Plan Review Details - Permit 07070910
Plan Review Stops For Permit 07070910
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-01-02 Cont ID  
Sent By rmcdouga Date 2008-01-02 Time 12:50 Rev Time 0.00
Received By rmcdouga Date 2008-01-02 Time 12:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-12-10 Cont ID  
Sent By rmcdouga Date 2007-12-10 Time 09:38 Rev Time 0.00
Received By rmcdouga Date 2007-12-10 Time 07:05 Sent To  
Notes
2007-12-10 09:38:032004 FBC W/2007 REVISIONS
  
 REVISION TO CHANGE OVERHEAD GARAGE DOOR PRODUCT
 APPROVAL IS DENIED BY BUILDING.
  
 1)FBC 106.3* CITY AMENDMENTS THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 THE NEW PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED BY THE DESIGNER OF RECORD, WHICH IS THE
 ARCHITECT IN THIS CASE.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-09-04 Cont ID  
Sent By rmcdouga Date 2007-09-04 Time 08:57 Rev Time 0.00
Received By rmcdouga Date 2007-09-04 Time 07:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-14 Cont ID  
Sent By rmcdouga Date 2007-08-14 Time 09:30 Rev Time 0.00
Received By rmcdouga Date 2007-08-13 Time 18:07 Sent To  
Notes
2007-08-14 15:11:522004 FBC W/2007 REVISIONS
 LEVEL 2 / ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) PLEASE NUMBER OR OTHERWISE IDENTIFY THE PLAN SHEETS.
 FBC* 106.1.3 AMENDED BY THE CITY OF WPB.
  
 4) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE
 2004 FBC EXISTING BUILDING.
  
 5) SHOW COMPLIANCE WITH R309.1 OPENING PROTECTION.
 OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM
 USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED.
 OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL
 BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3 / 8
 INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB CORE
 STEEL DOORS NOT LESS THAN 1 3 / 8 INCHES (35 MM) THICK,
 OR 20-MINUTE FIRE-RATED DOORS. SPECIFY ON THE PLANS
 THAT THE OFFICE IS NOT TO BE USED FOR SLEEPING PURPOSES
 AND INDICATE THE DOOR TYPE.
  
 6) SPECIFY THE BOTTOM CORD LIVE LOAD FOR THE TRUSSES ON
 THE PLANS. SEE TABLE R301.5.
  
 7) REVISE THE ROOF SHEATHING FASTENING NOTES TO REQUIRE
 8D RING SHANK NAILS FOR ALL ROOF ZONES. SEE
 R803.2.3.1.
  
 8) THE TRUSS ANCHOR IDS SPECIFIED ON THE ROOF TRUSS
 PLAN DO NOT CORRESPOND WITH THE SIMPSON TRUSS ANCHOR
 SCHEDULE, WHICH ONLY LISTS TRUSS HANGERS. PLEASE
 CLARIFY.
  
 9) REVISE THE DESIGN DATA TO SPECIFY EXPOSURE CATEGORY
 'C'. R301.2.1.4 EXPOSURE CATEGORY. 3. EXPOSURE C. 3.
 EXPOSURE C. OPEN TERRAIN WITH SCATTERED OBSTRUCTIONS,
 INCLUDING SURFACE UNDULATIONS OR OTHER IRREGULARITIES,
 HAVING HEIGHTS GENERALLY LESS THAN 30 FEET (9144 MM)
 EXTENDING MORE THAN 1,500 FEET (457.2 M) FROM THE
 BUILDING SITE IN ANY QUADRANT. THIS EXPOSURE SHALL ALSO
 APPLY TO ANY BUILDING LOCATED WITHIN EXPOSURE B-TYPE
 TERRAIN WHERE THE BUILDING IS DIRECTLY ADJACENT TO OPEN
 AREAS OF EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A
 DISTANCE OF MORE THAN 600 FEET (182.9 M). SHORT-TERM
 (LESS THAN TWO YEAR) CHANGES IN THE PRE-EXISTING
 TERRAIN EXPOSURE, FOR THE PURPOSES OF DEVELOPMENT,
 SHALL NOT BE CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT
 BUILD OUT WILL OCCUR WITHIN THREE YEARS AND THE
 RESULTANT CONDITION WILL MEET THE DEFINITION OF
 EXPOSURE B, EXPOSURE B SHALL BE REGULATING FOR THE
 PURPOSE OF PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN
 COUNTRY, GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS
 CATEGORY DOES NOT INCLUDE INLAND BODIES OF WATER THAT
 PRESENT A FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND
 WATERWAYS OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR
 MORE (SEE EXPOSURE D).
  
 10) REVISE THE WINDOW BUCK DETAIL TO COMPLY WITH FBC
 1714.5.4.2, WHICH REQUIRES THE BUCK TO EXTEND BEYOND
 THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS PROVIDED.
  
 11) SPECIFY THE SIZE OF THE GARAGE DOOR ON THE PLANS.
 FBC* 106.1.2 AMENDED.
  
 12)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 13) THE MAXIMUM DOOR HEIGHT ALLOWED BY THE PREMDOR
 PRODUCT APPROVAL IS 6'-8" AND AN 8'-0" DOOR IS
 SPECIFIED ON THE PLANS. SUBMIT CORRECT PRODUCT
 APPROVAL.
  
 14) SPECIFY WHICH ONE OF THE ATTACHMENT METHODS LISTED
 IN THE HANSON ROOF TILE NOA WILL BE USED FOR
 INSTALLATION. CIRCLE THE APPROPRIATE ITEM ON THE NOA.
  
