. WHERE ARE 2 | | | THROUGH 4 OF 4? | | | | | | 3. SEE SHEET S2 AND THE SIMPSON 2008 GENERAL CATALOG, | | | PAGE 14, ITEM E. THE LINK IS INCLUDED BELOW AND IS | | | PRINTED AND ATTACHED FOR YOUR CONVENIENCE. PLEASE | | | CLARIFY THE COMBINED STRESS INDEX OF 92% STATED ON THE | | | PLAN. IF ALL THREE LOADS ARE TAKEN INTO ACCOUNT AS PER | | | THE CATALOG (AND THE CATALOG IN EFFECT AT TIME OF | | | DESIGN), THE FORMULA EXCEEDS 1; IT RESULTS IN 1.53. IF | | | UPLIFT AND PARALLEL AND UPLIFT AND PERPENDICULAR ARE | | | TAKEN INTO ACCOUNT SEPARATELY, IT RESULTS IN 1.22 AND | | | .97 RESPECTIVELY. IT IS NOT CLEAR HOW THE ENGINEER HAS | | | ARRIVED AT A COMBINED STRESS INDEX OF 92%. PLEASE | | | CLARIFY OR REVISE AS NECESSARY. | | | | | | HTTP://WWW.STRONGTIE.COM/FTP/CATALOGS/C-2008/C-2008-P01 | | | 4.PDF | | | | | | 4. SEE S2, PARALLEL TO TRUSS (F1) AND PERPENDICULAR TO | | | TRUSS (F2), PLEASE NOTE THAT F1 IN THE SIMPSON CATALOG | | | REFERS TO FORCES PARALLEL TO THE WALL, NOT PARALLEL TO | | | TRUSS. F2 REFERS TO FORCES PERPENDICULAR TO THE WALL. | | | PLEASE CLARIFY AND REVISE IF NECESSARY. | | | | | | 5. PLEASE PROVIDE A VALUE FOR THE NEW WORK (FRAMING FOR | | | SKYLIGHT, SKYLIGHT). | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-21 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-21 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2008-08-21 10:31:41 | REVISION, ROOFING NOAS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-11 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-11 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2008-08-11 15:26:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | | RECORD, FBC*106. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-20 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-20 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-19 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-08 |
Time |
17:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-02-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-02-14 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-14 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2008-02-14 12:27:26 | ****CORRECTIONS**** | | | | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | COMMENTS FROM PREVIOUS LIST | | | | | | 1.INDICATE LEVEL OF ALTERATION, FBC EB301.5. | | | | | | LEVEL 2 DECLARED.PLEASE CLARIFY; WORK AREA IS OVER | | | 50% OF THE BUILDING, THEREFORE APPEARS TO BE A LEVEL 3. | | | SEE FBC EB CHAPTER 3. | | | | | | 2-6.)ADDRESSED. | | | | | | 7.I WAS UNABLE TO LOCATE THE SPIRAL STAIR SHOPS. | | | PLEASE HAVE THE ARCHITECT INCORPORATE DESIGN INTO THE | | | PLAN, FBC1009.9. | | | | | | 3RD REVIEW; SHOPS DO NOT SHOW CODE COMPLIANCE WITH ALL | | | REQUIREMENTS OF FBC1009.9.PLEASE INCORPORATE ALL | | | REQUIRED DESIGN CRITERIA INTO THE PLAN. | | | | | | NOTE THE FOLLOWING: | | | | | | A.FBC1009.9.1, RISER HEIGHT IS NOT TO EXCEED 7". | | | FBC1009.9.2 DOES NOT APPLY BECAUSE THIS IS NOT A | | | MEZZANINE, FLOOR AREA EXCEEDS 250', AND OCCUPANT LOAD | | | SHOULD BE 4.9 1/2" RISER HEIGHT HAS BEEN SPECIFIED, | | | PLEASE REVISE. | | | | | | B.SHOW COMPLIANCE WITH FBC1009.9.1 (2) AND (3) | | | REGARDING TREAD DEPTH.A 12" DIMENSION WAS SHOWN BUT | | | PURPOSE OF THIS DIMENSION IS NOT CLEAR. | | | | | | C.FBC1009.9.1 (4), INSIDE HANDRAIL NOT SHOWN. PROVIDE | | | A HANDRAIL DETAIL IN COMPLIANCE WITH FBC1009.1(4) AND | | | (5).NO HANDRAIL EXTENSIONS ARE SHOWN. | | | | | | D.A LINE WHICH APPEARS TO GRAPHICALLY SHOW THE | | | HANDRAIL TO THE OUTSIDE OF THE STAIR GOES ACROSS THE | | | STAIR TREAD.WHAT IS THIS? | | | | | | E.VERTICAL ACCESSIBILITY CAN BE EXEMPTED | | | FBC11-4.1.6(1)(K)(III), A SPACE NOT OPEN TO THE PUBLIC | | | AND AN OCCUPANT LOAD OF LESS THAN 5.PLEASE MAKE NOTE | | | ON THE PLAN THAT THIS AREA IS NOT OPEN TO THE PUBLIC. | | | HOWEVER, EXEMPTION FROM VERTICAL ACCESSIBILITY | | | REQUIREMENTS DOES NOT WAIVE OTHER REQUIREMENTS FOR | | | ACCESSIBILITY.SEE FBC11-4.1.6(1)(A) AND (B).SEE | | | HANDRAIL HEIGHT AND EXTENSION REQUIREMENTS OF | | | FBC1009.11, FBC11-4.8.5.PROVIDE GUADRAIL AND HANDRAIL | | | DETAILS. | | | | | | 8.ROOF FRAMING ENGINEERING WAS SUBMITTED.THE | | | STRUCTURAL ENGINEER HAS SPECIFIED DESIGN CRITERIA OF | | | EXPOSURE C (S2) AND A BCLL OF 10PSF (SEE WOOD TRUSS | | | NOTES).THE TRUSS ENGINEER HAS STATED THAT A | | | NONCURRENT LIVE LOAD OF 10PSF HAS BEEN CHECKED, BUT THE | | | ENGINEERING IS FOR 0 BCLL.PLEASE CORRELATE STRUCTURAL | | | DESIGN WITH THE TRUSS ENGINEERING, REVISE AS NECESSARY, | | | AND HAVE THE TRUSS ENGINEERING REVIEWED BY DESIGNER OF | | | RECORD. | | | | | | 9-13. ADDRESSED. | | | | | | 14.ARCHITECT STATES IN HIS RESPONSE LETTER (AND ON | | | A1) THAT OCCUPANT LOAD IS LESS THAN 3 FOR THE SECOND | | | FLOOR.SEE FBC1004.1, OCCUPANT LOAD CANNOT BE LESS | | | THAN FBC TABLE 1004.SEE OTHER COMMENTS REGARDING | | | OCCUPANT LOAD. | | | | | | 3RD REVIEW, SEE 2ND FLOOR.WHEN SCALED, THE INTERIOR | | | DIMENSIONS ARE 23' (24'6"-16") BY 14.33'(15'8"-16"); | | | 332 SF, OCCUPANT LOAD OF 4.ALL NUMBERS SHOULD BE | | | ROUNDED UP TO THE NEAREST WHOLE NUMBER AS THE OCCUPANT | | | LOAD CANNOT BE LESS THAN TABLE 1004 AND YOU CANNOT HAVE | | | A PORTION OF A PERSON.REVISE OCCUPANT LOAD | | | ACCORDINGLY. | | | | | | 15-22. ADDRESSED. | | | | | | 23.PLEASE REVISE OCCUPANCY AND OCCUPANT LOAD FOR | | | SECOND FLOOR AS DISCUSSED WITH ARCHITECT. | | | | | | 3RD REVIEW, SEE ITEM 14. | | | | | | 24-25.)ADDRESSED. | | | | | | 26.A1, OCCUPANT LOAD CANNOT BE LESS THAN FBC TABLE | | | 1004 AS PER FBC1004.1.THE TOTAL SQUARE FOOT AREA USED | | | TO CALCULATE OCCUPANT LOAD IS NOT CONSISTENT WITH THE | | | SQUARE FOOT AREA OF THE SPACE.PLEASE REVISE. | | | | | | SEE OTHER COMMENTS REGARDING OCCUPANT LOAD. | | | | | | 27.ADDRESSED. | | | | | | 28.INCLUDE 2007 AMENDMENTS IN GOVERNING CODE | | | EFFECTIVE JULY 1, 2007. | | | | | | PLEASE REVISE STRUCTURAL SHEETS.THIS PROJECT IS | | | AFFECTED BY 2007 REVISIONS. | | | | | | 29.ADDRESSED. | | | | | | NEW COMMENTS: | | | | | | 30.PLEASE PROVIDE FLORIDA STATE PRODUCT APPROVAL FOR | | | ALL PRODUCTS, IF AVAILABLE.WWW.FLORIDABUILDING.ORG. | | | THIS IS REQUIRED IN ADDITION TO THE MIAMIDADE NOAS | | | PROVIDED, FAC9B72. | | | | | | 31.THE SMITH MOUNTAIN WINDOW IS SMALL MISSILE IMPACT | | | RATED; LARGE MISSILE REQUIRED, FBC1609.1.4. | | | | | | 32.WHERE WILL THE WOOD INFILL FRAMING DETAIL BE | | | INSTALLED, S3? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-04 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-03 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2007-12-04 15:31:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | COMMENTS FROM PREVIOUS LIST | | | | | | 1.INDICATE LEVEL OF ALTERATION, FBC EB301.5. | | | | | | PLEASE SEE FBC CHAPTER 3.THE ARCHITECT HAS DECLARED | | | LEVEL 2 AND HAS PROVIDED INFORMATION REGARDING | | | VALUATION.SEE FBC EB 202, DEFINITIONS, REPAIR.THIS | | | IS NOT A REPAIR FOR BUILDING CODE PURPOSES.SEE FBC EB | | | 305, WORK AREA APPEARS TO BE OVER 50% OF THE BUILDING. | | | THE INFORMATION PROVIDED REGARDING VALUATION DOES NOT | | | AFFECT THE LEVEL OF ALTERATION DETERMINATION.PLEASE | | | CLARIFY CORRECT LEVEL OF ALTERATION AS CODE COMPLIANCE | | | AND REQUIREMENTS CANNOT BE DETERMINED BASED ON THE | | | INFORMATION PROVIDED. | | | | | | 2.ADDRESSED. | | | | | | 3.THE ARCHITECT STATES THAT THIS IS MERCANTILE CLASS | | | B IN HIS LETTER AND AT TOP LEFT OF SHEET A1, AND | | | DECLARES THIS AS MERCANTILE GROUP M ON A1, BUILDING | | | DATA.PLEASE SEE FBC302.1, PORTIONS OF BUILDINGS TO BE | | | CLASSIFIED ACCORDING TO FBC 302.3.IT APPEARS THAT | | | THIS SPACE IS MIXED USE AS THE OFFICE AREA DOES NOT | | | COMPLY WITH THE DEFINITION OF ACCESSORY USE, FBC302.2. | | | | | | ARCHITECT IS DECLARING THIS AS MERCANTILE B, BUT B IS | | | BUSINESS, MERCANTILE IS M.PLEASE CLASSIFY EACH | | | PORTION OF THE BUILDING.WHAT WAS THE PREVIOUS | | | OCCUPANCY OF THIS SPACE? | | | | | | CONTRACTOR HAS INDICATED THAT THIS IS A CHANGE OF | | | OCCUPANCY.IF THIS IS NOT THE CASE, REVISE THE | | | APPLICATION.IF THIS IS A CHANGE OF OCCUPANCY, INCLUDE | | | IN THE BUILDING DATA INFORMATION ON A1. | | | | | | 4-6. ADDRESSED. | | | | | | 7.I WAS UNABLE TO LOCATE THE SPIRAL STAIR SHOPS. | | | PLEASE HAVE THE ARCHITECT INCORPORATE DESIGN INTO THE | | | PLAN, FBC1009.9. | | | | | | 8.SHOPS FOR ROOF FRAMING WERE NOT SUBMITTED AS | | | STATED.THIS CAN BE REVIEWED PRIOR TO INSTALLATION. | | | | | | 9-13. ADDRESSED. | | | | | | 14.ARCHITECT STATES IN HIS RESPONSE LETTER (AND ON | | | A1) THAT OCCUPANT LOAD IS LESS THAN 3 FOR THE SECOND | | | FLOOR.SEE FBC1004.1, OCCUPANT LOAD CANNOT BE LESS | | | THAN FBC TABLE 1004.SEE OTHER COMMENTS REGARDING | | | OCCUPANT LOAD. | | | | | | 15-22. ADDRESSED. | | | | | | NEW COMMENTS: | | | | | | 23.PLEASE REVISE OCCUPANCY AND OCCUPANT LOAD FOR | | | SECOND FLOOR AS DISCUSSED WITH ARCHITECT. | | | | | | 24.PLAN A1 SHOWS A SITE WALL TO BE DEMOLISHED, BUT IT | | | APPEARS THAT THE STAIR RAIL IS ON THIS WALL.FBC EB | | | 501.2. | | | | | | 25.2MP1, CONCRETE PADS ARE SHOWN ON THE ROOF.THIS | | | CONFLICTS WITH THE DETAIL ON S3.PLEASE CORRELATE AND, | | | IF USING CONCRETE PADS, STRUCTURAL ENGINEER IS TO | | | ADDRESS THE ADDITIONAL DEAD LOAD ON THE ROOF. | | | | | | 26.A1, OCCUPANT LOAD CANNOT BE LESS THAN FBC TABLE | | | 1004 AS PER FBC1004.1.THE TOTAL SQUARE FOOT AREA USED | | | TO CALCULATE OCCUPANT LOAD IS NOT CONSISTENT WITH THE | | | SQUARE FOOT AREA OF THE SPACE.PLEASE REVISE. | | | | | | 27.PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER | | | OF RECORD, FBC*106.3.3. | | | | | | 28.INCLUDE 2007 AMENDMENTS IN GOVERNING CODE | | | EFFECTIVE JULY 1, 2007. | | | | | | 29.SHOW ACCESSIBLE ROUTE AND ACCESSIBLE PARKING, | | | FBC1104.1.2, 11-4.1.2(1). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-09-06 |
Time |
20:54 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-08-28 |
Time |
17:00 |
Sent To |
I |
|
| Notes |
