| 2007-08-30 18:16:01 | BUILDING PLAN REVIEW |
| | PERMIT: 07070732 |
| | ADD: 206 CLEMATIS STREET |
| | CONT: BRIAN J STRNAD CONST. INC. |
| | TEL: (407)760-3651 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST. |
| | ACTION: DENIED |
| | |
| | 1)ROOFING PERMIT; ONLY CHECKED ITEMS APPLY |
| | |
| | _XX___1.)A NOTICE OF COMMENCEMENT MUST BE FILED |
| | WITH THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, |
| | FS713.13. |
| | |
| | _XX___2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING |
| | INFORMATION ON THE APPLICATION, SEE ATTACHED |
| | POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / |
| | AREA OF EACH ROOF TYPE |
| | **RESPONSE NOTE BUT**: THE MEAN ROOF HEIGHT ON THE |
| | APPLICATION SHOWS 15 FEET. THERE IS A PROJECT IN |
| | PROGRESS AT THIS ADDRESS WHICH INDICATE THE MEAN ROOF |
| | HEIGHT AT 76 FEET. STATE CLEARLY WHERE THE 15 FEET |
| | SECTION OF THE ROOF IS LOCATED. |
| | |
| | _XX___3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED IN ADDITION TO THE EVALUATION REPORT |
| | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG |
| | **NO RESPONSE** |
| | |
| | ____4.)FOR THE FLAT DECK, SELECT THE APPROVED |
| | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER |
| | IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. |
| | |
| | _XX___5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED |
| | FASTENING FOR CORNER AND PERIMETER ZONES. |
| | ** NO RESPONSE** IF THE BUILDING IS OVER 60 FEET, THE |
| | WIND PRESSURES SHALL BE DESIGNED BY A PROFESSIONAL |
| | ENGINEER, REGISTERED ARCHITECT OR ROOFING CONSULTANT. |
| | FBC 1609.1.1 |
| | |
| | ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH |
| | METHOD OF ATTACHMENT YOU ARE USING. |
| | |
| | _XX___ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS |
| | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF |
| | CONSULTANT REQUIRED FOR ENHANCED FASTENING. |
| | ** NO RESPONSE** PROVIDE THE CALCULATIONS FOR THE |
| | ENHANCED UPLIFT PRESSURE AS STATED IN THE PRODUCT |
| | APPROVAL. |
| | |
| | 2)FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | ADDITIONAL FEES ARE DUE $77.48 |
| | |
| | ***NEW*** |
| | A)THE DESIGN CRITERIA INFORMATION SUBMITTED BY JAMES |
| | CANTWELL STATES THE BASIC WIND SPEED AS 120 MPH AND THE |
| | ESPOSURE CATEGORY=B. THE BASIC WIND SPEED FOR THE CITY |
| | OF WEST PALM BEACH IS 140 MPH. |
| | |
| | B)THERE IS ANOTHER PROJECT INPROGRESS AT AT THIS |
| | ADDRESS WITH DIFFERENT DESIGN CRITERIA INFORMATION. THE |
| | PERMIT NUMBER FOR THE PROJECT IS #07050024 THE DESIGNER |
| | OF RECORD IS DAVID LAWRANCE. I SUGGEST BOTH DESIGNERS |
| | MEET AND RESOLVE THE CONFLICT OF INFORMATION. |
| | |
| | C)106.3.3* PRODUCT APPROVALS- 2004 |
| | THOSE PRODUCTS THAT ARE RGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OFF |
| | RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |