| Plan Review Stops For Permit 07070800 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-25 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-25 |
Time |
06:09 |
Sent To |
|
|
| Notes |
| 2007-10-27 10:19:46 | REVIEW DONE BY M JOCOBS J LEECH ENTERED ON ERROR | | 2007-10-25 08:58:44 | BUILDING PLAN REVIEW | | | PERMIT: 07070800 | | | ADD: 1700 PBL BLVD #130 | | | CONT: HOLT LEE CONST. INC. | | | TEL: (954)725-4881 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 3RD | | | ACTION: DENIED | | | | | | 1)OK | | | 2)OK | | | 3)OK | | | 4)OK | | | 5)OK | | | 6)OK | | | 7)OK | | | 8)OK | | | 9)OK | | | 10)OK | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-04 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-04 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-04 |
Time |
06:09 |
Sent To |
|
|
| Notes |
| 2007-10-04 15:06:55 | BUILDING PLAN REVIEW | | | PERMIT: 07070800 | | | ADD: 1700 PBL BLVD #130 | | | CONT: HOLT LEE CONST. INC. | | | TEL: (954)725-4881 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4)SHEETS D1 AND D2 IS MISSING THE PRINTED NAME AND | | | NUMBER OF THE PERSON SEALING THE PLANS. | | | FAC. 61G1-16.004 | | | | | | 5)OK | | | | | | 6)OK | | | | | | 7)OK | | | | | | 8)OK | | | | | | 9)OK | | | | | | 10)IF THERE IS A RECEPTIONIST COUNTER, IT SHALL MEET | | | THE REQUIREMENTS OF FBC. 11-7 WHEREA PORTION OF THE | | | MAIN COUNTER IS A MINIMUM OF 36 INCHES IN LENGTH AND A | | | MAXIMUM HEIGHT OF 36 INCHES. | | | **NOTED** | | | IF THERE IS A WINDOW NEXT TO THE WAITING ROOM WHERE | | | CUSTOMERS HAVE TO USE, IT SHALL MEET THE REQUIREMENTS | | | OF SECTION 11-7. WALL TYPE ?C? ON SHEET D1 SHALL BE A | | | MAXIMUM HEIGHT OF 36 INCHES. THE DESIGN OF ALL AREAS | | | USED FOR BUSINESS TRANSACTIONS WITH THE PUBLIC SHALL | | | COMPLY WITH SECTION 11-7. PROVIDE AN ELEVATION DETAIL | | | DRAWING OF THE AREA WHERE THE WINDOW OR OPENING WILL BE | | | INSTALLED. ANY GLASS USED IN THIS AREA SHALL BE | | | SAFETY/TEMPERED GLASS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-11 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-11 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2007-08-11 16:43:00 | BUILDING PLAN REVIEW | | | PERMIT: 07070800 | | | ADD: 1700 PBL BLVD | | | CONT: HOLT LEE CONST. INC. | | | TEL: (954)725-4881 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) 2004 FBC EXISTING | | | 301.5A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 3)ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | | 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE/WITH THE 2006 REVISIONS. | | | | | | 4)SHEETS D1 AND D2 IS MISSING THE PRINTED NAME AND | | | NUMBER OF THE PERSON SEALING THE PLANS. | | | FAC. 61G1-16.004 | | | | | | 5)THE DBPR WEB-SITESHOWS MPA DESIGN INC INTERIOR | | | DESIGN BUSINESS HAS A "DELIQUENT" STATUS. EITHER REMOVE | | | THIS INFORMATION FROM THE DRAWINGS OR THE STATUS SHALL | | | BE BROUGHT UP TO DATE WITH AN ACTIVE STATUS. SEE | | | INFORMATION SHEET FROM DBPR IN PACKAGE. | | | | | | 6)PROVIDE AN INTERIOR FINISH SCHEDULE FOR EACH ROOM | | | INDICATING THE FLAME/SMOKE DEVELOPEMENT COMPLYING WITH | | | FBC. 803 / 804 AND 805. | | | | | | 7)ON SHEET A1 SHOW A CROSS CUT SECTION OF THE NEW | | | SLAB IN RELATION TO THE DOOR THRESHOLD. FBC 11-4.13.8. | | | ALSO SEE 11-4.5.2. INDICATE THE SLOPE. | | | | | | 8)PROVIDE PRODUCT APPROVAL FOR THE NEW DOOR F-3. | | | FBC.106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 9)FBC. 11-4.24. THE SINK IN THE CONFERENCE ROOM SHALL | | | A CLEAR FLOOR SPACE OF AT LEAST 30 INCHES BY 48 INCHES | | | IN FRONT OF IT TO ALLOW FORWARD APPROACH. THE SPACE | | | SHALL EXTEND A MAXIMUM OF 19 INCHES. UNDERNEATH THE | | | SINK. NOTHING SHALL BLOCK THE FORWARD APPROACH. | | | | | | 10)IF THERE IS A RECEPTIONIST COUNTER, IT SHALL MEET | | | THE REQUIREMENTS OF FBC. 11-7WHEREA PORTION OF THE | | | MAIN COUNTER IS A MINIMUM OF 36 INCHES IN LENGTH AND A | | | MAXIMUM HEIGHT OF 36 INCHES. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-10-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-03 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-03 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-17 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-17 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2007-08-17 13:25:45 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONE COMPLIANT WITH THE FOLLOWING: | | | | | | 1} PAGE #2 OF THE THE INPUT DATA REPORT INDICATES 1 | | | LUMINAIRE @ 3800 WATTS. PLEASE INDICATE COMPLIANCE WITH | | | ALL FIXTURES TO BE USED. ALSO SUBMIT A LEGEND OF | | | FIXTURE TYPES AND WATTAGES ON THE PLAN TO CORRELATE | | | WITH THE ONES IN THE CALCULATIONS. | | | | | | 2} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBC FOR | | | SPACE CONTROLS FOR LIGHTING." STANDARD SWITCHES ARE | | | SHOWN ON THE PLAN.SHEET #2 OF THE ENERGY GAUGE ONLY | | | LISTS 1 FLUORESCENT, AND NOTE THAT ALTHOUGH A MANUAL | | | CONTROL IS LISTED, IT MUST AUTOMATICALLY TURN LIGHTS | | | OFF WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE | | | SPACE PER 13-415.1ABC.1.2(A). DESIGNATE WHICH | | | MANUFACTURER AND MODELS ARE BEING SPECIFIED FOR THIS | | | PROJECT BY THE ENGINEER. | | | | | | 3}PROVIDE EMERGENCY ILLUMINATION PER | | | NFPA-101 7.8 (2003), AND CIRCUITED PER | | | 700.12 NEC. INDICATE SAME ON PLANS. THE BATTERY PACKS | | | ARE NOT CIRCUITED WITH THE LOCAL, OR ANY,CIRCUIT. | | | | | | FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE | | | FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE INDICATE | | | THE CODE CYCLES UNDER WHICH THIS PLAN WAS DESIGNED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONE COMPLIANT WITH THE FOLLOWING: | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-10 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-10 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2007-10-10 16:15:52 | *****APPROVED***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS A1, E-1, E-2, AND FP-1 | | | WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-20 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-20 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2007-08-20 12:16:21 | *****DENIED***** | | | | | | | | | 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.THE SCOPE OF WORK SHALL NOT INTERFERE OR HINDER | | | ACCESS TO/EGRESS FROM THE OTHER TENANT SPACES ON THE | | | FLOOR, THE BUILDING, OR THE VICINITY THEREOF. | | | | | | 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 5.SPECIFY THE INTERIOR FINISH MATERIALS FOR THE NEW | | | WALLS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 6.ON SHEET E-2, AMEND FIRE ALARM SYSTEM NOTE #13 TO | | | REFLECT THAT DUCT SMOKE DETECTORS SHALL INITIATE A | | | GENERAL FIRE ALARM (AS PER LOCAL CODES). | | | | | | 7.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR FIRE | | | ALARM AND/OR FIRE SPRINKLER REMODEL. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-15 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-15 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2007-10-22 09:45:59 | TO "BOB"#12 | | 2007-10-15 11:57:46 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2007-09-24 15:49:13 | TO "BOB"#11 | | 2007-09-17 16:02:49 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-20 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-26 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2007-08-01 11:09:39 | TO "BOB"#6 | | 2007-07-26 13:59:36 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-25 |
Time |
16:00 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-10-25 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-28 |
Time |
11:44 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-09-28 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2007-09-28 11:51:50 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS REQUESTED IN LAST REVIEW 8-2-07 NOTE #2. PLEASE | | | SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 FBC | | | 13-407.1.ABC.1. WHAT WAS SUBMITTED WERE ENERGY | | | CALCULATIONS NOT COOLING LOAD CALCULATIONS. | | | | | | 2) PAGE AC-2 ON ONE SET OF PLANS WERE NOT SEALED BY THE | | | ENGINEER, SEE F.A.C. 61G15-23.002, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-02 |
Time |
13:30 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-08-02 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2007-08-02 14:05:26 | *** DENIED *** | | | 1) INFORMATION MISSING FROM TITLE BLOCK. (MAG | | | ENGINEERING INC. CA# 70615 IS NOT LISTED WITH DBPR, | | | PLEASE CORRECT) | | | SEE FAC 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | | | | 2) PLEASE SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 | | | FBC 13-407.1.ABC.1. | | | | | | 3) SHOW ON MECHANICAL PLAN HOW RETURN AIR IS GETTING BY | | | THE CEILING TO THE OPEN PLENUM ABOVE TO GET BACK TO HP | | | UNITS, SEE 2004 FBC/M 601.4. | | | | | | 4) THE EXHAUST DUCTS FOR EF-1 AND 2 CAN NOT BE IN THE | | | OPEN PLENUM, PER 2004 FBC/M 601.3 CONTAMINATION | | | PREVENTION. | | | EXHAUST DUCTS UNDER POSITIVE PRESSURE, CHIMNEYS, AND | | | VENTS SHALL NOT EXTEND INTO OR PASS THROUGH DUCTS OR | | | PLENUMS. PLEASE CORRECT. | | | | | | 5) PLEASE SHOW ON THE MECHANICAL PLANS IF THE EXISTING | | | EXHAUST DUCTS ARE POSITIVE OR NEGATIVE PRESSURE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-27 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-27 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-10-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-09 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-09 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2007-10-09 09:13:44 | DENIED; | | | PAGE D2 NOTE "H", THE DRAINAGE PIPING SHALL COMPLY WITH | | | FBC-PLUMBING SECTION 704.5, DEAD ENDS. PLEASE READ | | | SECTION AND CHANGE NOTE "H" TO COMPLY. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-06 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-06 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2007-08-06 16:56:59 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|