| 2007-08-28 18:01:51 | PROJECT: 740 BELVEDERE ROAD/STAR BAKERY CAFE | | | | | | PROJECT DETAIL: INTERIOR / EXTERIOR ALTERATION &NEW | | | COVERED ENTRY | | | | | | PLAN REVIEW: | | | | | | 2004 FLORIDA EXISTING BUILDING CODE/ 2006 REVS.2004 | | | FLORIDA BUILDING CODE W/2006 REVS. | | | CITY OF WPB ADMINISTRATIVE AMENDMENTS/2004 | | | | | | COMMENTS: | | | | | | 1) PLEASE INDICATE THE LEVEL OF ALTERATION OR | | | COMBINATIONS IF APPLICABLE: | | | | | | 301.5 . A DESIGN PROFESSIONAL OR AN OWNER MUST | | | ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO SECTION 303,304 & | | | 305 OF THIS CODE. | | | | | | 2) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE | | | FOLLOWING: | | | | | | FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) THE PERMIT APPLICATION REFLECTS A CHANGE OF | | | OCCUPANCY. PLEASE INDICATE THE EXISTING OCCUPANCY AS | | | PER THE FOLLOWING: | | | | | | 812.1.2CHANGE OF OCCUPANCY GROUP WITH SEPARATION. A | | | PORTION OF AN EXISTING BUILDING THAT IS CHANGED TO A | | | NEW OCCUPANCY GROUP AND THAT IS SEPARATED FROM THE | | | REMAINDER OF THE BUILDING WITH A FIRE RATED | | | WALL/CEILING HAVING A FIRE-RESISTANCE RATING AS | | | REQUIRED IN THE FLORIDA BUILDING CODE, BUILDING FOR THE | | | SEPARATE OCCUPANCY SHALL COMPLY WITH ALL THE | | | REQUIREMENTS OF CHAPTER 7 FOR THE NEW OCCUPANCY GROUP | | | AND WITH THE REQUIREMENTS OF THIS CHAPTER. EXCEPTION: | | | COMPLIANCE WITH ALL OF THE PROVISIONS OF CHAPTER 7 IS | | | NOT REQUIRED WHEN THE CHANGE OF USE COMPLIES WITH THE | | | REQUIREMENTS OF SECTION 812.3. | | | | | | 4) PROVIDE AN ASBESTOS SURVEY IF APPLICABLE AS PER THE | | | FOLLOWING: | | | | | | 105.9 ASBESTOS. | | | THE ENFORCING AGENCY SHALL REQUIRE EACH BUILDING PERMIT | | | FOR THE DEMOLITION OR RENOVATION OF AN EXISTING | | | STRUCTURE TO CONTAIN AN ASBESTOS NOTIFICATION STATEMENT | | | WHICH INDICATES THE OWNER?S OR OPERATOR?S | | | RESPONSIBILITY TO COMPLY WITH THE PROVISIONS OF SECTION | | | 469.003, FLORIDA STATUTES, AND TO NOTIFY THE DEPARTMENT | | | OF ENVIRONMENTAL PROTECTION OF HIS OR HER INTENTIONS TO | | | REMOVE ASBESTOS, WHEN APPLICABLE, IN ACCORDANCE WITH | | | STATE AND FEDERAL LAW. | | | | | | 5) PLEASE INDICATE THE FIRE- RATING OF THE EXISTING | | | OCCUPANCY WALL SEPARATION. | | | | | | 6)SHEET A-1 REFLECTS THAT THE EXISTING 2ND FLOOR WILL | | | BE USED FOR STORAGE WHICH IS INCIDENTAL TO THE | | | MERCHANTILE OCCUPANCY AREA. PLEASE INDICATE THE TYPES | | | OF MATERIALS TO BE STORED ON THE 2ND FLOOR. THE FORMER | | | SHALL COMPLY WITH THE FOLLOWING: | | | | | | 302.1.1 INCIDENTAL USE AREAS. | | | SPACES WHICH ARE INCIDENTAL TO THE MAIN OCCUPANCY SHALL | | | BE SEPARATED OR PROTECTED, OR BOTH, IN ACCORDANCE WITH | | | TABLE 302.1.1 OR THE BUILDING SHALL BE CLASSIFIED AS A | | | MIXED OCCUPANCY AND COMPLY WITH SECTION 302.3. AREAS | | | THAT ARE INCIDENTAL TO THE MAIN OCCUPANCY SHALL BE | | | CLASSIFIED IN ACCORDANCE WITH THE MAIN OCCUPANCY OF THE | | | PORTION OF THE BUILDING IN WHICH THE INCIDENTAL USE | | | AREA IS LOCATED. | | | | | | 7) SUBMIT MANUFACTURER'S SPECIFICATIONS/SHOP DRAWINGS | | | FOR THE NEW METAL SPIRAL STAIRS AS SHOWN ON SHEET A-2. | | | STAIRS MUST COMPLY WITH FBC 1009.9. | | | | | | 8) THE INDICATED SERVICE COUNTER-TOPS SHALL MEET THE | | | REQUIREMENTS OF THE ACCESSIBILITY CODE: | | | | | | 11-5.2 COUNTERS AND BARS. | | | WHERE FOOD OR DRINK IS SERVED AT COUNTERS EXCEEDING 34 | | | INCHES (865 MM) IN HEIGHT FOR CONSUMPTION BY CUSTOMERS | | | SEATED ON STOOLS OR STANDING AT THE COUNTER, A PORTION | | | OF THE MAIN COUNTER WHICH IS 60 INCHES (1525 MM) IN | | | LENGTH MINIMUM SHALL BE PROVIDED IN COMPLIANCE WITH | | | SECTION 11-4.32 OR SERVICE SHALL BE AVAILABLE AT | | | ACCESSIBLE TABLES WITHIN THE SAME AREA. | | | | | | 9) PLEASE SUBMIT TOWER ROOF FRAMING LAYOUT AND TRUSS | | | ENGINEERING FOR REVIEW. | | | | | | 10) SUBMIT THE STOREFRONT WINDOW FRAMING | | | ENGINEERING/PRODUCT APPROVALS | | | | | | 11) SUBMIT PRODUCT APPROVALS FOR WOOD MEMBER | | | ANCHORS/HANGERS/STRAPS. | | | | | | 12) PLEASE PROVIDE A DETAIL FOR THE MECHANICAL | | | CONNECTION OF THE 2X WOOD LEDGER. SEE SHEET S-1. | | | | | | 13) PLEASE PROVIDE EPOXY SPECIFICATIONS FOR REINFORCING | | | STEEL EMBEDMENT AS SHOWN ON SHEET S-1, NOTE 1. | | | | | | 14) PLEASE INDICATE THE MEANS OF EGRESS ILLUMINATION AT | | | THE OFFICE/STORAGE EXTERIOR STAIRS. THE SAME SHALL | | | COMPLY WITH THE FOLLOWING: | | | | | | 1006.1 MEANS OF EGRESS ILLUMINATION. | | | | | | 1006.1.1 | | | ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THIS SECTION FOR EVERY BUILDING AND | | | STRUCTURE. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT | | | ACCESS SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS AND PASSAGEWAYS LEADING TO | | | AN EXIT. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT | | | DISCHARGE SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS, WALKWAYS AND EXIT | | | PASSAGEWAYS LEADING TO A PUBLIC WAY. | | | EXCEPTIONS: | | | 1. WHEN APPROVED BY THE BUILDING OFFICIAL, ILLUMINATION | | | OF MEANS OF EGRESS SHALL NOT BE REQUIRED IN INDUSTRIAL | | | AND STORAGE OCCUPANCIES THAT ARE OCCUPIED ONLY DURING | | | DAYLIGHT HOURS, WITH SKYLIGHTS OR WINDOWS ARRANGED TO | | | PROVIDE THE REQUIRED LEVEL OF ILLUMINATION ON ALL | | | PORTIONS OF THE MEANS OF EGRESS DURING THESE HOURS. | | | 2. ASSEMBLY OCCUPANCY PRIVATE PARTY TENTS OF 1,200 | | | SQUARE FEET (111 M2) OR LESS SHALL NOT BE REQUIRED TO | | | PROVIDE ILLUMINATION OF MEANS OF EGRESS. | | | 3. OPEN STRUCTURES SHALL NOT BE REQUIRED TO PROVIDE | | | ILLUMINATION OF MEANS OF EGRESS. | | | 4. TOWERS OCCUPIED BY NOT MORE THAN THREE PERSONS SHALL | | | NOT BE REQUIRED TO PROVIDE ILLUMINATION OF MEANS OF | | | EGRESS. | | | | | | 15) PLEASE DIMENSION THE EXISTINGEXTERIOR STAIR WIDTH | | | AT THE OFFICE/STORAGE EXIT. | | | | | | 16) PLEASE DIMENSION THE SPANS OF THE 2X12 WOOD | | | MEMBERS: | | | | | | 1603.1 GENERAL. | | | CONSTRUCTION DOCUMENTS SHALL SHOW THE SIZE, SECTION AND | | | RELATIVE LOCATIONS OF STRUCTURAL MEMBERS WITH FLOOR | | | LEVELS, COLUMN CENTERS AND OFFSETS FULLY DIMENSIONED. | | | THE DESIGN LOADS AND OTHER INFORMATION PERTINENT TO THE | | | STRUCTURAL DESIGN REQUIRED BY SECTIONS 1603.1.1 THROUGH | | | 1603.1.8 SHALL BE CLEARLY INDICATED ON THE CONSTRUCTION | | | DOCUMENTS FOR PARTS OF THE BUILDING OR STRUCTURE. | | | | | | 17) PLEASE PROVIDE CLARIFICATION FOR THE FOLLOWING: | | | | | | A) DETAIL 2-S4 DEPICTS FRAMING ONLY. WHAT IS | | | REQUIRED FOR THE WALL SHEATHING AND WALL COVERING? B) | | | SHOW ATTACHMENT/FASTENING PATTERN OF THE DESIGN WALL | | | SHEATHING. | | | C) ON DETAIL 2-S4, THE BOTTOM METAL TRACK IS | | | ATTACHED TO THE ROOF JOISTS WITH TEK SCREWS. WHAT IS | | | THE MINIMUM EMBEDMENT/LENGTH OF | | | SCREW TO BE USED? | | | | | | 18) PROVIDE ROOF FLASHING DETAIL AT TOWER TO LOW ROOF | | | TRANSITION. | | | | | | 19) PLEASE REVISE BUCK INSTALLATION CHART TO NOTE THAT | | | BUCKS SHALL BE FULL WIDTH OF THE WINDOW/DOOR FRAMES: | | | | | | 1714.5.4.2 MASONRY, CONCRETE OR OTHER | | | STRUCTURAL SUBSTRATE. | | | | | | WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 1? | | | INCHES (38 MM), WINDOW AND DOOR ASSEMBLIES SHALL BE | | | ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR | | | SUBFRAME SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER?S | | | PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE | | | SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE | | | OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS | | | OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE | | | ROUGH OPENING SUBSTRATE. | | | WHERE THE WOOD BUCK THICKNESS IS 1? INCHES (38 MM) OR | | | GREATER, THE BUCK SHALL BE SECURELY FASTENED TO | | | TRANSFER LOAD TO THE MASONRY, CONCRETE OR OTHER | | | STRUCTURAL SUBTRATE AND THE BUCK SHALL EXTEND BEYOND | | | THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME.WINDOW | | | AND DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN | | | FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM OR THROUGH THE | | | FLANGE TO THE SECURED WOOD BUCK IN ACCORDANCE WITH THE | | | MANUFACTURER?S PUBLISHED INSTALLATION INSTRUCTIONS. | | | UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME ASSEMBLY | | | TO THE SECURED WOOD BUCK. | | | | | | 20) PLEASE PROVIDE DETAIL FOR IN-FILL FRAMING AT THE | | | INDICATED DOOR DELETION. SEE DETAIL 2-A2. | | | | | | 21) REVISE DOOR SCHEDULE: WHERE IS DOOR TYPE 5-11 | | | LOCATED ON THE PLAN? | | | | | | 22) PRIOR TO RE-SUBMITTING THE REVIEWED PLANS, PLEASE | | | MAKE CERTAIN TO REVIEW AND ADDRESS EACH OF THE | | | AFOREMENTIONEDCOMMENTS AND MAKE ALL CORRECTIONS WHERE | | | APPLICABLE. FAILURE TO DO SOWILL IMPEDE THE | | | EXPEDITING OF THE PERMIT ISSUANCE. | | | | | | PLAN REVIEW: KEN CONRAD | | | PHONE: 561.805.6666 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-03 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-03 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-04 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-04 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2008-05-04 15:34:45 | ** DENIED 4TH REVIEW ** | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING. | | | | | | 1) NOTE:PLEASE SEE THE LIFE SAFETY CODE NFPA-101 | | | 7.8.1.3 AND 7.9.2. | | | PLEASE SEE THE PREVIOUS REVIEWS REQUESTED THE LIGHTING | | | LEVELS FOR NORMAL AND EMERGENCY LEVELS FOR STAIRS WHICH | | | WERE USED FOR REQUIRED EGRESS PATHS. THE LEVELS ARE NOW | | | SHOWN FOR THE NEW REVISED INTERIOR EGRESS STAIRS | | | HOWEVER THE LIGHTING LEVELS UNDER NORMAL ARE NOT | | | SHOWN. | | | PLEASE SEE THE EXTERIOR STAIRS ARE NOT SHOWING A | | | FIXTURE WHICH IS BATTERY BACK UP. THE PLANS MENTIONS | | | THE LIGHTS ARE FLOODS HOWEVER THESE WHICH ARE | | | IDENTIFIED AS *ES* FIXTURES ARE NOT ON THE FIXTURE | | | LEGEND. | | | PLEASE SEE 700.12F FOR REQUIRED BATTERY BACK UP. | | | PLEASE SEE THE NEXT COMMENT AS THE LIGHTING CONTROLS ON | | | PLANS CLEARLY SHOW A SINGLE POLE SWITCH HOWEVER THE | | | PANEL SCHEDULE MENTIONS TO PLACE THESE LIGHTS ON | | | PHOTO-SENSOR. HOW IS THIS POSSIBLE WHEN THESE ARE | | | BATTERY BACK UP UNLESS THE SPECIFIC FIXTURE IS SHOWN | | | WITH THIRD LEG TO *PERMANENT HOT*. | | | PARKING LOT LIGHTS, | | | LANDSCAPE LIGHTS, | | | SCONCE LIGHTS, | | | FLOOD LIGHTS, ETC ETC. | | | | | | 2) NOTE: PLEASE SEE 13-415.2, 13-415.2.ABC.1., .1.2 AND | | | .1.3. | | | HOW CAN THE CALCULATIONS BE VERIFIED FOR COMPLIANCE | | | WHEN NOT ALL LIGHT FIXTURES ARE SHOWN ON THE FIXTURES | | | LEGEND? THIS IS NOTED ABOVE FOR FLOOD FIXTURES *ES* AND | | | FIXTURES NOTED AS *SW*. | | | PLEASE COMPLETE LIGHTING PERFORMANCE CALCULATIONS. | | | | | | *** IMPORTANT, PLEASE BE SURE THE WATTAGE FIGURED INTO | | | THE CALCULATIONS IS BASED ON THE MAXIMUM FIXTURE | | | WATTAGE, NOT THE WATTAGE OF THE LIGHT BULB. THE CODE | | | REQUIRES THE FIXTURE VA RATING. | | | | | | ** THE ABOVE FIXTURES AS NOTED ARE NOT AN EXHAUSTED | | | LIST OF POSSIBLE FIXTURES WHICH ARE NOT INCLUDED IN | | | CALCULATIONS PER CODE. THESE ARE NOTED AS A BENEFIT. | | | | | | 3) NOTE: PLEASE SEE 13-415.1.ABC.1.4 WHICH REQUIRES TWO | | | PERMITTED METHOD OF CONTROLS FOR OUTSIDE LIGHTING | | | INCLUDING SIGNS. | | | PANEL SCHEDULES MAKE SOME NOTES TO TIME CLOCKS AND | | | PHOTO-SENSORS HOWEVER PLANS DO NOT GIVE DETAILS FOR | | | CODE COMPLIANCE. PLANS SHOW NO DETAIL FOR TC OR PS. | | | PLANS STILL ALSO SHOW STANDARD SINGLE POLE SWITCHES FOR | | | MANY OF THE OUTSIDE LIGHTS. | | | PLEASE KNOW THE ONLY TIME CLOCK PERMITTED IS AN | | | ASTRONOMICAL TIME CLOCK AND REQUIRES A MINIMUM OF 10HRS | | | BATTERY BACK UP FOR PROGRAMMING. | | | PLEASE SEE ANOTHER EXAMPLE IS REAR DOOR FIXTURE TO | | | CIRCUIT *A-36* WHICH CLEARLY DOES NOT EVEN INDICATE ANY | | | NOTE FOR OTHER CONTROLS EXCEPT A SINGLE POLE SWITCH. | | | PLEASE KNOW THE MINIMUM REQUIRED BY CODE IS THE INTENT | | | TO TURN OFF LIGHTING DURING DAYLIGHTS HOURS IN THE EVEN | | | OF HUMAN FAILURE TO TURN LIGHTING OFF. THE REASON FOR | | | AN ASTRONOMICAL TIME CLOCK IS THAT IT WILL KEEP UP WITH | | | DAYLIGHT SAVINGS TIMES AND WILL NOT CONTINUALLY NEED TO | | | BE RE-SET