Plan Review Details - Permit 07070758
Plan Review Stops For Permit 07070758
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-05-10 Cont ID  
Sent By mjacobs Date 2008-05-10 Time 07:19 Rev Time 0.00
Received By mjacobs Date 2008-05-10 Time 06:20 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-04-08 Cont ID  
Sent By mjacobs Date 2008-04-08 Time 11:18 Rev Time 0.00
Received By mjacobs Date 2008-04-08 Time 10:18 Sent To PC
Notes
2008-04-08 11:18:24BUILDING PLAN REVIEW
 PERMIT: 07070758
 ADD: 512 SPENCER DR.
 CONT: STEVENSON BUILDERS INC.
 TEL: (561)441-2412
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: REVISION
 ACTION: DENIED
  
 1) WPB AMENDMENTS 106.1.2* SUBMIT A FLOOR PLAN ALONG
 WITH THE ELEVATION DRAWINGS SHOWING THE SIZE OF EACH
 OPENING FOR THE NEW WINDOWS. THE DRAWINGS SHALL CONTAIN
 THE TITLE BLOCK OF THE DESIGNER OF RECORD GEORGE F.
 WHITE. IF THE EXISTING STRUCTURE WILL BE CUT OPEN TO
 INSTALL THE ADDITIONAL WINDOWS, A HEADER AND SILL
 DETAIL IS REQUIRED SHOWING ALL MATERIALS AND THE SIZE
 OF EACH OPENING. THE ADDITIONAL COST FOR THE NEW WORK
 SHALL BE STATED ON THE REVISION APPLICATION.
  
 2)DUE TO THE FACT THE ORIGINAL SHEETS ARE BEING
 ALTERED, A NEW SHEET SHALL BE SUBMITTED FROM THE
 ARCHITECT OF RECORD. THAT SHEET SHALL SHOW ALL THE
 CHANGES WITH DETAIL ELEVATION DRAWINGS. THE ARCHITECT
 TITLE BLOCK SHALL BE INCLUDED ON ALL NEW SHEETS.
  
 3)FBC 1025.4.1
 EVERY ROOM OR SPACE GREATER THAN 250 SQUARE FEET IN
 EDUCATIONAL OCCUPANCIES USED FOR CLASSROOM OR OTHER
 EDUCATIONAL PURPOSES OR NORMALLY SUBJECT TO STUDENT
 OCCUPANCY AND EVERY ROOM OR SPACE NORMALLY SUBJECT TO
 CLIENT OCCUPANCY, OTHER THAN BATHROOMS, IN GROUP D
 OCCUPANCIES SHALL HAVE NOT LESS THAN ONE OUTSIDE WINDOW
 FOR EMERGENCY RESCUE THAT COMPLIES WITH THE FOLLOWING:
  
  
 1.SUCH WINDOWS SHALL BE OPENABLE FROM THE INSIDE
 WITHOUT THE USE OF TOOLS AND SHALL PROVIDE A CLEAR
 OPENING OF NOT LESS THAN 20 INCHES IN WIDTH, 24 INCHES
 IN HEIGHT, AND 5.7 SQUARE FEET IN AREA.
  
 2.THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN
 44 INCHES ABOVE THE FLOOR, AND ANY LATCHING DEVICE
 SHALL BE CAPABLE OF BEING OPERATED FROM NOT MORE THAN
 54 INCHES ABOVE THE FINISHED FLOOR.
  
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-08-13 Cont ID  
Sent By mjacobs Date 2007-08-13 Time 08:19 Rev Time 0.00
Received By mjacobs Date 2007-08-11 Time 16:48 Sent To  
Notes
2007-08-13 08:11:45PROVISO:
 FBC:11-4.24THE LAB STATION SINK SHALL HAVE A CLEAR
 FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES COMPLYING
 WITH SEC. 11-4.2.4 FOR THE FORWARD APPROACH. THE SPACE
 SHALL EXTEND A MAXIMUM OF 19 INCHES UNDERNEATH THE
 SINK.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-08-10 Cont ID  
Sent By btrobaug Date 2007-08-10 Time 12:48 Rev Time 0.00
Received By btrobaug Date 2007-08-09 Time 17:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2007-08-15 Cont ID  
Sent By mawillia Date 2007-08-15 Time 16:37 Rev Time 0.00
Received By mawillia Date 2007-08-15 Time 16:27 Sent To  
Notes
2007-08-15 16:37:18******NOT REQUIRED*****
  
 NO FIRE REVIEW NEEDED BASED UPON THE PROJECTED SCOPE OF
 WORK AND/OR THE SUBMITTED INFORMATION.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-05-05 Cont ID  
Sent By adarroug Date 2008-05-05 Time 09:21 Rev Time 0.00
Received By adarroug Date 2008-05-05 Time 09:21 Sent To B
Notes
2008-05-05 09:22:11TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-04-02 Cont ID  
Sent By adarroug Date 2008-04-02 Time 11:10 Rev Time 0.00
Received By adarroug Date 2008-04-02 Time 11:10 Sent To B
Notes
2008-04-02 11:10:37TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-15 Cont ID  
Sent By mawillia Date 2007-08-15 Time 16:27 Rev Time 0.00
Received By mawillia Date 2007-07-27 Time 11:14 Sent To  
Notes
2007-08-07 17:56:39SENT TO BOB # 07 MMILLER
2007-07-27 11:14:39WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-08-21 Cont ID  
Sent By tgordon Date 2007-08-10 Time 15:18 Rev Time 0.20
Received By tgordon Date 2007-08-10 Time 15:18 Sent To  
Notes
2007-08-10 15:37:23MECHANICAL PLAN TO BE SUBMITTED WITH MECH. PERMIT
 APPLICATION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-08-15 Cont ID  
Sent By jleech Date 2007-08-15 Time 11:19 Rev Time 0.00
Received By jleech Date 2007-08-15 Time 11:07 Sent To  
Notes
2007-08-15 11:21:52PROVISO
 GAS APPLICATION REQUIRED WITH PLANS BY LICENSED
 PLUMBING CONTRACTOR.

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By choops Date 2007-08-13 Time 17:04 Rev Time 0.00
Received By choops Date 2007-08-13 Time 17:04 Sent To  
Notes
2007-08-13 17:04:49*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.


Account Summary | Usage Policy | Privacy Policy