Plan Review Details - Permit 07070699
| Plan Review Stops For Permit 07070699 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-10-17 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-10-17 |
Time |
12:32 |
Sent To |
PC |
|
| Notes |
| 2007-10-17 13:27:07 | RESIDENTIAL REROOF BUILDING REVIEW SECOND CHECKLIST. | | | REVIEW DONE UNDER EXISTING BUILDING CODE 2004,FLORIDA | | | RESIDENTIAL BUILDING CODE 2004 AND FBC 2004. | | | | | | | | | 1- NEED TO SPECIFY WHICH APPROVED FLAT ROOF ASSEMBLY IS | | | GOING TO BE INSTALLED AS REQUIRED FOR CITY POLICY FOR | | | RE-ROOFING PERMITS. SEE ATTACHED COPY (REPEAT | | | COMMENT). | | | | | | 2- SPECIFYBASE SHEET SPECIFIC FASTENING OPTION TO BE | | | USED ON SELECTED FLAT ROOF ASSEMBLY (REPEAT COMMENT). | | | | | | 3- IF SELECTED ASSEMBLYIS LIMITED BY GENERAL | | | LIMITATION #7, THEN PROVIDE RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | 03-0501.02 SUBMITTEDAND TABLE 1609.6.2.1(2) OF FBC | | | 2004. | | | ***NOTE: IF SELECTED ASSEMBLY IS LIMITED BY GENERAL | | | LIMITATION #9, THEN IT CAN'T BE USED IN THIS AREA | | | BECAUSE GENERAL LIMITATION #9 ON LAST PAGE OF NOA | | | SUBMITTED DOESN'T ALLOW NAIL ENHANCING (REPEAT | | | COMMENT). | | | | | | 4- PROVIDE 2 COPIES OF ROOFING PRODUCT APPROVAL. ONLY | | | ONE COPY WAS SUBMITTED THIS TIME. | | | | | | 5- RE-SUBMITTAL FEES ARE DUE EACH TIME AFTER THE FIRST | | | RESUBMITTAL.SEE FEES ON TOP OF SUBMITTAL FORM. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-07-23 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-07-23 |
Time |
16:34 |
Sent To |
PC |
|
| Notes |
| 2007-07-23 16:41:21 | BUILDING REVIEW CHECKLIST: | | | 1- NEED TO SPECIFY WHICH APPROVED FLAT ROOF ASSEMBLY IS | | | GOING TO BE INSTALLED AS REQUIRED FOR CITY POLICY FOR | | | RE-ROOFING PERMITS. SEE ATTACHED COPY. | | | | | | 2- SPECIFYBASE SHEET SPECIFIC FASTENING OPTION TO BE | | | USED ON SELECTED FLAT ROOF ASSEMBLY. | | | | | | 3- IF SELECTED ASSEMBLYIS LIMITED BY GENERAL | | | LIMITATION #7, THEN PROVIDE RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | 03-0501.02 SUBMITTEDAND TABLE 1609.6.2.1(2) OF FBC | | | 2004. | | | ***NOTE: IF SELECTED ASSEMBLY IS LIMITED BY GENERAL | | | LIMITATION #9, THEN IT CAN'T BE USED IN THIS AREA | | | BECAUSE GENERAL LIMITATION #9 ON LAST PAGE OF NOA | | | SUBMITTED DOESN'T ALLOW NAIL ENHANCING. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2007-07-20 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2007-07-20 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2007-07-20 12:24:27 | HISTORICAL APPROVAL PER JILLIAN PAPA |
|
|
|