ETC. IN THE EVENT OF POWER FAILURE THE | | | REQUIRED BACK UP WILL RETAIN PROGRAMMING SO LIGHTS WILL | | | NOT COME ON DURING THE DAY. THIS IS THE REASON FOR | | | LIGHTING CONTROLS. | | | MAY NOT USE A STANDARD SINGLE POLE SWITCH AS THE OVER | | | RIDE WITHOUT HAVING AUTOMATED SHUT OFF AT DAYLIGHT. | | | | | | | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-01 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-01 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2008-02-01 14:42:01 | ** DENIED 3RD REVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEWS ARE | | | STILL IN NEED OF CORRECTIONS. PLEASE ALSO SEE THERE ARE | | | NEW COMMENT(S) BASED ON INFORMATION NOW PLACED ON PLANS | | | WHICH WAS NOT SHOWN PREVIOUSLY. | | | | | | 1) NOTE: PLEASE SEE PREVIOUS NOTE #1 WHICH SPECIFICALLY | | | REQUESTED THE FOLLOWING CODES TO BE PLACED ON | | | ELECTRICAL PLANS> | | | THIS IS REQUIRED. | | | 2004 FBC W/2007 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | | | | ** MAY NOT QUOTE *LATEST EDITION* | | | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEWS WHICH REQUESTED | | | NORMAL AND EMERGENCY PHOTO-METRIC LEVELS FOR STAIRS. | | | THE LEVELS SUBMITTED AND SHOWN ON ARCHITECTURAL PLANS | | | DO NOT MEET THE MINIMUM LEVELS AS SET-FORTH IN THE LIFE | | | SAFETY CODE. PLEASE ALSO SEE ONLY ONE LEVEL WAS | | | SUBMITTED. | | | THIS WAS IN BOTH PREVIOUS REVIEWS. | | | PLEASE SEE 7.8.1.3, 7.9.2.2 | | | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEWS REQUESTED TO | | | COMPLETE WIRING FOR ALL OUTSIDE AND LANDSCAPE LIGHTING. | | | NO SITE ELECTRICAL PLANS COULD BE LOCATED. | | | PLEASE ALSO SEE SOME OUTSIDE LIGHTING IS NOW SHOWN ON A | | | SINGLE POLE LIGHT SWITCH WHICH IS NOT PERMITTED. PLEASE | | | SEE FBC CHAPTER 13, 13-415.1.ABC.1.4, 13-415.1.ABC.2 | | | WHICH SPECIFICALLY REQUIRES AUTOMATED CONTROLS FOR | | | OUTSIDE LIGHTING LEVELS. | | | FOR EXAMPLE: OUTSIDE LIGHTS MAY NOT BE TURNED ON BE A | | | SINGLE POLE SWITCH WHICH WILL LEAVE LIGHTS ON DURING | | | DAYLIGHT HOURS AND CONDITIONS. THIS COMMENT IS FOR ALL | | | LIGHTS OUTSIDE INCLUSIVE OF LANDSCAPE, PARKING, WALL | | | LIGHTS, SIGN ETC. | | | ** PLEASE SEE THERE IS STILL NOT ENOUGH | | | PLEASE SEE PREVIOUS NOTES WITH RESPECT TO LIGHTING | | | PERFORMANCE CALCULATIONS WHICH ARE NOT COMPLETE. THE | | | FIRST REVIEW SUBMITTED METHOD *A* WHICH COULD NOT BE | | | USED BASED ON THIS WAS NOT NEW CONSTRUCTION AND DID | | | MEET THE DEFINITIONS OF RENOVATIONS. WHEN THIS IS THE | | | CASE METHOD *B* OR *C* IS REQUIRED. PLEASE SEE THE | | | PERMIT APPLICATION PACKAGE OF PLANS AND SUPPORTING | | | DOCUMENTS SUBMITTED DID NOT CONTAIN ANY FLA-COM FORMS. | | | THE LIGHTING LEVELS SHOWN ON SHEET E-1 DOES NOT CONTAIN | | | THE INFORMATION FOR PERFORMANCE LEVELS AS NEEDED AND | | | REQUIRED FOR MINIMUM COMPLIANCE WITH FBC 13-415.2, | | | 13-415.1.B, 13-415.1.C, 13-400.0.C, 13-400.0.B, | | | 13-400.3.B, 13-400.3.C, ETC | | | PLEASE SEE NO EXTERIOR ALLOWANCES WERE SHOWN, PLEASE | | | SEE 13-415.2.ABC.1.3 | | | | | | ***ATTENTION, PLEASE SEE FAC 61G15-33.004 WHICH | | | REQUIRES THE ENGINEER OF RECORD TO DESIGN MINIMUM | | | COMPLIANCE FOR ALL LIGHTING REQUIRED IN THE NEC< LS 101 | | | AND FBC. | | | | | | 4) NOTE: PLEASE SEE PREVIOUS REVIEW WHICH STATED THAT | | | NEW *EQUIPMENT GROUNDING CONDUCTORS* WERE ADDED BEFORE | | | THE FIRST MEANS OF DISCONNECT(S) WHICH IS NOT PERMITTED | | | BY THE NEC. PLEASE SEE CODE SECTIONS 250.6, 250.24. | | | PLEASE KNOW THE *EQUIPMENT GROUNDING CONDUCTORS* ARE | | | ONLY INSTALLED *AFTER* THE FIRST MEANS OF DISCONNECT. | | | AS SHOWN THIS WOULD CREATE OBJECTIONABLE CURRENTS AND A | | | UNSAFE INSTALLATION. PLEASE REMOVE. | | | | | | 5) NOTE: PLEASE SEE THE COMPLETE GROUNDING ELECTRODE | | | SYSTEM HAS NOW BEEN MOVED AND IS NOT IN COMPLIANCE WITH | | | ANY SECTION OF NEC 250. | | | PLEASE MOVE THIS GROUNDING ELECTRODE SYSTEM TO MEET | | | NEC. | | | PLEASE SEE REDLINED PLANS.THIS GEC AND SYSTEM SHALL | | | BEAS FOLLOWS:: | | | 1/0, 250.66, | | | 2-GROUND RODS, 250.50, 250.56 | | | COLD WATER PIPE, 250.50 | | | GAS *** BOND ONLY***, 250.104 | | | ** BUILDING STRUCTURAL FOOTER STEEL IS ONLY REQUIRED | | | WHERE 20FT OR MORE IS AVAILABLE. PLEASE KNOW AS THIS IS | | | AN EXISTING BUILDING AND IT DOES NOT APPEAR NEW FOOTERS | | | OF 20FT OR MORE ARE NOT BEING INSTALLED, AN ATTACHMENT | | | TO THE EXISTING IS NOT REQUIRED PER 250.50. IF THIS IS | | | SHOWN ON THE GROUNDING ELECTRODE RISER THEN IT WILL BE | | | REQUIRED. | | | EXPOSING OLD/EXISTING FOOTER WOULD BE DETRIMENTAL TO | | | THE STRUCTURAL INTEGRITY OF THE EXISTING FOOTERS. | | | | | | ** IMPORTANT** PLEASE CALL TO GO OVER THIS AS THERE IS | | | SOME LOSS IN UNDERSTANDING FROM THE COMMENTS TO WHAT IS | | | BEING DONE ON PLANS. THIS IS FOR COMMENT #4 AND 5. | | | | | | 6) NOTE: PLEASE SEE A NEW NOTE WAS ADDED TO E-2 HOWEVER | | | WAS NOT PER THE PREVIOUS NOTES OF 13-413.1.ABC.2.1 AND | | | .2.2. | | | | | | 7) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE SEE THAT A FEE OF $3, 408 IS DUE BEFORE | | | RE-SUBMITTAL OF PLANS. THIS IS NOT ASSESSED TO THE | | | CONTRACTOR OR OWNER. | | | ONE SET OF PLANS WILL BE RETAINED BY THIS OFFICE. | | | | | | 8) NOTE: PLEASE SEE FS 713.13(2), THE NOTICE OF | | | COMMENCEMENT SUBMITTED IS EXPIRED. | | | WHEN WORK HAS NOT COMMENCED WITHIN 90DAYS OF RECORDING | | | NOC, THE NOC BECOMES VOID AND WILL BE REQUIRED TO BE | | | RE-RECORDED. | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-26 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-26 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2007-11-26 09:33:43 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW STILL | | | NEED TO BE ADDRESSED ALONG WITH SOME NEW COMMENTS DUE | | | TO CHANGES ON PLANS. | | | NOTE FROM PREVIOUS REVIEW MENTIONED THERE MAY BE NEW | | | COMMENTS AS THERE WAS INFORMATION NOT SUBMITTED FOR | | | REVIEW. | | | | | | 1) NOTE: PLEASE SEE NOTE #1 FROM PREVIOUS REVIEW WHICH | | | REQUESTED THE CODES ON ELECTRICAL PLANS. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | ** IT WAS NOTED THAT THESE WERE ADDED TO A-1, HOWEVER | | | NEEDS TO BE ON ELECTRICAL PLANS ALSO. | | | | | | | | | 2) NOTE: PLEASE SEE PREVIOUS NOTE #2 AS THE LIGHTING | | | PERFORMANCE CALCULATIONS FOR INTERIOR AND EXTERIOR ARE | | | NOT COMPLETE. | | | PLEASE SEE NO INFORMATION WAS SHOWN FOR EXTERIOR AND | | | THE INFORMATION FOR INTERIOR CAN NOT BE VERIFIED AS THE | | | FIXTURE LEGEND IS NOT COMPLETE WITH FIXTURE | | | INFORMATION. | | | PREVIOUSLY SUBMITTED METHOD *A* AND NOW SUBMITTING | | | *C*. | | | PLEASE SEE 13-415.1.A, 13-415.2, 13-415.2.ABC.1.2, | | | 13-415.2.ABC.1.3, 13-415.2.ABC.1.1 | | | | | | 3) NOTE: PLEASE PROVIDE NOTES ON PLANS PER | | | 13-413.1.ABC.2.1, .2.2 | | | | | | 4) NOTE: PLEASE SEE THE PLANS STILL SHOW A *J-BOX* FOR | | | FUTURE GENERATOR YET NO INFORMATION WAS LOCATED ON | | | RISER OR PLANS. HOW WILL TRANSFER TAKE PLACE:? HOW WILL | | | THIS CONNECTION BE MADE? | | | PLEASE PROVIDE MORE INFORMATION. | | | 702.6, 110.3, 90.7 | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE CLARIFY WHERE AND HOW LOADS WERE | | | FIGURED FOR SHOW WINDOWS. PLEASE BE SURE TO ADJUST LOAD | | | CALCULATIONS PER 220.43 | | | | | | 6) NOTE: PLEASE SEE RISER NOW SHOWS *EQUIPMENT | | | GROUNDING CONDUCTORS* FROM METER TO THE FIRST MEANS OF | | | DISCONNECT. | | | PLEASE SEE 250.6, 250.24 AS THIS IS NOT PERMITTED. | | | EQUIPMENT GROUNDING CONDUCTORS ARE ONLY INSTALLED AFTER | | | THE FIRST MEANS OF DISCONNECTS. | | | | | | 7) NOTE: PLEASE SUBMIT PHOTO-METRICS FOR STAIR AREAS | | | UNDER NORMAL AND UNDER EMERGENCY. RESPONSE FROM | | | ARCHITECT MENTIONS TO SEE FBC 1006.1.1 EXCEPT #4, | | | HOWEVER PLEASE SEE THE LATEST CODE AS THIS SECTION | | | COULD NOT BE FOUND. PLEASE KNOW IN EITHER CASE AS THE | | | LIFE SAFETY CODE AND FLORIDA ADMINISTRATIVE CODE IS | | | MORE RESTRICTIVE, PLEASE SUBMIT AS PREVIOUSLY | | | REQUESTED. THESE ARE REQUIRED. FAC 61G15-33.004 | | | PLEASE SEE THAT THIS NEEDS TO INCLUDE THE EXTERIOR | | | STAIR TO THE PUBLIC RIGHT OF WAY. PLEASE PROVIDE | | | LIGHTING FIXTURES AND ALSO BATTERY BACK UP AS REQUIRED | | | UNDER THE MINIMUM REQUIREMENTS OF THE LIFE SAFETY | | | CODE. | | | PLEASE SEE NFPA-101 7.8.1.3, 7.9.2.2 | | | | | | 8) NOTE: PLEASE SEE AS ELECTRICAL FOR SECOND FLOOR IS | | | NOW BEING SUBMITTED AND SHOWN, PLEASE CLARIFY WHAT IS | | | NEW AND WHAT IS EXISTS? PLANS CONTAIN A NOTE WHICH | | | MENTIONS *ALL* IS EXISTING, YET THIS IS NOT POSSIBLE | | | WHEN THERE ARE NEW STAIRS AND NEW RECEPTACLES BEING | | | INSTALLED.THE ORIGINAL STAIR LOCATION IS NOT THE SAME | | | AND THE FLOOR LOCATION IS BEING CLOSED. PLEASE INDICATE | | | NEW AND EXISTING. | | | 10) NOTE: PLEASE SEE HAND DRAWN CHANGES ON PLANS ARE | | | NOT PERMITTED. PLEASE BE SURE TO MAKE CHANGES ON | | | REVISED PLANS. | | | FBC 106.3. | | | | | | 11) NOTE: PLEASE SUBMIT ELECTRICAL FOR SITE | | | LIGHTING/LANDSCAPE AS PREVIOUSLY NOTED. RESPONSE | | | MENTIONS CIRCUIT PROVIDE, HOWEVER AS NOTED ABOVE FOR | | | FBC CHAPTER 13 AND ELECTRICAL FOR FIXTURES, OVER | | | CURRENT PROTECTION ETC, NOT ENOUGH INFORMATION IS | | | SHOWN. | | | FIXTURE LOCATIONS ETC. | | | FBC 106.1.2, 106.3.5.1.2 | | | NEC240.4, 310.16, | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-25 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-25 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2007-08-25 18:12:45 | 2007-08-25 18:12:45 | | | | | | *** DENIED *** | | | | | | | | | ** PLEASE KNOW AS THERE ARE SOME ITEMS NOT YET | | | SUBMITTED FOR REVIEW THERE MAY VERY WELL BE NEW | | | COMMENTS ONCE SUBMITTED. | | | | | | 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH | | | ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | ** PLEASE KNOW THAT CHANGES FOR NEW CODES IS REQUIRED | | | FOR ALL TRADES AND FOR ALL REVIEWS EVEN IF COMMENT IS | | | NOT MADE BY OTHER TRADE(S). | | | | | | 2) NOTE: PLEASE SEE FBC EXISTING BUILDING CODE FOR | | | ELECTRICAL WHICH REFERENCES CHAPTER 27 OF THE FBC. | | | PLEASE SEE THE SCOPE OF WORK WELL EXCEEDS THE VALUE OF | | | THE 30% AS DEFINED FOR RENOVATIONS. | | | PLEASE SUBMIT THE COMPLETED ENERGY CALCULATIONS. PLEASE | | | SEE THE CERTIFICATION SHEET EVENS STATES NOT VALID WITH | | | OUT THE INPUT DATA REPORT. | | | PLEASE KNOW AT THIS TIME NOT REVIEW FOR LIGHTING | | | COMPLIANCE CAN BE DONE FOR INTERIOR AND EXTERIOR | | | LIGHTING POWER ALLOWANCES. PLEASE SEE 13-415.1.A, | | | 13-415.2, 13-415.2.ABC.1.2, 13-415.2.ABC.1.3, | | | 13-415.2.ABC.1.1 | | | | | | 3) NOTE: PLEASE SEE THE PLANS AND RISER ARE SHOWING A | | | NEW SERVICE FOR THIS PORTION OF THE BUILDING HOWEVER | | | THE AS THE PLANS INDICATE THIS A ONE BUILDING ALONG | | | WITH THE ADJACENT STRUCTURE ONE PROPERTY THE NEW | | | SERVICE AS SHOWN IS NOT GRANTED. | | | PLEASE PROVIDE STRUCTURAL INFORMATION FOR THE CONNECTED | | | TENANTS. | | | PLEASE SEE THIS WOULD REQUIRE A *FIRE WALL* AS DEFINED | | | IN THE BUILDING CODE WHICH NOT ONLY CONTAINS A FIRE | | | RATING BUT ALLOWS STRUCTURAL COLLAPSE ON ONE SIDE