 15) SUBMIT PRODUCT APPROVALS FOR THE SIMPSON TRUSS AND
 WALL CONNECTORS AS REQUIRED BY FAC RULE 9B-72.
  
 16) SUBMIT A KEY PLAN AND INSTALLATION SCHEDULE FOR THE
 STORM PANELS. SPECIFY THE MOUNT TYPE, FASTENER TYPE,
 FASTENER SPACING, SPANS, EDGE DISTANCE, GLASS
 SEPARATION DISTANCE, ETC.
 SEE ATTACHED SAMPLE INSTALLATION SCHEDULE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-12-13 Cont ID  
Sent By btrobaug Date 2007-12-13 Time 07:18 Rev Time 0.00
Received By btrobaug Date 2007-12-13 Time 06:29 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-08-29 Cont ID  
Sent By btrobaug Date 2007-08-29 Time 09:32 Rev Time 0.00
Received By btrobaug Date 2007-08-29 Time 07:47 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-08-02 Cont ID  
Sent By btrobaug Date 2007-08-02 Time 14:14 Rev Time 0.00
Received By btrobaug Date 2007-08-02 Time 13:08 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-12-28 Cont ID  
Sent By spalmer Date 2007-12-28 Time 14:44 Rev Time 0.00
Received By spalmer Date 2007-12-28 Time 14:44 Sent To B
Notes
2007-12-28 14:45:03TO ROBERT MCDOUGALS DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-12-07 Cont ID  
Sent By adarroug Date 2007-12-07 Time 12:00 Rev Time 0.00
Received By adarroug Date 2007-12-07 Time 12:00 Sent To B
Notes
2007-12-07 12:00:37TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-12-07 Cont ID  
Sent By adarroug Date 2007-12-07 Time 11:58 Rev Time 0.00
Received By adarroug Date 2007-12-07 Time 11:58 Sent To E
Notes
2007-12-07 11:58:29TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 09:13 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 09:13 Sent To Z
Notes
2007-08-23 09:13:45TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-14 Cont ID  
Sent By rmcdouga Date 2007-08-14 Time 09:30 Rev Time 0.00
Received By rmcdouga Date 2007-07-30 Time 09:45 Sent To  
Notes
2007-07-30 09:45:46TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-08-29 Cont ID  
Sent By tgordon Date 2007-08-29 Time 09:59 Rev Time 0.25
Received By tgordon Date 2007-08-29 Time 09:59 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-07-31 Cont ID  
Sent By tgordon Date 2007-07-31 Time 13:53 Rev Time 0.45
Received By tgordon Date 2007-07-31 Time 13:53 Sent To E
Notes
2007-07-31 14:44:46*** DENIED ***
 1) ENERGY CALCULATIONS LINE 9A-1 SHOWS R-4.5, SEE
 SECOND PAGE OF ENERGY CAL'S. TABLE 6C-1 MINIMUM IS R-5,
 PLEASE CORRECT PER 2004 FBC 13-600.1.C.
  
 2) ENERGY CAL'S. LINE 9B-2 SHOWS R-13, SEE TABLE 6C-1
 MINIMUM IS R-11 FOR ALL 2X4 FRAME WALLS (EXTERIOR AND
 ADJACENT), PLEASE CORRECT PER 2004 FBC 13-602.1.C.
  
 3) PLANS PAGE FOR TYPICAL WALL SECTION SHOWS R-19 BATT
 INSULATION FOR KNEE WALLS. KNEEWALLS ARE CEILING AREA
 AND NEED R-30 INSULATION, PLEASE CORRECT PER 2004 FBC
 13-604.1.A.2.
  
 4) PLANS PAGE FOR TYPICAL WALL SECTION SHOWS R-3
 INSULATION BETWEEN FURRING STRIPS. TABLE 6C-1 MINIMUM
 IS R-5, PLEASE CORRECT PER 2004 FBC 13-600.1.C.
  
 5) PLANS PAGE MECHANICAL PLAN SHOWS R-11 INSULATION SEE
 FRONT PAGE OF ENERGY CALCULATIONS LINE 9B-2 SHOWS R-13,
 PLEASE CORRECT.
  
 6) INFORMATION MISSING IN TITLE BLOCK FOR ARCHITECT (
 ARCHITECT LICENSE NUMBER) SEE FAC 61G1-16.004 TITLE
 BLOCK.
 A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR
 INTERIOR DESIGN DRAWINGS AND SPECIFICATION
 IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A
 MINIMUM, CONTAIN THE FOLLOWING INFORMATION:
 (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT. ("JOB ADDRESS"
 SEE CITY WPB AMEND. 106.1.1).
 (4) DATE PREPARED.
 (5) A SPACE FOR THE SIGNATURE AND DATED SEAL.
 (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING
 THE DOCUMENT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-08-06 Cont ID  
Sent By jleech Date 2007-08-06 Time 09:50 Rev Time 0.00
Received By jleech Date 2007-08-06 Time 09:50 Sent To B
Notes
2007-08-06 09:51:13NO PLUMBING SHOWN ON DRAWINGS.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-08-23 Cont ID  
Sent By choops Date 2007-08-23 Time 17:17 Rev Time 0.00
Received By choops Date 2007-08-23 Time 17:17 Sent To E
Notes
2007-08-23 17:18:31TO BE APPROVED BY HOA
  
 SENT TO BT

Review Stop Z ZONING
Rev No 1 Status P Date 2007-07-30 Cont ID  
Sent By choops Date 2007-07-30 Time 17:24 Rev Time 0.00
Received By choops Date 2007-07-30 Time 17:24 Sent To E
Notes
***NONE***