OR | | | THE OTHER WITHOUT AFFECT THE STRUCTURAL INTEGRITY OF | | | THE OTHER STRUCTURE. AS NO INFORMATION ON THE BUILDING | | | AND ADJACENT TENANT IS PROVIDED, UNABLE TO MAKE THE | | | DETERMINATION IF MEETING 230.2. | | | PLEASE SEE THE PLANS ALSO INDICATE ITEMS LOCATED ON THE | | | ADJACENT TENANT ROOF WHICH IS ACTUALLY FOR THIS | | | BUILDING?? | | | PLEASE KNOW THAT IF THIS IS CONSIDERED ONE BUILDING AND | | | IS ONLY FED FROM SERVICE THEN THIS IS OK, HOWEVER BASED | | | ON PLANS REQUESTED A SEPARATE SERVICE ALL ELECTRICAL | | | WHICH IS LOCATED ON THE ADJACENT STRUCTURE WOULD NOT BE | | | PERMITTED. | | | PLEASE ALSO SEE ONE OF THE COMMENTS BELOW WITH RESPECT | | | TO THE EGRESS STAIRS. | | | | | | 4) NOTE: PLEASE SEE NO DISCONNECT FOR MINI-SPLIT CU | | | SHOWN ON ROOF IS INDICATED ON PLANS. | | | PLEASE SHOW 440.1. | | | | | | 5) NOTE: PLEASE SEE MISSING ROOF TOP GFI AS REQUIRED | | | PER 210.63, 210.8B3 | | | | | | 6) NOTE: PLEASE SEE MISSING SHOW WINDOW RECEPTACLES FOR | | | WINDOWS AT THE FRONT OF THE STORE. | | | 210.62 | | | PLEASE BE SURE TO ADJUST LOAD CALCULATIONS PER 220.43 | | | | | | 7) NOTE: PLEASE SEE 600.5 AS THE MINIMUM VA FOR THE | | | SIGN CIRCUIT IS REQUIRED TO BE 1200 VA. BASED ON THE | | | AMPERAGE SHOWN ON PANEL SCHEDULE AT 120V THIS DOES NOT | | | SHOW THE MINIMUM LOAD AS NEEDED. | | | | | | 8) NOTE: PLEASE CLARIFY THE PANELS. THESE ARE SHOWN AS | | | 200MLO, YET THESE ARE SHOWN AS 42SPACES. | | | PLEASE VERIFY THE AVAILABILITY OF THESE TYPES OF | | | PANELS. THIS IS OK, HOWEVER IF THESE PANELS SHOWN AT 42 | | | SPACES ARE INDEED 225AMP RATED, THAN PLEASE REVISE | | | PLANS TO SHOW THIS. | | | ** THIS WOULD ALLEVIATE AND REVISIONS NEEDED AT A LATER | | | DATE. | | | | | | 9) NOTE: PLEASE CLARIFY THE COOLER AS THERE IS NO | | | LIGHTING PROVIDED ON PLANS., | | | FBC 106.1.2 (ADDITIONAL INFORMATION). | | | | | | 10) NOTE: PLEASE SEE MISSING INFORMATION ON THE TITLE | | | BLOCKS FOR THE ARCHITECT AS REQUIRED PER FAC | | | 61G1-16.004. | | | | | | 11) NOTE: PLEASE SUBMIT PHOTO-METRICS FOR STAIR AREAS | | | UNDER NORMAL AND UNDER EMERGENCY. | | | PLEASE SEE THAT THIS NEEDS TO INCLUDE THE EXTERIOR | | | STAIR TO THE PUBLIC RIGHT OF WAY. PLEASE PROVIDE | | | LIGHTING FIXTURES AND ALSO BATTERY BACK UP AS REQUIRED | | | UNDER THE MINIMUM REQUIREMENTS OF THE LIFE SAFETY | | | CODE. | | | PLEASE SEE NFPA-101 7.8.1.3, 7.9.2.2 | | | | | | 12) NOTE: PLEASE SEE 210.8B2 AS ALL 15 AND 20 AMP 120 | | | RECEPTACLES IN KITCHEN AND FOOD PREP AREAS ARE REQUIRED | | | TO BE GFI OR GFI PROTECTED. THIS DOES NOT MATTER IF | | | THESE FEED COUNTER SPACES OR NOT. | | | | | | 13) NOTE: PLEASE SUBMIT ELECTRICAL FOR THE 2ND FLOOR. | | | DUE TO THE SCOPE OF WORK, THIS AREA WOULD BE REQUIRED | | | TO MEET CODE. | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM THE FIRE MARSHAL | | | AND BUILDING REVIEWER FOR REQUIRED SMOKE ALARMS OR | | | SMOKE DETECTORS. | | | AS SHOWN ON PLANS, THIS AREA IS NOT PERMITTED TO BE | | | USED FOR SLEEPING/APARTMENT/RESIDENCE. IF SO, THEN | | | MINIMUM REQUIRED CIRCUITS AND ARC FAULT PROTECTION | | | WOULD BE REQUIRED. | | | FBC 106.1.2, 106.3.5.1.2 | | | NEC 2005. | | | | | | 14) NOTE: PLEASE INDICATE THE SIZE OF THE METER CAN. | | | FBC 106.1.2. | | | | | | 15) NOTE: PLANS INDICATE THERE IS GOING TO BE LANDSCAPE | | | LIGHTING HOWEVER NO ELECTRICAL SITE PLANS ARE SUBMITTED | | | SHOWING THE CIRCUITS, LIGHTING LOCATIONS ETC. PLEASE | | | COMPLETE. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-05-15 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-05-15 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-02-21 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-02-21 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2008-02-21 13:59:37 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1.POLLUTION PREVENTION PLAN:SILT FENCE AROUND YOUR | | | SITE SHOULDBE SHOWN ON THE DRAWING, BEFORE YOU START | | | CONSTRUCTION. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-11-27 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-11-27 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2007-11-27 13:17:07 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1 YOUR DUMPSTER DIMENSIONS ARE LESS THAN CITY | | | STANDARDS. SO, YOU NEED AN APPROVAL FROM SANITATION | | | DEPT.,NOTFROM ENGINEERING SERVICES DEPT. | | | 2. PLEASE SHOW TOTAL PERVIOUS,& IMPERVIOUS AREA FOR | | | THIS PROJECT,OR SEPARATELAKE,SIDEWALK, | | | PARKING,BUILDING AREA ETC. | | | 3. POLLUTION PREVENTION PLAN:SILT FENCE AROUND YOUR | | | SITE SHOULDBE SHOWN ON THE DRAWING IF YOU ARE | | | REPAIRING PARKING LOT AND OUTSIDE OF THE BUILDING. | | | PLEASE SHOW SILT FENCE DETAILS. HEIGHT OF THE SILT | | | FENCE SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & | | | PARTICLES. | | | 4. FOR YOUR INFO: IF YOU ARE REPAIRING ORPUTTING ANY | | | NEWCURB, SIDEWALK, ENTRANCE APPROACHES OUTSIDE OF | | | YOUR PROPERTY, YOU MUST NEED A CITY'S RIGHT OF WAY | | | APPROVAL FROM WINDEL PALMER 494-1040, 45TH STREET | | | ENGINEERING | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-09-11 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-09-11 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2007-09-11 15:44:30 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1.PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, SIDEWALK SLOPE,DRIVEWAY, APPROACH, | | | PARKINGS, HANDICAP PARKINGS, DUMPSTER ENCLOSURE, YOU | | | CAN GET A C D FROM 1000, 45 STREET FOR ALL THESE CITY | | | STANDARDS NOTES. PHONE# 494-1040 | | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB,LOCATION MUST BE ACCESSIBLE | | | FOR CITY PICKUP TRUCK. | | | 3. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE | | | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL | | | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, | | | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE | | | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED | | | IN STORM WATER QUALITY CALCULATIONS. | | | 4.PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES.PLEASE SHOW CALCULATION | | | FOR EXFILTRATION TRENCHES IN WATER QUALITY CALS. | | | PLEASE SHOW DRY DETENTION/WET DETENTION AREAS IN STORM | | | WATER CALS.WHERE STORM WATER GOES?? | | | 5. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | 6.PLEASE PROVIDE A COPY OF STORM WATER QUALITY | | | CALCULATIONS.STORM WATER CALS MUST BE APPROVED FROM | | | 100045TH STREET ENGINEERING SERVICES. | | | 7. POLLUTION PREVENTION PLAN: SILT FENCE AROUND YOUR | | | SITE MUST BE SHOWN ON THE DRAWING. PLEASE SHOW SILT | | | FENCE DETAILS. HEIGHT OF THE SILTFENCE SHOULD BE HIGH | | | ENOUGH PER FDEP TO STOP DUST & PARTICLES. | | | 8. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2008-11-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-11-17 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-11-17 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2008-11-17 15:18:49 | ***** REVISION #4, DATED 10/08/08, APPROVED***** | | | | | | REVISED PLAN SHEET A-2 STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-06-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-13 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-13 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2008-06-13 12:06:27 | *****APPROVED***** | | | | | | PLAN SHEETS A-2, A-3, AND A-4 WERE PREVIOUSLY | | | FIRE-STAMPED; SHEET E-1 STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-19 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-19 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2008-05-19 12:00:10 | *****PROVISO***** | | | | | | PLAN SHEETS A-2, A-3, AND A-4 WERE STAMPED, INITIALED, | | | AND DATED; HOWEVER, SHEET E-1 TO BE FIRE-STAMPED WHEN | | | THE ELECTRICAL REVIEW HAS BEEN SATISFIED, | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-27 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-27 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2008-02-27 15:24:46 | *****PROVISO***** | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | ALL THE OTHER REVIEWERS HAVE BEEN SATISFIED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-26 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-26 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2007-11-26 12:16:10 | *****PROVISO***** | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | ALL THE OTHER REVIEWERS HAVE BEEN SATISFIED AND THE | | | FOLLOWING COMMENT FROM THE PREVIOUS FIRE PLAN REVIEW | | | HAVE BEEN ADDRESSED: | | | | | | 08.THE EXISTING/REMAINING EXIT STAIR INSTALLATION AND | | | DISCHARGE OCCURS ON WHICH LEGAL PROPERTY 740 BELVEDERE | | | OR 736 BELVEDERE (ADULT ENTERTAINMENT CLUB).PLEASE | | | PROVIDE A LEGAL SURVEY. THIS MAY BE ACCOMPLISHED BY | | | ADDRESSINGZONING COMMENT# 5 | | | | | | | | | | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-18 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-18 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2007-09-18 18:34:05 | *****DENIED***** | | | | | | | | | 01.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL CDOMPLY WITH NFPA 241. | | | | | | 03.ON THE APPROPIATE EXTERIOR ELEVATION WHICH FRONTS | | | BELVEDERE ROAD, DISPLAY THE NUMERICAL ADDRESS ON THE | | | BUILDING.AS PER WEST PALM BEACH CODE, THE ADDRESS | | | NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT AND NO LESS | | | THAN 1" IN WIDTH. | | | | | | 04.SPECIFY THE NEW INTERIOR WALL AND CEILING FINISH | | | MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | SPECIFY THE INTERIOR FLOOR FINISH IN TERMS OF CLASS I | | | OR CLASS II. | | | | | | 05.PROVIDE A LIFE SAFETY PLAN SHOWING THE TRAVEL | | | DISTANCE TO THE EXITS.THE LOCATION OF THE 2A:10BC | | | FIRE EXTINGUISHER(S) WHICH SATIFIES THE 75' TRAVEL | | | DISTANCE CAN ALSO BE INCLUDED. | | | | | | 06.ALL FIRE RATED DOORS AND FIRE RATED WINDOWS SHALL | | | COMPLY WITH NFPA 80. | | | | | | 07.VERIFY/SUBMIT THE PRESCRIPTIVE STRENGHT FOR THE | | | HANDRAIL/GUARDRAIL FOR THE EXISTING/REMAINING EXIT | | | STAIR AS CODE COMPLIANT. | | | | | | 08.THE EXISTING/REMAINING EXIT STAIR INSTALLATION AND | | | DISCHARGE OCCURS ON WHICH LEGAL PROPERTY 740 BELVEDERE | | | OR 736 BELVEDERE (ADULT ENTERTAINMENT CLUB).PLEASE | | | PROVIDE A LEGAL SURVEY. | | | | | | 09.SPECIFY THE HAZARD OF THE CONTENTS OF THE STORAGE | | | ROOM IN TERMS OF LOW, ORDINARY, OR HIGH. | | | | | | 10.PLEASE PROVIDE THE CRITERIA/SPECIFICATIONS FOR THE | | | PROPOSED SPIRAL STAIRS COMPLYING WITH 7.2.2.2.3 OF THE | | | LIFE SAFETY CODE -NFPA 101. | | | | | | 11.COMMERCIAL COOKING EQUIPMENT SHALL BE IN | | | ACCORDANCE WITH NFPA 96 - 2001 EDITION.SEPARATE PLANS | | | AND PERMIT WILL BE REQUIRED FOR THE BOTH THE | | | INSTALLATION OF THE COOKING HOOD AND THE COOKING HOOD'S | | | SUPPRESSION SYSTEM. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
7 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-24 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-24 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2008-11-24 15:03:16 | GAS REVISIONS OK -- SHTS MP-1 & MP-2 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-24 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-19 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2008-11-24 15:02:36 | REVISION DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. -- REVISED RISER DIAGARM DOES NOT | | | REFLECT THE FLOOR PLAN. FLOOR PLAN | | | SHOWS THE GAS LINE INTO THE BUILDING AND AT THE FIRST | | | RISER SHOWS NO PIPING TO THE RANGE, FRYERS ETC., BUT | | | THE RISER DIAGRAM SHOWS A LINE BACK TO THE RANGE, | | | FRYERS ETC. PLEASE CORRELATE. | | | | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). -- NEW RISER ADDITION | | | SHOWS THE MOST REMOTE OUTLET AT 65 FEET. PLEASE CHANGE | | | INFORMATION. | | | | | | 3. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. -- THE PIPE SIZES | | | ARE NOT CORRECT. 2" PIPE IS REQUIRED UP TO THE TEE PAST | | | THE SHUT OFF VALVE AND THE EMERGENCY SHUT OFF VALVE. | | | MINIMUM 1-1/4" IS REQUIRED UP TO THE DEEP FRYER. 1" IS | | | REQUIRED UP TO THE SIMMERING COOKER. 1-1/4" IS REQUIRED | | | TO THE WATER HEATER. 1" IS REQUIRED TO THE SINGLE RACK | | | OVEN AND THE MINI RACK OVENS. PLEASE SHOW ALL CORRECT | | | PIPE SIZES. TABLE 402.4(2). | | | | | | 4. GAS PIPING SHALL BE SLEEVED AS IT ENTERS THE | | | BUILDING. SECTION 404.4. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-04 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-04 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2008-11-04 12:05:49 | REVISION DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. -- REVISED RISER DIAGARM DOES NOT | | | REFLECT THE FLOOR PLAN. FLOOR PLAN | | | SHOWS THE GAS LINE INTO THE BUILDING AND AT THE FIRST | | | RISER SHOWS NO PIPING TO THE RANGE, FRYERS ETC., BUT | | | THE RISER DIAGRAM SHOWS A LINE BACK TO THE RANGE, | | | FRYERS ETC. PLEASE CORRELATE. | | | | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). -- NEW RISER ADDITION | | | SHOWS THE MOST REMOTE OUTLET AT 65 FEET. PLEASE CHANGE | | | INFORMATION. | | | | | | 3. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. -- THE PIPE SIZES | | | ARE NOT CORRECT. 2" PIPE IS REQUIRED UP TO THE TEE PAST | | | THE SHUT OFF VALVE AND THE EMERGENCY SHUT OFF VALVE. | | | MINIMUM 1-1/4" IS REQUIRED UP TO THE DEEP FRYER. 1" IS | | | REQUIRED UP TO THE SIMMERING COOKER. 1-1/4" IS REQUIRED | | | TO THE WATER HEATER. 1" IS REQUIRED TO THE SINGLE RACK | | | OVEN AND THE MINI RACK OVENS. PLEASE SHOW ALL CORRECT | | | PIPE SIZES. TABLE 402.4(2). | | | | | | 4. GAS PIPING SHALL BE SLEEVED AS IT ENTERS THE | | | BUILDING. SECTION 404.4. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-24 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-24 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2008-06-24 14:55:01 | ****************PROVISO**************** | | | PER FBC-2004 FUEL GAS TABLE 402.4(2) THE GAS PIPE FOR | | | THE 250,000 BTU WATER HEATER SHALL BE 1". | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-16 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-15 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2008-05-16 11:22:57 | PASSED/PROVISO | | | | | | 1" PIPE REQUIRED FOR THE MINI RACK OVEN AND 1" REQUIRED | | | FOR THE SINGLE RACK OVEN.--REVISIONS REQUIRED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-25 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-25 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2008-02-25 14:10:54 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | ******FROM PREVIOUS REVIEW: | | | | | | ********NEW COMMENTS********** | | | (MISSED THE GAS REVIEW THE FIRST TIME THROUGH) | | | | | | 1B. A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT THE | | | FOLLOWING INFORMATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. RISER DOES NOT SHOW THE CUT LENGTH | | | SECTIONS, NOR DOES IT REFLECT THE FLOOR PLAN. | | | ******RESPONSE NOTED, BUT THE RISER STILL DOES NOT | | | REFLECT THE FLOOR PLAN, NOR DOES THE RISER SHOW ALL THE | | | CUT LENGTH SECTIONS. SEE THE SECTIONS THAT COME OFF THE | | | METER VERTICALLY, TURN HORIZONTAL, DROP DOWN | | | UNDERGROUND THEN TURN HORIZONTAL. ALSO THE SECTIONS OF | | | PIPE THAT TURNS TOWARD THE BUILDING, UP PAST THE SHUT | | | OFF VALVE, HORIZONTALL, THEN DROPS DOWN TO 4 FEET ABOVE | | | THE FLOOR FOR THE KITCHEN APPLIANCES. ALSO SEE THE CUT | | | SECTIONS OFF THE MAIN TO THE DOUBLE RACH OVEN AND THE | | | CUT SECTIONS TO THE WATER HEATER. | | | | | | B. OK | | | C. OK | | | D. OK | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (TO BE VERIFIED WHEN | | | COMMENT A IS SUBMITTED). | | | ******RESPONSE NOTED, BUT AS INDICATED IN THE LAST | | | REVIEW, THIS WILL BE VERIFIED WHEN ALL CUT SECTIONS ARE | | | GIVEN FOR COMMENT "A". | | | | | | F. OK | | | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ******RESPONSE NOTED, BUT NO MANUFACTURE SHEETS WERE | | | SUBMITTED FOR THE STEAMER OR THE WATER HEATER. | | | | | | H. N/A | | | I. N/A | | | | | | J. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | ******RESPONSE NOTED, BUT AN EMERGENCY HOOD SHUT DOWN | | | SHUT OFF VALVE IS REQUIRED AS WELL AS A UNION EITHER | | | BETEWEEN THE SHUT OFF VALVE AND THE EMERGNECY HOOD SHUT | | | OFF VALVE OR DOWN STREAM OF THE EMERGENCY SHUT OFF | | | VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-05 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-05 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2007-12-05 15:46:28 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT THE | | | FOLLOWING INFORMATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. RISER DOES NOT SHOW THE CUT LENGTH | | | SECTIONS, NOR DOES IT REFLECT THE FLOOR PLAN. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (TO BE VERIFIED WHEN | | | COMMENT A IS SUBMITTED). | | | | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | H. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | I. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | J. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE,IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-20 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-20 |
Time |
13:44 |
Sent To |
M |
|
| Notes |
| 2009-01-20 13:44:53 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-17 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-17 |
Time |
11:05 |
Sent To |
Z |
|
| Notes |
| 2008-12-17 11:06:03 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-24 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-24 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2008-11-24 10:54:54 | TO "COMM" BD#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-04 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-04 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2008-11-04 16:09:56 | TO "COMM" BD#21 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-22 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-22 |
Time |
08:53 |
Sent To |
B |
|
| Notes |
| 2008-10-22 08:54:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-10-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-20 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-20 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2008-10-21 13:43:43 | TO "COMM" BD#42 | | 2008-10-20 11:05:31 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-25 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-25 |
Time |
11:39 |
Sent To |
B |
|
| Notes |
| 2008-08-25 11:40:33 | TO BUILD. SAMANTHA H. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-20 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-20 |
Time |
16:16 |
Sent To |
B |
|
| Notes |
| 2008-08-20 16:17:13 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
08:33 |
Sent To |
P |
|
| Notes |
| 2008-07-11 08:33:44 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-30 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-30 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2008-05-30 12:26:23 | TO "COMM" BD#59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-01 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-01 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2008-05-01 16:13:21 | TO "COMM" BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-29 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-29 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2008-01-29 14:55:56 | TO "COMM" BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-22 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-22 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2007-11-07 13:07:33 | TO "COMM" BD#60 | | 2007-10-22 10:39:15 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-18 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-31 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2007-08-14 14:45:59 | TO "COMM" BD#52 | | 2007-07-31 15:27:08 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2008-12-18 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-12-18 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-12-18 |
Time |
13:30 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-02-03 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-02-03 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-24 |
Time |
19:45 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-24 |
Time |
19:45 |
Sent To |
PC |
|
| Notes |
| 2008-11-24 19:45:21 | REV MP-1 AND MP-2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2008-11-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-15 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-15 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2008-11-15 13:24:11 | MECH REVISION #6 OK. PLANS CANNOT BE STAMPED UNTIL | | | PLUMBING REVIEW HAS PASSED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-19 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-19 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-02-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-02-16 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-02-16 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-12-03 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-12-01 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2007-12-03 10:49:46 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. PREVIOUS COMMENT REQUESTED OUTSIDE AIR CALCULATIONS | | | FOR ALL AREAS, NOT JUST CUSTOMER AREA. KITCHEN AREA AND | | | 2ND FLOOR AREA CALCULATIONS ARE ALSO REQUIRED. | | | NOTE: 2ND FLOOR AREA IS PART OF LEVEL 2 ALTERATION AS | | | THERE ARE WINDOW OPENINGS BEING CLOSED. LEVEL 2 | | | ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE | | | ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW PER FBC, | | | EB 304.1. SHOW HOW OUTSIDE AIR REQUIREMENTS FOR THESE | | | AREAS ARE TO BE MET IN ACCORDANCE WITH FBC, M 403.3. | | | | | | 4. OK. VENTING INSTALLATION INSTRUCTIONS REQUIRED ON | | | SITE FOR INSPECTION. | | | | | | 5. RUSKIN SUBMITTAL FOUND IN PACKAGE. PRODUCT APPROVAL | | | OR NOA WAS NOT PROVIDED IN PACKAGE. THE NOA FOR THIS | | | LOUVER WAS PRINTED BY THIS OFFICE AND ADDED TO THE | | | PACKAGE. THIS WILL NOT BE DONE IN THE FUTURE. THIS | | | INFORMATION SHALL BE PROVIDED BY THE DESIGNER OR | | | CONTRACTOR. | | | | | | 6. OK | | | | | | 7. OK | | | | | | 8. OK. SEE COMMENT 3 ABOVE REGARDING 2ND FLOOR. | | | | | | NEW COMMENTS: | | | THE FOLLOWING COMMENTS HAVE BEEN GENERATED AS A RESULT | | | OF CHANGES TO THE PLANS AND/OR NEW INFORMATION WHICH | | | WAS NOT PART OF PREVIOUS SUBMITTAL. | | | | | | A. DETAIL #2 ON MP-1 SHOWS TWO ROOF CONDENSERS SITTING | | | ON CONCRETE PADS. HAS THERE BEEN AN ENGINEERING | | | ANALYSIS OF THE ROOF FRAMING TO VERIFY THAT IT IS | | | SUITABLE FOR THE ADDITIONAL DEAD LOADS OF THE EQUIPMENT | | | AND SIZEABLE 4 INCH THICK CONCRETE PADS? | | | | | | B. THERE IS NO DETAIL FOR HOW THE CONDENSING UNITS ARE | | | TO BE FASTENED TO THE CONCRETE PADS TO MEET 140 MPH | | | WIND LOADS IN ACCORDANCE WITH FBC, M 301.13 AND FBC | | | 1609. PLEASE NOTE THAT THE PRESCRIPTIVE METHOD SHOWN IN | | | FBC, M 301.13.1 IS FOR R-3 OCCUPANCY ONLY. ENGINEERING | | | IS REQUIRED. | | | | | | C. PG S-3 SHOWS A CONNECTION DETAIL FOR ROOFTOP | | | CONDENSERS WHICH IS IN CONFLICT WITH DETAIL #2 ON MP-1. | | | WHICH METHOD IS TO BE USED? ALSO, DETAIL ON S-3 REFERS | | | TO A PRODUCT APPROVAL FOR AN A/C STAND. NO SUCH PRODUCT | | | APPROVAL WAS FOUND IN THE SUBMITTAL PACKAGE FOR THIS | | | PERMIT. DETERMINE WHICH METHOD IS TO BE USED AND | | | PROVIDE ALL REQUIRED DOCUMENTATION TO SHOW COMPLIANCE | | | WITH THESE SECTIONS. | | | | | | NOTE: DOCUMENTATION FOR TYPE I KITCHEN HOOD AND DUCT | | | SYSTEM HAVE NOT BEEN PROVIDED. FULL DOCUMENTATION FOR | | | HOOD PERMIT WILL BE REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-21 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-21 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2007-08-21 16:37:55 | REVIEW #: 1 | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. A LEVEL OF ALTERATION IS TO BE DECLARED IN | | | ACCORDANCE WITH FBC,EB 301.5. INCLUDE THIS INFORMATION | | | IN THE BUILDING DATA ON A-1. THIS APPEARS TO BE A LEVEL | | | 3 ALTERATION. | | | | | | 2. THIS BUILDING IS CONSIDERED A RENOVATION UNDER THE | | | DEFINITION OF A RENOVATION IN FBC 13-202 AS THE VALUE | | | OF THE PROPOSED IMPROVEMENT IS ABOVE THE THRESHOLD OF | | | 30% OF THE STRUCTURES VALUE OF $220,746. SEE PROPERTY | | | APPRAISER DATA (ATTACHED). RENOVATED BUILDINGS SHALL | | | COMPLY WITH THE PRESCRIPTIVE REQUIREMENTS CONTAINED IN | | | FORM 400C OR WITH METHOD B OF SUBCHAPTER 13-4 FOR | | | INSULATION, HVAC SYSTEMS, LIGHTING, WATER HEATING | | | SYSTEMS AND EXTERIOR ENVELOPE COMPONENTS BEING | | | RETROFITTED OR REPLACED. FBC 13-101.1.3. PROVIDE FORM | | | 400C OR 400B TO SHOW COMPLIANCE. FORM 400A IS NOT AN | | | OPTION FOR THIS TYPE OF PROJECT. | | | | | | 3. ALL VENTILATION REQUIREMENTS OF FBC,M CHAPTER 4 AND | | | THE EXHAUST REQUIREMENTS OF FBC,M CHAPTER 5 SHALL BE | | | MET PER FBC, EB 609.1. PROVIDE OUTDOOR AIR CALCULATIONS | | | SHOWING OCCUPANCY CLASSIFICATION, OCCUPANT LOAD AND CFM | | | OF OUTDOOR AIR REQUIRED/PROVIDED FOR ALL AREAS PER | | | FBC,M TABLE 403.3. | | | | | | 4. PROVIDE A TYPE II COMMERCIAL KITCHEN EXHAUST HOOD | | | OVER THE OVENS PER FBC,M 507.2. | | | | | | 5. OUTDOOR WALL LOUVERS ARE SUBJECT TO FAC RULE 9B-72 | | | AND AS SUCH. PRODUCT APPROVAL IS REQUIRED. PROVIDE | | | SPECIFIC PRODUCT APPROVAL FOR THE MANUFACTURER AND | | | MODEL OF LOUVERS TO BE USED. FOR MORE INFORMATION ON | | | THE FLORIDA PRODUCT APPROVAL SYSTEM PLEASE VISIT: | | | WWW.FLORIDABUILDING.ORG | | | | | | 6. SHOW ON PLANS THE MEANS AND LOCATION OF CONDENSATE | | | DISPOSAL. THE LOCATION SHALL COMPLY WITH FBC,M 307.2.1 | | | AND FBC 1503.6. IT SHALL NOT DISCHARGE ONTO ASPHALT AS | | | DESCRIBED IN PLUMBING GENERAL NOTE #18. | | | | | | 7. SHOW MEANS OF AUXILIARY OR SECONDARY DRAIN | | | PROTECTION IN ACCORDANCE WITH FBC,M 307.2.3. A WATER | | | LEVEL DETECTION DEVICE I(FLOAT SWITCH) N THE SECONDARY | | | DRAIN PAN WILL MET THIS REQUIREMENT. | | | | | | 8. SECOND FLOOR HVAC PLAN STATES "SEE NOTE #1" BUT NO | | | NOTE COULD BE FOUND RELATED TO THIS AREA. PLEASE | | | CLARIFY. | | | | | | NOTE: SEPARATE PERMITS ARE REQUIRED FOR THE HOODS, HOOD | | | SUPPRESSION SYSTEM(S) AND THE WALK-IN COOLERS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-24 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-24 |
Time |
15:03 |
Sent To |
M |
|
| Notes |
| 2008-11-24 15:04:21 | PLUMBING REVISIONS OK -- SHTS MP-1 & MP-2. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-24 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-19 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2008-11-24 14:57:55 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | CITY WPB MUNICIPAL CODE | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | 1. SHT MP-1 REVISION #5 INDICATED IN THE REVISION INDEX | | | HAS NOT BEEN FOUND ON THE FLOOR PLAN. (THIS WAS A | | | COMMENT FROM THE PREVIOUS REVISION SUBMITTED). SECTION | | | 106.1.3. PLEASE INDICATE WHERE REVISION #5 IS ON THE | | | FLOOR PLAN. SHOW WITH A CLOUD AND NUMBERED TRIANGLE. | | | | | | 2. SHT MP-1 MANY CHANGES DETECTED ON THE SHEET WITH NO | | | CLOUDS OR NUMBERED TRIANGLES. ALL REVISIONS SHALL BE | | | INDICATED WITH CLOUDS AND NUMBERED TRIANGLES. IF THERE | | | ARE MANY REVISIONS THEN CLOUD THE COMPLETE FLOOR PLAN, | | | BUT PLEASE INDICATE ALL REVISIONS. SECTION 106.1.3. | | | | | | 3. SHT MP-1 INDICATE IF THE 3 COMPARTMENT OR THE 2 | | | COMPARTMENT SINKS ARE UTILIZIED FOR STORAGE, | | | PREPARATION OR HANDLING OF FOOD. IF SO THE SINK/SINKS | | | SHALL DISCHARGE THROUGH AN INDIRECT WASTE PIPE BY MEANS | | | OF AN AIR GAP. SECTION 802.1.1. SECTION 106.1.2. | | | | | | 4. SHT MP-2 MANY REVISIONS/CHANGES SHOWN ON THE RISER | | | DIAGRAMS ARE NOT CLOUDED OR NUMBERED. ALL REVISIONS | | | SHALL BE INDICATED WITH CLOUDS AND NUMBERED TRIANGLES. | | | SECTION 106.1.3. | | | | | | 5. SHT MP-2 WATER RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN FOR THE SUPPLY PIPING TO THE DRINKING | | | FOUNTAIN. THE FLOOR PLAN SHOWS THE WATER SUPPLY LOCATED | | | THRU THE CABINETS, BUT THE RISER DIAGRAM SHOWS A DROP | | | FROM THE CEILING ON THE RISER AT THE DRINKING FOUNTAIN. | | | PLEASE CORRELATE. SECTIONS 106.1.1 & 601.1. | | | | | | 6. SHT MP-2 WATER RISER DIAGRAM. ALL HOSE BIBBS SHALL | | | HAVE A SHUT OFF VALVE ON THE SUPPLY LINE TO THE HOSE | | | BIBBS. SECTION 606.2(2). | | | | | | 7. SHT MP-2 SANITARY/GREASE RISER DIAGRAM. THE BYPASS | | | LINE AT THE GREASE INTERCEPTOR IS NOT APPROVED AND DOES | | | NOT REFLECT THE FLOOR PLAN. ARTICLE III SECTION | | | 90-124(7) & SECTION 106.1.1. | | | | | | 8. SHT MP-2 SANITARY/GREASE RISER DIAGRAM. THE 2 | | | COMPARTMENT SINK DRAIN LINE THAT USED TO CONNECT TO THE | | | 3 COMPARTMENT SINK IS NOW A DEAD END. DEAD ENDS ARE NOT | | | APPROVED. PLEASE DELETE OR USE FOR ONE SIDE OF THE 2 | | | COMPARTMENT SINK SO IT CAN DRAIN INTO THE DRAIN LINE | | | AND THE AAV REINSTALLED AT THE TOP OF THE LINE. SECTION | | | 704.5. | | | | | | 9. SHT MP-2 SANITARY/GREASE RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN AT THE 2 COMPARTMENT SINK. THE | | | FLOOR PLAN DOES NOT SHOW THE WASTE ARMS TO THE SINK | | | TRAPS. | | | | | | (SEE COMMENTS FOR GAS REVIEW IN GAS STOP). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-04 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-03 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2008-11-04 11:48:57 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | CITY WPB MUNICIPAL CODE | | | | | | 1. SHT MP-1 REVISION #5 INDICATED IN THE REVISION INDEX | | | HAS NOT BEEN FOUND ON THE FLOOR PLAN. (THIS WAS A | | | COMMENT FROM THE PREVIOUS REVISION SUBMITTED). SECTION | | | 106.1.3. PLEASE INDICATE WHERE REVISION #5 IS ON THE | | | FLOOR PLAN. SHOW WITH A CLOUD AND NUMBERED TRIANGLE. | | | | | | 2. SHT MP-1 MANY CHANGES DETECTED ON THE SHEET WITH NO | | | CLOUDS OR NUMBERED TRIANGLES. ALL REVISIONS SHALL BE | | | INDICATED WITH CLOUDS AND NUMBERED TRIANGLES. IF THERE | | | ARE MANY REVISIONS THEN CLOUD THE COMPLETE FLOOR PLAN, | | | BUT PLEASE INDICATE ALL REVISIONS. SECTION 106.1.3. | | | | | | 3. SHT MP-1 INDICATE IF THE 3 COMPARTMENT OR THE 2 | | | COMPARTMENT SINKS ARE UTILIZIED FOR STORAGE, | | | PREPARATION OR HANDLING OF FOOD. IF SO THE SINK/SINKS | | | SHALL DISCHARGE THROUGH AN INDIRECT WASTE PIPE BY MEANS | | | OF AN AIR GAP. SECTION 802.1.1. SECTION 106.1.2. | | | | | | 4. SHT MP-2 MANY REVISIONS/CHANGES SHOWN ON THE RISER | | | DIAGRAMS ARE NOT CLOUDED OR NUMBERED. ALL REVISIONS | | | SHALL BE INDICATED WITH CLOUDS AND NUMBERED TRIANGLES. | | | SECTION 106.1.3. | | | | | | 5. SHT MP-2 WATER RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN FOR THE SUPPLY PIPING TO THE DRINKING | | | FOUNTAIN. THE FLOOR PLAN SHOWS THE WATER SUPPLY LOCATED | | | THRU THE CABINETS, BUT THE RISER DIAGRAM SHOWS A DROP | | | FROM THE CEILING ON THE RISER AT THE DRINKING FOUNTAIN. | | | PLEASE CORRELATE. SECTIONS 106.1.1 & 601.1. | | | | | | 6. SHT MP-2 WATER RISER DIAGRAM. ALL HOSE BIBBS SHALL | | | HAVE A SHUT OFF VALVE ON THE SUPPLY LINE TO THE HOSE | | | BIBBS. SECTION 606.2(2). | | | | | | 7. SHT MP-2 SANITARY/GREASE RISER DIAGRAM. THE BYPASS | | | LINE AT THE GREASE INTERCEPTOR IS NOT APPROVED AND DOES | | | NOT REFLECT THE FLOOR PLAN. ARTICLE III SECTION | | | 90-124(7) & SECTION 106.1.1. | | | | | | 8. SHT MP-2 SANITARY/GREASE RISER DIAGRAM. THE 2 | | | COMPARTMENT SINK DRAIN LINE THAT USED TO CONNECT TO THE | | | 3 COMPARTMENT SINK IS NOW A DEAD END. DEAD ENDS ARE NOT | | | APPROVED. PLEASE DELETE OR USE FOR ONE SIDE OF THE 2 | | | COMPARTMENT SINK SO IT CAN DRAIN INTO THE DRAIN LINE | | | AND THE AAV REINSTALLED AT THE TOP OF THE LINE. SECTION | | | 704.5. | | | | | | 9. SHT MP-2 SANITARY/GREASE RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN AT THE 2 COMPARTMENT SINK. THE | | | FLOOR PLAN DOES NOT SHOW THE WASTE ARMS TO THE SINK | | | TRAPS. | | | | | | (SEE COMMENTS FOR GAS REVIEW IN GAS STOP). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-23 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-23 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2008-07-23 15:03:28 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FLORIDA STATUTES | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT MP-1 REVISIONS TO A PLAN SIGNED AND SEALED BY A | | | PROFESSIONAL ENGINEER SHALL BE SIGNED AND SEALED BY THE | | | ENGINEER OF RECORD. FS 471.--REVISION #5 IS NOT | | | CLOUDED NOR INDICATED WITH A REVISION NUMBER.--ANY | | | CHANGE TO A SANITARY SYSTEM INDICATED ON THE FLOOR PLAN | | | SHALL BE REFLECTED WITH A REVISION TO THE SANITARY | | | RISER DIAGRAM AS WELL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-24 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-24 |
Time |
14:50 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-16 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-15 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-25 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-25 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2008-02-25 14:08:38 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 EXISTING BUILDING CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: | | | | | | 1. ARCHITECTURAL SHEETS. THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT SHALL BE INDICATED IN THE TITLE | | | BLOCK PER FAC 61G1-16.004(6) & FS 481.2055. | | | ****RESPONSE NOTED, BUT DOES NOT ADDRESS THE COMMENT | | | FOR THE PRINTED NAME OF THE PERSON SEALING THE DOCUMENT | | | ON THE ARCHITECTURAL SHEETS. | | | ******NO RESPONSE NOTED, BUT THE PRINTED NAME IS NOT | | | SHOWN ON SHT A-4. | | | | | | 2. OK | | | 3. OK | | | 4. OK | | | | | | 5. SHT A-2DETAIL 1/A-2, THE TOILET ROOM SHALL BE | | | ACCESSIBLE PER SECTION 806.1 OF THE EXISTING BUILDING | | | CODE. SUBMIT DETAILS/ELEVATIONS SHOWING COMPLIANCE WITH | | | SECTION 11-4.22 & ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT THE FOLLOWING HAS NOT BEEN | | | ADDRESSED: | | | ___FOR THE W/C: | | | A. OK | | | B. 11-4.16.5 FLUSH CONTROLS | | | ******NO RESPONSE NOTED, NOT ADDRESSED. | | | ___FOR THE URINAL: | | | A. OK | | | B. 11-4.18.4 FLUSH CONTROLS | | | ******NO RESPONSE NOTED, NOT ADDRESSED. | | | ___FOR THE LAV: | | | A. OK | | | B. OK | | | | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. OK | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK | | | 14. OK | | | 15. OK | | | 16. OK | | | | | | ********NEW COMMENTS********** | | | (MISSED THE GAS REVIEW THE FIRST TIME THROUGH) | | | | | | 1B. A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT THE | | | FOLLOWING INFORMATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. RISER DOES NOT SHOW THE CUT LENGTH | | | SECTIONS, NOR DOES IT REFLECT THE FLOOR PLAN. | | | ******RESPONSE NOTED, BUT THE RISER STILL DOES NOT | | | REFLECT THE FLOOR PLAN, NOR DOES THE RISER SHOW ALL THE | | | CUT LENGTH SECTIONS. SEE THE SECTIONS THAT COME OFF THE | | | METER VERTICALLY, TURN HORIZONTAL, DROP DOWN | | | UNDERGROUND THEN TURN HORIZONTAL. ALSO THE SECTIONS OF | | | PIPE THAT TURNS TOWARD THE BUILDING, UP PAST THE SHUT | | | OFF VALVE, HORIZONTALL, THEN DROPS DOWN TO 4 FEET ABOVE | | | THE FLOOR FOR THE KITCHEN APPLIANCES. ALSO SEE THE CUT | | | SECTIONS OFF THE MAIN TO THE DOUBLE RACK OVEN AND THE | | | CUT SECTIONS TO THE WATER HEATER. | | | | | | B. OK | | | C. OK | | | D. OK | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (TO BE VERIFIED WHEN | | | COMMENT A IS SUBMITTED). | | | ******RESPONSE NOTED, BUT AS INDICATED IN THE LAST | | | REVIEW, THIS WILL BE VERIFIED WHEN ALL CUT SECTIONS ARE | | | GIVEN FOR COMMENT "A". | | | | | | F. OK | | | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ******RESPONSE NOTED, BUT NO MANUFACTURE SHEETS WERE | | | SUBMITTED FOR THE STEAMER OR THE WATER HEATER. | | | | | | H. N/A | | | I. N/A | | | | | | J. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | ******RESPONSE NOTED, BUT AN EMERGENCY HOOD SHUT DOWN | | | SHUT OFF VALVE IS REQUIRED AS WELL AS A UNION EITHER | | | BETEWEEN THE SHUT OFF VALVE AND THE EMERGNECY HOOD SHUT | | | OFF VALVE OR DOWN STREAM OF THE EMERGENCY SHUT OFF | | | VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-05 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-05 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2007-12-05 15:43:27 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 EXISTING BUILDING CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. ARCHITECTURAL SHEETS. THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT SHALL BE INDICATED IN THE TITLE | | | BLOCK PER FAC 61G1-16.004(6) & FS 481.2055. | | | ****RESPONSE NOTED, BUT DOES NOT ADDRESS THE COMMENT | | | FOR THE PRINTED NAME OF THE PERSON SEALING THE DOCUMENT | | | ON THE ARCHITECTURAL SHEETS. | | | | | | 2. OK | | | | | | 3. TABLE 403.1 REQUIRES A DRINKING FOUNTAIN. PLEASE | | | INDICATE THE LOCATION OF THE DRINKING FOUNTAIN AND | | | SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.15 | | | AND ALL SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A) | | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | ****RESPONSE NOTED, BUT SECTION 11-4.1.3(10)(A) HAS NOT | | | BEEN ADDRESSED. | | | | | | 4. OK | | | | | | 5. SHT A-2DETAIL 1/A-2, THE TOILET ROOM SHALL BE | | | ACCESSIBLE PER SECTION 806.1 OF THE EXISTING BUILDING | | | CODE. SUBMIT DETAILS/ELEVATIONS SHOWING COMPLIANCE WITH | | | SECTION 11-4.22 & ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT THE FOLLOWING HAS NOT BEEN | | | ADDRESSED: | | | ___FOR THE W/C: | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.5 FLUSH CONTROLS | | | ___FOR THE URINAL: | | | A. 11-4.18.3 CLEAR FLOOR SPACE | | | B. 11-4.18.4 FLUSH CONTROLS | | | ___FOR THE LAV: | | | A. 11-4.19.3 CLEAR FLOOR SPACE | | | B. 11-4.19.5 FAUCETS | | | (NOTE: THE DOOR SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTURE). | | | | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. OK | | | 10. OK | | | | | | 11. SHT MP-1 NOTES FOR GREASE INTERCEPTOR: NOTE 6. | | | GREASE INTERCEPTORS ARE TO BE SIZED BY ENVIRONMENTAL | | | COMPLIANCE SECTION OF THE UTILITY DEPT. PLEASE CONTACT | | | RODNEY COMPO, (561) 822-2272, E-MAIL [email protected], OR | | | CALVIN WILLIAMS, (561) 822-2284, E-MAIL | | | [email protected]. THEIR FAX NUMBER IS (561) 822-2287. | | | A WRITTEN VERIFICATION FROM ENVIRONMENTAL COMPLIANCE | | | SHALL BE SUBMITTED WITH PLANS FOR GREASE INTERCEPTOR | | | APPROVAL. | | | ****RESPONSE NOTED, BUT NO WRITTEN DOCUMENTATION | | | SUBMITTED. | | | | | | 12. OK | | | 13. OK | | | 14. OK | | | 15. OK | | | 16. OK | | | | | | ********NEW COMMENTS********** | | | (MISSED THE GAS REVIEW THE FIRST TIME THROUGH) | | | | | | 1B. A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT THE | | | FOLLOWING INFORMATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. RISER DOES NOT SHOW THE CUT LENGTH | | | SECTIONS, NOR DOES IT REFLECT THE FLOOR PLAN. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (TO BE VERIFIED WHEN | | | COMMENT A IS SUBMITTED). | | | | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | H. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | I. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | J. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE,IDENTIFYING THE | | | SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-07 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-07 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2007-09-07 17:07:53 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 EXISTING BUILDING CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ARCHITECTURAL SHEETS. THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT SHALL BE INDICATED IN THE TITLE | | | BLOCK PER FAC 61G1-16.004(6) & FS 481.2055. | | | | | | 2. SHT A-2 DETAIL 1/A-2 CUSTOMERS, PATRONS & VISITORS | | | SHALL BE PROVIDED WITH PUBLIC TOILET FACILITIES IN | | | STRUCTURES & TENANT SPACES INTENDED FOR PUBLIC | | | UTILIZATION. PLEASE PROVIDE TOILET FACILITIES. SECTION | | | 403.6. | | | | | | 3. TABLE 403.1 REQUIRES A DRINKING FOUNTAIN. PLEASE | | | INDICATE THE LOCATION OF THE DRINKING FOUNTAIN AND | | | SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.15 | | | AND ALL SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A) | | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | | | | 4. INDICATE THE ALTERATION LEVEL PER SECTIONS 303, 304 | | | OR 305 OF THE EXISTING BUILDING CODE. | | | | | | 5. SHT A-2DETAIL 1/A-2, THE TOILET ROOM SHALL BE | | | ACCESSIBLE PER SECTION 806.1 OF THE EXISTING BUILDING | | | CODE. SUBMIT DETAILS/ELEVATIONS SHOWING COMPLIANCE WITH | | | SECTION 11-4.22 & ALL SUBSECTIONS. | | | | | | 6. SHT A-2DETAIL 2/A-2 THE BATHROOM, (RM 201), SHALL | | | BE ACCESSIBLE. PER SECTION 806.1 OF THE EXISTING | | | BUILDING CODE. SUBMIT DETAILS/ELEVATIONS SHOWING | | | COMPLIANCE WITH SECTION 11-4.23 AND ALL SUBSECTIONS. | | | | | | 7. SUBMIT A ROOF DETAIL. SINCE THERE HAS BEEN ADDED | | | VERTICAL WALLS AND ROOF AREA DRAINING ONTO THE ROOF | | | FROM ABOVE, THE ROOF DRAINAGE REQUIREMENTS SHALL BE | | | REVIEWED. SHOW THE LOCATIONS FOR ALL THE PRIMARY AND | | | SECONDARY ROOF DRAINS AND INDICATE THE SIZE OF ALL | | | DRAINS. INDICATE THE SLOPE OF THE ROOF TO THE ROOF | | | DRAINS. SUBMIT CALCULATIONS FOR THE PRIMARY AND | | | SECONDARY ROOF DRAINS. SHOW THE SQUARE FOOTAGE BEING | | | DRAINED AT EACH ROOF DRAIN ALONG WITH 1/2 AREA OF ALL | | | VERTICAL WALLS INCLUDING PARAPETS AS WELL AS ANY ROOF | | | AREA THAT DRAINS ONTO THE ROOF FROM ABOVE FOR EACH | | | AREA. SECTIONS 1106 & 1107 WITH ALL SUBSECTIONS AND | | | TABLES. SECTION 106.1.2. | | | | | | 8. SHT A-4 FINISH SCHEDULE, ROOM 201 SHALL MEET THE | | | REQUIREMENTS OF SECTION 1210.1 & 1210.2. PLEASE SHOW ON | | | THE FINISH SCHEDULE. | | | | | | 9. SHTS S-1 THRU S-4 THE ENGINEER SHALL LEGIBLY | | | INDICATE THEIR ADDRESS AS WELL AS THE ADDRESS OF THE | | | ENGINEERING BUSINESS IN THE TITLE BLOCKS. FAC | | | 61G15-23.002(2) & FS 471.025. | | | | | | 10. SHT MP-1 NOTES FOR GREASE INTERCEPTOR: NOTE 3 PER | | | SECTION 90-124(7)(F) GREASE INTERCEPTORS SHALL BE STEEL | | | REINFORCED CONCRETE AND FIBERGLASS INTERCEPTORS ARE NOT | | | APPROVED. PLEASE INDICATE ON PLANS. | | | | | | 11. SHT MP-1 NOTES FOR GREASE INTERCEPTOR: NOTE 6. | | | GREASE INTERCEPTORS ARE TO BE SIZED BY ENVIRONMENTAL | | | COMPLIANCE SECTION OF THE UTILITY DEPT. PLEASE CONTACT | | | RODNEY COMPO, (561) 822-2272, E-MAIL [email protected], OR | | | CALVIN WILLIAMS, (561) 822-2284, E-MAIL | | | [email protected]. THEIR FAX NUMBER IS (561) 822-2287. | | | A WRITTEN VERIFICATION FROM ENVIRONMENTAL COMPLIANCE | | | SHALL BE SUBMITTED WITH PLANS FOR GREASE INTERCEPTOR | | | APPROVAL. | | | | | | 12. NOTE: FLOOR DRAINS ARE NOT APPROVED INDIRECT WASTE | | | INTERCEPTORS. PER SECTIONS 802.3 & 802.3.2. | | | | | | 13. SHT MP-2 SANTITARY/GREASE ISOMETRIC RISER DIAGRAM. | | | THE RISER DIAGRAM DOES NOT REFLECT THE FLOOR PLAN, NOR | | | DOES IT MEET CODE REQUIREMENTS.--2-WAY CLEANOUTS | | | ARE REQUIRED AT THE INLET AND THE OUTLET OF THE GREASE | | | INTERCEPTOR AS WELL AS NEAR THE JUNCTION OF THE | | | BUILDING DRAIN & BUILDING SEWER AS THE LINE EXITS THE | | | BUILDING.--A VENT IS REQUIRED FOR THE CAN WASH.-- | | | FLOOR DRAIN NOT APPROVED UNDER THE EXPRESS MACHINE #2, | | | FLOOR SINK REQUIRED.--FLOOR SINK REQUIRED FOR THE 3 | | | COMPARTMENT SINK IN THE FOOD PREP AREA.--2" FLOOR | | | DRAIN SHOWN BETWEEN THE EXISTING LAV AND THE 3 | | | COMPARTMENT SINK IS NOT SHOWN ON THE FLOOR PLAN.-- | | | FLOOR SINK IS REQUIRED AT THE ICE MAKER.--THE 4" | | | FLOOR DRAIN SHOWN BY THE EXISTING W/C IN THE 2ND FLOOR | | | BATHROOM DOES NOT CONNECT TOSANITARY PIPING, NOR IS | | | IT SHOWN ON THE FLOOR PLAN.--THE PIPING TO THE | | | TRENCH DRAIN AND THE DRAIN CONNECTION DO NOT REFLECT | | | THE FLOOR PLAN.PLEASE MAKE SURE THE RISER DIAGRAM | | | CORRELATES WITH THE FLOOR PLAN AND MEETS CODE | | | REQUIREMENTS. SECTIONS 1006.1.1,708.3.5,901.2.1 & | | | 802.3, & UTILITY DEPT. STANDARDS. | | | | | | 14. SHT MP-2 HOT & COLD RISER DIAGRAMS. HOT WATER & | | | BACKFLOW PROTECTION REQUIRED TO SUPPLY THE CAN WASH. | | | SECTIONS 414.1, 601.7, 608.13.1 THRU 608.13.6 & | | | 608.13.8. | | | | | | 15. THERMAL EXPANSION CONTROL IS REQUIRED PER SECTION | | | 607.3.2. INDICATE METHOD ON THE WATER HEATER DETAIL. | | | | | | 16. SHT MP-2 PLUMBING GENERAL NOTE #7, AIR CHAMBERS ARE | | | NOT APPROVED. PLEASE DELETE FROM NOTE. SECTION 604.9. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED NEAR THE | | | FIXTURES, IN AN "EFFECTIVE RANGE" NOT IN THE CEILING. | | | PDI-WH 201 AND MANUF. INSTALLATION INSTRUCTIONS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-10-21 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-10-21 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2008-10-21 17:42:42 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PROVISO GROUND COVER TO BE PLANTED UNDER THE STAIRWELL | | | SHALL BE FOXTAIL FERN. | | | | | | PROVISO NEW LANDSCAPE AREAS (REVISION NO. 5) SHALL BE | | | PLANTED PER ATTACHED LETTER DATED 10-15-2008. A REVISED | | | LANDSCAPE PLAN SHOWING THE APPROVED CHANGES OF THIS | | | SITE PLAN SHALL BE SUBMITTED, AND APPROVED BY THE CITY | | | PRIOR TO C.O. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-06-04 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-06-04 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2008-06-04 16:40:19 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | | | | AN IRRIGATION PERMIT SHALL BE OBTAINED PRIOR TO THE | | | INSTALLATION OF IRRIGATION AND LANDSCAPING,AS WELL AS | | | A RIGHT-OF-WAY PERMIT FOR IRRIGATION ON THE | | | RIGHT-OF-WAY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-05-05 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-05-05 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2008-05-05 16:17:11 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PROVISO GLARE SHALL NOT EXCEED 0.5 FOOT CANDLE AT OR | | | BEYOND THE CENTERLINE OF THE ALLEY. | | | | | | PROVISO A COPY OF THE RECORDED ACCESS EASEMENT PRIOR TO | | | OBTAINING THE CERTIFICATE OF OCCUPANCY. | | | | | | AN IRRIGATION PERMIT SHALL BE OBTAINED PRIOR TO THE | | | INSTALLATION OF IRRIGATION AND LANDSCAPING,AS WELL AS | | | A RIGHT-OF-WAY PERMIT FOR IRRIGATION ON THE | | | RIGHT-OF-WAY. | | | | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-01-31 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-01-31 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2008-01-31 15:25:53 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PROVISO GLARE SHALL NOT EXCEED 0.5 FOOT CANDLE AT OR | | | BEYOND THE CENTERLINE OF THE ALLEY. | | | | | | PROVISO WHEEL STOP SHALL BE 2 FEET FROM THE CURB TO THE | | | BACK OF THE WHEEL STOP. | | | | | | PROVISO A COPY OF THE RECORDED ACCESS EASEMENT PRIOR TO | | | OBTAINING THE CERTIFICATE OF OCCUPANCY. | | | | | | AN IRRIGATION PERMIT SHALL BE OBTAINED PRIOR TO THE | | | INSTALLATION OF IRRIGATION AND LANDSCAPING. | | | | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | | | | | | | 2008-01-31 09:19:05 | IN ZONING FOR REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-10-30 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-10-30 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2007-10-30 11:10:25 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. THE SUBMITTED APPRAISAL OF REAL PROPERTY REPORT, | | | DATED SEPTEMBER 29, 2007, STATES THAT THE DEPRECIATED | | | REPLACEMENT VALUE FOR THE SUBJECT PROPERTY IS | | | $328,600.00.ACCORDING TO THE RESPONSE LETTER DATED | | | OCTOBER 16, 2007, THE TOTAL AMOUNT OF CONTRACT IS | | | $234,000.00.THIS AMOUNT EXCEEDS 50% OF THE | | | IMPROVEMENT VALUE ($164,300).THUS, THE SITE SHALL BE | | | BROUGHT INTO COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS. | | | A. PER SECTION 94-443(C)(3)(A), TERMINAL LANDSCAPE | | | ISLANDS SHALL CONTAIN AT LEAST 1 SHADE OR FLOWERING | | | TREE.AT LEAST 1 OF THE PROPOSED CABBAGE PALMS SHALL | | | BE REPLACED BY A SHADE OR FLOWERING TREE ON EACH | | | TERMINAL LANDSCAPE ISLAND. | | | B. LANDSCAPE AREA SHALL BE PROVIDED ALONG THE EAST | | | PROPERTY LINE.IT IS STAFF?S RECOMMENDATION THAT THE | | | ADDITIONAL CABBAGE PALMS BE RELOCATED ALONG THE EAST | | | BUILDING FA?ADE OF THE ADULT ENTERTAINMENT BUILDING | | | (AREA WHERE THE EXISTING BILLBOARD STRUCTURE IS | | | LOCATED). | | | C. PER SECTION 94-444(B), WALLS OF A DUMPSTER ENCLOSURE | | | SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT | | | TWO-FOOT INTERVALS.SHRUBS AND HEDGES SHALL BE PLANTED | | | ALONG THE NORTH WALL OF THE PROPOSED DUMPSTER | | | ENCLOSURE. | | | | | | 3. THERE APPEARS TO BE A DISCREPANCY IN THE DUMPSTER | | | ENCLOSURE DIMENSIONS SHOWN ON SHEET A-1.1.ACCORDING | | | TO THE DUMPSTER ENCLOSURE DETAIL, THE PROPOSED DUMPSTER | | | ENCLOSURE WILL BE 8 FEET WIDE.HOWEVER, THE DETAIL | | | ALSO SHOWS A 10 FOOT WIDE STOP BAR AND A 12 FEET BY 12 | | | FEET CONCRETE PAD INSIDE THE DUMPSTER ENCLOSURE. | | | PLEASE REVISE. | | | | | | 4. PER SECTION 94-485(P), LOADING SPACE SHALL BE 10 | | | FEET BY 25 FEET.PLEASE REVISE.PLEASE NOTE THAT THE | | | SURVEY AND SITE PLAN SHOW A REAR SETBACK OF 8.9?. | | | | | | 5. AN ACCESS EASEMENT ALONG THE SOUTH PROPERTY LINE | | | SHALL BE RECORDED.PLEASE CONTACT MR. VINCE NOEL, CITY | | | SURVEYOR, ENGINEERING SERVICES DEPARTMENT, AT (561) | | | 494-1040 FOR FURTHER INFORMATION. | | | | | | 6. PLEASE VERIFY WITH THE CONSTRUCTION SERVICES | | | DEPARTMENT HOW THE ACCESSIBLE ROUTE FROM THE SIDEWALK | | | TO THE BUILDING WILL BE PROVIDED. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-08-13 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-08-09 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2007-08-13 14:37:37 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. PLEASE NOTE THAT 4 FEET OF THE EXISTING ALLEY IS | | | UNPAVED.PLACING A LANDSCAPE BUFFER ALONG THE SOUTH | | | PROPERTY LINE WILL DECREASE THE WIDTH OF THE ALLEY TO 8 | | | FEET.PROVIDE APPROVAL, IN WRITING, FROM THE | | | ENGINEERING SERVICES DEPARTMENT FOR THE LOCATION OF THE | | | LANDSCAPE ISLANDS ALONG THE SOUTH PROPERTY LINE. | | | | | | 3. PER SECTION 94-441(C)(2) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS), RENOVATIONS, REPAIR, | | | ALTERATION OR REDEVELOPMENT WHICH EXCEEDS 50 PERCENT OF | | | THE VALUE OF THE STRUCTURE SHALL COMPLY WITH THE | | | STANDARDS SET FORTH IN ARTICLE XIV OF THE ZLDRS.AS | | | THE PROPOSED RENOVATIONS EXCEED 50 PERCENT OF THE VALUE | | | OF THE STRUCTURE, A LANDSCAPE PLAN PREPARED, SIGNED AND | | | SEALED BY A REGISTERED LANDSCAPE ARCHITECT, AND MEETING | | | THE LANDSCAPE PROVISIONS SET OUT IN ARTICLE XIV OF THE | | | ZLDRS, SHALL BE PROVIDED. | | | A. PLEASE PROVIDE A DATA TABLE STATING THE REQUIRED AND | | | PROVIDED LANDSCAPE, TO INCLUDE THE RATIO OF SHADE TREES | | | SUBSTITUTED BY PALM TREES, AS DEFINED IN SECTION | | | 94-442(B) AND (C) OF THE ZLDRS. | | | B. PROVIDE XERISCAPE REQUIREMENT POINTS. | | | C. PROVIDE TREE PLANTING PLAN DETAILS MEETING THE | | | CITY?S ZLDRS.PLEASE SEE THE ATTACHED DIAGRAM FOR | | | REFERENCE. | | | D. PLEASE NOTE THAT PER SECTION 94-443(B), THE OWNER OF | | | THE PROPERTY SHALL INSTALL AND MAINTAIN A LANDSCAPE | | | BUFFER STRIP ALONG THE ENTIRE EDGE OF THE PROPERTY | | | ADJACENT TO A PUBLIC THOROUGHFARE AND OTHER | | | NONRESIDENTIAL ZONING DISTRICTS. THE BUFFER STRIP SHALL | | | BE AT LEAST FIVE (5) FEET WIDE.AT LEAST ONE SHADE OR | | | FLOWERING TREE SHALL BE PLANTED FOR EACH 30 LINEAR FEET | | | OR PORTION THEREOF.THE BUFFER STRIP MAY NOT BE | | | INTERRUPTED BY MORE THAN 25% OF ITS REQUIRED LENGTH TO | | | PROVIDE FOR SIGNS OR VEHICULAR INGRESS AND EGRESS. | | | E. PLEASE NOTE THAT PER SECTION 94-443(C)(2), VEHICULAR | | | USE AREAS SHALL BE SCREENED FROM THOROUGHFARES AND | | | RESIDENTIAL USES AND DISTRICTS BY A LANDSCAPE BUFFER OF | | | AT LEAST FIVE (5) FEET IN WIDTH. | | | F. PURSUANT TO SECTION 94-443(C)(5)(A), LANDSCAPE AREAS | | | SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY | | | NONMOUNTABLE, CONCRETE CURBING OF THE TYPE CATEGORIZED | | | AS ?TYPE D.?LABEL THE TYPE OF CURB WHEREVER | | | APPLICABLE. | | | G. PLEASE CONTACT THE PLANNER REVIEWER TO DISCUSS | | | LANDSCAPE OPTIONS. | | | | | | 4. PURSUANT TO SECTION 94-443(C)(3)(A) OF THE ZLDRS, | | | EACH ROW OF PARKING SPACES SHALL BE TERMINATED BY | | | LANDSCAPE ISLANDS OF NOT LESS THAN 5 FEET IN WIDTH AND | | | NOT LESS THAN THE LENGTH OF THE ADJACENT PARKING STALL. | | | THE LANDSCAPE ISLAND SHALL CONTAIN AT LEAST 1 SHADE OR | | | FLOWERING TREE. | | | A. A TERMINAL ISLAND SHALL BE PROVIDED ADJACENT TO THE | | | HANDICAP PARKING SPACE. | | | B. A TERMINAL ISLAND SHALL BE PROVIDED AT THE END OF | | | EACH PARKING ROW. | | | C. THE PARKING SPACE ALONG THE SOUTH PROPERTY LINE OF | | | THE PARKING ROW ADJACENT TO THE WEST BUILDING FA?ADE | | | SHALL BE REMOVED IN ORDER TO PROVIDE THE REQUIRED 5 | | | FOOT WIDE TERMINAL ISLAND AT THE END OF THE PARKING ROW | | | SUBJECT TO THE APPROVAL OF THE ENGINEERING SERVICES | | | DEPARTMENT. | | | | | | 5. PER SECTION 94-305(E) OF THE ZLDRS, AT ANY ROAD | | | INTERSECTIONS, VISIBILITY SHALL NOT BE OBSCURED BY THE | | | CONSTRUCTION, PLACEMENT, OR MAINTENANCE OF A STRUCTURE | | | WALL, SIGN, FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY | | | SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT | | | WITHIN THE VISIBILITY TRIANGLE.ALL TREES WITHIN THE | | | VISIBILITY TRIANGLE SHALL BE APPROVED, IN WRITING, BY | | | THE CITY?S TRAFFIC ENGINEER, ENGINEERING SERVICES | | | DEPARTMENT. | | | | | | 6. APPROVAL FROM THE PALM BEACH COUNTY TRAFFIC DIVISION | | | SHALL BE PROVIDED FOR THE REMOVAL OF THE EXISTING CURB | | | ALONG THE NORTH PROPERTY LINE. | | | | | | 7. PLEASE NOTE THAT WHILE THE EXISTING ADULT | | | ENTERTAINMENT BUILDING IS A SEPARATE BUSINESS FROM THE | | | PROPOSED BAKERY, IT SHALL ALSO BE INCLUDED IN THE TOTAL | | | PARKING COUNT FOR THAT SITE. | | | | | | 8. PROVIDE PLANS STAMPED APPROVED FROM THE ENGINEERING | | | SERVICES DEPARTMENT FOR THE SIZE AND LOCATION OF THE | | | DUMPSTER ENCLOSURE. | | | | | | 9. PROVIDE WIDTH DIMENSION OF THE INGRESS/EGRESS POINT | | | ALONG THE SOUTH PROPERTY LINE.PLEASE NOTE THAT THE | | | INGRESS/EGRESS POINT SHALL BE NO LESS THAN 20 FEET | | | WIDE. | | | | | | 10. HANDICAP SYMBOL SHALL BE 2 FEET FROM THE OPEN END | | | OF THE PARKING SPACE. | | | | | | 11. THERE SHALL BE DOUBLE STRIPING BETWEEN THE HANDICAP | | | PARKING SPACE AND THE HANDICAP ACCESS AISLE.PLEASE | | | SEE ATTACHED DIAGRAM FOR REFERENCE. | | | | | | 12. PROVIDE EXISTING VS. PROPOSED PERCENTAGE OF | | | IMPERVIOUS AND PERVIOUS AREAS. | | | | | | 13. STAIRS ALONG THE WEST BUILDING FA?ADE ARE NOT SHOWN | | | ON THE PLANS.PLEASE CLARIFY AND ADDRESS. | | | | | | 14. THERE IS A SMALL RAMP FROM THE PARKING LOT TO A | | | DOOR ON WEST BUILDING FA?ADE, SOUTH PROPERTY LINE.THE | | | PROPOSED SITE PLAN SHOWS A LANDSCAPE AREA IN FRONT OF | | | THE DOOR.PLEASE CLARIFY AND ADDRESS. | | | | | | 15. ALL SIGNS SHALL BE APPROVED UNDER A SEPARATE | | | PERMIT.PROVIDE A PERMIT FOR ALL SIGNS. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
|
Account Summary | Usage Policy | Privacy Policy